HomeMy WebLinkAboutEngineer ReportGarfield County Community Development Department 108 St St, Suite 401 Glenwood Springs, co 81601 2575 HWY 6 & 50 GRAND JUNCTION COLORADO, 81501 2/23/2016 Please find included Gary Reeder's engineer final report for the project we did for Don Anderson, 5201 County Rd 346, Slit CO 81652. Thank you I Catherine Lenhart Office Coordinator PHONE: 970-243-2022 FAX: 970-243-9940 Foundations11gportCo.com ~--------------------------- February 19,2016 TO: Mr. and Mrs . Don Anderson 5201 CR346 Silt, CO 81652 coyote _gette r@ yahoo .com Gary R. Reeder, P .E. Reg is t ere d Professional Engineer 2937 Four Comers Drive, Grand Junction, CO 81503 cell: 970/250-9242 e-mail: garyreeder34@gmail.com RE: Underpinning (Piering) Project -Final Report 5201 CR346 Silt, CO 81652 The underpinning (piering) project has been completed utilizing the nine (9) push piers along the front south wall and around the SE and SW corners. The attached drawing "Final Elevation Survey" shows the final elevations at the main-level floor. Comparison of the final elevations this date and the initial elevations on February 2, 2016, shows the following : • along front wall initial ±1-1/2 11 final ±7/8 11 • along west wall initial ±3-1/4" final ±5/8" • along east wall initial ±2" final ±3/4" • along north wall initial ±5/8" final ±5/8" • Residential Structural Inspections • Foundation Design and Piering 5201 CR346 page 2 February 19 , 2016 Since piering was done only at the south wall and around the south comers, the largest difference is noticed at the south half of the house. For example, the elevation difference along the west wall in the master bedroom initially was 3", compared to post-lift elevation difference along this master bedroom wall of 3/8". Similarly, in the living room the initial elevation difference along the east wall was 2" while the post-lift elevation difference is just 1/8 11 • The final post-lift elevation difference along the south front wall is 7/8", still being the lowest at the SW comer. Additional lift may have been attained but a couple piers were starting to "max-out" and thus, it was determined to stop the lift. It is very rare that structures can be made perfectly level, although that would always be preferred. The piered portion of the house is deemed to be stabilized. The push piers were installed in accordance with the manufacturer's recommendations and specifications . The lift was accomplished in a proper manner by personnel from Foundation Repair of Western Colorado (FRWC). Please call me if you have any questions. Respectfully submitted, G&y!:ae~; co #19404 attachments (I) cc: FRWC Gary R. Reeder, P.E. • 2937 Four Comers Drive • Grand Junction, CO 81503 ,, ...-%+---~ . ·~ \. c 0 · ~ ...__ ' '=i -s,n1- I ... .. ii.--;:o .... -- •• ::.:; ' I -' \ - \ 1 t ~· \ ~;ft, in\• :' u* .,., I ':t ,., J • l -.? r ~ t ~ r~~ ' ~ ~ . ...,. 1= "'JI: I'\ - \ ~ ' ' R . .__ -.. ,;Yr+- • 2 - ~ "' ~ Q_ ' \ ,., I\ 4--.~ t= ----.. _,.....=:::?=---~-·----i-1 ~ & ·- ' .lT -I ~--' * t .j ~:ii. '::'- ' .'1 >" -1 r •o _, ••