HomeMy WebLinkAbout8.0 ISDS Site PlanIndividual Sewage Disposal/Treatment System Type:
c Tank
Comers Name and Address:
Peter Langegger
361 C.R. 311, Silt, CO
Garfield County, Colorado
Project Number:
14115
House Size (sq. ft.):
N?A
N/A gallons/person/day
No
Garbage Disposal? (Y/N)
Number of Bedrooms in Alain House
t
0
Number of Offices, I ihraries, Studies, Similar -.sized Rooms in AMin House
0
Number of Bedrooms in Detached Caretaker unit
0
Number of Offices, Studies. Similar -sized Rooms in Caretaker Unit (.If the caretaker unit is
ATTACHED, treat as if part of main house.)
0
Total Bedrooms
and Potential
Additional flow in
closet, lavatory, and
Bedrooms:
gallons/person/day
shower:
persons ming additional
0
due to two (21
bathrooms.
mtmum of 2 bedroom
equivalents.
bathrooms, assume crater
0
0
0
AverageDaily Waste Flow :
900.0
gallons/day 10 Campsites x 50GPD + 1 Washy x 400GPD = 900GPD
State Review Required?:
No
I I
Average Percolation (tate {t) =
20.0
The Design Percolation rote is based
pemolalian rate achieved from the
compaction of Claes 6 Aggregate
mound leach field spout.
on the assumed
Design Flow (.Q) =
Design Flow, Q =1,350
`minutes/inch
Average Daily Waste Flow X
Igallonsiday
1.5
importation and
Base Course for the
Absorption Area -
A = (1 .4 ) � ( -../I)
? )
A
1690.47
sq. h. of absorption area required
1,691.00
sq.fl. (Rounded Areq
A (Bed) =
1183.33
sq. ft..
Bed Configuration with Chambers:
30
°b Reduction
INFILTRATORS
for
Garfield
County
Number of Infiltrator Units
(TRENCH)
120.75
Quick4
Rounded Number of Units:
121
1 Jrows of
11.00
units each
2.83 feet wide X
46.00
feet long
Unit Length:
4.00
Row Separation: 0.00
1,371.33
sq. h. of trenches
Unit Width:
2.83
Bed Width (it) = 31.17
Bed Length (ftJ =
44.00
Actual number of Infiltrators for 'square' field/trench =
121.00
units
,
Variable Setback Calculatienaor A6torplien Trench,
Seepage Bed, Sand Filter, Sub -surface Diagonal System,
or Dryn ell
Design Flow (from above), Q
=
Minimum setback from spring,
well. suction lines =
1,350
128
gallonsiday
feet
Minimum setback from lake,
water course. stream or
irrigation ditch
78
feel
minimum SetbaCK from dry
gulch=
53
feet
8/27/20141a 49 AM
IAGVWF114115101AITS Calculations 201401326.x1s
es2s —
/ GO`O
�
FP —
skGS—
/g
/ v
SO
— —
/
/
- - — - —— N
//-
•%
1/
/' \
)NEAR FLOOD WAY BOUNDARY
- - - -
r
i
i•--
i/ i • i/
•
es.
/—/ —
/— — /
/--
„
—��
1
1
1
7
10 CAMPSITES WITH TEPEES
• > /
EXISTING BRIDGE
f —
/
/�-- — j
_as — —� •. /
i%/
—
; a
./i
— _ J
•
•
100 YEAR FLOOD BOUNDARY
/
- - -
TING SEPTIC TANK
ROPOSED SEPTIC EFFLUENT PUMP STATION
/
\ \ PROPOSED MOUND TYPE LEACH FIELD
\ \ 7— APPROX. BASE OF FILL AROUND MOUND SYSTEM
j
/
/
/
I
I
O�
•
i
50
50
100
150
GRAPHIC SCALE IN FEET
1 INCH = 50 FEET
LEGEND:
PROPERTY LINES
EDGE OF EXISTING GRAVEL ROAD
DEMARCATION LINES OF 100 YEAR
FLOOD ELEVATIONS
100 YEAR FLOODWAY BOUNDARY
EXISTING SEPTIC LIDS (TYP)
EXISTING WATER WELL
EXISTING TEEPEES
Lip
2
PETER LANGEGGER
ISDS SITE PLAN
m
e
Y
m
❑
x
U
M
e
W
0
o_
O
w
S a
❑
V
m
z
O
w
z
a
❑
REFER TO NOTE "A" BELOW
e,
FINISHED GROUND SURFACE ELEV. = 5431.50
3 - 4" DIA. CAPPED
PVC MONITOR WELLS
EXTENDING TO BOTTOM OF
CLASS 6 GRAVEL WITH
PERFORATIONS ON LOWER 3.5'.
