HomeMy WebLinkAboutApplication- PermitNo. 8579
GARFIELD COUNTY
BUILDING, SANITATION,
and PLANNING DEPARTMENT
109 8th, Street, Suite 303
Glenwood Springs, CO 81601(970) 945-8212
Job Address . Q 1110. ' Cl-�
• Nature of Work 11014Wal
414 _ � 11 ► 1 �� �� 1 � ! i •
Use of Building
Owner
Contractor .cJ
Amount of Permit$ l)1 p Date `
Clerk
GARFIELD COUNTY BUILDING PERMIT APPLICATION
GARFEELD COUNTY (GLE`IWOODSPIRRNC3), COLOR -ADO
LEPHOi`.E: (970) 943-8212
Iicarrt to oarr.Qlera numbered spaces only.
PERMIT NO. S C> C
INSPECTION UNE: (970) 943.9139
FARCEUSCHEDULE NO.
Ja ADDRESS:
Small Solar Shed East Side of 1 Building - Willow Park Apartments, Battlement Mesa
AGRELNEENT
'
/SS ION ES HEREBY GRANT= 10 THE APPLICANT AS OWNER CONTRACTOR AN-DJOR THE AGEIT OF ITE CONTRACTOR OR OWNER/0 CONSTRUCT THE STRCCIt:RE A:
AILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARINCE:T .
ONSEDERATIO; i OFZi3E ISSUANCE OF TIM PERXET. THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILD) G CODES AND LAND USE REG t-AIIONS ADOPTED 5'
FIFL rl COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.21.101 CRS AS AMENDED. D. THE SIGNER FE.Xmmt. AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULL'
PLIED Wf 1 E THE LOCATON. ERECTION. CONSTRUCTION AND USE Oram ABOVE DESCRIBED STRUCTURE, "TETE PERMIT MAY THEN BE REVOKG•7] BY NC7TTCE FROM mi
N -re ANI) THATTHE:t AND TIMM IT SHALL BECOME NULL AND VOID.
ISSUANCE OF A PP:ELMIT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL Nor PREVENT IEEE HU LDING OFFICIAL FROMTFIEREAFTER. REQUIRING TH1
1ECtION OF ERRORS EN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FRO PREVENTINGB UtLDING OPERATION BE]NG CARRIED ONTH REEUNDER WHEN L VIOLATIO:
EIS CODE OR. .ANY OTHER ORDINANCE OR e2EGL-L.ATION OF-IF/3 JURISDICTION.
3.EVIEW OF'rI-IE 5L"BMIr TED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIE.
CABILrrces BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FORTHESE MEMS AND LviPLE.11:I ATlOi`I DURI`1G CONSTR1;CTI0'.
5 SPECIFICALLY WITH -ME ARCHITECT. DESIGNER BUILDER ANTI OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE A,ND LN 3 I - •RT OF THE OWNERS INTEREST
xm.003 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND I DERSTAND THE AGREEMENT ABOVE. Alit 1
RECEWEET UCT 1an
COT `0. BLOCK NO. L O rE. ■ N
N/A N/A � " t%, low Park Apartments
s,
A""1' PO Box 6000, Battlement Mesa
'4285-7330
"K'' N/A
°""bz` Battlement Mesa
`attlement Mesa Homes
PO Box 6000, Battlement Mesa
285-7330
oary.c-micamm
Greg Robson
Anima.
PO Box 6000, Battlement Mesa
285-7330
za.Tr. air nca.oa+a 138
"%mortar N/A
=car 8,
!1o.arnorms 1
C arnl'¢.ccW . h -e A
Mecharrical - •-T
'w''.4":-.
Remodel / Replacement of Existing Buildings
rs ...mor ar: =..... a...om w su r...rra:+ awvi =moan .
X
a""z' N/A .=,w= =Donau C"srarr: =sr= anacalz
)
aoexes...x uer acatsrrasaw.0 ocvauc(sEx 1 N/A =I MAN
VALVATAV ar'+.a . f "= v"LW -s . .3Y-6 . do
Same as building application you are currently working on for small solar shed located
behind A Building at the Willow Park Apartments. We don't have a permit number yet.
