Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County Building, Sanitation, & Planning Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO. 8870 Job Address 44,7,,,L6,241, C7'`-°�-�. / `�t��w cleC 35 k4ai).28-t Se,6eAl tjtattet Nature of Work Building Permit agog --1`i 1— eg ooa-. Use of Building 7U�GZu�i48 Owner Contractor -OWAA1 Amount of Permit $ c9-3 $ . /5 Date Clerke Telephone: (970)945-8212 GARFIELD COUNTY BUILDING PERMIT APPLICATION Garfield County (Glenwood Springs) Colorado Permit # Inspection Line: (970) 384-5003 Parcel / Schedule # 2401191 0800 Job Address: 121 Tamarisk Trail Parachute, CO 81635 . Lot #: 2 Block#: 8 Saddle backubd ooi 1@n: Filing #1 2. awner:Mithrll Enterpr; ddress:POB6144 B.M.CO, Ph: 285_9 14OWkPh: 3. Contractor: 4.1.1 Vaughan Address: 1038CR323 Rifle '625-535T": 9 Architect/Engineer: ocl.do Eng. Address:710 Cooper GWS ,CO Ph: 945-100611c#: 28085 5. Sq Ft of Building: 5 ; �0 Sq Ft of Lot: 42369 3 69 4./ — Height; 8 1 - 6 1r # of Floors: 1 6 Use of Building: Mini storage 7 DescrlbeWork: Sitework, foundation, steel buildingfor Bldg. B and A 8. Class of Work: XI New 13 Addition 0 Alteration 0 Move 13 Remove g Garage: El Single ❑ Double Carport: 0 Single 13 Double 10. 0 Driveway Permit ❑ On Site Sewage Disposal (Septic) Q Site Plan Valuation of Work $: Adjusted Valuation 4'17 3 32,7 Special Conditions: S-1 Occ. Type 11--N. Roof 'to be Class B with/ 7/1611 osb with Fire resistant slip sheets installed.o „,/ SP4*.4,X. 1 NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 160 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FORA PERIOD OF -MO DAYS ATANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED Wm -I WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF THE PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE ORCANCELTHE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW ULATING CONSTR CTION OR THE PERFORMANCE OF CONSTRU ON. 'ate' 1. Plan CheckFee E �L,a,V. 1, t __rr�� W Q,r+ 30 Permit Fee: 1408. js'- Fee: Total 32^C . .I� V Date Permit Issued: OCC Group:r• a\,., Construction Type: y /V Zoning: Sigial .fa S , _r,ContractororAuthorized Agen 'v t read I .„ notice above. ,4 ttfl i��/�!O , 1 Setbacks: Manufactured Home: Eyeing •-.•I, . tApprovallDate PlamtrgDepartrne• Appr /Date 7./ a ISDS#&Fee:: AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLI ANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY DEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28,201 CRS AS AMENDED. FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE AMn TI -FGF IT CI -1A1 1 RFr'rIAAF Mill I Ann VrlIn THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE rig TI -IO li nom nn-TIr M THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION REST SPECIFICALLY WITH II r1CIf AAIn A1n1A,C13 nn4I1ICAITC ADC ,AITCAIr1Ln Trl OC rnpieCC11ATn,C Akin 1A1 el InCADT elC 1-41C nuiklCOC IAITCDCQT Garrorn,.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE. (INITIAL) OR OWNER TO THE BUILDING CODES AND LAND THE SIGNER ERECTION, CONSTRUCTION COUNTY AND THAT THEN BUILDING OFFICIAL FROM FROM PREVENTING OR REGULATION NOT CONSTITUTE AN DISCREPANCIES. THE THE ARCHITECT, DESIGNER, __ dit,4 SS )47- -mftr The following items are required by Garfield County for a final inspection: I . A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.),IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit #SIC °\\I-\oma Signature Date Bpcont082002 1 PLAN REVIEW CHECKLIST d Applicant rr4/ t, -(-L Building ti Engineered Foundation ✓ Driveway Permit Surveyed Site Plan .A Septic Permit and Setbacks Grade/Topography 30% ,g Attach Residential. Plan,Review List ✓ 1Minimum Application Questionnaire N•?_Subdivision Plat Notes r Date 0)-03 e -ova r- 4 t 41, ii.Fire Department Review L-!4aluation Determination/Fees old Line Plans/Stamps/Sticker ki.4 Attach Conditions application Signed L Plan Reviewer To Sign Application t/ Parcel/Schedule No. M.A. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: 7700 >0. 