Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970·945-8212 Fax: 970·384-3470 Inspection Line: 970·384-5003 Building Permit No. ~-LI () /__,_L/ __ _ Parcel No: 2179-123-00-371 -----~~------" ------~-------- Locality: Lot OO~~BJk Oc::O ________ ~ Use of Building: ---Storage & indoor pa~~ir"Jg Owner: ________________ C-=-:a=n::.:be"'rr(l_{:;gJ1prete Pumping North Americ<!__ _______________ _ Contractor: Owner -----~-----·----~------=---"~-- Fees: Plan Check: $ 287-14 Septic: ---~·~'··~--·--·~ ----~-~--·-----~---"--··-· Bldg Permit: $ 441.75 Other Fees: -------------·--- Total Fees: $ 728.89 Clerk: ~JLfbh Date: __ :fl1/i2~ I I 2 3 4 5 6 7 8 9 10 II 12 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8ili Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfie1dMcountv.com Parcel No: (this information is available at the assessors office 970-945-9134) 2179-123 00-371 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal desr;ey~n Lot 008 of Section 12; Township 6 South; Range 92 West; 6th P.M. \ ~ Gv<:3rf N c Lot No: 008 Block No: 00 Subd.l Exemption: Owner: (property owner) Mailing Address: Ph: Alt Ph; Canberra Concrete Pumping North Americ 1912 CR 311 New Castle co 81647 970-876-0912 Contractor: Maili'l:li Address: Ph: 970-876-0912 Alt Ph: Canberra Concrete I>umping North Americ 1912 R 311 New Castle CO 81647 c'},lliJ'~~'i%fJ'JliH~~f~ms Mailinf Address: Ph: AltPh: .0. 80 72 Mount Pleasant, IOWA. 52641 319-285-8001 Sq. Ft. of Building: 3200.6 Sq. Ft. or Acres of Lot: 5 . 0 0 2 acres Height: 2 0 , 9 5/8 No. ofFJoors: Use of Building: Storage and indoor parking_ of concrete pumping vehicles and associated eguiptment Describe Work: Expansion of current Facilities to include 3200.6 square feet added Class of Work: oNew o Alteration i!l Addition Garage: NA Septic: o Attached 0 Detached o ISDS o Community l)riv~~a~_~it: .Ex~stirlg <SUe j:H i3;t;a:ee Owners valuation of Work: $30,000.00 r~ .r-, 'f'{(,'f ~ ' ·.-'! '1~,-m~<~-NOTICE Authoritv. This application for a Building" ermit must be signed by the Owner of the property, described above, or an authori;r,cd agent. If the signature below is nOt that of the Owner, a sepamte letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Pennit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate pcnnits may be required: (l) State Eleelrical Pennit, (2) Com1ty ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby cerlify that I have read this Application and that the information contained above is true and correct. 1 understand that the Building Department accepts the Application, along with the plans and specifications and otl1cr data submitted by me or on my behalf(submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Pennit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department. In considemtion of the issuance oft11e Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable lw1d use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or usc of the strncture(s) and faeility(ies), described above, arc not in compliance with County Rcgulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work I further acknowledge that the issuance of the Building Pennit does not prevent the Building Official from: (I) requiring tlte correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ics) if such is in violation of County Regulation(s) or any other applicable Jaw. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I HEREI:..y A~OWLEDGE TH2~ VE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE' L· ;!_, :d-.,_<!Mll 3-.tl-t~.rr i/OWNERS SIGNATURE' DATE / STAFF USE ONLY Special Co~itions: f'J O\t: Manu home Fee: Mise Fees: ISDS Fcc: Total Fees: Fees Paid: ;)5?'])'--(. ltoi L)' D7/ tf o8 No & Issued Date: Setbacks: OCCGroup: Zoning: DATE rt" The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. l understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be scaled by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade I line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IBC, IPC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes V 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes v Not necessary for this project __ _ 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes-l.£:_ 4. Is the l.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes Not necessary for this project. __ ./_ r . . 1:-.~\$"'\\Vl~ 2 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes ./ Not necessary for this project __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the building code or per stamped engineered design? Yes__'!{__ Not necessary for this project __ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes_L Not necessary for this project __ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes __ Not necessary for project~ 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes~ Not necessary for this project __ 10. Do the plans include design loads as required under the IBC or IRC for roof snowloads, (a minimum of 40 pounds per square foot in Garfield County)? Yes_./_ Not necessary for this project __ 11. Do the plans include design loads as required for floor loads under the IBC or IRC? Yes __L_ Not necessary for this project __ 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes _y_ Not necessary for this project __ 13. Is the wind speed and exposure design included in the plan? Yes v Not necessary for this project __ 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes _L Not necessary for this project __ 3 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes _L Not necessary for this project __ 16. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check a_pplicable zone district for building height maximum) Y es_v_ Not necessary for this project__ . 