1-1/2" PVC DISTRIBUTION PIPE
FINISHED GROUND SURFACE ELEV. = 5431.50
3
=_5429.50
rri aratiattatirat
'37
3
100 YR._FLOOD LEVEL_ ELEV.,
100 YR. FLOOD LEVE ELEV= 5429.50
-1 I Iain 1 2.00' TOPSOIL COVER
essNE
CLASS 6 GRAVEL FILL
OR APPROVED EQUAL
1.00
EXTEND
GRAVEL
FILL (TYP.)
�1
2.00' TOPSOIL COVER .,, TLI Fj �I�18/1
, I II I K
–711=1 11=� I III— 11-�N0 SVRAAce
II II II I _
III I�If IHI q illg11�11i1111
III -1 I I I I I I_I I I III I
-a
EXISTING GROUND SURFACE (APPROX. ELEV. =5427)
EXCAVATE 1.00' BELOW
THE EXISTING GROUND SURFACE
=I I
.I
MEAN GROUND WATER LEVEL (APPROX. ELEV. _5425)
FINISHED GROUND SURFAE ELEV. = 5431.50
2.00
I
a
0
Z
r
x
N
C%1
PETER LANGEGGER
SUPPLY PIPELINE FROM PUMP CHAMBER
FRONT VIEW CROSS SECTION OF MOUND LEACH FIELD
SCALE :1 INCH = 2 FEET
11 - 1-1/2” PVC FEEDER PIPES HUNG INSIDE LEACH CHAMBER.
DRILL Y4 " HOLES @ 2 O'CLOCK AND 10 O'CLOCK EVERY 2 FEET
ALONG PIPE INSIDE CHAMBERS. DRILL ONE Yn" HOLE @ 6 O'CLOCK
AT THE END OF EACH LEACH CHAMBER TO ALLOW PIPES TO DRAIN
AFTER PUMPING. INSTALL SPLASH PLATE BENEATH EACH DRAIN HOLE.
INFILTRATOR LEACHING CHAMBERS OR EQUAL
LEACHING BED COMPOSED OF 6 UNITS LONG
BY 4 UNITS WIDE
3 CAPPED MONITOR WELLS
4" DIA. PVC PIPE.
TOPSOIL
FINISHED GRCUND SURFACE ELEV. = 5431.50
REFERFO NOTE "A"BELOW
100 YR. FLOOD LEVEL ELEV. = 5429.50
4" DIA. PERFORATED PVC PIPE
CLASS 6 GRAVEL FILL
OR APPROVED EQUAL
1.00
EXTEND
GRAVEL
FILL (TYP.)
