Loading...
HomeMy WebLinkAboutApplication- Permit1 • Garfield County Building & Sanitation Department 108 8"' Street, Suite #20I Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO.tal Job Address / eyo6 M / `J &c.-05 Nature of Work Building Permit 49// 9- �. t7,3-06- olc2 Use of Building (5/1•in" t2-1( 7. Q, t / rev. �e Owner &&{,t,ba4d Y 0tiin-en— Contractor Amount of Permit $ 17 3S, 99 Date Clerk 166/ E-- Permit No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 Ba Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-8212/ Fax: 970-384-3470 / Inspection Line: 970-384-5003 91,97 Parcel/Schedule No: ,2j' / -‘/3-60-012- Job 3-✓1-'-oI 2 1 AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHERORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR SE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWER. MENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfon.600 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) _ Aj409 5I,1\°y Job Address:) 900 eovAq/ P2?4b , 3 2. M; &&el/ �e,� G 1.� �!l 1 Lot No: Block No: Subd. / Exemption: 2 Owner: GS�UG%'67iif/) Th($ f' eMS Address WO. b Charb-„". I0„11- Ph: e58- ,-`P%/7 n A�(AC Y3- 3 as / C /'`�• Address: Sac, sle.9 o CA "tal31 Isi �q— b 9`_ 4 c ngi a �`f�1'ia Address: r01Z C77K1D /5/Ph: 4 cam. (n n `l y _2'� Lic. No. 5 Spp.. Ft. of Bading: ��f 5F -Tit �I � S Ft. of Lot. � 3 Jr K —� Height: /�/� fJ �� No. aff FI (r ✓ . 6 Use of Building: ^gew 7 Describe Work: ectea-ig m ,Yeinu iw 8 C� sA°r/� �ork: New ❑ Alteration ❑ Remove ri9�%%�/v Addition ❑ Move _____ 9 10 Garage:,1 / ❑ Single 4.7d • o Double Carport: o Single o Double o Driveway Permit A / Q >c, On -Site Sewage Disposal Site Plan /V/7 1• (Septic) 11 Valuation of Work: S %O5, Adjusted Valuations: S /9 j j // LU �/L(D (D`� 12 i/ Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAND AMINED CORRECT. TAILAPPLICATION AND PROVISIONS OF LAWS GOW THE SAME TO BE TRUE WORKWILLBALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHE' SPE F 'D HEREIN OR NOT. THE GRANTING OF A PERMIT DOES ST ' '/UME TO GIVE AUTHORITY TO VIOLA i,,CANCEL T s.),/ .'SOF ANY OTHER STATE OR LOCA QrIN •' • ION OR THE PERFORMANCE o;iof+/ �• U / s7 7 / Plan Check Fee: 1 /064/q Permit Fee: /O I 75- Total Fee: Dated Permit Issued: J �I 3�� � OCC G>•pup Const. Type: .••••• yTC/ _ ,� Zoning: Setbacks: Manu. Home: ISDS No. & .� Fee: �.y� A"'. A / FOWNER CA( i ,, /�a • e +t AL/DATE APV./.' :irlf. i 1 AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHERORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR SE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWER. MENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfon.600 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) _ Aj409 5I,1\°y The following items are required by Garfield County for a final inspection: L A final Electrical Inspection from the Colorado State Electrical Inspector: 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road: 3. A finished roof. a lockable house. complete exterior siding. exterior doors and windows installed, a complete kitchen with cabinets. a sink with hot & cold running water, non-ahsorhent kitchen floor coverings, counter tops and finished walls. ready for stove and refrigerator, all necessary plumbing: 4. A complete bathroom, with washbowl. tub or shower, toilet stool, hot and cold running water. non-absorbent floors and walls finished and a privacy door: 5. All steps outside or inside oxer three (3) steps must have handrails. guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements: 6. Outside grading done to where water will detour awav from the building: 7. Exceptions to the outside steps, decks and grading may he made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not he issued until all the required items are completed and a final inspection made; 5. A final inspection sign otTbv the Garfield County Road & Bridge Department for driveway installation, w here applicable; as well as any final sign off by the Fire District, where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ""CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. T understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwe_ n: under building permit = 9197. 