Loading...
HomeMy WebLinkAboutApplication - PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Offlce :970·945·8212 Fax: 970·384-3470 Inspection Line: 970·384-5003 Building Permit No. \0~70 Parcel No : 2395-153-12-009 Locality: Oak Meadows Ranch 4th 2nd AMD, Lot 9 ------~-------------- Job Address: 0129 Old Midland Dr, GWS Use of Building: s/f dwell ing on crawl space w/patios & attached garage ------------~-------~--~--------~~-------- Owner: Wittenberg , Ke ith Contractor : Owner Fees: Plan Check: $ 969 .60 Septic: Bldg Permit: $ 1,492.15 rd inpact fee Area BE: $ 1,982.92 Total Fees: $ 4,444 .67 Clerk: ~ Date: LQ\~ \U( I 2 3 4 5 6 7 8 9 10 II 12 GARFfELD COUNTY BUILDING PERM IT APPLICATION 108 81h Street, Suite 401, Glenwood Springs, Co 8160 1 Phone : 970-945-82 12 I Fax : 970-384-3470 I Inspection L ine : 970-384-5003 \\'\\w.garfic ld-cou nty.com Lot No: \ Block o : ev.tft~ RXf m Contractor: Architect I J;ngineer: A vv-t ":t. i ~)(/(_ Use of Bui lding: Describe Work: +· \ ( 'O"'ve"' 10 ~ Class of Work: ~ew Garage : Driveway Permit: Mailing Addrest l l.'\ OlP\ Mailing Address: o A lt erat ion Septic: Ph: o Addition oiSDS Owners valuation of Work : NOTICE Alt Ph: Alt Ph : Aurh or!ly. This applicali on for a Building Penni! musr be signed by rhc Owner of rhc property, de sc ribed Above, or an aulhorized agent lfrhe signar urc below is norrhar of the Owner, a separale lener ofaurhority, signed by lh e Owner, musr be provided wirh this Applica rion. lgal Asrrn. A Building Pemlir cannor be issued wirhour proof of legal nnd adcquarc access ro rho propeny for purposes ofiuspec1ions by lhc Building Department Olhtr Psrmjls. Mulliple separale pennits may be required : (I) Slale Eleclrical Penni I, (2) County ISDS Pennit, (3) another penni I required for use on the propelty idenli fi ed above, e.g. Srale or Coun ty Hi ghway/ Road Access or a Slale Wastewater Discharge Permit Void Ptrmlt. A Bui lding Penni! becom es nu ll and void ifrhe wo rk aurh orized is nor co mmenced wirhin 180 days ofrbe dar e of issuance and if work is suspended or abandoned for a period of 180 days afler commencem ent CERTIFI CA TION I hereby certifY rh at I hove read rhi s Appl icolion and thatrhe informarion con roined above is lrue and correct I undersl and lhal the Building Departme ul aecepls rhe Applicali on, along wilh lhe plans and specificalions and olher dara snbmilled by me or on my behalf(submi uals). based npon my certificalion as lo accuracy . Assuming comple reness ofrhe submillals and approvAl ofrhis Applicarion , a Building Pernlir wi ll be issued gran ling permission lo me, as Owner, lo construcr rhe srructure(s) ar•d faci liries derai led on lh e submillals reviewed by lh e Building Department In considerali on oflhc in uancc ofrbe lluilding Pernlit, I agree th ai I and my Bjl,enls will comply wilh provisions of any federal , slale or local law r<gulatin g th e work and rhe Garfield Counry Building Code, ISDS regular ions and applicable land use regular ions (Counry Regulari on(s)). I acknowledgclhallhe Bui lding Pennit may be suspended or revoked, uponnolice from the County, if the location, con srrucrion or use ofrhc slrucrure(s) and facility(ies). described above, are nor in compliance wilh Counry Regular ion(s) or any other applicabl e law. I hereby gra111 permission lo rhe Buildin g Department lo enter the proper!)', described above,lo in specl the wo rk. I further acknowledge !hal l he iss uance ofrhc Building Pem1il does nor prevenllhe Building Official from : (I) req uiri ng I he correction of errors in th e submillal s, if any, di scovered after issuance; or (2) stopping con sr ru crion or use of the srrucrure(s) or fac ility(ies) ifsueh is in viol ari on of Counly Regular ion(s) or any olher applicable law . Review oflh is Appl ica lion, including submiltal s, and inspeclions ofthc work by I he Building Departmenl do nol constirure an acceplancc o frespon sibili ry Of liability by the County of errors, omissions or di screpancies. As the Owner, I acknowledge I hal responsibility for compliance with federal, slale and local laws and Counly Regularions rcsl wilh me and my authorized agenls, including wirhoul limirarion my archilec l design er, engineer and/ or builder. I HEREBY ACKNO WLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & C£RTI FI C ATION ABOVE: DATE STAFF USE ONLY Special Conditions: Adjus ted Valuation: \{5 ~6 Plan Check Fee: Manu h ome Fcc: q \f\ 1,.0 Balance Due: Setbacks: OCCGroup: BLDG DEPT: PLNGDEPT: -o Y A PPRO The following items are required by Garfield County for a final Inspection: I) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readi ly visible from access road . 