Loading...
HomeMy WebLinkAboutStructural Inspection Report - Final 01.11.2016JAN 1 4 2016 1-11-16 WEST SLOPE TESTING & INSPECTION LLC 3177 Glendam Dr Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Page 1 of 1 Garfield County Building Inspection Dept. 108 8th St., Suite 401 Glenwood Springs, CO 81601 Please find enclosed special inspection reports for Metal Building 1434 CR 107. Thank You; Doug Young West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Final Inspection Report Report #2 Page 1 of 1 Date: 1-8-16 Project: Metal Building Rich Broadhurst (KRB Investments LLC) Address: 1434 County Rd. 107 Carbondale, CO Building Permit No: BLRE-10-15-3932 General Contractor: Tally Ho Construction Inspection of shop fabrication or field work at job site: Field Report: Inspected high strength A325 bolting at the Mezzanine level steel beam & column connections that were not yet installed & inspected on the 151 visit. Also randomly tested/verified A325 bolts were adequately tightened. The high strength bolting inspected above appeared to be in substantial conformance with the plans, and the AISC/RCSC Specification for A325/A490 bolting. To the best of my knowledge this completes the special inspections of the high strength A325 bolting, as outlined in reports #1 & #2 for the project. To the best of my knowledge no structural onsite welding was performed. Inspector/Technician: Douglas E Young Douglas E. Young Certificatio #510222 ctu 1 Wel ing S + lI s , : tor to St & Bo i : :al Inspector ray -applied Fireproofi , _ '�` i ecial Inspector Douglas E Young CWI 9G070131 QC1 EXP 7/1/2017 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #1 Page 1 of 1 Date: 12-10-15 Project: Metal Building Rich Broadhurst (KRB Investments LLC) Address: 1434 County Rd. 107 Carbondale, CO Building Permit No: BLRE-10-15-3932 General Contractor: Tally Ho Construction Inspection of shop fabrication or field work at job site: Field Report: Inspected high strength A325 bolting at the steel frame column & rafter connections. Also randomly tested/verified A325 bolts were adequately tightened. The high strength bolting inspected above appeared to be in substantial conformance with the plans, and the AISC/RCSC Specification for A325/A490 bolting. Note; there were a few high strength A325 grade bolts at the Mezzanine level steel framing that was not yet installed & would need to be inspected at a later date. Inspector/Technician: Douglas E Young Douglas E. Young C Certification . 102224 ctural eldi Specia r' tor e !' .; tee} Hokin int 1 spector 4p, ed Ft proofing S c' : I Inspector