Loading...
HomeMy WebLinkAbout7.0 Email on WaterlineFred Jarman From: Dion Pisek idionplsek@cordcomp,com] Sent: Monday, August 02, 2004 10:26 AM To: Fred Jarman Cc: Jimmy Smith (E-mail) Subject: FW: Water Line Importance: High Fred, rage 1 or Z Please refer to the statement below for information on the water line valves. The alignment drawings show the vent valve locations in the second row (marked "Crossings") from the top of the page. I will forward the vent valve schematics to you in a subsequent message. Thanks, Dion Plsek, P.E. Associate Engineer Cordilleran Compliance Services, Inc. 826 21'/2 Road Grand Junction, CO 81505 Phone = 970.263.7800 Fax = 970.263.7456 Mobile = 970.270.0278 www.cordcomp.com Original Message From: Bronte Consulting [mailto:bronte_egr©msn,com] Sent: Monday, August 02, 2004 9:34 AM To: Dion Plsek Cc: Chuck Bucans; David Grisso - EnCana; Mike-Hayde-Encana ROW,; KristinF-Encana Subject: Re: Water Line Importance: High Dion: The line has 10 buried vent valve locations as indicated on the alignment sheets, the only other above ground valve set will be located on the Lazier property -- EnCana made an agreement with the landowner to supply water to the new development from the River Water Line. The only other valves will be located at the Pump House -- there no other above ground valve sets along this line. 1 will forward you a copy of the drawings for the vent valve installations. «<JC»> John E. Corrent - President Bronte Consulting, Inc. 10224 Loridan Lane Sandy, UT. 84092 801-942-8130 (0) phone/fax 801-673-5283 (M) This transmission & any accompanying documents contain information belonging to the sender which may be confidential and legally privileged. This information is intended only for the use of the individual or entity to whom this transmission was sent. If you are not the intended recipient, any disclosure, copying, distribution or discussion of these materials, or action taken 8/2/2004 in reliance on the contents of the information contained in this transmission is strictly prohibited. If you have received this transmission in error, please delete the transmission from your files. Original Message From: Dion Pisek To: John E. Corrent (E-mail) Sent: Monday, August 02, 2004 9:24 AM Subject: FW: Water Line Do you have any information on this? The county hearing is today, so I need to know where & how many on the valve sets or get some drawings by this morning. Thanks, Dion Original Message From: Fred Jarman [mailto:fredjarman©garfield-county.com] Sent: Monday, July 26, 2004 10:17 AM To: Dion Plsek Subject: Water Line Hello again, I also need to know how to locate the above ground valves on the plans. Any ideas, thanks. Fred A. Jarman, AICP, Senior Planner Garfield County Building and Planning Department 108 8th Street, Suite 201 Glenwood Springs, Colorado 81601 970.945.8212 My Inbox is protected by SPAMfighter 715 spam mails have been blocked so far. Download free SPAMfighter today! 