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a comp lete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with w ashbowl, tub or shower, toilet, hot and cold runn in g water, non-absorbent floors , walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to aiiiBC and IRC requirements in cluding guardrai ls. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks , grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final in s pection sign off by the Garfie ld County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire Di strict , and/or State Agencies where applicable. 5 {xtf l' v\ ') 1 o'"" ex c7 f- A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occ upancy, use and the issuance of a C .O . for the building identified in the Building Permit. DATE VALUATION FEE DETERMINATION Applicant Address Date .,:W.:,I:,::'tt:::en:;:b::.:u::Jrg'"::-::-"'7":::-------Subdivision 0129 Old Midland Dr. Lot/Block .::5c;,/2?::8C::/2:o=;O;:O:,e8====------Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation 1035 sf 1210 sf sf sf X $74.68 2245 sf sf X $41.00 sf X $33.68 525 sf X $18.00 1035 sf X $9.00 sf X $24.00 152 sf X $12.00 Commercial sf X sf X sf X sf X sf X sf X Oak Meadows 9 Owner 167,656.60 0.00 9,450.00 9,315.00 1,824.00 0.00 188,245.60 PLAN REVIEW CHECKLIST Applicant W ±\ ~ bw G Date __ S"_-~?:__,?'----0_..;::;_8' __ Building ~gineered Foundation -.v-Driveway Permit fE.j{~ ---l,LSurveyed Site Plan ~Septic Permit and Setbacks L-~ L/ Grade/Topography 30% ~ttach Residential Plan Review List V Minimum Application Questionnaire /subdivision Plat Notes J1/_7e Department Review __J_ Valuation Determination/Fees 0 ed Line Plans/Stamps/Sticker A Attach Conditions L Application Signed V Plan Reviewer To Sign Application _d.Parcel/Schedule No. ~ 40# Snowload Letter-Manf. Hms. ' / Soils Report - GENERAL NOTES: Planning/Zoning v/Property Line Setbacks '-3oft Stream Setbacks ~Zoning Sign-off ~Road Impact Fees ~HOA/DRC Approval ~effopography 40% ~~nglssues __t.L'subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes X 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes X 3. Does the site plan include when applicable the location of the !.S.O.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes X 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes X ' 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-860 I. See phone book for other agencies Yes )< 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes X 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes )< No ____ _ 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes X No ___ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes X 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes __ .<,._:, __ _ II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X I2. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes_~'--"~--- I3. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes X 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No_~X_. _, ___ _ 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes ___________ No __ _L~~-------- 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes K 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ------"----'>--- 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes ~ No ____________ _ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes X 20. Do you understand that if you are building on a parcel ofland created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes X 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes X 22. Will this be t11,e _only residential structure on the parcel? Yes 2::_ No Ifno-Explain: ____________ __ 23. Have two (2) '(gJTIPlete sets of construction drawings been submitted with the application? Yes __ __,/"' ____ _ 24. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes X 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes X 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone districXt? Yes. ____ ~-------- 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes )< 28. Do you understand that approval for design and/or construction changes are required prior to the application ofthese changes? Yes Y 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road I.nwact" or "Septic System" fees required, at the time you pick up your building permit? Y es. __ .:_X_;__ __ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes )< No _____ _ 3 I. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-il!§Pection fee? Y es. _ ____,l"c___ __ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes X ' 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes )( ' 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable i~p;ction. Yes X ------------------ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel /Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated . Yes )Z 36. Do you know that the local fire district may require you to s ubmit plans for their review of fire safety is sues ? Yes )( (please check with the building department about this requirement) 37 . Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes X 38. Are you aware that if you will be connecting to a public wa ter and/or sewer system , that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate ofOccupancy? Yes X I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Date Phone: ~W 0\. '-\ ~ "S \ q\ ""'-~-() ~ ~'{>) 3U> \ (evenings) Project Name : kft tf-~b e,-f'J Project Address: D \ "'L-~ oVA r e s ~o\ e--"-C-t..- f/\IA~""tl\ Dr bW 5 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 7 JUN -05-2008 12:10 From :HP -G EOTE CH 9709458454 ~tech FAX TRANSMITTAL FORM DATE: fr5-0~ FROM: ~ {vv. ""'J NumberofPages: ____ ·~~~~---------- Uncluding this page) MESSAGE: 'So ; .I r2-e-f u ( t The original of this transmittal will be sent by: ¥- Ordinary Mail '$!1 Fax Only m To :3843470 HEPWORTH • PAWLAK GEOTECHNICAl, INC . 5020 County Road 154 Glenwood Springs , Colorado 81601 Phone : 970-946-7988 Fax: 9 70-945-8454 a-mall : hpgeo@hpgeotech .c om PROJECT NO.: /0 ~ 2,.t34 FAX NO: 3 t'--/ ~ '+ ]0 Overnight '$!1 Other 'ii'D The information conta ined in th is fa csimile me ssage is confidential and inten ded for the sole use of the individual named above . If you are not the intended rec ip ie nt, received this communication in error, or if problems occur with tra nsmission, please notify us at 970-945-7988. Sent a·y: --------------------------------------------------------- JUN-05-2008 12:10 From:HP-GEOTECH 9709458454 To:3843470 HEPI\URl H PAWLAK GEOTfC HNI( .11 I' May 23,2008 Keith Wittenberg 0129 Old Midland Drive Glenwood Springs, Colorado 8 I 601 .Job No. I 08 213A Subject: Observation of Excavation, Proposed Residence, Lot 9, Filing 4, Oak Meadows, 0129 Old Midland, Garfield County, Colorado Dear Keith: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the excavation at the subject site on May 19, 2008 to evaluate the soils exposed for foundation support. The fmdings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you, dated May 6, 2008. Hepworth-Pawlak Geotechnical previously performed a geologic site assessment and preliminary geotechnical study for the Oak Meadows Filing 4 development, submitting our findings in a report dated April 15, 1998, Job No. 196 420. The residence will be a two story wood frame structure over crawlspace. The attached garage will have a slab-on-grade ground floor. The building has been designed to be supported on spread footings assuming an allowable soil bearing pressure of I ,500 psf The ground surface of the Jot has a strong slope down to the northeast. At the time of our site visit, the foundation excavation was nearly complete and had been cut in one level fi·om about I to I 0 feet below the adjacent ground surface. The eastern side frost trench for the footings had not been dug. The soils in the bottom of the excavation consisted primarily of stiff, sandy silty clay. In the shallow cuts along the eastern side of the excavation, there was some black topsoil