2.00' TOPSOIL COVER =
I ==IINI=II I
0
17.111_7111,1:111;_11
SUR
11_111
1A1
111-111— 1-
1
11=411 =
11111_=111_=111=111=111n
1
— — — — —
3
1
EXISTING GROUND SURFACE (APPROX. ELEV. = 5427
L vl
EXCAVATE 1.00' BELOW
THE FASTING GROUND SURFACE
1-1/2" PVC PRESSURE PIPE
SUPPLY ,LINE FROM PUMP CHAMBER
MINIMUM SLOPE = I%
2.00
JMEAN GROUND WATER LEVEL (APPROX. ELEV. = 5425)
SIDE VIEW CROSS SECTION OF MOUND LEACH FIELD
SCALE :1 INCH =2 FEET
NOTE A FILL MATERIAL AROUND ALL SEPTIC SYSTEM COMPONENTS SHALL BE PROTECTED FROM EROSION DUE TO
INCREASED WATER LEVELS EXPECTED DURING A 100 -YEAR FLOOD BY ONE OF THE FOLLOWING METHODS:
1. INSTALLATION OF AN EROSION CONTFOL FABRIC SUCH AS A TURF REINFORCEMENT MAT WHICH IS RATED TO WITHSTAND
VELOCITIES OF UP TO 5 FEET PER SECOVD. FOLLOWED BY REVEGETATION OF ALL FILL MATERIAL SURFACES WITH A
SUITABLE GRASS MIX DESIGNED TO ACHIEVE A MINIMUM GRASS COVERAGE OF 90% OF THE SURFACE AREA.
2. PLACE A MINIMUM 12_ INCH DEPTH OF NELL GRADED COURSE GRAVEL OR COBBLE MATERIAL (3_INCH MINUS) MATERIAL
OVER ALL FILL MATERIAL SURFACES. FOLLOWED BY REVEGETATION OF ALL FILL MATERIAL SURFACES WITH A SUITABLE
GRASS MIX DESIGNED TO ACHIEVE A MINIMUM GRASS COVERAGE OF 90% OF THE SURFACE AREA.
♦n
o a
�_~
W
H CI
CI
H W
V W
Nam _
W V
H W
Y
m
Z
3
0
t9
r
m
0
z
V
U
d
r
T,
s
. r
z
Z
3 V
O 0
0
m
Y
S
>9
�Z
,
,
,
I
I
I
I
1
i
/
/
4 -INCH SDR35 PVC SEWER PIPE FROM
RESTROOM/SHOWER FACILITY
MIN. GRADE= 2%
EXISTING SEPTIC TANK BY OTHERS
(SEE DETAIL FOR ELEVATION OF RISERS BELOW)
PROPOSED SEPTIC EFFLUENT PUMP STATION
(SEE DETAIL BELOW)
7 N
APPROXIMATE EDGE OF FILL MATERIAL \
�IIV�IIIL �IUL.IIICJIIL �IIu�IUi
LEACH FIELD DISTRIBUTION
MANIFOLD TO BE SET WITHN
+/-0.01 FEET OF 0.00% GRADE.
1-1/2 INCH SCHEDULE 40 PVC
REFER TO NOTE 'A" BELOW
5.671
425'
4.25'
5.67
PROPOSED MOUND TYPE LEACH FIELD
121 QUICK -4 INFILTRATOR UNITS
11 UNITS WIDE BY 11 UNRS LONG
44.W
111.1
__ MIS
=� o����_11111111
__=
remalalliarari
_____=-_
lati__ ___
Ireraminaltdriaalarmalla
_____==___
11111111111111111111111111111111111111111111111111111111111111111111111111111111111111
111111Inlalreallirliallallalla al
I ri I lalla le al I al Ill ral I 11. re I l
MIN
___�_=
Insulate Inside of ALL Lids with
Blue Board Foam (typ.)
SVOpt.,y:1
2.00' 12 -AWG "UF" INSULATED
TRACE WIRE
MEAN GROUND WATER LEVEL (APPROX. ILEV. = 5425)
4 -IN. SCH. 40 P.V.C.
GRAVITY SEWER FROM BUILDING
IINIMUM SLOPE = 2.00
NOTE A: FILL MATERIAL AROUND ALL SEPTIC SYSTEM COMPONENTS SHALL BE PROTECTED FROM EROSION DIE TO
INCREASED WATER LEVELS EXPECTED DURING A 100 -YEAR FLOOD BY ONE OF THE FOLLOWING METHODS:
1. INSTALLATION OF AN EROSION CONTROL FABRIC SUCH AS A TURF REINFORCEMENT MAT WHICH IS RATED U WITHSTAND
VELOCITIES OF UP TO 5 FEET PER SECOND. FOLLOWED BY REVEGETATION OF ALL FILL MATERIAL SURFACES VITH A
SUITABLE GRASS MIX DESIGNED TO ACHIEVE A MINIMUM GRASS COVERAGE OF 90% OF THE SURFACE AREA.
