HomeMy WebLinkAboutFinal Installation Observations 01.26.2016ALL
SEAVICI
33 Four Wheel Drive Rd
Carbondale, CO 81623
970-309-5259
January 26, 2016 Project No. C1175
John and Jessica Miller
c/o Roger Giard
rgiarrd@rof.net
Onsite Wastewater Treatment System (OWTS) Installation Observations
Parcel 3, Roe Subdivision
Garfield County, Colorado
Permit No. SEPT -04-15-3627
John and Jessica,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on December 11, 2015 for the subject property. KEG Enterprises, LLC (Kurtis Greenman) installed the
system.
The installation included a new 1250 -gallon, two-compartment Valley Precast concrete septic tank with
an Orenco® Biotube Pump Vault and Orenco® PF3005 pumping system in the second compartment.
The control panel for the pump was installed within line of sight of the septic tank. Valley Precast
personnel conducted start up of the pumping system on January 22, 2016.
A clean out was present between the house and the septic tank. The inlet tee was installed in the septic
tank. There is an effluent filter inside the second compartment of the septic tank. This filter must
be cleaned annually, or as needed.
Effluent is pressure dosed through a 1.5 -inch diameter pipe to an Orenco® model 6402 automatic
distributing valve (ADV), and then to two gravelless chamber beds, each with three rows of 13 `Quick 4'
Infiltrator® chambers, for a total of 78 chambers and 936 square feet of infiltrative area. The chambers in
each bed are connected by a 1.5 -inch diameter level manifold. Laterals run the length of the chambers
and are 1.25 -inches in diameter, hung with zip ties from the underside of the chambers. The laterals
have 5/32 -inch diameter orifice holes facing up, with the exception of the first and last holes facing down
for drainage. The holes were placed 3 -feet on center. Each lateral ends in a 90 degree ell facing up with
a ball valve for flushing. Valves were placed in a valve box and were accessible from grade. Inspection
ports were placed in all four corners of each bed.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
(Vol, (eL OV -&As
Carla Ostberg, MPH, REHS
Reviewed By:
Septic tank
Inlet side of septic tank
Inlet tee installed
Pump installed in Biotube Pump Vault
Control panel within line of sight of septic tank
Control panel
Chamber bed
Laterals before being zip tied to chambers
Manifold
Manifold
Chambers after backfill
Flushing vaives in vaive boxes, accessible from grade
Automatic Distributing valve
o W o
)v
o 0
m
v (00 o
v
a) W m
o
0.co0
cp
N
(D v
-6 (0 0-
0
w
0 rn
N
co
peoH eApa IaaLIM anod ££
SLL LO :JagwnN loafoad
W
C)
n) 0)
m o
o�
o c
0-
D Q
c.
n o
O D
m
n) x
0. 0
0 3
0
0
eouepseJ Jeff! N
96/9Z/t-0 :a}ea
0)
0
0
0
CD
O
^i
ONIM` CI a1003?J
82138kWH0 8L = 82138kWHO
O
c
n
0)
H
D
Z
p
D
70
p
038 HOV3
NO1103dSNI `d10 x,17
010dINb'W
O 0n O
D z
m H
pw >
D n 0
n
w = m
0 U)
I o W
m
C W
r m
mm
<r H
m
m
HOIH 1`d Z0179 13001A1 AQV
zz Z
w w w
co (
co N N N
rn rn rn
w
CO 1 01
co cn
Z
w
N
w
0,
y
Z
w
co
N
rn
0,
0)
Co
ao
w
O
w
00
0o
CO
0 z
O�
H�
D r
z0
m
m
m
0
ci
p
ci
D
Z
3N1-1 dLfld 017 -HOS d10
w
CO
w
00
0,
:S31b'NIa21000 SdO
O 01
Z
^
l J n
m
D
m O
-HZ
Z -H
O
n
= O
Om
� D
m�
z
0
Om
z
H
S2138VVVHO ,17)10Il0, 8L 1v101
co —1
00
o
en 7:i
Q m --
-
pm
c_ c/)
C70
T� I
4, D
�
I W
m
07
m m
p
(
z
m
D
0
I
co
m
p
p
z 0
m
or
ef)
r
Om
m mm
O 0
Dm
D
Z
� Z
O
c
H
H±IM 3N1-1 213M3S b10
I—
>O
U) O G)
Cn c
c m
o
>
D
m0 D m
lj
m1:13 0 D
p Z
11D m
i
11 >
ao
rn o m
W
m
'co >
11
11
II N O
0ow
w cr
o G)
cn m D
m
0
m
H
0)
0
F
H
m
D
H
m
Z
H
D
cJ
m
D
0)
H
D
.,0-.0Z = .,6 :81eoS
ccs
m Tz
1 x /\
N
0
D c0
7q
O2:)
z m
�m
Z
OO
n Z
O
D
H
m
Z
H
H
D
Z
H
I
m
c
m
SNOTVO 006 'N11/N1 = 3WI
SNO11VO 0917 = MOld 2131VM31SVM
(14
01 CO
Om
v
Dlb O
E
W
O m
Z
ov
Z
x C)
Iv m
m
m
O
Z
(�
w
m
0
Z7
O
0
x
w
w
m
0
0
0
r)
N CN)
p'Hwv,
I -p
Z`rZ01m
Po
CN0D'.
