Loading...
HomeMy WebLinkAboutApplication - PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Gl enwood Springs, Co. 81601 Office :970-945-8212 Fax: 970-384-3470 Inspection Line : 970-384-5003 Building Permit No. J ._,_VUl__,__{q ____ _ Parcel No: 2179 -163 -00-6 53 Locality: Dry Hollow Ranch, Lot 4 Job Address: 1580 Chair Bar Rd . Silt Use of Building: Steel building for home occupation Owner : Whilldin, Donald & Linda Contractor: Owner Fees: Plan Check : $ 600.4 4 Sept ic: $ 173.00 Bldg Permit: $ 923.7 5 Other Fees: Total Fees: $ 1,697 .19 Clerk: ~ Date : Ul\ll-\CB I ' I 2 Parcel No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite401, G lenwood Springs, Co 8 1 601 · Phone: 970-945-8212 I Fax: 970-384-3470 I Ins pec tion Line: 970-384-5003 www .garfie ld-count v .com d-r '7 cr---1 Lt> so o-t.a 5 _3 Job ~ddrt?: (Streeh. N~me,~; 1 S' 0 c;rd' ?I ' ;2cl (J/11: OD x/bc;-d- 3 L otNo : L\ Block No: Suh~~e m \.\~\\.t>UJ ~U~CV\ lj'g M. ~ ~.Pa 4 Owne y -Dc> 1 ~j\ w h ; /U," Mailing AfY;_;s (5o i. / /t,. ~ Ph· ~7h6 os,S'g '1!14f-r,_ :f. j(qi.j f?-'fo-o.S~ ) 5 Contractor: ~cLr:. M a iling Address R~ Ph : A lt Ph: r ~rr/ J14 /'::; 6 Architect I Enf!in P.P.r· Mailing Address Ph: Alt Ph: I ,f 1/: 7 Sq-. -Ft. of Building: 3 t I Sq. Ft. or Acres of Lot: I{ !1 Heig ht: No. of Floors : ovo 0 G N' .J I 8 Use of Building: tlnoccuj'J It I ;./or»~ /Jt/5; 11 1' $5 9 D escribe Work:t B/ee / /JCf: fJ,'I'Jn it;\ ~ ~~· I ~ ..... 7 10 C l ass of W ork : u . I }if New o Alte ratiOn o Addit ion ]] Garage: Septic: o Attached 0 Detached ;'ISDS oCommunity 12 Driveway Permit: AJ/A Owners valuation of W o rk: $ 7 5; 0 C'X) Cl!L--- ! NOTICE Authority. This application for a Building Permit must be signed by the Owner of the propeny. described above. or an authorized agent. If the s ignature below is not that of the Ow ner. a separate le tter of authority. signed by the Owner, must be provided with this A pplication. Legal Access . A Building Permit ca nnot be iss ued without proof of legal and adeq uat e access to the propen y for purposes of in spections by th e Buildin g Depanment. Othe r Permits. Multiple separate permits ma y be required: (I ) State El ectri ca l Permit. (2) County I SDS Permit. (3) another permit required for use on the propeny ide ntified above, e.g. State or Co unty Hi g hway/ Road Access or a State Wastewater Di scharge Permit. Void Permit. A Building Permit becomes null and vo id if the work authorized is not comme nced within 180 days of the date of iss uan ce and if w ork is sus pende d or abandoned fo r a period of 180 days aft e r commencement . CERTIFI CATION I hereby certify that I ha ve read thi s Ap pl ication and that the information cont ained above is true and correct. I understand that the Building Depanment accepts the Applicatio n. along with the plans and s pecifications and othe r data submiucd by me or on my behalf (s ubmittal s). based upon m y certifi cation as to acc uracy. Assuming completeness of th e submittals and approval of this Appli cation. a Building Permit will be iss ued granting permi ssion to me . a s Owner , to construc t the structure (s) an d fa cilities detai led o n th e submittals re vi ewed by the Buildin g De panment. In consideration of the iss ua nce of the Buil din g Permit. I agree that I and my age nts will co mply with provisions of an y fed eral. state or loca l law regulating the work and the Garfield County Building Code. ISDS regulations and appl icable land use re gul atio ns (County Regulation(s)). I acknowledge th at the Building Permit may be s uspe nded or revoked. upo n notice fro m the County. if the location. constructi on or use of th e structure(s) and facilit y(ies). descri bed above, are no t in compli ance with Count y Regulation (s) or any other appli cable law. I hereby grant permission to the Building De panment to enter the property. described a bove. to inspect the work. I further acknowle dge that the issuance of the Building Permit doe s not prevenr the Bui ldin g Offi c ial from: (I) re quiring the correc tion of errors in the submittals , if any, di scovered