at subgrade. Results of swell-consolidation testing performed on a sample of the silty clay, shown on Figure I, indicate the soils are moderately compressible under conditions of loading and wetting. JUN-05-2008 12:10 From:HP-GEOTECH Keith Wittenberg May 23,2008 Page 2 9709458454 To:3843470 P.Y6 The laboratory testing is summarized in Table I. No free water was encountered in the excavation and the silty clay soils were generally moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soils designed for an allowable bearing pressure of I ,500 psf can be used for support of the proposed residence. The soils may tend to compress when wetted which could result in some post- construction movement of the foundation and precautions should be taken to prevent wetting. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for columns. All topsoil and loose disturbed soils in footing areas should be removed to expose the stiff silty clay soils and the sub grade should be compacted prior to placing footing concrete. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be well reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for on-site soil as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind the crawlspace walls and wetting of the lower level. Structural fill placed within floor slab areas can consist of the on-site soils, excluding topsoil and oversized rocks, or base course, compacted to at least 95% of SPD (standard Proctor density) at a moisture content near optimum. Backfill placed around the structure should be compacted to at least 90% SPD and the surface graded to prevent ponding within at least 10 feet of the building. Landscaping that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within 5 feet ofthe foundation. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In Job No. 108 213A JUN-05-2008 12:11 From:HP-GEOTECH Keith Wittenberg May 23,2008 Page 3 9709458454 To:3843470 order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommend at ions contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, DAY/vad attachments Figure I, Swell-Consolidation Test Results Table I, Summary of Laboratory Test Results JobNo.I08213A JUN-05-2008 12:11 From:HP-GEOTECH 9709458454 To:3843470 Moisture Content = 19.5 percent Dry Density = 102 pcf Sample of: Sandy Silty Clay From: Bottom of East-Central Portion of Excavation 0 ---1 r--. ' ~ No movement upon '* 2 wetting c: ........ 0 "" 'iii Ul ~ 3 c. \ E 8 4 \ 5 0.1 1.0 10 100 APPLIED PRESSURE-ksf 108 213A 0~ HHPWOR'ni•PAWLAK GHO'T'II:CHNICAL SWELL-CONSOLIDATION TEST RESULTS Figure 1 SAMPL£ LOCATION NAlURAL NAlURAL IN BOTTOM OF MOISTURE DRY EXCAVATION CONTENT DENSITY (%) (pet) East -Central 19.5 102 Northwest Comer 19.3 91 HEPWORll+PAWLAK GEOTECHNICAL, INC. TABLE 1 SUMMARY OF LABORATORY TEST RESULTS GRADATION PERCENT ATTERBERG UMITS GRAVEL SAND PASSING UQUID PLASTIC NO. 200 UMIT INDEX (%) (%) SIEVE (%) (%) Job No. 108 213A UNCONFINED COMPRESSIVE SOIL OR STRENGTH BEDROCK TYPE (PSF) Sandy silty clay Sandy silty clay "e; ~ ' IS) Ul ' :;g IS) OJ " ' 0 3 I -u ' GJ rn 0 ~ rn () I -u "' ' "' KURTZ & ASSOCIATES, INC. STRUCTURAL CONSULTANTS 5012 County Road 154 Glenwood Springs , CO 8160 1 Dat e: October 07, 2008 MEMORANDUM To : Garfield County Building Department Re : Wittenberg Residence: Lot No.9, Filing 4, Phase I, Oak Meadows Subdivision, Garfield County, CO. Phone (970) 945 63 05 Fax (970) 945 I 0 93 Note that our office is the structural design engineer of record for the subject residence . Note that our office has not performed an on-site inspection of the residence . We understand that a representative of the Garfield County Building and Planning Department inspected and approved the concrete footings and footing reinforcement prior to placement of concrete for the footings . We also understand , based upon statements from Keith Wittenberg , that the grade wall reinforcement for the foundation grade walls was in accordanc e with the construction documents issued by our office . We understand that the reinforcement was placed in accordance with those docum ents to include placement of ' corner ' bars at the wall corners, and to include app ropriate lap lengths for the horizontal bars (24" minimum