NOTICE
SEPARATE ELEcrxtak1. ?ERUCT LS REQUTREO AND MUST BE ISSUED BY THEE STATE OF
LOELACO. -
IS PERMIT BECOMES , iT3I_L AND VOID IF WORK OR CONSTRUCTION AUTHOR ID
NOT COidL1.1 .LACED WITEM L10 DAYS. OIL IF CONSTRUCTION OR WORK ES
SPENDEDOR.BA?IDONED FOR APERIOD OFISO DAYS ATANY T,81EAFTER WORK
CONN. ENCED.
EEREBY CERTIFY THAT I HAVE READ AND EX.1,11INED THIS APPLICATION AND
COW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
PLAN CHECK FEE:
5.4 .11
PERMIT FEE:
__.-_8 3.2,6"'
_
TOT:tL.FEE: DATE PERMIT =IMFO:
) 37 . '3(p .
OCC: GROUP CONST: TYPE:
„ 1 - V - M
IVERNEGTIES TYPE OFWORKWILL BECOMPLIEDWITHWHET 3PECIFIED
:REIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE
eTHORITY TO VIOLATE ORCANCEL THE PROVISIONS OF ANY OTTER STATE OR
CAL LAW • GULATING CONSTRUCTION OR 11HE PERFOR. OF
iNSTRT CTIO • ! /
11 a 2---
ZOtvlaNG
. -
SETBACKS:
• at • .� , rafl. orsad2rniud r3rnt • % - r;,..
IP I1 -I . .� _ 4 rff
MANU. HOME:
ISM NO. Se Fes:
Admg Dept A.. . • / .. ' ., n,.,. 35Pravi /t ,
AGRELNEENT
'
/SS ION ES HEREBY GRANT= 10 THE APPLICANT AS OWNER CONTRACTOR AN-DJOR THE AGEIT OF ITE CONTRACTOR OR OWNER/0 CONSTRUCT THE STRCCIt:RE A:
AILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARINCE:T .
ONSEDERATIO; i OFZi3E ISSUANCE OF TIM PERXET. THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILD) G CODES AND LAND USE REG t-AIIONS ADOPTED 5'
FIFL rl COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.21.101 CRS AS AMENDED. D. THE SIGNER FE.Xmmt. AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULL'
PLIED Wf 1 E THE LOCATON. ERECTION. CONSTRUCTION AND USE Oram ABOVE DESCRIBED STRUCTURE, "TETE PERMIT MAY THEN BE REVOKG•7] BY NC7TTCE FROM mi
N -re ANI) THATTHE:t AND TIMM IT SHALL BECOME NULL AND VOID.
ISSUANCE OF A PP:ELMIT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL Nor PREVENT IEEE HU LDING OFFICIAL FROMTFIEREAFTER. REQUIRING TH1
1ECtION OF ERRORS EN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FRO PREVENTINGB UtLDING OPERATION BE]NG CARRIED ONTH REEUNDER WHEN L VIOLATIO:
EIS CODE OR. .ANY OTHER ORDINANCE OR e2EGL-L.ATION OF-IF/3 JURISDICTION.
3.EVIEW OF'rI-IE 5L"BMIr TED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIE.
CABILrrces BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FORTHESE MEMS AND LviPLE.11:I ATlOi`I DURI`1G CONSTR1;CTI0'.
5 SPECIFICALLY WITH -ME ARCHITECT. DESIGNER BUILDER ANTI OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE A,ND LN 3 I - •RT OF THE OWNERS INTEREST
xm.003 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND I DERSTAND THE AGREEMENT ABOVE. Alit 1
RECEWEET UCT 1an
?v
Thl-ka-rr.
ge s c&.
s(AkoJ So[a,U
17 =7:-. z 34)(6
83. 26-
1'6-7 . 'Yo
4-
6-
4-- 1 . 50 Pa4e.y
..r
6,-.01- I .LU LUUP.I Y
•. U.Jts•ad4. U 10. 24. U. Li :4Upm Y.