2Z.1 173, PlanninglZonin Property L. i e Setbacks 30ft Str; am Setbacks Flooe Ploin B lding Height oning Sign -off Road Impact Fees 327 HOA/DRC Approval- 613 't11-17.. W IA°li a Grade/Topography 40%i 46 Planning Issues Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI -FAMILY RESIDENTIAL BUILDINGS including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough Information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction Under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, r c anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot. up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 40% or more on prope les must be show on site plan. Yes./ 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamq on the design. Yes No Not necessary for this project J 3. Are the plans submitted for application construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes J No Not necessary for this project 4_ Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes No Not necessary for this project..) 5. Does the site plan indicate the location and direction of the State, County or private road acces ing the property? Yes 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes . No Not necessary for this project 7. If the building is a pre-engineered structure, is there a stamped, signed engineered 2 d L foundation plan for this building? Yes No Not necessary for this project 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and a rth? Yes No Not necessary for project 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes No Not necessary for this project 10. Do the plans include design loads as required under the Uniform Building Code for roof snowloads, (a minimum of 40 pounds per square foot in Garfield County)? Yes No Not necessary for this project 11. Do the plans include design loads as required for floor loads under the Uniform Building Code Chapter 16 and Tables 16A, 16B and 16C? Yes No Not necessary for this project 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roofc nstruction? Yes./ - No Not necessary for this project 13. Is the wind speed and exposure design included in the plan? Yes No __ Not necessary for this project 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes No Not necessary for this project 15. Does the building section drawing or other detail include the method of positive conne ion of all columns and beams? Yes No Not necessary for this project 16. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes , / No Not necessary for this project 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? / Yes No Not necessary for this project J 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 31? Yes No Not necessary for this project 3 19, Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes___ No Not necessary for this project 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No Not necessary for this project N./ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No_ Not necessary for this project 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes No Not necessary for this project 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5-A) Yes No Not necessary for this project 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? / Yes No Not necessary for this project V 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No Not necessary for this project N./ 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes No Not necessary for this project • / 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes, No Not necessary for this project 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes_ No 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes \I No Not necessary for this project 4 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes .% No 31. Do you understand that approval for design and/or construction changes are required prior tp the implementation of these changes? Yes No 32. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact' fees required, at the time you pick up your building permit Yes No 33. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occu_ pancy and occupancy of the building? Yes" No 34. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party sponsible for the project complying with the Uniform Codes? Yes i No 35. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale, in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 4:00 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. inspections are to be called in to 384-5003. 3.1 36. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625601. Yes No 37. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes __No 38. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to issuance of the bui ding permit? Your attention in this is appreciated. Yes No 5 I hereby acknowledge that I have read, understand, and answered these questions to the best of my ability. Signature Date Phone \ t oZ�1S3 S(�ays); (evenings) Project Name: St.):: Project Address: ern + If you answered "No" on any of these questions you may be required to provide this information at the request of the Building Official priorto beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. if you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. *If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. Bpcomm 04/02 6 Garfield County Building and Planning Department 109 8th Street, Suite 303 Glenwood Springs, Colorado 81601 970.945.8212 Fax 970.384.3470 Plan analysis based on the 1997 Uniform Building Code ikt -444 rt720Pitto Project Number: Date: November 4, 2002 Project Name: Shore Mini --storage Address: 121 Tamarish Trail, Battlement Mesa, CO Contractor: Occupancy: Si Architect: Construction: II --N Engineer: Oddo Report By: Andy Schwaller NOTE: The code items listed in this report are not intended to be a complete' listing of all possible code requirements in the 1997 UBC. It is a guide to selected sections of the code. Report ,created using Plan Analyst software by b w & a. (719) 599-5622 Portions of the material contained in this program are reproduced from the Uniform Building Code with the permission of the International Conference of Building Officials. SEPARATION DIRECTION BOUNDARY AREA INCREASE FIRE PROTECTION NORTH Property line 21.0 Feet 21.0 Feet EAST Property line 12.5 Feet 12.5 Feet SOUTH. Property line 40.0 Feet 40.0 Feet WEST Property line 30.0 Feet 30.0 Feet Allowable area increased 12.5% for open area on 2 sides. --- Sec. 505.1 FL NAME OCC MAX FLR AREA ALLOWED RATIO STATUS 1 Mini- storage S1 ok 12750 13500 0.94 ok TOTAL FOR FLOOR 12750 13500 0.94 ok BUILDING TOTAL 12750 13500 0.94 ok ---- Sec. 504 and Table 5-B The actual height of this building is 10. feet. The maximum height of the building is..‹. feet. -- 2 5" -25" ZOt►r, C Page # 2 Code review for: Project Id.: Shore Mini -storage Address: 121 Tamarish Trail, Battlement Mesa, CO EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION Table 5--A NORTH For Bearing Non -Bearing Occupancy Wall Wall Si 0 hour 0 hour EAST For Bearing Non -Bearing Occupancy Wall Wall S1 1 hour 1 hour SOUTH For Bearing Non -Bearing Occupancy Wall Wall S1 0 hour 0 hour WEST For Bearing Non -Bearing Occupancy Wall Wall S1 0 hour 0 hour Opening Construction Protection Material None Non -Comb Opening Construction Protection Material None Non -Comb Opening Construction Protection Material None Non -Comb Opening Construction Protection Material None Non -Comb Parapet Required No Parapet Required No Parapet Required No Parapet Required No None -- No fire protection requirements for openings. 3/4 hour -- Openings are to be protected with 3/4 hr fire assemblies. 