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Yes __ Not necessary for this project~ 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? Yes __ Not necessary for this project_L 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements ofthe IBC or IRC? Yes __ Not necessary for this project · / 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? /' Yes __ Not necessary for this project_V_ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? / Yes __ Not necessary for this project_¥_ 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes __ No Not necessary for this project .:/ 4 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Chapter 3) Yes__£_ Not necessary for this project'---- 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes __ Not necessary for this project~ 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes __ Not necessary for this project V" 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both s~es? Yes __ Not necessary for this project_v_ 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes __ Not necessary for this project v 28. Have two (2) complete sets of construction drawings been submitted witb the application? Yes v 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes V" 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes_L 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For comer lots see supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Yes / 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes V 5 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes_L_ 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes_L 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes_L 36. Are you aware that you must call iu for au inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes v 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes../ 38. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. ofl-Iighway Permit including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-860 I. See Phone book for other agencies Yes_L_ 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes__L 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to submittal of the building permit af>plication? Your attention in this is appreciated. Yes V 41. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes V (Please check with the building department about this requirement) 6 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes Not necessary for this project~ 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and specifications for the project. Yes _L_ Not Necessary for this project _____ _ I hereby acknowledge that I have read, understand, and answered these questions to the best of my ability. 3-d./·08 ~ignature Date Phone: 9'ltJ·&,)..'f ·8¥33(days); _.;,.;.·4m~cse'--____ (evenings) Project Address: 1'\ 1<-c.~ '3\l .. J ... w <As-r1e. C.O . ~ 1 c.&.\ I Note: On any of these questions you may be required to provide this information. If required information is not supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any ofthe questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 , ___ . ....,...,. ._. ..,.._. r.....vv f -r .. v ... 1 1 • Oct 30 07 03:03p Jit~~mM Smith 970-625-8435 WAGON WHEEL CONSULTING, INC. JIMMY W. SMITH 111 E.3RD STREET.SUITE213 RIFLE, CO 81650 OFFICE: (970) 625-8433 FAX: (970) 625-8435 Date: October 30, 2007 Gadield County Bwlding & Planning Deparbnent 108 s"' Street, Suite 401 Glenwood Springs, CO 81601 Re: Agent Authorization To: Garfield CoWlty Planner p.2 Wagon Wheel CoiiSllltiug, bro. (Jimmy Smith) bas been retained by Mr. Guy Middleton, . Owner of Canberra Concrete Pumping, bro., to request a Garfield County Special Use Pennit for a shop and lruek parking building expansion project. The project address is 1912 County Road3ll, NewCastle, CO 81647. l hereby authorize Wagon Wheel Consulting, Jnc. to act as agent on my behalf for all matters reganling the SUP applieation process. Please contact nie at (970) 876-0912 if you have any questions or concerns. Sincerely, Guy Middleton 26 June 2008 Re: Canberra Concrete Special Use Permit 1912 County Road 311, New Castle, CO 81647 This is to certify that footers and foundation were designed and built to meet all Garfield County requirements and all associated building codes by reference. Hiroko Akima P.O. Box 667 Tabernash, CO 80478-0667 303-594-6000 \ Bill To: Garfield County Road and Bridge Department P.O. Box426 Rifle, CO 81650 Phone-(970)625-8601 Fax-(970)625-8627 Invoice Driveway Permit Number: GRB08-D-38 Invoice Date: 3/26/2008 Canberra Concrete Pumping 1912 CR 311 New Castle ,Co 81647 $75.00 per Driveway Permit. Driveway Permit Fee: $75.00 -··~---~------"·"'~····~---~---~--- Total Due: $75.00 Thank You! Garfield Application for Driveway Permit Person Obtaining Permit: Canberra Concrete Pumping Application Date: 3/2612008 County Road Number: 311 District: Silt Permit Number: GRB08-D-38 Termination Date: 4/26/2008 Inspector: Jake Mall hereby requests permission and authority from the Board of County Commissioners to construct a driveway approach ( es) on the right-of-way off of County Road,.1!1_, 350ft West of Colorado River Rd, located on the North side of road for the purpose of obtaining access to property. Applicant submits herewith for the consideration and approval of the Board of County Commissioners, a sketch of the proposed installation showing all the necessary specification detail including: I. Frontage of lot along road. 2. Distance from centerline of road to property line. 3. Number of driveways requested 4. Width of proposed driveways and angle of approach. 5. Distance from driveway to road intersection, if any. 6. Size and shape of area separating driveways if more than one approach. 7. Setback distance ofbuilding(s) and other structure improvements. 8. No unloading of equipment on county road, any damage caused to county road will be repaired at subdivision expense. 