after iss uan ce; or (2 ) stoppi ng construction or use of the structure(s) or facility (ies) if suc h is in violati on of County Regulation(s) or a ny other applicable law. Re view of this Appli cation. in cluding s ubmittals. and inspections of th e work by the Buildi ng Depanment do not constitute an acce ptance of res ponsi bilit y or liability by the County of errors. omissions or disc repanc ies. As tl1 e Owner, I acknow ledge th at res ponsibility for compliance with federal. state and loca l laws and C ounty Regulations rest with me and my authori zed agents. including without limitatio n my ~ct desig ne r. engineer and / or builde r. > HE'EB:t?:=~~GET:;?J):l!}JZTA'DTHENOT>~ ~;;;~""" . OWNERS SIGNATUJiE DATE STAFF USE O NLY Special Conditions: M ise Fees: DATE The following items are required by Garfield County for a final Inspection: I) A final Electrical Inspection from the Co l orado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) · A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All.bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks , grading may be made .upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bapplicationseptember2007 VALUATIO N FEE DETERMINATION Applicant Address Date Whilldin Subdivision ~~~----------------------1580 Chair Mt Rd. Lot/Block ~~~----------------------6-Jun-08 Contractor ~~~---------------------- Finished (L ivab le Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Covered Open Valuation Type of Construction: Occupancy: Util ity Valuation Total Val u ation sf sf sf sf X $74.68 0 sf sf X $4 1.00 sf X $33 .68 sf X $18 .00 sf X $9.00 sf X $24.00 sf X $12.00 Commer cia l 3000 sf X $29.99 sf X sf X sf X sf X sf X DL Hollow Ranch ·~ 0.00 0.00 0.00 0.00 0.00 89,970.00 89,970.00 VALUATION FEE DETERMINATION Applicant Address Date Whilldin Subdivision """1"=5 8:::o"'c='h:.:.a7ir-:-M-:-t-::R:-d:-. -------Lot/Block ..::6~-J,un:!:-,08::,_ __________ Contractor Finished (Livable Area): Main Upper Lower Other Total Square Feet Valuation Basement: Unfinished Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Utility Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 Commercial 3000 sf X 7.81 sf X sf X sf X sf X sf X $29.99 IJ.oo /0/.p DL Hollow Ranch 7 ' 0.00 0.00 0.00 0.00 0.00 )!9,976.6()' 89,976.66 /o4-D8"L PLAN REVIEW CHECKLIST Applicant kJt+JI/zYAI Date b,CO--C8 Building ~neered Foundation ~c Permit and Setbacks ~e/Topography 30% ,dilAttach Residential Plan Review List ~mum Application Questionnaire ~ivision Plat Notes M Fire Department Review Clt{J ~al uation Deterrnination/F ees __ Red Line Plans/Stamps/S ticker ~h Conditions ~ication Signed 4 ewer To Sign Application ~/Schedule No. ~0# Snowload Letter-Manf. Hms . ~ Soils Report GENERAL NOTES : Planning/Zoning 0roperty Line Setbacks .f:l:/l_3oft Stream Setbacks 4 Flood Plain Auilding Height -~ng Sign-off ~Road Impact Fees lj__HOAIDRC Approval ~de/Topography 40% ~ing Issues Ctt p i!.I1_ Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. I Plans must include a floor plan, a concrete footing and foundation plan, elevations all si des with decks, balcony steps, hand rails and guard rails, wi ndows and doors, inclu ding the finish grade and original grade line . A section showin g in detail , from the bottom of the foot ing to the top of the roof, including re -bar, anchor b olts, pres sure tre ated pl ates, fl oor j o ists, wa ll stud s and spaci n g, insulation, sheeting, hou se-rap, (w hi c h is required), siding or a ny approved bui ldi n g m at erial. Eng in eered foundation s ma y be re quired . Ch eck with the Buil ding Departm ent. A window sc hedule . A door schedul e. A fl oor framing plan, a roofin g f ramin g plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation , a 90 M.P.H. windspeed, wi nd exposure B or C, and a 36 in ch frost depth. All s h eets need t o be identified by number and indexed. All of the above requirements must be met or yo ur plans wi ll be retu rn ed. A ll plans submit ted mu st be incompliance wi th the 2003 IBC , IPC, IMC and IFGC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: I. Is a site pl a n included that id e ntifi es th e l oca tion of the p r oposed s tru ct ure, additi o n s or oth er buildings, setb ack easements, and utility easements sh owin g distances to th e property lines from e ach corne r of the proposed structure prepared by a licensed surveyor and h as the surveyors s i g nature and professiona l stamp on the draw in g? Slopes of 30% or more on properties must be show o n si te plan. (NOTE: Section 106.2) Any site p l an for the placement of any porti on of a s tructure wi thin 50 ft. of a property line and not within a previously surveyed bui ldin g envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the s urveyors signature and professional stamp o n the draw ing. A n y structure to be b uilt withi n a building envelope of a lot shown on a recorded s ubdivi sio n plat, shall in clude a copy of the building envelope as it is shown on the final pl at with the proposed s tructure located within the envelope. Yes )( 2. D oes the site plan when appli cable inc lude th e l ocation of the I.S .D.S. (Ind ividua l Sewage Disposal System) and di stances to th e property lines, wells (o n s ubject property and adjacent properties), streams or water courses? This information mu st be cert ified by a li censed s urveyor w i th their s ignature and professi o n al stamp on t he design. Yes X , _ No_.,--No t necessary for this project __ _ 3. Does the site plan indicate t he l ocatio n and direct ion of the State, County or private road accessing the property? Yes-!-- 2 4. 5. 6. 7. 8. 9. 10. II. 12. 13. 14. Is the I.S.D .S. (Individual Sewage Disposal System) designed , stamped and signed by a Colorado Registered Engineer? Yes No ~ Not necessary for this project __ _ Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit is suance only" or similar language? Yes )C No__ Not necessary for this project __ _ Do the plans include a foundation plan indicating the s ize, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes,l No__ Not necessary for thi s project __ If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes ___i_ No__ Not necessary for this project __ Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes__ No__ Not necessary for project~ Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes~ No__ Not necessary for this project __ Do the plans include design loads as required under the IBC or IRC for roof snow ~ds, (a minimum of 40 pounds per square foot in Garfield County)? yes No__ Not necessary for this project __ Do the plans include de sign loads as required for floor loads under the IBC or IRC ? Yes~ No__ Not necessary for this project __ Does the plan include a building section drawing indicating foundation, wall, floor, and roof c;;struction? Yes No__ Not necessary for this project __ I s the b nd speed and exposure design included in the plan? Yes No__ Not necessary for this project __ Does th e building section drawing include size and spacing of floor joists, wall studs, ceilinl joists, roof rafters or jois ts or trusses? Yes No__ Not necessary for this project __ 3 15. 16. n. }8. 19. 20. 21. 22 . 23. 24. Does the building section drawing or other detail include the method of positive conney:on of all columns and beams? Yes No__ Not necessary for this project __ Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the rnidpoint .between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Yes_&_ No__ Not necessary for this project __ Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Ye s__ No-+--Not necessary for this project__.,.