50% of the area of the wall maximum. -- Table 5-A, Footnote 5 & Sec. 503.2.2 Maximum single window size is 84 sq.ft. with no dimension greater than 12 feet. -- Sec. 713.8 Not Allowed -- Openings are not permitted in this wall. j Page # 3 Code review for: Project Id.: Shore Mini -storage Addtess: 121 Tamarish Trail, Battlement Mesa, CO OTHER ELEMENT Interior Bearing wall Interior nonbrg wall Structural Frame `Exterior Struct Frame Floor/Ceiling Assembly Roof/Ceiling Assembly Stairs BUILDING ELEMENTS Table 6-A MATERIAL RATING NOTES Noncombustible 0 hr Noncombustible 0 hr See Footnote #5 Noncombustible 0 hr Noncombustible 0 hr See footnote #1 Noncombustible 0 hr Noncombustible 0 hr Noncombustible None FOOTNOTES: 1) Elements in an exterior wall located where openings are not permitted or where protection of openings is required, shall be protected against external fire exposure as required for exterior bearing wallS or the structural framer whichever is greater. -- Table 6-A, footnote 1 5) Nonload-bearing walls within a tenant space that are not part of a 1 hr. corridor may be of: a) Noncombustible (nonrated) materials b) Fire retardant -treated wood c) One-hour construction (any material) -- Sec. 601.5.2.1 bi Page # 4 Code review for: Project Id.: Shore Mini -storage Address: 121 Tamarish Trail, Battlement Mesa, CO PENETRATIONS OF FIRERESISTIVE ASSEMBLIES WALLS ASSEMBLIES -- Sec. 709.6 Through penetrations: 1) Penetrations shall be installed as tested in the rated assembly. -- Sec. 709.6.2 2) Penetrations shall be protected by an approved penetration firestop system and shall have an F rating of not less than the required rating of the wall penetrated. -- Sec. 709.6.3 Exception: When penetrating items are steel, ferrous or copper pipes or steel conduits and the wall is concrete or masonry, the annular space shall be permitted to be grout or mortar. The minimum thickness is the thickness required to maintain the fire rating. The maximum size of the penetrating items is equivalent to a 6 -inch diameter and the opening is a maximum of 144 square inches. -- Sec. 709.6.1 Membrane penetrations: The requirements are the same as for through penetrations. -- Sec. 709.7 Exceptions: 1. Steel electrical outlet boxes that do not exceed 16 square inches provided that the area of such openings does not exceed 100 square inches for any 100 square feet of wall area. Boxes on opposite sides of the assembly shall be separated by a horizontal distance of not less than 24 inches. 2. Sprinklers with metal escutcheon plates. Noncombustible penetrating items shall not be connected to combustible materials on both sides of the membrane unless it can be confirmed that the fire -resistive integrity of wall is maintained. -- Sec. 709.7 r Page # 5 Code review for: Project Id.: Shore Mini -storage Address: 121 Taznarish Trail, Battlement Mesa, CO FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES -- Sec. 710.2 Through pentrations: Through penetrations of fire -resistive horizontal assemblies shall be enclosed in fire -resistive shaft enclosures. -- Sec. 710.2.1 Exceptions: 1. When penetrating items are steel, ferrous or copper conduits, pipes, tubes and vents through a single concrete floor, the annular space shall be permitted to be grout or mortar. The minimum thickness is the thickness required to maintain the fire rating. The maximum size of the penetrating items is equivalent to a 6 -inch diameter and the opening is a maximum of 144 square inches. 2. Electrical outlet boxes that have been tested for use in fire -assemblies. The system shall have an F rating and a T rating of not less than one hour but not less than the required rating of the floor system. -- Sec. 710.2.3 Exception: Floor penetrations contained and located within the cavity of a wall do not require a T rating. Membrane penetrations: The requirements are the same as for through penetrations. -- Sec. 710.3 Exceptions: 1. When penetrating items are steel, ferrous or copper conduits, electrical outlet boxes, pipes, tubes and vents through concrete or masonry and the annular space is protected by an approved penetration firestop assembly or protected to prevent the free passage of flame and products of combustion. Such penetrations shall not exceed an aggregate area of 100 square inches in any 100• square feet of ceiling area in assemblies without penetrations. 2. Electrical outlet boxes that have been tested for use in fire -assemblies. 