Subject: Building Inspcctio t frit the mice( of Rodney Craasch, 6636 County Road 346, Silt. CO
81652 in Garfield County. Colorado
LOOK Buildings deti eloped the design for this building using the Engineered foundation plans
(supplied by others), the engineered roof system stamped by Mitek Industries, and the "Slurdi-
Lok" pre -manufactured shear wall system designed by us (Mitek programming used for design
parameters only), IBC fram ng codes (For length of unsupported material & bracing, etc.), and
previously engineered and stamped examples of substantial "Sturdi-Lok" wall panel systems of
similar design to this ur.e. Igo additional shear required (sheathing), unless specifically called out
by LOOK Buildings. An oversized continuous header is built into all panels and may be
penetrated for electrical wring within l' attach end with up to u 1 ' hole centered between plys.
Although this particular building has adequate shear huiit into all walls, plus addition of 29
ga. steel skin applied, the owner chose to add 7/16" sheathing to the exterior vial's for other
purposes. Sheathing should still be attached as per code with proper nailing pattern. Gang -
plating at base of structural panels used in conjunction with j -bolts & large washers for
hold-down in all areas contacting the floor.
LOOK I3uildings further supplies installation instructions and specifications for proper
attachment of all cornponents. A representative of LOOK Buildings will provide the appropriate
an -site inspection to ensure proper installation and provide documentation (tithe same at the
request of the inspector
in addition to information provided, it is at the discretion of the local building department ofalai
as to whether they would require i1 a owner to hire a licensed engineer for the state of Colorado
to further evaluate the wall system as presented. [hank you for your attention in this matter.
Cheek -List villeins
Anchored Properly
At least l Structural
Screw per 2' opening
1-7 VIP Attached properly
X -Brace & Purlins (4'o.c.)
Sincerely,
l
Brian W. ohnson
LOOK Buildings, LLC
1064 Main Si.
Deltu, CO 81416
(970} 399-6008 Ofiic
,f/tor Roof Sheathing (2' o.c.)
Ilurricane Clips Proper
' • Roll Blocks
WrapfUnderlayment
Metal Screw Pattern
If Wall Sheathing Specified,
check nailing pattern
7)."-'- (vs / 7' le' -0n 4`
• l 4v 5c7u7 [.pa 4 f7 f
Signed b ' epresentatire upon Inspection (if requiiredj`�7'�
PDF created with pdfFactory trial version www.pdffactorv.com