(L Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IP,..... or IRC? . -.,(_ Yes__ No_~1 _ _ Not necessary for this project-+-=- Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IBC or IRC? Yes__ No__ Not necessary for this project~ Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms ? YesL No__ Not necessary for this project_• __ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors ; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? "- Yes__ No__ Not necessary for this project_/_' Do the pl ans include a complete design for all mechanical systems pl anned for installation in this building? Yes__ No __ _ Not necessary for this proj~ct __ )(_· _ Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Chapter 3) Yes+ No__ Not necessary for this project __ _ Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes__ No__ Not necessary for this project__ls..._ 4 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan ? Yes__ No__ Not necessary for this proj ect~ 26. Do the plans indicate the location and dime nsion of re s troom facilities and if more than four z loyees and both sexes are employed, facilities for both sexes? Ye s No_· _ Not necessary for this project ___ _ 27. Do the plans indicate that restrooms and access to the building are handicapped accessjble? Yes~_ No__K_ Not neces sary fo r thi s project-,--,__ .:f:' 28. Have two (2) complete set s of construction drawings been submitted with the application? Ye s-f-N o __ 29. Have you designed or had thi s plan designed while considering building and other construction code requirements? · Yes __f;._ No__ Not nece ssary for thi s project __ 30. Does the plan accurately indicate what you intend to construct and what will receive a final i{'(ection by the Garfield County Building Department? Ye s No __ 31. Do your plans comply with a ll zoning rule s and regulations in the County rel ated to your zone dis trict ? For corner l o ts see s uppl e mental section 5.05.03 in the Garfield County Zonin,Resolution for setback s. Yes No. __ _ 32. Do you understand that appro val for design and/or construc tion changes are required prior to th e implementation of the se c hanges? Yes_& No __ 33 . Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Imp act" fees required, at the time you pick up your building permit? Y es __:j::.._ No __ 34 . Are you aware that you are required to call for all inspections required under th e IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and ocq1pancy of the building? Yes£ No __ 5 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party respons ible for the project must comply with the Uniform Codes? Yes~ No __ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday .. Inspections are to be called in to 384-5003. 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes_E_ .No ___ _ 38. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge De partment stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes K No ___ _ 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection . Ye s X No. ___ _ 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to submittal of the building permit application? Your attention in thi s is appreciated. Yes ·'-No. ___ _ 41. Do you know that the local fire district may require you to s ubmit plans for their review of fire safety issues? Yes ";(. No (Please check with the building department about this requirement) 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes 'f. 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of th e IBC to pre pare the plans and specifications for the project. Yes ~., __ No Not Necessary for this project-·*~--- 6 I hereby acknowledge that I have read, understand, and answered these questions to /)the b~st of my ability. ~tJ t/2~, ·5it0/os Signature t> Date' Phone: ((' 7 6 ~ 0 ~ 5 '?' (days); _CZ_L_..OI/_.{i.J-LZ:__,O"--"'S---=-'J--( evenings) Project Name:_....,W'-=-'-~_,_._,_/=/j."--.,_r~'---~'--='-'-"-'-'1'----------- Project Address: r~BO Cha,. /' $a r M Note: If you answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. *If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. Bpcomm April 2006 7 June 11, 2008 Donald & Linda Whilldin 1580 Chair Bar Rd. Silt, CO 81652 Garfield County Building & Planning Glenwood Springs, CO 81601 RE: Permit# { 0 'i 77 Dear B & P, Attached are two copies (one original and one copy) of the revision to the foundation plan for our building at 1580 Chair Bar Rd. They are being submitted in order to amend the Building Permit to conform to Garfield County code. Please let me know if there is any additional information needed. I can be reached at (970) 948-7052. Thank you, tLJ/tJ~r