3. Sprinklers with metal escutcheon plates. Fire -resistive roofs may have unprotected openings. -- Sec. 710.4 Page # 6 Code review for: Project Id.: Shore Mini -storage Address: 121 Tamarish Trail, Battlement Mesa, CO SMOKE and FIRE DAMPERS -- Sec. 713.10 and 713.11 Dampers shall be accessible for inspection and servicing: 1. Penetrations through area separation walls. Penetrations through occupancy separations. 2. Penetrations of the fire -resistive construction of horizontal exit walls or corridors serving as a means of egress. Exception: Openings for steel ducts penetrating the required fire -resistive construction of corridors are not required to have smoke dampers when such ducts are of not less than 0.019 -inch thickness (26 gage) and have no openings serving the corridor. 3. Penetrations of shaft enclosures. Exceptions: 1. Duct penetrations by steel exhaust air subducts extending vertically upward at least 22 inches above the top of the opening in a vented shaft where the airflow is upward. 2. Penetrations of a fire -resistive floor forming the base of a shaft enclosure may be protected by fire dampers listed for installation in the horizontal position. 3. Smoke dampers are not required when shaft is exhaust only, and is used for continuously operating fans. 4. Penetrations of the ceiling of fire -resistive floor -ceiling or roof -ceiling assemblies. Exception: Smoke dampers are not required. 5. Penetrations of an atrium enclosure element. Exception: Smoke dampers are not required. 6. Penetrations of exterior walls where protection of openings is required. Exception: Smoke dampers are not required. 7. Penetrations of areas of refuge. Exception: Ventilation system designed to supply outside air during an emergency. 8. Smoke dampers are required in smoke barriers and elevator lobbies. ROOFING REQUIREMENTS: 1) The roofing on this building is required to be Class B or better. -- Table 15-A 2) See section 1504 and ICBG research reports for requirements. rr E; k Page # 7 Code review for: Project Id.: Shore Mini -storage Address: 121 Tamarish Trail, Battlement Mesa, CO WALL AND CEILING FINISH: 1) Wall and ceiling finish materials are required to comply with Sec. 804.1 and Table 8-B. 2) Carpeting on the ceiling is required to have a Class I flame spread rating. -- Sec. 804.2 3) Textile wall coverings shall have Class I flame spread rating. and shall be protected by automatic sprinklers or meet the acceptance criteria of U.B.C. Standard No. 8-2 -- Sec. 805 4) Toilet room floors shall have a smooth, hard nonabsorbent surface that extends upward onto the walls at least 5 inches. -- Sec. 807.1.1 5) Walls within 2 feet of the front and sides of urinals and water closets shall have a smooth, hard nonabsorbent surface. - - Sec. 807.1.2 INSULATION NOTES: 1) All insulation material including facings are required to have a flame -spread rating of 25 or less and a maximum smoke density of 450. - - Sec. 707.3 2) Foam plastic insulations are required to be protected. -- Sec. 2602 I .1 ,, 4 Page # 8 Code review for: Project Id.: Shore Mini -storage Address: 121 Tamarish Trail, Battlement Mesa, CO GLAZING REQUIREMENTS All glazing'in hazardous locations is required to be of safety glazing material. -- Sec. 2406.3 & 2406.4 Locations: 1) Glazing in ingress and egress doors except jalousies. 2) Glazing in fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. 3) Glazing in storm doors. 4) Glazing in all unframed swinging doors. 5) Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers. Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and drain inlet. 6) Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24 -inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 7) Glazing in an individual fixed or operable panel, other thanthose locations described in items 5 and 6 above, than meets all of the following conditions: A. Exposed area of an individual pane greater than 9 square feet. B. Exposed bottom edge less than 18 inches above the floor. C. Exposed top edge greater than 36 inches above the floor. D. One or more walking surfaces within .36 inches horizontally of the plane of the glazing. 8) Glazing in railings regardless of height above a walking surface. Included are structural baluster panels and nonstructural in -fill panels. 