PIans to be included for a Budding Permit must be on draft paper at least 18"x 24"" and drawn to
scale,
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade
line. A section showing in detail, from the bottom of the tboting to the top of the roof, including
re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house -rap, (which is required), siding or any approved building material.
A window schedule. A door schedule.
A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per
square foot. up to 7,000 feet iri elevation, an 80 M.P.H. windshear, wind exposure B, windload of
15 pounds per square foot and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will he returned.
All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC.
Applicants are required to indicate appropriately and to submit completed checklist at
time of application fora permit;
1. Is a site plan included that identifies the location of the proposed structure, additions or
other buildings, setback easements, and utility easements showing distances to the
property lines from each corner of the proposed structure prepared by a licensed surveyor
and has the surveyors signature and professional stamp on the drawing? Slopes of 30%
or more on properties must be show on site plan.
Yes Ni
2. Does the site plan when applicable include the location of the J.S.D.S. (Individual
Sewage Disposal System) and distances to the property lines, wells (on subject properly
and adjacent properties), streams or water courses? This in Formation must he certified by
a licensed surveyor with their signature and professional stamp on the design.
Yes No Not necessary for this project N
3. Are the plans submitted For application construction drawings and not drawings that are
stamped or marked identifying them as "Not for construction, for permit issuance only",
"Approval/drawings only", "For permit issuance only" or similar language?
Yes I! No Not necessary for this project
4. Is the I.S.D.S. (individual Sewage Disposal System) designed, stamped and signed by a
Colorado Registered Engineer?
Yes No Not necessary for this project N f
t r J
iarlt`r 1C.4U LUui,r
yu.7cy �r 3�rL.1J. . YuFJ111 r . .JV -r
5. Does the site plan indicate the location and direction of the State, County or private road
accessing the property?
Ycs N /J
6. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the uniform building code or per stamped engineered
design?
Yes No Not necessary for this project N /P
7. Tithe building is a pre-engineered structure, is there a stamped, signed engineered
foundation plan for this building?
Ycs No Not necessary for this project (l /f
8. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and the clearances required between wood and earth?
Yes No Not necessary for project N /1\
9. Do the plans indicate the size and location of the ventilation openings for the attic, roof
joist spaces and soffits?
Yes No Not necessary for this project N /t1
10. Do the plans include design loads as required under the Uniform Building Code for roof
snowloads, (a .minimum of 40 pounds per square foot in Garfield County)?
Yes No Not necessary for this project N
11. Do the plans include design loads as required for floor loads under the Uniform Building
Code Chapter 16 and Tables 16A, 16B and 16C?
Yes No Not necessary for this project N IJ\
12. Does the plan include a building section drawing indicating foundation, wall, floor, and
roof construction?
Yes No Not necessary for this project
13. Is the wind speed and exposure design included in the plan?
Ycs No Not necessary for this project N Ila
14. Does the building section drawing include size and spacing of floor joists, wall studs,
ceiling joists, roorrafters or joists or trusses?
Yes 4./ No Not necessary for this project
15. Does the building section drawing or other detail include the method of positive
connectign of all columns and beams?
Yes �/ No Not necessary for this project
3
Ll-iH}- IEL .l1 LUUN1 r
y.'U3dwU U. ib. U.‘ Ut :4Uprn r . UU'
16. Does the plan indicate the height of the building or proposed addition from the highest
point of the building or addition measured at mid span between the ridge and the eave
down to existing grade contours?
Yes ✓ No Not necessary for this project
17. Docs the plan include any stove or zero clearance fireplace planned for installation
including make and model and Colorado Phase II certifications or Phase II EPA
certification?
Yes _._ No Not necessary for this project _✓
18. Does the plan include a masonry fireplace including a fireplace section indicating design
to comply with the Uniform Building Code Chapter 31?
YesNo Not necessary for this project_ --.__-
19. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping rooms and/or basements comply with the requirements of the uniform
Building Code?
Yes No Not necessary for this project ✓
20. Does the plan include a window schedule or other verification that windows provide
natural light and ventilation for all habitable rooms?
Yes No Not necessary for this project a✓
21. Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally
used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub
enclosures and specify safety glazing for these areas?