Donald J. Whilldin M ay 29,2008 Project: D on Whill d in RE: A lt ernate F l Peri me te r Foot er D ear Mr. Whilld in, P.O Ba< 396 O ;aH,:nr!lo, ColllornK> 9 3 610 Offi ce (559) 665-9200 f (ll( (559) 665 0879 i:-11 rrcc (000) 57 4 -9484 ME1A.l8U UJINGF0 l.NDN!01'5 con> W e have re vi e w ed yo ur request to use an alt e m ate foo tin g design f o r t he perim e ter foo ter as r efere nce d as F l o n Shee t SA-l. P lease le t th is Je tter ser ve as offic ial no ti ce that th e detai l be low m ay be used in li eu of F l. P lease refere nce th e deta il below as F lA in all fu ture correspond en ce. --~~-,--,f--'--, I 6" Mi n. n fL----____J I 36 " Min . 42"Min.l Best Regards, :I 'I i.l ---#4 Re bar@ 32" o.c. Altern ate Sides .... 11 (3) #4 Horiz. Rebar (2 ) #4 Horiz . Rebar In Footer L 'l ++-G o m son anager WE DO FOUN DATIONS f( i g trr~;! JUN-06-2008(FR!) 14:15 Salsa Steel Corp. May 29,2008 Project: Don Whiltdin RE: Altcrnatc Fl Pcrimctl!l' Footer Dear Mr. Whilldin, (FAX)559 665 0879 p 002/002 J!Q. 1\.."JJ 3~ O"lowct•likJ, Goll!t.uilla93011J OMI.;o!6ti"..).O.O.Ct·9-:IX) FIW.tfi59J M:J.Oll':? "klli·FrrHI' ttiJQJ a7ol•94lW Mr."AL[lUlDifi.GrotNDAIIOt£.c~tll We have reviewed your request to use an alternate footing design for the perimeter footer as referenced :u; Fl on Sheet SA-l. Please let this lcttl!l' serve :u; official notice that th~: detail below may be used in lieu of Fl. Please reference the dctnil below as FlA in all future correspondence. 1/2' F'MJ Slab See Plan ·· #4 Rebar@ 32" o.c. Allernale Sides (3) #4 Horiz. Flebar (2) #4 Horiz. Rebar In Foo1111' ~ I e," .. L ~··;~ we. oc F'cuNoATicNS Right! Donald & Linda Whilldin 1580 Chair Bar Rd. Silt, CO 18652 Phone(970)948-7052 Oct. 6, 2008 County of Garfield Building Department Sir, RE: Permit #10979 amendment request Attached are drawings for a cold storage addition to our 60 X 50 Steel building. These drawings incorporate a retaining wall to protect the building from drainage as well as from the possibility of the Multi-Trina Ditch blowing out adjacent to the building. A footer has been poured and a stop work order on the balance of the concrete wall is in effect at this time. Attached are photos of already completed work. We would appreciate being able to complete the concrete portion of this addition before cold weather has a negative effect on the concrete work. The phone number for the engineer (Ken Brotsky) is (970) 216-8861 and my number is above. Donald J. Whilldin APR-11-2008 16'15 GOLUBA & GOLUBA PC 970 945 9143 P.09/11 • : j/ GARFIELD COUNTY · .,, '·, ··.,,Building & Planning Department Review Agency Foan Date Sent: March 5, 2008 Comments Due: March 31, 2008 Name of application: Whilldin. Donald J. & Linda L. Sent to: Garfield County requests your comment in review of this project. Please notifY the Planning Department in the event you are unable to respond by the deadline. This form may be used for:;YPUf,response, or you may attach your own additional sheets as necessary. Written comments may be mailed, e-mailed, or faxed to: Garfield County Building & Planning Staffs contact: David Pesnichak 109 gth Street, Suite 301 Glenwood Springs, CO 81601 Fax: 970-3 84-34 70 Phone: 970-945-8212 General Comments: Garfield Countv Road & Bridge Dl!lPartment has po objections to this'application with the following comments. · The driveway access to Chair Bar R;anch js already permitted and meets all requirement for this ap,plication including a stop siw at the entrance to Cr. 331; This will exempt them from the driveway access permit reg)lirement for this application. All vehicles hauling equipment and materials for this building will be required to abide by Garfield Counties oversize/overweight system ifreqyired. Ali Cr. 331 has been upgraded this application will not haye an impact on the traffic volume on Cr, 331 for delivery and shiPPing of materials. Name of review agency: Garfield County Road and Bridge Dept By: Jake B. Mall Date March I o. 2008 Revised 3/30/00 May 16, 2008 Donald & Linda Whilldin P.O. Box 1165 Silt, CO 81652 (970) 948-7052 Garfield County Building & Planning Dept. 1088'h St., Suite 401 Glenwood Springs, CO 81601 Dear GCP&B Dept, Attached is our application for the new construction of a steel frame building on our property located at 1580 Chair Bar Rd., Silt, CO., along with a Septic Permit Application. There are two sets of information in addition to the attached applications and questionnaire. They are numbered and labeled as follows: 1. Site plan showing building location, septic location and cistern location. 