lap length). Note that the typical grade wall height is 3 '-4", and typical wall reinforcement was specified as #4 vertical @ 16" on center, (2)-#5 horizontal , top and bottom of the grade wall , and (2) -#4 horizontal intermediate . This specified foundation wall reinforcement is structurally adequate and appropriate for the soil conditions and building design loads. The foundation system constructed in accordance with this specification is structurally adequate and safe . KURTZ & ASSOCIATES. INC. STRUCTURAL CONSULTANTS 5012 County Road 154 Glenwood Springs, CO 8160 1 Date : October 07, 2008 MEMORANDUM To : Garfield County Building Department Re : Wittenberg Residence: Lot No. 9, Filing 4, Phase I, Oak Meadows Subdivision, Garfield County, CO. Phone (970) 945 6305 Fax (970) 945 1093 Note that our office is the structural design engineer of record for the subject residence . Note that our office has not performed an on-site inspection of the residence . We understand that a representative of the Garfield County Building and Planning Department inspected and approved the concrete footings and footing reinforcement prior to placement of concrete for the footings . We also understand, based upon statements from Keith Wittenberg, that the grade wall reinforcement for the foundation grade walls was in accordance with the construction documents issued by our office . We understand that the reinforcement was placed in accordance with those documents to include placement of ' corner' bars at the wall corners, and to include appropriate lap lengths for the horizontal bars (24" minimum lap length). Note that the typical grade wall height is 3 '-4", and typical wall reinforcement was specified as #4 vertical@ 16" on center, (2)-#5 horizontal, top and bottom of the grade wall , and (2) -#4 horizontal intermediate . COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at OI::Z9 O.!b(~ Permit No. ----'-'/ 09""----'---'7'-'0""---------------- I have this day inspected this structure and these premises and found the following corrections needed: CaU for Re-lnspectlon D $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /-'2-~9' 20f--------:-- Building Inspector ~ Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone(970)945-8212 Job located at cY/Z2 0/0 /ttllZL/JKO Permit No. / e> 7' z CJ I have this day inspected this structure and these (J) premises and found the following corrections needed: &st 1 /II Kl re-dEAl /1/;qcps-!3'<" o~~_o , Tc3 §!CApt /N C,tfAt.UL.s;;r'Ace, (£; ~A/11.5 CALL EOR. II J;f ,;lO;.s/'"S ClV/&;f: A/bo!<_ /{/.:?/ ZXB 6'A1 v/2;;: (J) /{/(£££? ,rbs-;-;:; d/Vo;z:.e G-1/;PIZ.IZ. (!£) Z:Rtl.s..s t=:s. ·i-.?e""ff.c ~ /A'C...-?1 /J<t/ss Cc?, APPI?.E.;s-s-wG-d£c/IAM.cAL tl'/1111 v 1 &-;A/ c.o o / :s ·_e (:;!ji7~/.fl Tc::> S££ ,4/Ml</J'S4c7VA(ZA: t/YS/AL<- aJ £71[; <... rb ,;e W/;1/CJou.J5-,t::"ZI(..s,)( //110--t w4;q771tZ:i? .. /X'oo/'""hi'JG-~ ~or Re-lnspection D $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /4;:7-7 20 c:> 3" Building Inspector C:2 .;;_, ~~,.-...__ Phone (970) 945-8212 .· COuNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at --'0""'--'-'1<?"'. _Lc;_____...c&'--'"'-::__/_L7;:._:~--". =""·~=~"-'~'---- Permit No. 10970 I have this day inspected this structure and these premises and found the following corrections needed: -~ . 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 9-/9'-0fj:' 20_--=--- Buildinglnspector ~~< ' Phone (970) 945-8212 COUNTY OF GA~FIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Permit No. lt277tJ ' . I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 6 -~ 20 ...:0=.56~- Building Inspector --~~~~_.,__~:~· :!=__~~::!,-~0"'~~~~· ==-==----- Phone (970) 945-8212 ~ No. _ __ _ __ 1,_,0,.9-'-'70,.__ __ Assessor's Parcel No. 2395-153-12-009 Date 6/4/2008 BUILDING PERMIT CARD Job Address __ _,OOLJ1 .... 2..,9wO..,I""dwM.IU.U.idwla..,n:nd.......,DLr . ...,G""Wu."'S'-'O""-a...,k.......,.M.,.e..,a...,d""o""w...,suR~a...,n_..c.._hL.:4:z.