9) Glazing in walls and fences used as the barrier for indoor and outdoor swimming pools and spas when the bottom edges is less than 60 inches above the pool side and the glazing is within 5 feet of the pool or spa water's edge. 10) Glazing in walls enclosing stairway landings or within 5 feet of then bottom and top of stairways where the bottom edge is less than 60 inches above the walking surface. Mar 07 03 02:45p Denise & f'hitriip Vaughan 970--625-4522 II -05-03' CEO 03:04 PN ATLAS ROOFING CORP FAX NO. 3032524417 SIOHIPIEETS' FINE-RESISTANT SUPSHlEETS Nur and 1.1150" :ere roof srtetu co npaucros manufactured of fire -retardant, coated glass fiber Mists uxcd to enWnee rise (werall tine pertitrmancc do root sysier11. 1'tt 5(1 incorporates a heavier glass mat thin] V11-1810 improve Lire performint& in asinl lel tyc>•.fntlt pmdurts provide: • Superior }miter Lion rt llama spread and penetration_ • A ligltt'Ycijht;ind-easy-to-installrnitfsysicll 1. • Pm of a i'Llitss A" ossrmilly tnrrr corobogil7leanelonnenenjsustibtrdechv and exit mkt' polys' ytene. " Yat t of a Class A" assembly °vet ennibtistiblc;rnd nn)ttonnhustihlc decks and espanda' pulysipme. lik•-• Nit of a "(;Leri ll'asxrr ly owe t'wnluatibte da'ck9 eltvertrt icy melts] snot panels. Alta and 11(50 arcaptctik ilyalesigr)i'1tobeused over wool] decks orcestlincombustible insulations. 4[t48, utilizing a heavytlusy nsat, is specifically designed to tee]> ucve A superior fire tulip& witI+ a minimurn nufitber of hayers. Att tc rice rt turdant tri pslreCU arc { ii+juvtcipht stir] tasy to h tndk, tin attachment is. ncc:sl ay.11 C flamed {oath g trsnatly provides usotrgh weight to anchor the sheet urrtil rile mcnsbrinst or imulstlnn can he installed. Under windy conditions. attach with, cling]) fasttnei's to pivantdL1i%tacou n1. tRlSavd1'A:A[rctem ditanter'lute+)metaWuxi. ARCHIT#c1118AL SPttCItl[Ar10ti PM) CAM 1.1 illiVSAI1 1. iy4trNnnlasrd]adrdslk¢lElOintassalnttitniustieritiNonfartAisAtIttp¢. 12 ltUltAti101iitA08141 i A RfinrrluodaAin.era[440,461.04 LS • 1. 11l:Ian itulrplaIPA inS,/ irViiHdeVnan r&Iimps raidglieta ', igthext.orosl,rcA icpktena 61+ 1 YAM ?Who chicks+iLi•grecoloprwrsiktigketkrNtu dfliclafdydrmmkrisrart fARr 2 PRODIXIS lJ 11 i[Et[i 11119llItsgIMutem<t MCV, Ata saaeoitspn EnrpidriisIt=Net w,idnts•twki tisec:e. I. ]SMIIAlid rams? hatc13'ri]ebrflr tyq omismaxinci41Nitvisa lid advinat ego 44114 stPtitdatltflRfi ltY]og Crtlgayt[tto7Lhtt 131 Timis Eti tlaN]attot. 1 t3It[(11T1G1 it. NIMMA 1 11811111354AollemAsi ttriislnewaaPurlgrattwadiVkimIII14a/4 A1iit+indlopllie,ski Aieaagkhdowsj pronitoikonk 1,7.1...A5.5- A RATING rirert ;/L'Y Ci+il•,. h`r"3iL•Vt.'r CL.11sS 8 RRT=NG mo -r. +.er/L P rirn Phidlpa Rrtrin, Atlanta, OA 18 P. 01 net -coo ASTe rrxri VS • f81tr Burst° 0On Mat tt alG4l tamix/ tit ° Doth Rrrptcafion Sal ett•tivtois arere httssoraar rArrrsos tc rNu�� $11111 Lilrsir6[Y rvis,,,fa ER"dam rWYSmer+! a,oaf..t tartly.- rG y'. r,. lova* Steel Deck and PGry$ryiane frpiribiffin • • rf [ \ty 47--I R9frr" S r A. Sep 18 03 10107a !Denise & Philip Vaughan 970-825-4522 Project Information Project # Arch. Project It Title Address 134-01 Saddleback Storage 121 Tamarisk Trail City, State, Zip Battlement Mesa, co 81636 Country USA From Contact Company Address City, State, Zip Country Phone Fax Philip Vaughan Phil Vaughan Construction Management, Inc. 1038 County Road 323 Rifle, CO 81650 USA 970-625-5350 970-625-4522 P. 1 Transmittal Transmittal Transmittal #f issue Date Subject 41©79 0911812003 Saddleback Storage- Steel Building Info. To Contact Company Address Andy Schwatter Garfield County Building Department 108 8th St. City, State, Zip Glenwood Springs, Co 81601 Country USA Phone 970-945-8212 Fax 97D-3893470 Copies and Remarks Submit Resubmit Return Copies For Distribution Sender Copies For Approval Remarks Corrected Prints Faxsimite Andy, please find attached the certification letter from Rigid Building Systems. Thanks, Phi! Vaughan Transmittal Items hem Deseri pt'on. 915103 