2. PLACE A MINIMUM 12_ INCH DEPTH OF WELL GRADED COURSE GRAVEL OR COBBLE MATERIAL (3LINCH MINIS) MATERIAL
OVER ALL FILL MATERIAL SURFACES. FOLLOWED BY REVEGETATION OF ALL FILL MATERIAL SURFACES WITH /SUITABLE
GRASS MIX DESIGNED TO ACHIEVE A MINIMUM GRASS COVERAGE OF 90% OF THE SURFACE AREA.
3.5' (MIN.)
24" DIA.
WATER -PROOF
RISER
,'
(MAX.)
LEVEL CONTROL AND ALARM SWITCh RELAY
IN WEATHER PROOF ENCLOSURE MOLNTED
ON POLE ABOVE 100 YEAR FLOOD.
Grade Finished Ground away from ALL Yds;
Revegetate all disturbed surfaces with Pitkin
County Approved Seed Mu. Today soil prior to
seed application, irrigate per recommendations.
FINISHED GROUND SURFACE ELEV. = 5430.50 (MIN.)
100 YR. FLOOD LEVEL ELEV. = 5429.50
EXISTING GROUND SURFACE (APPROX. ELEV. = 5427)
TOP OF TANK ELEV = 5425.70 (APPROX)
24" DIA.
WATER -PROOF
RISER
,"
(MAX.)
T
3"
(MIN.)
17"
— (FROM INLET
ELEVATION)
•
14"
FROM
OUTLET
ELEVATION
2
CROSS-SECTION VIEW:
EXISTING SEPTIC TANK
2
4
6
GRAPHIC SCALE IN FEET
1 INCH = 2 FEET
3.5' (MIN.)
4 -IN SCH. 40
P.V.C.3RAVITY
PIPE '0 PUMP
CFAMBER,
MINIMUM
SLOE = 2.00
PLACE A MINIMUM F 6.75 CUBIC
YARDS OF CONCRFE BACKFILL
AROUND BASE OFIANHOLE TO
COUNTER BUOYANT FCCES DURING
HIGH WATER
025'
3.20'
31.1T
MONITORING WELL (TYPICAL)
■
Splice Box
,
/
/
/
/
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
PUMP OFF LEVEL
CROSS-SECTION VIEW:
PROPOSED PUMP CHAMBER
48' Dla. WATER -TIGHT PRECAST
CONCRETE OR HDPE MANHOLE
FOR PUMP STATION WITH
INSULATED LID AND FRAME
5.50' 1
(M N.)
2.00
IMEAN GROUND WATER LEVEL (APPROX. ELEV. = 5425)
1-1/2in. Dia. Sch. 40 PVC TO
LEACH FIELD MANIFOLD
ORENCO SYSTEMS:
Cold Weather Pump Discharge Assembly (OR APPROVED EQUAL):
HV CW 200 KR
Float Switch Assembly.
MF3A-Y,B,R, W-27, FS, 20
Effluent Pumps: TWO (2) GRUNDFOS PEF 5011
Control Panel: ORENCO'DAM CS(a)' - alternating pump controls.
15
GRAPHIC SCALE IN FEET
1 INCH = 5 FEET
NOTE: ALL FITTINGS AND CONNECTIONS WHICH ARE LOCATED BELOW THE
100 -YEAR FLOOD ELEVATION SHALL BE WATER -TIGHT CONNECTIONS.
095
O
z
w
2
PETER LANGEGGER
(Pk'
Z°
_w
W
w�
in
WN
QZ
4 J
Ua
Or
(n 2
4W
c
W J
F",(0
ao
Ou
t,
T
m
Z
e
M
Z
5
I
O
2
V
.5 m
Q
O