2. Letter from Bridge & Road regarding driveway 3. Copy of Conditional Use Permit relative to the building 4. Foundation engineering 5. Foundation plan drawing 6. Building plans We appreciate your consideration. Please notify us if there is anything additional that is needed. SL;&Uit. Donald J. Whilldin WEST SLOPE TESTING & INSPECTION 3177 Glendam Dr Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 9-26-08 Page 1 of 1 Andrew Schwaller Garfield County Building Official 108 8th St., Suite 401 RECEIVED Glenwood Springs, CO 81601 SEP 2 9 20 08 GARF IELD COUNTY BUILDING & PLANN ING Please find enclosed copy of special inspection reports for Metal shop Building 1580 Chair Bar Rd., final report for Club Lodge Duplexes, and reports owed to date for Glenwood Commercial Center Building #4. Thank you; Doug Young West Slope Testing & Inspection 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Date: 9-22-08 Inspection Report Project: Metal Shop Building Address: 1580 Chair Bar Rd. Silt, CO Building Permit No.: 10979 General Contractor: Don Whilldin Contractor that Performed Work: All American Steel Inspection of shop fabrication or field work at job site: Field Report#l Page 1 ofl Report: Visually inspected the high strength bolting at the main frame, portal frame column, and end wall frame rafter & column connections. Also randomly tested some of the bolts for proper tightness. The high strength bolting inspected as outlined above appeared to be in conformance with the drawings for bolt size & grade, and the A325 high strength bolts appeared to be sufficiently tightened. It also appeared that the flange & cable bracing was installed. To the best of my knowledge this completes the special inspections of the high strength bolting and steel frame details as outlined above. Inspector/Technician: Douglas E Young COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at C£80 c//A(I( BA/( gp, Permit No. /6' f 7 9 ' I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 7-? 20 &s- ~ _..?: // ! ~..~. Building Inspector ----7~""'"""""='---"'-"'b<=&.<;~..e;..~"'-"""'"""'=-""''----- Phone (970) 945-8212 / COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at /SSO ~ ~ b. Permit No. /{YJ/9 I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date {p ~/ (, 20· 0~ Building Inspector {J/iJtj }lfj__ Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE. 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Permit No. -~,LA-'~"-·-"9'---'7'--9L_ __________ _ I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date _ _.:A_:C/::_7 __ <f!__--::::o=;;-- ,..,--"7 .. , Building Inspector '--~-<-/':77·~ Phone (970) 945-8212 / .....,.. COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ;_s-g 0 Permit No. / ?J 9' Z 9 ~ ' I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date ?~ /8 20 0 l:? . Building Inspector 5 ~~ ~ ._ Phone (970) 945-8212 No. ___________ 1~0~9~7~9 __ __ Assessor's Parcel No. 2179-163-00-653 Date 6/11/2008 BUILDING PERMIT CARD Job Address 1580 Chair Bar Rd. Silt Owner Whilldinz Donald & Linda Address PO Box 1165 Phone # 970-948-7052 Contractor Owner Address same Phone# 970-876-0558 Setbacks: ~ RH LH Zoning J)[i()(Z ftitJ ~~ t-~Pt~t I INSPECTIONS '-- BUILDING PERMIT Date Issued LPI\IIOS GARFIELD COUNTY, COLORADO INSPECTION WILl NOT BE r~I[AOE UNLESS THIS CARD IS POSTED ON THE JOB PermitNo. \DctJt) AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that ifthe above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. useSfeel bUild1~C~QO Address or Legal Description \SiQ aov::;&,; RL ~ \t ownerWh\Jid\Q 1'{)ro. ldi, \,jnOQ contractor....,.Dw'tle~ ..... r-----~ Building Permit Type !?f<;\ denticU This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway &,-/~-of:> ~ J~--" Foundation I Grouting ~ · 1'1.