Loading...
HomeMy WebLinkAboutConstruction Observation & Testing Letter 11.30.2015HEPWORTH—PAWLAK GEOTECHNICAL November 30, 2015 Silich Construction Inc. Attn: Hayden Horsford 303 AABC, Suite J Aspen, Colorado 81611 (h horsford @silichconstruction.com) I lerwnrih Poon I,ih Gtvrechniw.il. Inc 5020 County NIA 154 Glenwood Spring,, GoloraJii 81601 Phone 970 9.15.7959 Fax 970 945 S454 cm.ul. hpgur+:hrtniech cont Job No. 115 066F Subject: Construction Observation and Testing Completion Letter, Proposed Residence, Lot 172, Ironbridge Development, 21 Bent Grass Drive, Garfield County, Colorado Gentlemen: As requested, we are providing a summary of our observation and testing services provided for the above referenced project. The reports of the services requested and performed for the project are attached. We previously conducted a subsoil study for design of foundations at the site and presented our findings in a report dated June 10, 2015, Job No. 113 471M. The foundation bearing soils within the building excavation were observed and tested for compaction on August 18, 2015 and are suitable for the recommended bearing pressure of 1,000 psf. The post -tensioned slab tendons and grade beam reinforcement were observed on September 3 and 11, the fresh concrete for the post -tensioned slab and grade beams was sampled on September 14 and tensioning of the tendons was observed on September 17, 2015 according to the project specifications. The results of the tendon tensioning were submitted to Fuhrmann & Graf for their approval. We did not observe placement of the rigid foam insulation along the building perimeter, but since the perimeter grade beam has a minimum depth of 36 inches, it provides adequate frost protection rather than by insulation. Based upon inferences drawn from our observation and testing, as documented by the attached daily field and laboratory reports, it is our professional opinion that the referenced construction has achieved the specified conditions. Please recognize that construction observation and testing are sampling functions that involve direct Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silvcrrhornc 970-468-1989 Silich Construction Inc. November 30, 2015 Page 2 observation and testing of very limited amount of the overall work to evaluate the construction compliance. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH -- PAWLAK GEOTCHNICAL, INC. /1-• ,,,;e17-. Pl.%,. 47;\-..ef ..i 2.;‘, e_l____V)Steven L. Pawlak, P.E.°'11113,;-,1111;012 1l �°I x f 2�f•: q =eo a° '',•.be COL SLP/ksw Attachments: Observation & Testing Reports: 8/18/2015 through 9/17/15 cc: Silich Construction — John Silich (john@silichconstruction.corn) Job No. 115 066F