p®D'Q,0
w D _
-.0 n
n n
z
Project Address
Garfield County
Community Development Department
108 8th Street Suite 401
Glenwood Springs, CO 81601 -
Phone: (970)945-8212 Fax: (970)384-3470
Parcel No.
Permit NO. SEPT -4-15-3627
Permit Type: Septic Permit
Work Classification: New
Permit Status: Active
Issue Date: 5/8/2015
Expires: 05/07/2016
Subdivision
Section
Township
Range
TBD CR 319
RIFLE, CO
240313300057
Owner Information
Address
Phone
Cell
John & Jessica Miller
405 Will AVE
Rifle CO
(970)379-3355
405 Will AVE
Rifle CO
Contractor(s)
Phone
Primary Contractor
Giard Homes Inc
(970)230-1536
Yes
Proposed Construction / Details
new OWTS for new s/f dwelling
FEES DUE
Fee Amount
Percolation Test
Septic Fee - New
Total:
$150.00
$123.00
$273.00
Valuation:
Total Sq Feet:
$0.00
0
FEES PAID
Inv Total Paytype Amt Paid Amt Due
Inv # SEPT -4-15-23527
$273.00 Credit Card
$273.00
$0.00
Required Inspections:
For Inspections call :
1(970)945-1377
ext 1621
Inspection
IVR
See Permit Record
Building Department
Copy
Friday, May 8, 2015
2
Do Your Part, Be SepticSrnart:
The Do's and Don'ts of Your Septic System
Learn these simple steps to protect your home, health, environment and property value:
septicsmart
U.S, Environmental Protection Agency
'kr
0 446,
Do:
• Have your system inspected (in general) every three years by a licensed contractor
and have the tank pumped, when necessary, generally every three to five years.
Think at th
Don't:
• Pour cooking grease or oil down the
sink or toilet.
• Rinse coffee grounds into the sink.
• Pour household chemicals down the
sink or flush them.
Do:
• Eliminate or limit the use of a garbage
disposal.
• Properly dispose of coffee grounds a
food.
• Put grease in a container to harden
before discarding in the trash.
Don't:
• Flush non -degradable products or
chemicals, such as feminine hygiene
products, condoms, dental floss,
diapers, cigarette butts, cat litter, paper
towels, pharmaceuticals.
Do:
• Dispose of these items in the trash can!
Don't:
• Park or drive on your drainfield. The
weight can damage the drain lines.
• Plant trees or shrubs too close to your
drainfield, roots can grow into your
system and clog it.
Do:
• Consult a septic service professional to
advise you of the proper distance for
planting trees and shrubs, depending on
your septic tank location.
L
Don't
• Concentrate your water use by using
your dishwasher, shower, washing
machine, and toilet at the same time.
All that extra water can really strain
your septic system.
Do:
• Stagger the use of water -generating
appliances. This can be helpful
especially if your system has not been
pumped in a long time.
• Become more water efficient by fixing
plumbing leaks and consider installing
bathroom and kitchen faucet aerators
and water -efficient products.
For more SepticSmart tips, visit: www.epa.gov/septicsmart
UEFA 832-R-13-002 • September 2013