Loading...
HomeMy WebLinkAboutOWTS Installation Observations 12.29.15ALL • l Four Wheel Drive Rd Carbondale, CO 81623 97G-l09·52S9 H~~l~f ~ I I ~ December 29, 2015 Mandy and Travis Tiffany Pfs625@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 3643CR233 Garfield County, Colorado Permit Number 3680 Travis and Mandy, Project No. C1183 ALL SERVICE septic, LLC observed the installation of the components outlined in our letter dated November 1, 2015, Recommendations for Existing Onsite Wastewater Treatment System (OWTS), on November 20, 2015. The excavation work was completed by Mountain West Contracting. Electrical work on the pump and control panel was completed by Walker Electric. Verification of pump and alarm operation was completed on December 29, 2015 by Ray's Well Done Pump Service, LLC. Completion of items verified on November 20, 2015: • Effluent filter installed in the outlet tee of the 1500-gallon septic tank. • Check valve in the pump line removed. • An 1 /8-inch diameter weep hole drilled in the pump line to allow for proper drain back into the tank after each dose. • The sewer line encased 10-feet on each side of crossing of water line. • Verified water line does not come within 10-feet of septic tanks. • Distribution box installed at the high point of the pump line with minimum 1 % grade for proper drain back. The distribution box is accessible from grade. • Speed Levelers were installed on each 4-inch diameter pipe exiting the distribution box. • 4-inch diameter SDR-35 pipes connect the distribution box to each trench. Existing 1.5-inch diameter pipe hanging from the underside of the chambers were not connected, but remain inside the chambers. • Inspection ports installed at the beginning and end of each trench. • It was verified that the water line did not come within 25-feet of the soil treatment area (STA). Completion of items verified on December 23, 2015: • Floats on the Goulds pump to discharge approximately 90 gallons per dose (on and off floats set 5 inches apart). • A CentriPro Model 510020 control panel installed within line of sight of the septic tank. Completion of items verified on December 29, 2015: • Pump tested and functional. • Alarm tested and functional. The OWTS components listed in the recommendation letter were generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC fLo-.. {a D&'f llt,~8 Carla Ostberg, MPH, REHS Pump line with proper drain back into tank Pump line encased within 10-feet of water line crossing I note rigid end caps 1l.::. Speed Levelers installed Inspection ports Control panel for pump ALL UI~~., 293.7' 4" DIA PIPE TO ENTERS TOP PORT OF CHAMBER. DOES NOT CONNECT TO 1.5" DIA LATERALS --- !OTOTAl. MC M>S CtW.llU<S • ''°SFOF »lflli.TRATIOH WaW• 155'.C...,...EJt t.$· '*PIPE ZJP.f1CD m THE eonou Of OCH lfF&.:ntAlOA 10 TIE ENOS. 11-4•tt0Lfs IH TOP Of 1 .s• N"E [VI: AT 6' .r TO [ACtt CN>OF 94f"a.t'RAfORRDW'. CAPS INSTAl.1.E:D AT aQTMEIClS CW: ... F' .. TRATORROWS DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LElTER DATED 12129115 33 Four Wheel Drive Road cart>ondale. Colotado 81623 PllOIMI 970.309.~9 caita@allservloeseplic:.a>m 4"DIAPIPES FOUNDATION ONLY --4· BEDROOM HOUSE COH1llQ. PNIQ. OH $m OI OtSUHCE -WATER LINE GRATER THAN 1G-FEET FROM SEPTIC TANK • • DISTRIBUTION BOX AT HIGH POINT. ACCESSIBLE AT GRADE EXISTING 1.5" OIA PUMP LINE HAS MIN. 1% GRADE TO DISTRIBUTION BOX AT HIGH ~.----~ .. -.v~u s p R/ HCS CHECK VALVE REMOVED. i· WEEP HOLE IN PUMP LINE FOR DRAIHBACK POINT -... ~· SEWER LINE ENCASED 10' ON EACH SIDE OF WATER LINE CROSSING 7PCtP .~INSPECTIONPORTS #f .~ INSTAUED ~ ~ttC.A..,f&.TRAJOAS I I / / /MINSO' J" TO TANK EXISTING M:'LL I I MIN100' TOSTA e (i)RECORO ORAWIN 0 G·"'" Tiffany Residence 3643 C.R. 233 RUie, Colotado 81650 Projecl Number. C 1183 N ~ ~ O' 25' 50' Scale: r a 50'-0'" Date: 12/29115 Designed By: CBO ReYiewed By: RHP ~By.ANG record Sheel I of I GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 401 --? Glenwood Springs, Colorado 81601-P ermit -> (&;;. 8' D Phone (970) 945-8212 A ssessor's Parcel No. INDIVIDUAL SEWAGE DISPOSAL PERMIT This does not constitute a building or use permit. PROPERTY Owner's Name 1/m &'/" Present Address ----------Phone 3' 7Cf'-2. (? .S-c; System Location Z./ 2 Z .3 ~cf= tJO /9:.S- legal Description of Assessor's Parcel No. _V _______________________ _ SYSTEM DESIGN I C-.S-o Septic Tank Capacity (gallon) _____ Other 2 tJ Percolation Rate (minutes/inch) Number of Bedrooms (or other) :?- Required Absorption Area -See Attached 7.35 S f. ,F/, //if 7X.£/iJCl/r 6/ t2-1-.s, O"' -v o s~ Pr ;// 15£'P -r 7cr ~-~ Special Setback Requirements : µ u o \ · · ~ :.S, Inspector _ __...,c---.J_,--:--_._/,,,_/1_1..__.,._k1 __ b~ .... (-c .... ...;.::._c:::-_c:>__..n/_,._ __ _ Date 7-7-/ S-- FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer _______________________________ _ Septic Tank Capacity _____________________________ _ Septic Tank Manufacturer or Trade Name----------------------- Septic Tank Access w ithin a· of surface------------------------ Absorption Area _______________________________ _ Absorption Area Type and/or Manufacturer or Trade Name ------------------ Adequate compliance with County and State regulation s/requireme nts-------------- Date ___________ lnspector ___________________ _ RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter25, Article 10 C.R.S. 1973 , Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements . Connection to or use with any dwelling or structu res not approved by the Building and Zoning o.ffice shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine - 6 months in jail or both). Wh ite -AP PLICANT Yellow -DEPARTMENT