Loading...
HomeMy WebLinkAboutApplication- Permitii f t GARFIELD COUNTY BUILDING, SANITATION, and PLANNING DEPARTMENT 109 8t1, Street, State 303 Glenwood Springs, CO 81501(970) 945-8212 No. 7950 GARFIELD COUNTY BUILDING PERMIT APPLICATION TELEPHONE: (97 i) 945-8212 GARFIELD COUNTY (GLENWOOD SPRINGS), COLORADO PERMIT NO. ,SO INSPECTION LINE: (970)384 5003 _ PARCEL/SCHEDULE NO. C 17" 1 X1-3 - co - /5 ti JOB ADDRESS: ?OL1 1\ as ! 1\ \v -u{ c, pb_57) 1 J LOT NO.r.rg cL .( BLOCK NO. SUBDIVISION/EXEMPTION f (4"- T{` L. 2 OWNER �.,4/ 4— 'G� ADDRESS _ 7e) % A1)4�/ P� Za 7 'RIFLE PH WK FR: 3 SArB W MO J"#fr IA) . cG�c)!� IQ,tU pU C� ADDRESS , OS31 A i 04 -)Pc p PR: J 7n - H: - b)6)6$ LIC. NO: 4 ARCIIFFECf/EN3INEFR ADDRESS PIES -140'3106 YfCHO: 5 SQ. FT.OSBtIILDING //�� act FF.OFLOT / inEcGur NO. OF FLOORS 6 USE OF BUILDING JAS i Deal c. IA L klit &A4-1 r� L. y 7 ...90.18Eworx. kto, T , b...-) /z) jS /4' /,VC) QStF 5'I'rT110rG R'r�tr IOrx,tI ' PcsRCI 8 Un CLASS OF WORK: °NSW 6Ff10N °ALTS ATION °MOVE 7 oPFMOVE i GARAGE; °SINGLE °DOUBLE CARPORT: asINOLE isn011BLE 10 ° DRIVEWAY PERMIT cow SIIEsEWAGEDISPOSAL (SEPTIC) °SrrB PLAN VALT/AIIONOF'ROMS 1, ` r---..^." ADDS= VALUATIONS VA)co/5 . _ SPECIAL CONDITIONS' NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. T1318 PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OE 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR. CANCEL P 1' PROVISIONS OF ANY OTHER STATE OR LO • • • • ' TRIG ONS rgUCTION OR THE PERFORMANCE OF • STRU i II// A PLAN CHECK FEE: -4 (S 44.2.( PERMIT FEE:Ye ^ C. T7 ` 7_,S - TOTAL FEE:fr DATE PERMIT ISSUED: [ ( . CI OCC: GROUP: n �� CONST: TYPE: V- �! 1L r ZONING: SETBACKS: Signature of .11%.. tractor or autif • ized agent h d and =too ' e 6Dvo. .1 4 —( S'� Jijr, tr f ? % 1 !•pprova . HOME: ISDS NO. & FEE: BuildngDept. Apptava1JDate P...', Dept. sat AGREENIEiNT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDINGDEPARTMF.NI'. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUJLDING,CODES AND LAND USE REGULATIONS ADOPTED BY GARFIE:LD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER PURGER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY TIIEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. TBE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUUI DING OFFICIAL FROM THEREAFTER REQI)IRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FRO PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDU& 1I I) THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBIITTJES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHI'T'ECT, DESIGNER BUJS.DEE. AND OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Gar qrm} 0k, 4� I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE. (INITIAL) ft i1, ,,/o r 11_40621 '7 oei 0155 ieLereL, /& 7 X?• c= /1 c 'o . a a /60 ifs 1. OD - /<(q0 a P-eA/L± ,231. H z n. z co 0 ILI CC 0 0 0 cc a W 0 m 0 cc I.L. O z 0 CORRECTION NOTICE CORRECTION NOTICE o m o +4 -a 0 Ur 0 0 c t 'CN 4 N 41 co a. c 2 0 •� 0 ..+! 4 CO i if Qi TOo O N y 0 (,) x ,i D •..6 C d to o gZ i 4 sl co Ci.c r " N N + 10 -0 V .a. o ?y 4) 03 ! t yco 0Mco z d KL .:Q 0 O N 2 , a a �- o 0 of •tT El o -a CD c of N 2 _c a o Na. 0 12 csi to. ;- 0 O N W 0 CP ;Fa C? c f� , �c c 0 0, a. vl.=r CO k\ N 0 c eit 11 7 3 f . 4:2 -0 NO 0 r vZ .0 cl in 0) E o -3 a 0.a E o .o .d co a o w 0— 0 c o .o cClao E ti o 0 c m � '8 L L w o a t o .fa a) c 4. S isi .0 , .. x o c 4 0 t7 N N v o 'w.c a) ).• o 3 m ci i Date: /l /%4 3 Garfield County BUILDING & PLANNING DEPARTMENT Code Compliance Office shy.ekettna arfie1d-eounty.earn Dear Pewit Holder, Please refer to your building permit number 7 ,.issued A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since. J'9 7- 2-- Please be advised that building permits expire, per Uniform Building Code, section 106.4.4. "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days fromfthe date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work bas commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do SQ, and the fee therefore shall be one half the amount required for a new permit for such work, provided no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceed0d one year. In order to renew action on a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing; to advise us about the status of your permitted work. If you have not responded within thirty days from the receipt of this notice the permit will be closed, and a permanent notation will be placed in the property records at the County Assessors office that indicates that the work permitted was not inspected, is not approved and that the building or area may not be legally occupied. /5: '"" 411"4"-laki" A p . Thank you for your cooperation. �7 / ..i� Sincerely, GG�it e = mi .�foffiiday f-i,c; Dave dead j € j Building Inspectors 108 8th Street, Suite 201, Glenwood Springs, Colorado 81601 Date A. „Vt 767, 3 To: Ai. -t-t-e-ee 7o Ape_/ Q YI6s-6 Garfield County BUILDING & PLANNING DEPARTMENT Dear Permit Holder, Please refer to our previous letter, dated //-/ 7-c 3 , advising you that your Building Permit; number '%% , was due to expire, per section 105.4.4 & 5 ofUniform Building Code, and that you bad been given an additional thirty days to call for the required inspection arta request other action from the building department. The above permit has expired and been closed. The work authorized by the permit has not been inspected or approved. It is a violation of Colorado Revised Statutes 30-28-205 & 210, Uniform Building Code section 109, to use or occupy the building or area unless final inspections have been completed and a Certificate of Occupancy has been issued. Records ofthis failure to comply are included with property records at the Garfield County Clerk and Recorders office. You are entitled to protest this, action to the Garfield County Board of Commissioners Yours truly, L(CI1 Andy Schwaller Building Official 108 8117 Street, Suite 201, Glenwood Springy, Colorado 81601 BEST core 00 "0 t -dPli a 2 0 . wrf 0x - 21 M n o M NI e iaat FO Cli - i „.° g m r a Pis x\ 5 ix., I �, c (11 ca h PL. 0 d u CFr 0 ± 0. zs e. b 2U J/ t'� 04170,8E0LS:Oi SEMS -S29-046 %HMG JA-13:WOdd 1 : T b002-2.0-NUf January 1, 1999 Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheating, house - rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40# per ft. up to 7,000 F.O.S. and an 80 M.P.H. wind. All sheets to be identified by number and indexed. All ofthe above requirements must be met oryour plans will be returned. 1. Is a site plan included that indicates the distances of the proposed building or addition to propertylines, other buildings, setback easements and utility easements? Yes 2. Does the site plan include the location of the I. S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties), streams or water courses? Yes C><---. 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes rit 4. Do. the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 2 3 6. Do the plans indicate the size and location of ventilation openings for the attic, roofjoist spaces's and soffits? Yes Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes t7--, 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes (>--. 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 10. Does the building section drawing or other detail include the method ofpositive connection of all columns and beams? Yes 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes C, 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No D< Wtoi- 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No I< /V f,+ 14_ Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes— No 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ve., No 3 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes p` No 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 18. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 19. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes v2, No 20. Will this be the only residential structure on the parcel? Yes No If no -Explain: 21. Have two (2) complete sets of construction drawings been submitted with the application? Yes 22. Do you understand that the minimum size a home can be on a lot is a 20ft. x 20ft.? Yes No 23. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 24. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 25. Do you understand that approval for design and/or construction changes are requiredprior to the application of these changes? Yes No 26. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes o‹, No 27. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 4:00 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes 1 No 28. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes pL No 29. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project com lying with the Uniform Building Code? Yes No 30. Are you aware that prior to issuance ofa building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes es- No 31. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes C>1-. No 32. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance of a building permit? Your attention in this is appreciated. Yes No 5 Thereby acknowledge that I have read, understand and answered these questions to the best of my ability. a4/66./.01 signature date Phone: 77 - 37 6 - 3 G.6 (days); Project Name: -. M., 976 Z. t, - '317/9/ (evenings) F- i rC Lt — PY 'D L! r •r—'s cy K1 Project Address: 7 6 L b u . 9 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 8/00 6 04/1112001 10:42 970-876-066B • SNOWY MTN INTERIORS PAGE 01 ti i. PP i5 1 g: 6:7 co t 1 R ca flet 0. Xl P M. al = w 0 a n P 41 46 sn, talo .5 wit S CSR , 0 - P �0€ 2 *.4 s`4. 0.#a . sv =,erg`. 41 011cr ....4.-@ Fp* 6 FA iC j CO cri s• s. ,quair . W ...— =40,Dfes = co i CDn 1059 P a n:gle Faintly Residential Addition 2x rafters spaced " O.C. or Manufactured Trusses spacedZ?'t" Q.C. (example: 2x 10 Reefs Spaced 24' O.C.) Minimum lx ridge board (example: 1 x 12) 12 pitch NOTE: Roof not to exceed 24 foot span Sheathing /z -ti ex (example: 1/2'extenerplyrQd) Roof covering �Yr (exrrnp/e: ClassA 31ab shingles) Underlayment>� (example: 2layers 15# fell) Ceiling Insulation (example: R-30) Note: Attic ventilation and access may be required Provide solid 2x blocking between rafters or trusses Wall Insulation '9-.,-.1",:s F-, i' (example: R•13Fiberg/ass Batts) Note: Pre-engineered roof trusses • wltruss clips and hardened nails may be used in lieu of roof structure shown. Diagonal wind bracing or plywood shear panels @ corners and each 25' of wall. Note: Pre-engineered floor systems may be used and should be installed according to the manufacturers installation instructions. c•dingjoists @ 2' r0.C: (example: 2x8 6 24' 0..C.) Double 2x top plate (example: 2x4) Span '27 / (example: 23'57 1 Ceiling height (example: 8) Siding -r-%1 � erg j (example: lap or7 111) • • • • A • . . . • • • • 18" minimumfrom the interior grade level to the bottom of the floor joists. • • • Engineered Design: Cessions may be required if your site has swelling soils. A foundation designed by a Colorado licensed architect or engineer may be required. • • ti Wall sheathing i42 ` 5ei (example: r4' exienorply»vc ) studs @ !44 o.c. (example: 2 x 4 2 24' O. C.) Cont. 2x sill plate (example:2x 4) 2x .. oasts @ O.C. • © Foundation: Engineered Design 0 Foundation: Detail A (see pane 3) *'+....+ Property Address• fr76 Cc'h�lAJ"7-. iz�.l This handout was developed by the Colorado Chapter of the international Conference of Building officials as a basic plan submittal under the 1997 Uniform Codes. it is not intended to cover all circumstances. Check with your Building Department for additional requirements. Permit it; (example: 2e10 024' O.C.) Wall width S " (example:8') Footing size '6 `x (example: 8'X 16`) s ' .4 No. 7950 5C Assessor's Parcel No BUILDING PERMIT CARD Job Address 104 CR 2,59) 91Rf- L _�- Owner Contractor ¶VIiC PILT,OVAL Date q/20/0 Address'jOLICR 5 Rift. Phone # Address i 14L01..04-, 510i Phone #'4,Cfat44 Setbacks: Front Rear RH 1-T1o1J LO kA0m+G� -KCt- INSPECTIONS Soils Test Footing x`7.,1.-6( 0, Foundation 4--31-OI' Grout Underground Plumbing Rough Plumbing Framing insulation Roofing Drywall Gas Piping NOTES LH Zoning Weatherproofing Mechanical Electrical Rough (State) Electrical Fin I (State) '4-7-0 Final / 7.- lChecklist Completed? "0/ Certificate Occupancy # Date Septic System # Date Final 471( Other (continue on back)