HomeMy WebLinkAboutApplication-PermitGarfield County
Building & Planning Department
108 8th Street, Suite #401 Glenwood Springs, Co. 81601
Office :970·945·8212 Fax: 970·384-3470
In spection Line: 970·384-5003
Building Permit No. 0 (Q ~
-------
Parcel No : 2407-07 4-08-009
Locality: Willow Creek Village Sec1, blk8, Lot 9 -------
Job Address : 238 Wi llow Creek Trail , Parachute -------
Use of Building : add ition (liv ing qua rters & covered deck), _____ _
Owner : Gra jalez, Vanessa
~-----------
Contractor : Tom Lippitt Construction
~------------
Fees: Plan Check : $ 293.70 Septic :
Bldg Permit : $ 45 1.85 Other Fees : ---
Total Fees: $ 745.55
Clerk: Date:
~N~t. + ·. 4w. ,\ A-'i~IELD COUNTY BUI LDING PERM IT APPLICATION
2
3
4
5
6
,eff :tf Gl$ 9f!>fd t;' 1088'hStreet,Suite401,GienwoodSprings,Co 8 1601
Phone: 970-945-82 12/ Fax: 970-3 84-3470 I Inspecti on Line : 970-384-5003
www. !!arfield-county.com
Parcel No : (this infonnati on is available at th e assessors office 970 -945-9134)
~L.J O 7 -07 '-/-08-e?CJ
Ph: All Ph:
7 32G He ight: J /';1 r 'I //
No . of Floors:
8 Use of Build ing : L iut GuA
9 Describe Work:
10 C lass of Work:
oNew o Alterati on
]] Garag e: N/A Septic: N/4 o lS DS
12 Driveway Pe rmi t: N Owners val uat ion of Work:
NOTICE
Authority. This appli catio n for a Building Permit mu st be signed by the Owne r of ropen y, described above , or an authorized agent. If the signat ure below is not th at of the Owne r, a separate
lener of authori ty, signed by the Owner, mu st be provided with this Applicati on.
Legal Access. A Building Permi t cannot be iss ued without proo f of legal and adequa te access to the propeny for purposes of inspections by th e Building Depanment.
O the r Permits. Multiple separa te permits may be required: (I ) State El ec trical Permit, (2) Cou nty I SDS Penni~ (3) another permit requi red for use on the property ide ntified above, e.g. State or
Co unty Hi ghway/ Road Access or a State Wa stewater Di sc har ge Permit .
Vo id Pe r mi t. A Building Permi t becomes nu ll and void if the work au th orized is not co mmenced within 180 days of the date of issuan ce and if work is suspended or abandoned for a period of 180
days after commen ce ment.
CERTIFI CATION
I hereby cenify that I have read thi s Appli cation and that the information contained above is true and correct. I understand that th e Building Depanment accepts the Application. along with the plans
and specifico tion s and other dat.a submi ued by me or on my behalf (submi ttals), based upon my ce rtification as to accura cy.
Ass uming comple teness of the subminals and approval of this Application, a Building Permit will be issued granting permission to me , as Owner, to constru ct the structure(s) and facilities detailed on
the submitta ls revi ewed by the Building Depanment.
In conside ration of the iss uance of the Building Permit, 1 agree that I and my age nts wi ll comp ly wi th provisions of any fed e ral , state or local law regulating the work and the Garfield County Bui lding
Code, JSDS regu lations and appli cable land use regu lations (Count y Regu lati on(s)). I ackn owledge th at the Buildin g Permi t may be suspended or revoked , upon notice from th e Coun ty. if the loc ati on,
construction or use of the struct ure(s) and fa cility(ies), descri bed above, are not in complian ce with Cou nty Regulation (s) or any oth er applicable law.
I hereby grant permission to the Bui ld ing Depanment to e nter the pr operty , des cribed above , to inspect the work . I funher acknowl edge that the issuance of the Buildi ng Permit does not prevent the
Bui lding Official from : (I) req uiring the correcti on of errors in the su bmittals, if any, di scove red after iss uance; or (2) stopping co nst ruction or us e of the structure (s) or fa cili ty(i es) if such is in violation
of County Regulation (s) or any other applicable law.
Review of this Application, includin g submittals, and inspec ti ons of the work by the Building Department do not co nstitute an acceptance of responsibility or liability by the County of errors, omiss ions
or dis crepancies . As t11 e Owner, I acknowledge th at re sponsi bility for co mpliance with federal, state and loca l laws and County Reg ulations rest wi th me and my authorized agents, including without
limitation my archi tec t designer, engineer and/ or builder.
I HEREBY ACKNOW EDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTI FICATION ABOVE: v £" -23 -()
DATE
STAFF USE ONLY
Special Cond iti ons :
Adjusted Valuation : Pla n C heck Fee: Per mi t Fee: M anu h o me Fee: Mise Fees:
301393. g '213. 712 L/5/ fl.? -
I SDS Fee: T otal Fees: Fees P a id : Ba l ance Due: f\o~~Date : ISDS No & Issu ed Da t e:
·-;~5, 55 2 87. !.!t 458.ljj_ -,..._ -
Setbacks: O CC G r oup: Cons t Type: Zoning: PtA D
2SF; 15~, {;,S
BLDG DE PT: P L NG D E~ ~6 .y~~ ~3 ~
APPROVAL D AT E AP P ROVAL ATE
The following items are required by Garfield County for a final Inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all IBC and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED.
OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance of a
C.O. for the building identified in the Building Pennit.
DATE
VALUATION FEE DETERMINATION
Applicant
Address
Date
_cV~a~n:::;es!::sa=G.!.!ra:!!ja!!:le~z:...._ _______ Subdivision
..=2:;:.3~8 ,!.W!..!i.!.!llo~w~C~re::':e:":k~T~a.!.!il ______ Lot/Block
~8::.:17c:;i2~0::;0~8 ___________ Contractor
Finished (Livable Area):
Main
Upper
Lower
Other
Total
Basement:
Unfinished
Square Feet
Valuation
Conversion of Unfinished to Finished
Total Valuation
Garage:
Carport:
Total Valuation
Crawl Space
Total Valuation
Decks/ Patios
Total
Covered
Open
Valuation
Type of Construction:
Occupancy:
Valuation
Total Valuation
326 sq.ft
sq.ft
sq.ft
sq.ft X $74.68
326 sq.lt
sq.h X $41.00
sq.ft X $33.68
sq.hX $18.00
sq.h X $12.00
sq.ft X $9.00
252 sq.h X $24.00
sq.ft X $12.00
Commercial
sf X
sf X
sf X
sf X
sf X
sf X
Willow Creek Village, Sect I
Lot 9, Block 8
Tom Lippitt Construction
24,345.68
0.00
0.00
0.00
6,048.00
0.00
30,393.68
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan and
it's discovered that required information has not been provided by the applicant, this will result in the
delay of the permit issuance and in proceeding with building construction. The owner or contractor shall
be required to provide this information before the plan review can proceed. Other plans that are in line
for review may be given attention before the new information may be reviewed after it has been
provided to the Building Department.
TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE
SUBMITTED FOR ALL APPLICATIONS.
Please review this document to determine if you have enough information to design your project
and provide adequate information to facilitate a plan review. Also, please consider using a design
professional for assistance in your design and a construction professional for construction of your
project. Any project with more than ten (10) occupants requires the plans to be sealed by a
Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building, plumbing
and mechanical codes, applicants are requested to review the following checklist prior to and during
design. Applicants are required to indicate appropriately and to submit the completed checklist at
time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn
to scale.
I
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks,
balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and
original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house-rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed,
wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or your
plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
I. Is a site plan included that identifies the location of the proposed structure or addition and distances to
the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor
and has the surveyors signature and professional stamp on the drawing? Properties with slopes of
30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the
placement of any portion of a structure within 50 ft. of a property line and not within a previously
surveyed building envelope on a subdivision fmal plat shall be prepared by a licensed surveyor
and have the surveyor's signature and professional stamp on the drawing. Any structure to be
built within a building envelope of a lot shown on a recorded subdivision plat shall include a
copy of the building envelope as it is shown on the final plat with the proposed structure located
within ~nvelope.
Yes __ _
2. Does the site plan also include any other buildings on the property, setback easements and utility
easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the
property you are applying for a building permit on is located on a comer lot. Special setbacks do
apply.
Yes V
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal
System) and the distances to the property lines, wells (on subject property and adjacent
properties), streams or water courses?
Yes v
4. Does the site plan indicate the location and direction of the County or private road accessing the
property?
Yes V
2
5. Are you aware that prior to submittal of a building permit application you are required to show proof
of a legal and adequate access to the site? This may include (but is not limited to) proof of your
right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept.
of Highway Permit, including a Notice to Proceed; a permit from the federal govermnent or any
combination. You can contact the Road & Bridge Department at 625-860 I. See phone book for
other agencies
Yes v-
6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel
in accordance with the IRC or per stamped engineered design?
Yes V'
7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the
clearances required between wood and earth?
Yes ._....... No ____ _
8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and
soffits?
Yes ___ ....-' ___ _ No ____ _
9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of
40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind
loads?
Yes ....,--
I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?
Yes V
11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafters or joists or trusses?
Yes V"
12. Does the building section drawing or other detail include the method of positive connection of all
columns and beams?
Yes v-
13. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top
of a flat roof? (Building height measurement usually not to exceed 25 feet)
Yes .....-'
14. Does the plan include any stove or zero clearance fireplace planned for installation including make
and model and Colorado Phase II certifications or phase II EPA certification?
Yes NIA No _____ _
3
15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply
with the IRC?
Yes !11/-1 No _____ _
16. Does the plan include a window schedule or other verification that egress/rescue windows from
sleeping rooms and/or basements comply with the requirements of the IRC?
Yes !./""
17. Does the plan include a window schedule or other verification that windows provide natural light and
ventilation for all habitable rooms?
Yes ........-
18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing for these areas?
Yes V"" No ______ _
19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on
the plan?
Yes NFI
20. Do you understand that if you are building on a parcel of land created by the exemption process or the
subdivision process, are building plans in compliance with all plat notes and/or covenants?
Yes v
21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to
obtain written permission from the association, if required by that association, prior to submitting
an application for a building permit? The building permit application will be accepted without
it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in
revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans
have been reviewed by the Building Department prior to any action by the HOA that requires either
revocation or substantial modification of the plans.
Yes v'
22. Will this be the only residential structure on the parcel?
Yes v No Ifno-Explain: ______ _
23. Have two (2) complete sets of construction drawings been submitted with the application?
Yes __ -"'---
24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long?
Yes v-
4
25 o Have you designed or had this plan designed while considering building and other construction code
requirements?
Yes '-""'
260 Do your plans comply with all zoning rules and regulations in the County related to your properties
zone district?
Yes ~
27 0 Does the plan accurately indicate what you intend to construct and what will receive a final inspection
by the Garfield County Building Department?
Yes ,._,.-
280 Do you understand that approval for design and/or construction changes are required prior to the
application of these changes?
Yes '\,./
290 Do you understand that the Building Department will collect a "Plan Review" fee from you at the
time of application submittal and that you will be required to pay the "Permit Fee" as well as any
"Road Impact" or "Septic System" fees required, at the time you pick up your building permit?
Yes v
30o Are you aware that you must call in for an inspection by 3:30 the business day before the
requested inspection in order to receive it the following business day? Inspections will be
made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in
to 384-5003.
Yes V No ------
310 Are you aware that requesting inspections on work that is not ready or not accessible will result in a
$50o00 re-inspection fee?
Yes v-
320 Are you aware that you are required to call for all inspections required under the IRC including
approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the
building?
Yes ~
330 Are you aware that the Permit Application must be signed by the Owner or a written authority being
given for an Agent and that the party responsible for the project must comply with the IRC?
Yes V
5
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and
Plumber to perform installations and hookups, unless you as the homeowner are performing the
work? The license number of the person performing the work will be required at time of
applicable inspection.
Yes ~
3 5. Are you aware, that on the front of the Building Permit Application you will need to fill in the
ParceVSchedule Number for the lot you are applying for this permit on prior to submittal of a
building permit application? Your attention in this is appreciated.
Yes ~
36. Do you know that the local fire district may require you to submit plans for their review of fire safety
issues?
Yes ~ (please check with the building department about this requirement)
3 7. Do you understand that if you are planning on doing any excavating or grading to the property prior
to issuance of a building permit that you will be required to obtain a grading permit?
Yes v
38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees
have to be paid and the connections inspected by the service provider prior to the issuance of a
Certificate of Occupancy?
Yes v--··
Ihereby acknowledge that I have read, understand and answered these questions to the best of
my ability.
5-23-08
Signature of Owner Date
9 7 0 ·-2 S£'-7/68evenings)
Project Narne: __ _,6,._,_,R"--A_,";}"'-'A-'-'-'I....,_,E,_,2..~ _ _._,·Rc..::E"=-=5"-'-. __ 4.L..CJ<.D-""l>_,_! =:-1_,_1 0"-'N'-"------
9/D-285-Z/62,(days); Phone:
Project Address: 7..3 <3 ().) i 1/0u..) Ci?.ETK 18.41}._) }3./l(. 8/63S-
6
Notes:
If any required information is missing delays in issuing the permit are to be expected. Work may not
proceed without the issuance of a permit. If it is determined by the Building Official that additional
information is necessary to review the application and plans to determine minimum compliance with the
adopted codes, the application may be placed behind more recent applications for building permits in the
review process and not reviewed until required information has been provided and the application rotates
again to first position for review, delay in issuance of the permit or delay in proceeding with
construction.
BpminreqDec2007
7
GARFIELD COUNTY
BUILDING REQUIREMENTS
Codes: 2003 JRC, IBC, IFGC, IMC, !PC,
Setbacks: Check subdivisions and zone district for setback requirements.
Snowload (measured at the roof): 40PSF up to 7000ft. elevation.
Seismic design category: B
SOP SF 7001 to 8000ft.
75PSF 800I to 9000ft.
lOOP SF 900 I to I OOOOft.
Weathering probability for concrete: Severe
Termite infestation probability: None to slight
Wind speed: 90mph
Decay probability: None to slight
Wind Exposure: B or C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 800 I and above.
Winter Design Temperature: Minus 2 to 7000ft.; minus I6 over 7000ft.
elevation.
Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by
Building Official.
Ice shield under-layment required.
Mean Annual temp.: Variable
Insulation: Maximum glazing U factor: 0.50
Minimum R-Values:
• Ceilings/roofs R values are: R-30 stick built
structures. R-38 log construction and steel
rafter construction.
• Wails R values are R -19 wood frame; R-I 9
cavity R-3 sheathing steel studs.
• Floors R-values are R-19.
• Basement wall R-values are R-IO be!'ow
grade, R -19 above grade.
• Slab perimeter R-va!ue and depth is R-
10/36in.
• Crawl space wall R-values are R-IO below
grade and R -19 above grade
If floors over crawl spaces are not insulated, the crawl space walls must be
insulated. Basement wall must be insulated to frost depth. Common walls
garage to house must have R-19 insulation. Common ceiling/floor garage
to house must have R-19. Take precautions to protect plumbing in these
areas.
PLAN REVIEW CHECKLIST
Applican t_f1.L....:R.---'-,A--+-<f !t...:....o...;.;{ e...;;;..v __ _
J
Building
~Engineered Foundation
tv/11 Driveway Permit
/ Surveyed Site Plan
fJ/It Septic Permit and Setbacks
~Grade/Topography 30%
V Attach Residential Plan Review List
y! Minimum Application Questionnaire
V Subdivision Plat Notes
~Fire Department Review
L Valuation Determination/Fees
L Red Line Plans/Stamps/Sticker
vi Attach Conditions
/ Application Signed
_£_Plan Reviewer To Sign Application
/ ParceVSchedule No.
rJ/A 40# Snowload Letter-Manf. Hms.
V ___ Soils Report
GENERAL NOTES:
Date '7/7/o[
' I
Planning/Zoning
~ Property Line Setbacks
~30ft Stream Setbacks
If~ Flood Plain
L_suilding Height
_{_zoning Sign-off
if A Road Impact Fees
;v,!r HOAIDRC Approval
/ Grade/Topography 40%
~Planning Issues
/ Subdivision Plat Notes
COUNTY OF GARFIELD-BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone(970)945~212
Joblocatedat ;J38 tf)~J tud 7'~
Permit No. //06 2--
•
I have this day inspected this structure and these
premises and found the following corrections needed:
)feall for Re-lnspection
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Oat• /!)-3 ~
Building Inspector~
I
Phone (970) 945-8212
N 11062
0. ----------~~~-----Assessor's Parcel No. 2407-07 4-08-009
Date 8/12/2008
BUILDING PERMIT CARD
Job Address ----~2~3~8~VV~il~lo~w~C~re~e~k~T~r~a~ii~,~P=ar~a~c~h~u~te~(~VV~i~ll~o~w~C~r~e~e~k~V~il~la~g~e~S~c~e~1~,~b~lk~8~,~L~o~t~9L) __________ ___
Owner ________ ~G::.r:.:azja::.:l=ez::!,~V:..:a:.:.n~e=s=s=a __________ Address 238 willow creek trail, rifl!f:Jhone # 285-7168
Contractor Tom Lippitt Const Address 852 Antler rd, rifle Phone # 618-3220
Setbacks: Front _____ Rear _______ RH, ______ LH _________ Zoning ____ _
addition (living quarters & covered deck)
Soils Test -:::;c--:;~.-c--:;::---=-c-----
Footing &'-.;t:;l-Q3 ~
Foundation s-'2.1? oF;hVS
Grout __________________ __
Underground Plumbing.....,---~~-
Rough Plumbing /O-(p -o&flii}
Framing LD-(1. -08 ~
Insulation lfi-$ -D5 l<fui
Roofing----~------........,____..,..,_ ......... __ _
Drywall 11!-10 _agAbJ1
Gas Piping---~.:...=..:~--------
INSPECTIONS
Weatherproofing _____________________ _
Mechaniva•------------~---
Eiectrical Rough (State) _.L.J.~"'--~""-~--
Eiectrical Final (State)_!.!..-.!.2~<2...l
~Final£-/?-<?/' /Checklist Comp
Certificate Occupancy # -------------Date ____________ _
Septic System # ______________ _
Date ---------------Final ________________ __
Other ___________________ _
NOTES
(continue on back)
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
Date Issued_~----~~ ~-o_____,t~-Permit No.__._.II~O (p.,.__~.______ __
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations
related to the zoning, locationi construction and erection of the proposed structured for which this permit is
granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location,
erection and construction of the above described structure1 the permit may then be revoked by notice from the
County Building department and IMMEDIATELY BECOME NULL AND VOID.
Use QdtliDOn c liu\ng QoorTtrs .. coueretl ~PrJ.}
AddressorLegaiDescription A~'t \ll\\\Gl) ~lett Tm\L-P'~Gte
OwnerOI~bltl, 'J (lntM Contracto:lbW\ Llppin-eoY\1d".
Building Permit Type R ~~\df'Unl..
This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection
INSPECTION RECORD
Footing Driveway
cp -f)-?--0'6 ~
Foundation I Grouting Insulation
'3 ·;2"iS-D'6 ~ !D-5-o'S !JNL
Underground Plumbing Drywall
IV-/O-ff!, f}wv
Rough Plumbing Electric Final (by State Inspector) ()_/( TO dJOV(,r't
JO-{.p-0~ Gl1J\ /'ibi1'o ru o~~~ ,,__~~~k rv -r-t>-
ovn--vr.r-
(PriortoFinal) FiJ.u\' ruoo J1c.>, 1) (/Mbr!to -o.¥
Rough Mechanical Septic Final ~
/(!)-~-05 ~ ;V;~,~~
Gas Piping FINAL//-/ 7-<J!f ~~
'/1-(JJ
Electric Rough !by Mfttoa}:_o -3 -or {You Must Call For Final Inspection)
Notes {Prior to Framing) 7
Framing 10-&'0'i ~
(to include Roof In place & Windows & Doors installed & Firestopping In place)
THIS PERMIT IS NOTTRANSFERABLE
For Inspection Call970·384-5003 Office 970-945-8212
108 8th Street, Suite 401 Glenwood Springs, Colorado 81601
~::.ROVED ~-~-Ot DO::T.so;;;~j\o~\or
PROTECT PERMIT FROM WEATHER MAGE
(DO NOT LAMINATE)
Parcel Detail Page I of 4
Garfield County Assessor/Treasurer
Parcel Detail Information
Assessor/Treasurer Property S~gr;;_h I A~~ssor SubseLQJ.Lt;_f)' I Alls_e~sorSaks S~!trch
Clerk & Recorder Reception Sea[(;h
Basic B_tti1di_ngf:haracteristics I Tax Information
l'arc_e_L:Q~t<~il I Value Detail I Sales_DeJ!Iit I Resid5)ntiillLC_ommen:ial Improvement Oelail
Land Detail I PhQtogmp_~ I Mill Leyy Revenues Detail
I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I
I 080 II R490294 II 240707408009 II 38.002 I
Owner Name and Mailing Address
loRAJALEZ, ALVARO & VANESSA
1238 WILLOW CREEK TRL
!PARACHUTE, CO 81635-9640
Assessor's Parcel Description
)(Not to be used as a legal description)
lsECT,TWN,RNG:7-7-95 SUB:WILLOW
!CREEK VILLAGE SEC. I BLK:8 LOT:9
IPRE:R270157 BK:0601 PG:0658 BK:1690
IPG:450 RECPT:674935 BK:0965 PG:0990
IBK:0944 PG:0566 BK:0940 PG:OI28
IBK:0929 PG:0385 BK:0679 PG:0518
Location
I
I
I
I
I
Physical Address: 11238 WILLOW CREEK TR PARACHUTE! I
Subdivision: IIWILLOW CREEK VILLAGE SEC. I I
Land Acres: I 0
Land Sq Ft: 1115,139 I
Section II Township II Range I
7 II 7 II 95 I
http://www.garcoact.com/assessor/parcel.asp?Parce!Number=240707408009 7/15/2008
Parcel Detail Page 2 of4
2008 Property Tax Valuation Information
II Actual Value II Assessed Value I
I Land: II 44,oooll 3,5ool
I lm~rovements: II 211,72011 16,8501
I Total: II 255,72011 20,3501
AddiJional Value Detllil
Most Recent Sale
Sale Date: 115/24/2005
Sale Price: 11221,500
A>lditional Sales Detail
Basic Building Characteristics
Number of Residential 1 Buildings:
Number of Commllnd
jo I Buildings:
Residential Building Occurrence 1 Characteristics
OVERHANGING LIVEII16
NO/FOUND:
1 STORY: 111,894
TOTAL HEATED AREA: 111,910
li ABSTRACT CODE·IISINGLEFAM.RES-
. IMPROVEMTS
ARCHITECTURAL STYLE: III-STORY
EXTERIOR wALL: IIMASONITE
EXTERIOR WALL: IIBRICK VEN
ROOF COVER: llcOMP SHNGL
ROOF STRUCTURE: II GABLE
I INTERIOR WALL: IIDRYWALL
I FLOOR: llsHT VINYL
I FLOOR: llcARPET
I HEATING FUEL: IlGAS
II
http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=240707408009 7/15/2008
Parcel Detail Page 3 of 4
I HEATING TYPE: IIHOT WATER I
I STORIES: llsTORIES 1.0 I
I BATHS: 12
ROOMS: 17
UNITS: II
BEDROOMS: 13
YEAR BUILT: 111994 I
Additi_onal Residential/Commercial ImprQYJ!ment Detail
Tax Information
Tax Year II Transaction Type Amount I
2007 Tax Payment: Second Half ($386.68)1
2007 Tax Payment: First Half ($386.68)1
2007 Tax Amount I $773.361
2006 Tax Payment: Second Half II ($346.68)1
2006 Tax Payment: First Half II ($346.68)1
2006 I Tax Amount II $693.361
2005 Tax Payment: Second Half II ($450.67)1
2005 Tax Payment: First Half II ($450.67)1
2005 Tax Amount II $901.341
2004 I Tax Payment: Whole II ($1,093.66)1
2004 II Tax Amount II $1,093.661
2003 II Tax Payment: Whole ($1,165.56)1
2003 I Tax Amount $1,165.561
2002 Tax Payment: Whole ($1,129.40)1
2002 Tax Amount $1,129.401
2001 Tax Payment: Whole ($1,109.04)1
2001 Tax Amount $1,109.041
2000 Tax Payment: Whole ($1,483.60)1
2000 Tax Amount $1,483.601
1999 Tax Payment: Whole ($1 ,256.28)1
1999 Tax Amount $1,256.281
Mill Leyy Revenues Detail
http://www.garcoact.com/assessor/parcel.asp?Parce1Number=240707408009 7/15/2008