0/ Signature Date Bpcont03 2004 PLAN REVIEW CHECKLIST Applicant 44 WOO Date 5-2-051 7Building Engineered Foundation 14 r #Driveway Permit Lni` tir L/'§urveyed Site Plan ✓SSeptic Permit and Setbacks ?..41.4 Grade/Topography 30% �ttach Residential Plan Review List l/ mimum Application Questionnaire Nr/l subdivision Plat Notes islA. Fire Department Review Valuation Determination/Fees ✓ Red Line Plans/Stamps/Sticker L./ Attach Conditions Application Signed an Reviewer To Sign Application Parcel/Schedule No. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: 13Ibs.F,. 69 = 90804 ►3►ro sF ' — /1, 8')') off) • 24 20/f, 104,644 Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building Height Zoning Sign -off Road Impact Fees HOA/DRC Approval Grade/Topography 40% Planning Issues Subdivision Plat Notes EktiC Rc M,rt t,£c CR,e.&,r 05/12/2004 14:25 9254494647 c THE UPS STORE 476 PAGE 01 41R . 4f04 R1a 5e,4 Z}LIILD U44. f4A4/A/IaI6SDIR6a7'dR„ C4R-PICLD CeuR/i7 6 L r,t) woo p 5P R,,QGS, Co . 9+6o) rOR O&WR mR. 1fa,4&): rDiRecT i r#*T eny rt/a PIl uJ W. C. NUSf+lg'D, ACC »s ""�4GaNrcuhtoy6PPLyi.v& ro .Yiias F3u t c -D, to 6 Pa a n -i 1T Ai" 1406 Cat el RD. i Z., GC•lithe ooD SPR,,u6$,Go, 814°1 sUUJL°G RE t."r, a•d Garfield County Road and Bridge, District 1 7300 Hwy 82, Glenwood Springs, CO 81601 970-945-1223 pb. 945-1318 FAX Date: 05-10-04 To: Building & Planning From: Bobby Branham Re: Driveway permit exemption For: Eugene Hubbard ]906 CR 132 Glenwood Springs CO 81601 Location: Same as Above Scope of Work: Obtain building permit Road and Bridge Concerns: This property lies outside the system of maintained county roads, and is therefore exempt from County driveway permit requirements. Bobby Branham Dist.1 Road and Bridge FIT r r-CLR- nJa T .T JIGLIT RCP :TT Ln TT Rau GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. 1 1 l Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. NOTE: 106.3.1 (7.) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes__ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes >4 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual 2 L Sewage Disposal System) and the distances to the property lines, wells (on subject property.and adjacent properties), streams or water courses? Yes 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineer d esign? Yes___ 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces' and soffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes ,Zs,,c 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes k 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eavg down to existing (undisturbed) grade contours? Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation 3 including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No >c/ V 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Buildin Code Chapter q37,? Yes_ No_ f' V , A. 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? YesNo 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes__ X __ No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and to enclosures and specify safety glazing for these areas? Yes__ No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes dd/or covenants? Yes _ No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plan Yes No 21. Will this be the only residential structure on the parcel? Yes No_ __ If no - Explain: 4 22. Have two (2) complete sets of construction drawings been submitted with the application? \ J Yes_ J� 23. Do you understand that the minimum dimensions a home can be on a lot is 20ft.wide a Rd 20ft. long? Yes X No 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes x No 25. Do your plans comply with all zoning rules and regulations in the County related to your properti s zone district? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes_ No 27. Do you understand that approval for design and/or construction changes are requiredprior to the application of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time youpick up your building permit? Yes i� No 29. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Ins ections are to be called in to 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $47.00 re-inpsection fee? Yes No _ 31. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a 5 Certificate f Occupancy and occupancy of the building? Yes__ _ No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Building Code? Yes iK. No 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No_ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes x No I hereby acknowle qjai o the ge at I have read, understand and answered these f y ability. Signature of Owner Phone: 3 -77 - Date C� Date (days); (evenings) Project Nam: WDig) Gn%erpjgl/ Project 06 CO/al/ Address: / / LV B/Z Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 Steve Hackett To: Vrenl and John Dlemoz Subject: RE: Hubbard Cabin John, Thanks for the help. I have written "Extent of preexisting nonconforming building, not to be exceeded" and circled the 25.11' mark on the site plan. That will be the legal setback statement. Steve Hackett Code Enforcement Officer, Garfield County stevehackettrgarfeld-county.com Original Message From: Vrenl and John Diemoz [mailto:jvdiemoz@rof.net] Sent: Saturday, May 22, 2004 2:52 PM To: Steve Hackett Cc: Bill Hubbard Subject: Hubbard Cabin Dear Steve, Please find attached, photos from Friday afternoons site visit at the Hubbard Cabin Building site. I set a stake w/ blue ribbon at the high water mark off the NW corner of the Cabin foundation and judge the River City Surveys dimension of 25.11 feet to be accurate. If you need any additional information, please call. Sincerely yours, John Dlemoz 5/24/2004 Gecr)3tecr, HEPWORTH -PAWLAK GEOTECHNICAL April 30, 2004 Bill Hubbard 10820 Charbono Point San Diego, California 92131 H,.t' ,ItI!-1,,V '.11 L, Pi. Tiu Job No. 104 295 Subject: Percolation Testing and Observation of Backhoe Pits. Proposed Residence. 1906 Road 132 (Mitchell Creek Road), Garfield County, Colorado. Dear Mr. Hubbard: As requested, a representative of Hepworth - Pawlak Geotechnical. Inc.. performed percolation testing at the subject site. The testing was done in general accordance with our agreement for professional services to you, dated April 13, 2004. Additional pits were observed in the building area for foundation design. The proposed residence will consist of a single story wood frame structure over a crawlspace. The septic disposal system will be located uphill to the north of the residence. Foundation Design Recommendations: The subsurface conditions at the site were evaluated by observing two exploratory pits in the building area and one profile pit in the septic disposal area at the approximate locations shown on Figure 1. The pits had been excavated prior to our arrival on-site. The subsoils encountered, below about '/ to 11/2 feet of topsoil, consist of silty sand and gravel to the pit depths of 21/2 and 3 feet in the building area and 10' feet in the septic disposal area. No free water was observed in the pits and the soils were slightly moist to moist. Considering the conditions exposed in the pits and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressur of 1,500 psf should be adequate for support of the proposed residence. The subsoils could compress when wetted under load and there could be some post -construction settlement of the foundation if the bearing soils become wet. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for columns. The existing fill, topsoil and loose disturbed soils in fooling areas should be removed and the bearing level extended down to the undisturbed natural soils. We should Parker 303-841-7119 • Colorado Springs 719-633-5562 • `Ik'rr-!H „e 970-4H- Bill Hubbard April 30, 2004 Page 2 observe the completed foundation excavation to evaluate the exposed soils for bearing conditions prior to concrete placement. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for on-site granular soil as backfill. Structural fill placed beneath slab -on -grade areas can consist of the on-site granular soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. Percolation Testing: Percolation tests were conducted on April 15, 2004 to evaluate the feasibility of an infiltration septic disposal system at the site. One profile pit and three percolation holes were dug at the locations shown on Figure 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the profile pit and consist of about 11/2 feet of topsoil overlying silty sand and gravel to the pit depth of 101/2 feet. The percolation test results are presented in Table 1. The percolation test results indicate an infiltration rate between 3 and 7 minutes per inch with an average of 5 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for an infiltration type septic disposal system. We recommend a professional engineer design the septic disposal system. Limitations: The recommendations submitted in this letter are based on our observation of the soils exposed within the backhoe pits. This study is based on the assumption that soils at other part of the building and below the design bearing level have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. If variations are encountered in the foundation excavation. we should be notified to re- evaluate the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological Job No. 104 295 -�recie-F. Bill Hubbard April 30, 2004 Page 3 contaminants (MOBC) developing in the future. If the client is concerned about MOBC. then a professional in this special field of practice should be consulted. If you have any questions or need further assistance. please call our office. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL. INC. Rev. by: SLP °171 11\12 2.Alf 0 COCteb.4 JZA/ksw attaclunents Figure 1 — Location of Exploratory Pits and Percolation Test Holes Table 1 — Percolation Test Results cc: Sopris Engineering — Attn: Yancy Nichol • Job No. 104 295 .-. 1-1P - _�_ proximate Location Previous Shed and P Location of New APPROXIMATE SCALE 1"= 20' 104 295 HEPWORTH—PAWLAK LOCATION OF EXPLORATORY PITS AND GEOTECHNICAL, INC. 1 PERCOLATION TEST HOLES Figure 1 HEPWORTH-PAWLAK GEOTECHNICAL, INC TABLE 1 PERCOLATION TEST RESULTS JOE NG 101 5 HOLE NO HOLE DEPTH LENGTH OF (INCHES) INTERVAL {MIN) vaTEk DEPTH AT START OF INTERVAL (INCHES) . WATER DEPTH AT END OF INTERVAL (INCHES) DROP ir. WATER LE /EL (IN: ESI AVEFAGE PERCOLATION Pc - (MIII;''I)CH, P-1 56 10 Water added Water added Water added Water added Water added Water added Water added I 4 1/2 3:,2 4 0 - J 4 1/2 3:'2 4 1/2 3:72 41/2 1/2 _ 4 1/2 31/2 4 1/2 3 1/2 4 1/2 3:/2 P-2 56 10 Waieradded Water added Water added Water added 51/2 2 3:72 4 2 1/2 1 1/2 51/2 2 3 :/2 6 23/4 3 Y4 23/4 11/2 11/4 53/1 2 1/2 3 ''4 21/2 1/2 _ 51/2 3 21'2 P-3 70 10 Water added Water added 13/4 1 3.). 7 1 1/2 1/2 71/4 43/4 21'2 43/4 3 1 3 -6 3 2 t 2 11/4 3- 7 51/4 13/4 51/4 41/4 Note Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 14, 2004 Percolation tests were conducted on April 15 , 2004 The average percolation rates were based on the last two readings of each test March 3, 2005 TO: Andy Schwaller Garfield County Building & Planning FROM: Bill Hubbard 10820 Charbono Point San Diego, California 92131 1-858-566-4717 1-858-243-4717(Cell) REF: Building Permit No. 9127 1906 County Road 132 Glenwood Springs, Colorado 81601 �CEIVED MAR 0 3 2005 8 �INGL& PlaiNNING I am requesting a 180 day extention on my permit starting March 8, 2005. The last two inspections were for the final electric on March 2, 2005 and the drywall on September 9, 2004. Due to bad weather and the remote location of our building site, no work has been done since last October. The road has been impassable for most of the last four months. I also live in California and have had some difficulties making arrangements