9. Responsible for two years from the date of completion. General Provisions I) The applicant represents all parties in interest, and affirms that the driveway approach (es) is to be constructed by him for the bona fide purpose of securing access to his property and not for the purpose of doing business or servicing vehicles on the road right of way. 2) The applicant shall furnish all labor and materials, perform all work, and pay all costs in connection with the construction of the driveway(s). All work shall be completed within thirty (30) days of the permit date. 3) The type of construction shall be as designated and/or approved by the Board of County Commissioners or their representative and all materials used shall be of satisfactory quality and subject to inspection and approval of the Board of County Commissioners or their representative. 4) The traveling public shall be protected during the installation with proper warning signs and signals and the Board of County Commissioners and their duly appointed agents and employee shall be held harmless against any action for personal injury or property damage sustained by any reason of the exercise of the Permit. 5) The Applicant shall assume responsibility for the removal or clearance of snow, ice, or sleet upon any portion of the driveway approach (es) even though deposited on the driveway(s) in the course of the County snow removal operations. 6) In the event it becomes necessary to remove any right-of-way fence, the posts on either side of the entrance shall be surely braced before the fence is cut to prevent any slacking of the remaining fence and all posts and wire removed shall be turned over to the District Road Supervisor of the Board of County Commissioners. 7) No revisions or additions shall be made to the driveway(s) or its appurtenances on the right-of-way without written permission of the Board of County Commissioners. 8) Provisions and specifications outlined herein shall apply on all roads under the jurisdiction of the Board of County Commissioners of Garfield County, Colorado, and the Specifications, set forth on the attached hereof and incorporated herein as conditions hereof. 9) Final inspection of driveway will be required upon completion and must be approved by person issning permit or representative of person issuing permit. The inspection and sign off must be done prior to any CO from the Building and Planning Department being issued. 1 0) Contractor agrees to all Provisions in Exhibit A. Special Conditions: 1. Driveway Width-30ft 2. Culvert required? False Size: by 3. Asphalt or concrete pad required? True Size of pad: 30ft Wide x lOft long x 4in thick 4. Gravel portion required? True Length: 100ft 5. Trees, brush and/or fence need to be removed for visibility? True 6. Distance and Direction:180ft west of existing southeast entrance 7. Certified Traffic Control Required? True 8. Work zone signs required? True In signing this application and upon receiving authorization and permission to install the driveway approach (es) described herein the Applicant signifies that he has read, understands and accepts the foregoing provisions and conditions and agrees to construct the driveway(s) in accordance with the accompanying specification plan reviewed and approved by the Board of County Commissioners. Permit granted 3/26/2008, subject to the provisions, specifications and conditions stipnlated herein. For Board of County Commissioners' of Garfield County, Colorado: j;}u} tJ[W2J Representative of Garfield County Road and Bridge Signature Specifications I. A driveway approach is understood to be that portion of the county road right-of way between the pavement edge and the property line that is designed and used for the interchange of traffic between the roadway and abutting property. 2. At any intersection, a driveway shall be restricted for a sufficient distance from the intersection to preserve the normal and safe movement of traffic. (It is recommended for rural residence entrances that a minimum intersection clearance of 50 feet be provided and for rural commercial entrances a minimum of I 00 feet be provided.) 3. All entrances and exits shall be so located and constructed that vehicles approaching or using them will be able to obtain adequate sight distance in both directions along the county road in order to maneuver safely and without interfering with county road traffic. 4. The Applicant shall not be permitted to erect any sign or display material, either fixed or movable, on or extending over any portion of the county road right-of-way. 5. Generally, no more than one approach shall be allowed any parcel or property the frontage of which is less than one hundred (I 00) feet. Additional entrances or exits for parcels having a frontage in excess of one hundred I 00) feet shall be permitted only after showing of actual convenience and necessity. 6. All driveways shall be so located that the flared portion adjacent to the traveled way will not encroach upon adjoining property. 7. No commercial driveway shall have a width greater than thirty (30) feet measured at right angles to the centerline of the driveway except as increased by permissible radii. No noncommercial driveway shall have a width greater than twenty (20) feet measured at right angles to the centerline of the driveway, except as increased by permissible radii. 8. The axis of an approach to the road may be at a right angle to the centerline of the county road and of any angle between ninety (90) degrees and sixty (60) degrees but shall not be less than sixty (60) degrees. Adjustment will be made according to the type of traffic to be served and other physical conditions. 9. The construction of parking or servicing areas on the county road right-of-way is specifically prohibited. Commercial establishments for customer vehicles should provide off-the-road parking facilities. 10. The grade of entrance and exit shall slope downward and away from the road surface at the same rate as the normal shoulder slope and for a distance equal to the width of the shoulder but in no case less than twenty (20) feet from the pavement edge. Approach grades are restricted to not more than ten percent (10%). 11. All driveways and approaches shall be so constructed that they shall not interfere with the drainage system of the street or county road. The Applicant will be required to provide, at his own expense, drainage structures at entrances and exits, which will become an integral part of the existing drainage system. The Board of County Commissioners or their representative, prior to installation, must approve the dimensions and types of all drainage structures. Note: This permit shall be made available at the site where and when work is being done. A work sketch or drawing of the proposed driveway(s) must accompany application. No permit will be issued without drawing, blueprint, or sketch. BOARD OF COUNTY COMMISSIONERS OF GARFIELD COUNTY CERTIFICATION AND AFFIDAVIT REGARDING ILLEGAL ALIENS The cOntractor, whose name and signature appears below, certifies and agrees as follows: 1. The Contractor shall comply with the provisions of C.R.S. 8-17.5-101 et seq. The Contractor shall not knowingly employ or contract with an illegal alien to perform work for the Board of County Commissioners of Garfield County, Colorado ( ''BOCC") or enter into a contract with a subcontractor that knowingly employs or contracts with an illegal alien. 2. The Contractor represents, warrants, and agrees that it has verified that it does not employ any illegal aliens; that it has participated or attempted to participate in the Basic Pilot Employment Verification Program administered by the Social Security Administration and Department of Homeland Security; and otherwise shall comply with the requirements of C.R.S. 8-17.5-102(2) (b). 3. The Contractor shall comply with all reasonable requests made in the course of an investigation under C.R.S. 8-17.5-102 by the Colorado Department of Labor and Employment. If the Contractor fails to comply with any requirement of this provision or C.R.S. 8-17.5-101 et seq.", the BOCC may terminate work for breach and the Contractor shall be liable for actual and consequential damages to the State. 4. If the Contractor is a sole proprietor, the undersigned hereby swears or affirms under penalty of perjury under the laws of the State of Colorado that (check one) : ~I am a United States citizen, or I am a Permanent Resident of t·he Uni t·ed StateS, or I am lawfully present in the United States pursuant to Federal law. I understand that this sworn statement is required by law because I am a sole proprietor entering into a contract to perform work for the BOCC. I understand that state law requires me to provide proof that I am lawfully present in the United States prior to starting work for the BOCC. I further acknowledge that I will comply with the requirements of C.R.S. 24-76.5-101 et seq. and will produce the required form of identification prior to starting work. I acknowledge that making a false, fictitious, or fraudulent statement or representation in this sworn affidavit is punishable under the criminal laws of Colorado as perjury in the second degree under C.R.S. 18-8-503. CERTIFIED and AGREED to this ~ day of ~' 200 __ . FEIN or Social Security Number le Permit Number: GRBOS-D-37 Exhibit A · Inspection Report COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT I CORRECTION NOTICE Page 1 of 1 Date Received: 06-MAY-09 Permit Number: 664134 Contractpr/Homeowner: Address: Type of Inspection: Action: Comment!> or Corrections: Inspectors Name: Robert Fuller Phone Number: 970-947-8902 BZ EJ,ECTRlC 1912 County Road 311 Final Accepted /Date: 06-MA Y -09 COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCiES 1580Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https://www.dora.state.co.us/pls/real/Ep _Web _Inspection_ GUI.Process~Page 9/25/2009 THUNDER MOUNTAIN TE~TlNG ••• 2973 F. Road + Grand .Junction, CO 81504 (970) 256-9%5/ Cell (970) 210-7008/ FAX (970) 314-7067 Canberra Co~t&rete Pumping, Inc. 1912 County Road 311 New Castle, CO 81674 ATIN: Ms. Amanda Howell RE: Canberra Building Expansion 1912 County Road 311 New Castle, CO Dear Ms. Howell. September 29, 2009 Permit #11014 As requested, structural steel special inspection was conducted per the me 2003 Edition • Chapter 17: Structural Tests and Special Inspection and Garfield County requirements. I arrived on site at 10:45 AM. I met with you to review project specifications and requirements. The pre-engineered metal building manufacturer for this project is Ceco Building Systems in Mount Pleasant, IA. Ceco Building Systems is an AISC Approved Fabricator; therefore, shop inspection is not required per the me. The steel erector is Rocky Mountain Steel Structures in Silt, CO. Visual inspection was conducted at the Roof Framing Plan level on the %" ASTM A325 High Strength beam to beam and beam to coiumn bolted connections. Project bolt tension requirements indicate "Snug Tight" as referenced on the supplied project drawings provided by Ceco Building Systems: Job No. 1l·B· 74735-1 dated 6/12/09: Sheet No. CVl ofl; Building Specifications, Item 5. As a minimum, 10% of all connections, but not less than two bolts per connection were inspected fur proper bolt tension requirements as required for Periodic Inspo.,"tion per Table 1704.3 -Item 2.a per Chapter 17 of the me. Inspection was conducted at grid line A-D & 1 -4. Bolted connections inspected were observed to be adequately tensioned per project requirements.