-o :? :7-([.k'__ Insulation !#-:22~DfJ /JrtL ~-'J~ 1·17"~ j(jm ok__ Underground Plumbing 7--"?-0 8' y.cu. Drywall II- Rough Plumbing '{-/3-t!J'f5 5{Ld Electric Final (by State Inspector) / j-2/l.J:t-+ (Prior to Fin a() Rough Mechanical Septic Final 11-17-<>:rr~ Gas Piping FINAL I--z_ I -0 7 f'.~ "· /7 Electric Rough(~ State Infector) {t.;) l..iNI)I3P. 71-J>. C N~h11T} ~1.. 7-C-Or tJ. (You Must Call For Final Inspection) .SEN:,_. i i'''f(; RjJ o t(}fjfa .•. ·-· c _ y.,y -Notes~-££AN 70 Fv«'IVIJ/11 /tJ,V-/<?·/4-,<>~ (Pnor to Framing) -/. ~ ' I Framing /0-~2-otf A/?rL.-1~ Ji;.y&. fW'- (to Include Roof in place &Windows & Doors Installed & Firestopping in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970·384·5003 Office 970-945·8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ~:::ovED\Q\\\\('f) BvF. \o.rmon/~ PROTECT PERMIT fifoM WEATHErfDAMAGE (DO NOT LAMINATE) Parcel Detail Page I of 4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property Search I AiiS_~iiliQJ:_S_ub:>e_LQ\1~1)' I Asse.<;~orS_alesS_~arch Clerk & Recorder Reception Search Parc~ID~11lil I Y iiJl!e D_e1ail I S_ale.<> Detail I Residential/Commercial Improvement Detail Land Detail I Photographs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 023 II R005790 II 217916300653 II 45.551 I Owner Name and Mailing Address IWHILLDIN, DONALD J & LINDA L IPO BOX 1165 lsrLr, co 81652 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:l6-6-92 DESC: A TR IN ITHE NESW CONI 40.267 AC AKA LOT 4 IDRY HOLLOW RANCH. EXCEPT A TR OF ILAND CONI 6.882 AC +/-AS DESC IN IIBNDY LINE AFF BK 1624/995 AND QCD IBK 1625/1. ALSO A TR OF LAND CONI 16.788+/-AS DESC IN BNDY LINE AFF IBK 1624/995 AND QCD BK 1624/999 IPRE:R230958 BK:443 PG:291 BK:l625 IPG:2 RECPT:660329 BK:l625 PG:l IRECPT:660328 BK:1624 PG:999 IRECPT:660327 BK:1624 PG:995 IRECPT:660326 BK:l356 PG:715 IRECPT:603815 BK:1231 PG:38 IRECPT:575901 BK:l175 PG:265 http:/ /www.garcoact.com/assessor/parcel.asp ?Parce!N umber=21 79163 0065 3 I I I I I I 5/16/2008 Parcel Detail Page 2 of 4 IRECPT:559946 BK:0889 PG:0839 IBK:0591 PG:0337 Location I Physical Address: 111580 CHAIR BAR RD SILT I Subdivision: I Land Acres: 1140.173 I Land Sq Ft: llo Section II TownshiE II Range I 16 II 6 II 92 I 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II I4o,oooll 11,1401 I Improvements: II 342,o9oll 27,2301 I Total: II 482,o9oll 38,3701 Sale Date: 115121/2002 Sale Price: 11125,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd lo Buildings: I Residential Building Occurrence 1 Characteristics I TOTAL HEATED AREA: 112,536 II IISINGLE FAM.RES-ABSTRACT CODE: )MPROVEMTS ARCHITECTURAL STYLE: III-STORY EXTERIOR WALL: IIFR STUCCO ROOF COVER: IIRUBBER I ROOF STRUCTURE: llsHED I INTERIOR WALL: IIDRYWALL I FLOOR: IIFNSHD CONC http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=217916300653 5/16/2008 Parcel Detail I FLOOR: IIHARD TILE I I HEATING FUEL: IlGAS I HEATING TYPE: IIHT WTR RAD I STORIES: STORlES 1.0 I BATHS: 2.5 ROOMS: 6 UNITS: I BEDROOMS: 13 YEAR BUILT: 112002 I Tax Information I Tax Year Transaction T~(!e II Amount I 2007 Tax Payment: First Half II ($873.90)1 2007 Tax Amount II $1,747.801 2006 Tax Payment: Second Half I ($743.62)1 2006 Tax Payment: First Half ($743.62)1 2006 I Tax Amount $1,487.241 I 2005 Tax Payment: Second Half ($744.13)1 I 2005 Tax Payment: First Half ($744.13)1 I 2005 Tax Amount I $1,488.261 I 2004 Tax Payment: Second Half II ($741.01)1 I 2004 I Tax Payment: First Half II ($741.01)1 2004 Tax Amount II $1,482.021 2003 Tax Payment: Whole ($1,080.02)1 2003 Tax Amount $1,080.021 2002 II Tax Payment: Whole ($49.08)1 2002 II Tax Amount $49.081 2001 I Tax Payment: Whole ($48.84)1 2001 Tax Amount $48.841 2000 Tax Payment: Whole ($48.54)1 2000 Tax Amount I $48.541 ThpofPag(O! As.sess_QLDatabase Search_QpJion~ I Treasurer Database Search Options Clerk & Recorder Database Search Options http://www.garcoact.com/assessor/parcel.asp?Parce!Number=217916300653 Page 3 of4 5/16/2008