8/2/2004 O CD GRADE +EI--11-1H 1-+H- 311-11f -1Fl_TTh 111�I-1.1---IfI-1II- 111-� I I I f 111 III ��T_111111111111 11-�1 I I- II 1 1 1 1 -III III_ 111" _ -f1I111-11I- 111.-IIIIII1111 .1117:a_-1- 11=f I 11I =III=1 I�1= I=161- I 111-111'. II11 111--1 1=111=1 I I=�1 I I M1111_1 11- 8" ANCHOR FLANGE, STD. WT - MATERIALS LIST ITEM QUAN. 01 01 02 01 03 01 04 05 06 07 08 09 01 01 01 01 01 DESCRIPTION 8" ANCHOR FLANGE, C. 4" TO 2" CONC. RED, Sl 8" ANCHOR FLANGE 7 2" THREADED BALL VAI 2" VENT -O -MAT 050 RB; BRONTE/TMC VALVE 8" x 4" RED. TEE, CS, Si 4" PIPE, STD. GR. B 2" PIPE NIP., CS, SCH. 8 41 0" C� -0--- 1111 111=1 STD. GR B P. W! CONCRETE THRUST BLOCK E, BRONZE 2521 NCLOSURE ., GR. B - 1�111111��I. 111 IllbH1 - 1=111 111 11.1= REV. 07119!04 REVISED FOR RIVER PIPEINE INSULATION ALL SIDES AND LID 2" VENT -O -MAT 050 RBX 2521" 2" THREADED BALL VALVE, BRONZE 2" NIP TOE, SCHD. 80, GR B 4" X 2" CONC. RED., STD., GR B 4" PIPE, CS, STD, BE, GR. B ,TOE " X 4" RED TEE, CS, STD., ¥-52 \ NOT TO SCALE 8" LINE PIPE, SEE ALIGNMENT SHEETS FOR SCHED. Llat Update Authorization here. Approved By: owm: SBW JC/CB/FTM JC rmw.b,a DDIMMt'Y 07/19104 07/19/04 07/20/04 BRONTE CQNSULTING STAR VE LLEY ENGIN EENING TED MILLER CO.. INC_ ENCANA OIL & GAS (USA), INC. RIVER WATER PIPELINE 2" HIGH POINT VENT VALVE RIFLE, COLORADO H. P. VENT VALVE 7-19-04 c�e:xx:)04 JOB NUMBER 9994-C SHEET 1 OF 1 GRADE =11-1 +H-.1+1. _ .+I_ �II=111 -ITI�I 111=Itflt 1 +-11111111111E-1 11 I-IS 111111 E11.1 1 1L - .I l .- I I _ 11111111114 Ili -111.- -1111711171 --,1111111_=11 1II III 11111 =111-1111 !-I I I= --111-i 111-111-11 G- 8" ANCHOR FLANGE, STD. WT MATERIALS LIST ITEM DUAN. 01 01 02 01 03 01 04 01 05 01 06 01 07 01 08 09 01 10 01 DESCRIPTION 8" ANCHOR FLANGE, C 4" TO 2" CONC. RED, S 8" ANCHOR FLANGE 2" THREADED BALL VA 2" VENT -O -MAT 050 RB BRONTEITMC VALVE 8" x 4" RED. TEE, CS, S 4" PIPE, STD. GR. B 2" PIPE NIP., CS, SCH. 8 2" X 1" RED. BUSH, CS, STD. GR B P. W/ CONCRETE THRUST BLOCK E, BRONZE 2521 NCLOSURE , GR. B 4' 0" LREV. 07/19/04 REVISED FOR RIVER PIPEINE_ INSULATION ALL SIDES AND LID GRADE --SII 11111 :III -11 f =111=1 11-. 111-f I I_=11=TI=1 IJ LI =! 1=111J1I�I 61.=J fJ�1L- 1" VENT -O -MAT 025 RBX 2521" 2" X 1" RED. BUSHING, CS, THD. 2" THREADED BALL VALVE, BRONZE 2" NIP TOE, SCHD. 80, GR B 4" X 2" CONC. RED., STD., GR B 4" PIPE, CS, STD, BE, GR. B 9 - 8" X 4" RED TEE, CS, STD., Y-52 1� ,TOE HD. NOT TO SCALE 8" LINE PIPE, SEE ALIGNMENT SHEETS FOR SCHED. List Update Authonzatlon here. Approved By, Diann JC/CB/FTM SBW JC Ronan 3; DD/MM/Y!' 07/19/04 07/19/04 07/20/04 RRONTE CONSULTING STAR VEL LEY ENGINEERING TED MILLER CO., INC. ENCANA OIL & GAS (USA), INC. RIVER WATER PIPELINE 1" HIGH POINT VENT VALVE RIFLE, COLORADO PJ H. P. VENT VALVE 7-19-04 R"°' 1 b:xx: xxT-JOB NUMBER 9994-C LSHEET i OF i