with sub -contractors. The person doing most of the work left town suddenly in October 2004. In six months I should be able to complete the remaining work. Thank you for any consideration you can give me in this matter. Pleas e-mailour appro f this request to whubbard@san.rr.com. Bill Hubbard 3/3/2005 7:11 AM FROM: Fax Electrical _Plumbing Inspectors 1'O: 384-3470 PAGE: 001 OF 001 •• COLORADO STATE ELECTRICAL BOARD 1580 Logan Street, Suite 550 Denver, CO 80203-1941 PERMIT # Permit Holder: Site Owner: Status: 530539 ZELENKA ELECTRIC 0390 E. VISTA DR SILT 81652 Phone: 970-876-5057 Fax: Email: RECEIVED MAR 0 3 2005 GARFIELD COUNTY BUILDING 8 PLANNING 1906 CR 132 Glenwood Springs, Garfield County, BILL HUBBARD Phone: Accepted Inspection type: Final Partial Inspection:N REMODEL RESIDENTIAL Trim Permit:N Inspector: Greg Winders 970-625-4561 Corrections: Comments: Card signed for C.O. Inspection Report Date Inspected: 03/02/2005 3/3/2005 Page 1 COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at /9C4 ��/z / 3 Z - Permit No. 9/ z 7 I have this day inspected this structure and these premises and found the following corrections needed: AkE7) c7L e c/,e ,r&. Ficttm %eY-710 You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date Y Building Inspector Phone (970) 945-8212 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit t._ 3 9 5 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Assessor's Parcel No. This does not constitute a building or use permit. L I ; � r- Owner's Name if Li Al J(H/J(1-17-11h(PI .'1-'-- I Present AddressL d, ')r)'- Y t't r��Tl''J�D Phone •l/ System Location / /'C c - ' /C. / 5174 1,' Legal Description of Assessor's Parcel No. SYSTEM DESIGN i rt �ephc Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Number of Bedrooms (or other) Required Absorption Area - See Attached Special Setback Requirements• Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and Sta ulations/requiremenntts� Q� \ �74O5 /�[' /] Other/� V / rU/ Date �! moi- O Inspector �"' RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs.alters, or installs an individual sewage disposal system in a manner which involves a knowing and materiel variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 8 months in jail or both). White - APPLICANT Yellow - DEPARTMENT I s, No. f"O 7 Job Addr ss 906)(t / 1 C �CLJ� Owner�LC�/L2 Assessor's Parcel No 20-273-(6 73 -( -ria_ Date _6-'R-6/ BUILDING PERMIT CARD (l1 _� Addressing Ol hLLth8fl P4 Contractor G1J12.¢/l---- Se cks: Front Rear Address .SS - �/?, - 9 7/7 rCa o P,rbon # l9' -95b -g one # RH INSPECTIONS Soils Test Footing y—itYNSTAJ-- FoundationJo -/C --(..;(177/-- Grout cZ/7Grout Underground Plumbing Rough Plu in i-z9-cy"TJO-- g Framing 3l -O` JJiHete.8. c0r-•�, Insulation I -/ -a�! GM r+.r Lel) e Q 04 I Roofing , , / Drywall 7-`1 C' • Gas Piping 6-!g 1134.. ?T ' f.my? /,i)1. .cX/ / - 'F D (cam S¢+-, KL .5.14$OS LH Zoning Weatherproofing Mechanical ���� Electrical Rough (State) J7�/� Electr'cal Final (tate) 3 - 2 - Final /Checklist Completed'? Certificate Occupancy # Date Septic System # 39SS� Final Date 44 ► JPJG� In- s'0 4 Other NOTES (continue on back) t Y k INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issue/a/RAW Zoned Area Permit No Cl)a—1 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULLA AND VOID Use elfrQjn ) �( ` Ar�� is a Addressjy Descnp n , Ownert�JQ Contractorb tbsneguillIftwassr Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing L; — —g___ Foundation ley-' 1/717: Underground Plumbing Insulation llbmiLe.JgL3jjv alf Rough Plumbing - / -,,i Drywall a q_q-t)c/i7 -- Chimney & Vent ")edK-i5'-tc/`j- Electric Final (by State Inspectorl3rs/ t Gas Piping—/x_ret:w Final 42 —24 -o6$ _-- Electric Rough (By State Inspector] ZJ G i Septic Final Framing $-3(—o4' )w-- (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. Phone 384-5003 THIS PERMIT IS NOT TRANSFERABLE 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD Date By IF PLACED OUTSID - COVER WITH CLEAR PLASTIC