Yes No Not necessary for this project 7-1
22. Do the plans include a complete design for all mechanical systems planned for
installation in this building?
Yes 41 No Not necessary for this project
23. Have all areas in the building been accurately identified for the intended usc?
(Occupancy as identitied in the Uniform Building Code Table 5-A)
Yes No Not necessary for this project ,✓
24. Does the plan indicate the quantity, tbrm, usc and storage of any hazardous materials that
may be in use in this building?
Yes No Not necessary for this project
4
L..RFIELD COUNTY
970994470
10/16/02 01240pm P. 006
25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan?
Yes 4✓ No Not necessary for this project
26. Do the plans indicate the location and dimension of restroom facilities and ifmore than
four employees and both sexes are employed, facilities for both sexes?
Ycs No Not necessary for this project
27. Do the plans indicate that restrooms and access to thc building are handicapped
accessible?
Yes No Not necessary for this project ti
28. Have two (2) complete sets of construction drawings been submitted with the
applicatr n?
Ycs �/ No
29. Have you designed or had this plan designed while considering building and other
construct}'on code requirements?
Ycs a/ No Not necessary for this project
30, Does the plan accurately indicate what you intend to construct and what will receive a
final ins ection by the Garfield County Building Department?
Yes No
31. Do you understand that approval for design and/or construction changes are required
prior to )he implementation of these changes?
Yes ,/ No
32. Do you understand that the Building Department will collect a "Plan Review" fee from
you at the time of application and that you will be required to pay the "Permit" fee as well
as any "Septic System" or "Road impact" fees required, at the time you pick up your
building.permit?
Yes No
33. Are you aware that you are required to call for all inspections required under thc Unithrm
Building Code including approval on a final inspection prior to receiving a Certificate of
Occupy cy and occupancy of the building?
Yes ✓ No
34. Arc you aware that the person signing the Permit Application whether the "Owner",
"Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the
application is the party responsible for the project complying with the Uniform Codes?
Yes V No
5
C• -. FIELD COUNT`.` 9'0.8.3470 1111' .°Ll 01:40pm P. 007
35. Are you aware that twenty-four (24) hour notice is required for all inspections?
Inspections will be made from Battlement Mesa to West Glenwood in the mornings
and from Glenwood Springs to Carbondale, in the afternoon. All inspections must
be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice
for inspections will delay your inspection one (1) day. Inspections are to he called in
to 384-5003.
36. Are you aware that prior to issuance ofa building permit you arc required to show proof
ofa driveway access permit or obtain a statement from the Garfield County Road &
Bridge Department stating one is not necessary? You can contact the Road & Bridge
Departm/7nt at 625-8601.
Yes ✓ No
37. Do you understand that you will be required to hire a State of Colorado -Licensed
Electrician and Plumber to perforin installations and hookups? The license number will
be requir5d at time of inspection,
Yes r/ No
38. Are you aware, that on the front of the building permit application you will need to fill in
the Parcel/ Schedule Number for the lot you arc applying for this permit on prior to
issuance/of the building permit? Your attention in this is appreciated.
Yes ✓ No
1 hereby acknowledge that I have read, understand, and answered these questions to
ire best of my ability.
Signature
Phone: 215 :in() ,_(days); N A/\ (evenings)
Project Narne: SCAac �ne� e-tmdeJ
Project Address: Ea4 c r elu A6Ih3
iIlo\N1�--,rk.
Note:
ID i --1 /02-
Date
02
Date
If you answered "No" on any of these questions you may be required to provide this information
at the request of the Building Official prior to beginning the plan review process. Delays in
issuing the permit are to be expected. Work may not proceed without the issuance of the permit.