~twhu2 .... n ... d..,AI:1M.....,O .... , .._t ... o.._t ..,_9 ________ _ Owner ____ --'W......,jtt..,e .... n .... b..,e.._r"'. K ..... e,..j...,th'-'------Address 129 Old Midland Dr GWSPhone # 970-948-3101 Contractor ___ ....;O=-w=n=-e,_r ----~----Address _____ =.s~am=e ___ Phone # 970-274-1344 Setbacks: Front _____ Rear _____ RH _____ LH _____ Zoning ____ _ s/f dwelling on crawl space w/patlos and attaiNSPECTIONS Soils Test Weatherproofing ____________ _ Footing '-' -..s-:= tt:> E? ~ • Mechanicai ______ -:;:;::--::--::::----=--- Foundation .t!??.eed ~~~u--. Electrical Rough (State) q.. Z 3 -o8 Grout . Electrical Final (State) I.:....Z:-o9 b Underground Plumbing Final /-/.3-o? /Checklist CompJ.eted? ~ Rough Plumbing 2-19·-o!("'if?1:nt Certificate Occupancy# _(._.t..._2'-'ID'""'-__,1 _____ _ Framing kr1--ot~ Date l S'S.UET.=> l·!"'l(;"'j Insulation /0·/7~ Septic System # ____________ _ Roofing Date -------------~:'~:~in:t?9~~~e~ /~ other Final ____________ _ NOTES (continue on back) BUILDING PERMIT Date Issued lQ I Y I Q~ GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Permit No. _ _._f.,.Qq'-L1_._,Q~------- AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Use ¥aw fRCtvl ytue ustl2tilli5 f> aHeufld Cj@(Je Address or Legal Description CJ/21 O(cl /nldluflr/ elY-(-zu.B Owner Wl/k11/Jf£f), i:'t!,J./; Contractor__..al"''{?I!~IJ'-'-~-=-r'----------­ Building Permit Type --L/1"-'~"'~"'-"d."'~""'/1."-T'-';""-'G"'--~~~~~~~~~~~~~~~~~~~~~~~~- This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway (-,-~ -o55 CJ.J£1 Foundation I Grouting/' Insulation 1,7£/,_ L ~id-i?·ox~ Underground I!IUmbing (/ Drywall , ;::;· -z:-.;--c:> ~, pra-J_ Rough Plumbing Electric Final (by State Inspect~(< Cf-6-vSJ/;72-(Priortofinal) O[L--# I r 1 Rough Mechanical Septic Final Gas Piping FINAL J-/:S-o9 r~7//8fl<'-" ~ 'l -!"l-""" '}??/-! Electric Rough (by State Inspector) {You Must Call For Final Inspection) 0~ f~~ t_' -·-:! : D· Notes (Prior to Framing) Framing /O·'f-o&-~ ,.-~~~ (to include Roof in place 8r Windows & Doors installed & firestoppfng in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970·384-5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD By t-JOFJmfl~. J~ PROTECT PERMIT FROM WEA ER DAMAGE (DO NOT LAMINATE) Parcel Detail Page I of3 Garfield County Assessor/Treasurer Parcel Detail Information Asses~o.rLireas\lLeLI'nmert)' .. S.earch I Asses.sor_Subset_Quei)' I Assessor_Sal~...S~aiT.h Clerk & Recorder Recej:ltion Search Basic Building_Characteristics I TaKinformllili>n Parcel Detail I Value Detail I Sales Detail I Residentia!LConu.nercil!UnmrovementDetail Land Detail I PhQ_tggraph;, I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 008 II R008606 II 239515312009 II 60.596 I Owner Name and Mailing Address !WITTENBERG, KEITH ANDREW & HANNA MARIE 142 HAYSTACK ROAD !GLENWOOD SPRINGS, CO 81601 Assessor's Parcel Description (Not to be used as a legal description) jSECT,TWN,RNG:15-7-89 SUB:OAK jMEADOWS RANCH 4TH. LOT:9 DESC: 2ND jAMENDED PHASE 1, F4B. PRE:R080257 jBK:0481 PG:0511 RECPT:744728 jBK:1837 PG:493 RECPT:705618 BK:1353 jPG:127 RECPT:602928 BK:1348 PG:263 jRECPT:601840 BK:0841 PG:0567 Location Physical 1129 OLD MIDLAND DR GLENWOOD SPRINGS! Address: I Subdivision: jjOAK MEADOWS RANCH 4TH. I I Land Acres: J 0.21 I Land Sq Ft: J 0 II II http:/ /www.garcoact.com/assessor/parcel.asp?Parce!Number=239515312009 5/112008 Parcel Detail Page 2 of3 llf==~Se;;;~~;;;io;;,n =~~~~~ =T:;;ow~;;;;sh~ip~=l[~l =="'R;;;:~n~9 ge~====l11 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: 73,04oll 21,1801 I Improvements: oil ol I Total: 73,04oll 21,1801 Sale Date: 113114/2008 Sale Price: 11172,000 Basic Building Characteristics Number of Residential lo I Buildings: Number ofCommllnd 0 Buildings: No Building Records Found Tax Information Tax Year Transaction Ty[!e Amount I 2007 Tax Payment: Whole ($1,213.72)1 2007 Tax Amount $1,213.721 2006 Tax Payment: Whole ($1,341.44)1 2006 Tax Amount $1 341 441 , 2005 Tax Payment: Second Half ($664.55)1 2005 Tax Payment: First Half I ($664.55)1 2005 Tax Amount II $1,329.101 2004 I Tax Payment: Second Half I ($688.11)1 2004 II Tax Payment: First Half ($688.11)1 2004 II Tax Amount $1,376.221 2003 II Tax Payment: Second Half ($606.99)1 2003 II Tax Payment: First Half I ($606.99)1 2003 II Tax Amount II $1,213.981 2002 II Tax Payment: Whole II ($155.52)1 2002 II Tax Amount II $155.521 http://www.garcoact.com/assessor/parcel.asp?Parce1Number=239515312009 5/1/2008