Rigid Building Systems certification letter Thursday, September 18, 2003 Review and Comment GARFIELD COUNTY PLANNING DEPARTMENT 108 8TH STREET #201 GLENWOOD SPRINGS, CO 81601 Paye I of l Sep 18 03 10:07a Corporate Office 189433 Aldine Westfield t Houston, Texas 77073 r ie112a11-443-9065 Fax (281) 44-9064 Toll Free (888) 467-4443 September 5, 2003 RIGID S.O. NO.: CUSTOMER: ADDRESS: END-USER: JOBSITE: BUILDING END-USE: BUILDING; 1%11 Span Length 180•O" BUILDING: liBr, I Span Length Denise & Philip Vaughan RIGID BUILDING SYSTEMS 1 22591 Phil Vaughan Construction, Managment 1038 County Road 323 Rifle, CO 81650 Saddle Back Storage 121 Tamarisk Tr Battlement Mesa, CO 81635 Mini storage Mini storage (Fully Enclosed) 970--625-4522 p.2 Western Sales Office 10 Inverness Drive East, Suite 101 Englewood, CO 80111 Tel (303) 799-4579 Fax (303) 799-4803 Toll Free (800) 658-2885 Low Side Eave Height Roof Slope Bay Spacing 0.5:12 Mini Storage (Fully Enclosed) 2 @5'-O", 15 @10-0", 20'-0" 20'-0" 125'-0" Gentlemen: Low Side Eave Height Roof Slope Bay Spacing 8'-6" 0.5:12 5'-0" 12 @10'-0" This is to certify that the above structures were designed in accordance with the A.I.S_C. Specification for Structural Steel Buildings Allowable Stress Design, 961 Edition, 1989, the A,I.S.I. Specification for the Design of Cold -Formed Steel Structural Members, 1996 Edition, 1.1 Printing June 1997, A.W.S. D1.1-02 Structural Welding Code -Steer and A.W.S. 01.3-98 Structural Welding Code — Sheet Steel and generally accepted engineering practices. Loads applied to design the buildingls are no less than the requirements prescribed in the order document and the design satisfies the requirements of the UBC 1997 Buirding Code. Dead Load metal building structure only as furnished by RiGID Wind Load 90 mph, UBC '97, Exp. "13", Imp. Factor = 1.0 Live Load 40 psf (Primary Framing) without Tributary Area Reduction Live Load 40 psf (Secondary Framing) Ground Snow Load 57 psf, Exp. Factor = 0.7 Imp. Factor =1.0 Seismic Load Zone = 1, Imp. Factor = 1.0 Other Loads/Requirements Sprinkler load = 1.5 psf Accessories provided by others are to sustain the design wind load. Likewise, the customer is to ensure that the above loads comply with the requirements of local regulatory authorities. This Letter of Certification covers only the steel building and its components furnished and fabricated by Rigid Building Systems facility in Houston, Texas and specifically exclude accessories, anchor bolts, foundation, masonry, or general contract work including erection certification. Sincerely, Professional Engineer rff COUNTY AF GARFIELD - BUILDING DEPARTMENT COL ,- ECT1ON NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at /V Via''"--4f--c- "' Permit No. g70 1 have this day inspected this structure and these premises and found the following corrections needed: At4AAJ-0, yd'w `wcX 01( f You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /Q -- .2/ -p 3 20 Building Inspector Phone (970) 945-8212 INSPECTION WILL NOT BE MADE UNLESS 4 THIS CARD IS POSTED ON THE JOB . 24 HOURS NOTICE REQUIRED FOR INSPECTIONS r BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued.. ..i.Q3 Zoned Area Permit No. ... AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECO11+ + NULL A I VO Use 1 m 4.5korott re Address o Legal I escription Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.' INSPECTIONRECORD Footing, 0�2JD d1 ! 0.,.. 10 -1 03 1 1.. qo-: l o / MIR -1:: ,� Foundation Fa ii ok /0-/ /3 rapt-- Yl- . -'03 QTti. Underground Plumbing Insulation Rough Plumbing A)64,0__ Drywall Chimney & Vent A,p.,,_,,_, Electric Final (by State Inspector) _ _ Gas Piping _ Gas Final 2- '-o3 ,l1 Electric Rough (By State Inspector) _ Septic Final N ' Framing ' '1P .a-11-04,„.Notes: (To include Roof in place an i' Windows and Doors installed). t' d ., _, i2. -a -,-)3x.,. ALL LISTED ITEMS MUST BE INSPECTED WHETHER INTERIOR OR EXTERIOR, AND APPROVED BEFORE COVERING - UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD Date Iii By11 IF PLACED OUTSIDE - CODER WITH CLEAR PLASTIC