*If you have answered "Not necessary for this project" on any of the questions and it is
determined by the Building Official that the information is necessary to review the application
6
Small Solar Shed - east side of Building "1"
Willow Park Apartments, Battlement Mesa, Colorado
The existing solar shed was constructed as part of the overall apartrnent project in about
1981 (probably under the jurisdiction of the 1976 Uniform Building Code), The solar
collection system was abandoned several years ago, but the solar collection panels were
not removed. The existing building is 6'-7" wide by 20'41" long (138 s.f.). The building
now contains one natural gas fired 399,000 btu/h boiler and two "side arm" hot water
storage tanks which provides the heat and domestic hot water to Building "1" of the
Willow Park Apartments. The existing electrical system consists of a secondary circuit
breaker panel (the primary panel is in the electrical room located on the east side of
Building "I") with sufficient capacity to serve the boiler, one pump, three convenience
outlets and two light fixtures. The closest Occupancy (as listed in the 1994 Uniform
Building Code) for this building is Group U, Division 1. The Occupant Load is one.
The Scope of Work for this project includes removing the existing solar collection panels
and framing system; modifying or replacing the existing wall framing (2 x 4 wood) as
required to repair damaged framing members and to provide additional headroom;
replacing the collection panel framing with new wood rafters, roof sheathing and
asphalt composition shingles; and providing new vinyl siding (over a new weather -
resistive barrier),
The Scope of Work for this project does not include any work to the existing mechanical
system or electrical system other than that which is required to accommodate the Scope
of Work and the installation of new through -the -wall louvered vents to provide
combustion air for the boiler. (These vents are sized in compliance with the 1994
Uniform Mechanical Code.)
—;1114,t - gextuat "s 60,1 Svc "1:4,Sw gc. :t,
4)Ati OP -4 Coasrmami aMar !Tr CO C! C , , .? ,
et J:2CT TO I it TZT
47. 13TIO/18 ItISPZCI"ICa74
GARFIELr. COUNTY
BUILDING G D.t ,.P tx T" " `
: u
FIELD ,COPY.,...
,per, g.
Fs c`s'cr.S' 1'S hi �'�j 1'47;..
r
cory lemew-1 IMeSR rpar-lm es
2 x 6 trim w/ metal facing
sheet metal at exist. flue
r- new door frame
12" x 18" vent, typ.
vinyl corner trim
2 x 6 trim w/ metal facing
metal cap flashing
-vinyl siding
Ltd
7t).41., t "'
vinyl corner trim
vinyl siding
r: P12„
ELEVATIONS
1/4" = 1'-0"
50 -year architectural shingles
7 -over 3O# roofing paper
T1,
L
i
r
F
Small Solar Shed - east side of Building "1"
Wlliow Park Apartments, Battlement Mesa, Colorado
mew 2 x 6 trim
metal facing
vinyl siding
new metal cap flashing
5/8" 0513 rooP sheathing
new 2 x S nailer (remove
existing 2x nailer)
new 2 x 6 rafter at 24" ox..
(w/ Simpson A55 hanger)
new 1/l6" 056
sheathing (remove
existing 3/5" plywd)
existing 2 x 4 framed
wall (S'-6" high)
DETAIL
1 1/2" = I' -O"
50 yr. architectural shingles
/over 30# roofing paper
metal drip edge
2x6trim IN/
metal Facing
vinyl siding
Sma11 Solar Shed - east side of Building "I"
Willow Park Apartments, Battlement Mesa, Colorado
30# roofing paper
moisture barrier
new 2 x 4 framed wall
w/ l/f6" 053 sheathing
(S' 1/2" long studs)
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
Date Issued11,
Zoned Area
Permit No.. 1
AGREEMENT
In consideration of the issuance of this permit, theapplicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, Iocation, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL AND VOID.
i%len/CrA,Address or Legal De, ription
W N
nerd-irw. ' `.•t'
Use
Setbacks Front Side Side Rear
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing
E
• Foundation "
Underground Plumbing 4)77
Insulation A/6, -„A_
Rough Plumbing C),
Drywall 4261,..e—
Chimney & Vent ,Ly,
Electric Final (by State Inspector) e
Gas Piping �4
_
Final V.- 7,..03 iL
Electric Rough (By State Inspector) if y
Septic Final A j fr
Framing 1-O3,'+'YL 11
(To include Roof m place and Windows
and Doors installed).
c
Notes: -7,-2-c-` - 'o,-' 7 , ,
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
• WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado.
APPROVEDDO NOT DESTROY THIS CARD
Bykx
IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC