Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application- Permit
GARFIELD COUNTY BUILDING, SANITATION, and PLANNING DEPARTMENT 109 8th, Street, Suite 303 Glenwood Springs, CO 81601(970} 945-8212 Nature of work Use of Building Owner No. 7886 49- 4-et-girtarqd CIS/60/ },t Contractor, Amosmt of P � qbb • VG Date 337.fitrAesttylizie 017z, .4-D aS ekt c219. /so.uD 9oC .4I6 dap I 0 a„-,d,e,„ clack * , • GARFIELD COUNTY BUILDING PERMIT APPLICATION OARFIELD COUNTY (OIENWOOD SPRINGS), COLORADO INSPECTION LINE: (970)384-5003 TELEPHONE: (970) 9454212 PERMIT NO. 1884. PARCEL/SCHEDULE NO. _ S: ? elope r t 6.d 6 (8 . w ook s foci ne Co Y /bo f 1 LOT NO. BLOCK NO. SUBDIVISION/EXEMPTION 2 ��� "DE'LB` 47811y-4 5 _ 7s1-2. ,M ate- E 3 7- owRpAcran cal sf/{ycAv (xOLtd. ecud ed`445- ` uawo. 4 A►aaOtEcrEOR : uCI10: 5 6Q. rr. wild :Kr. _ �.`, IQFLOTr r . 1/ ac (7:71 �r )10.OFFLOM/ 7 4,r LpasE Wam 8 aA1.OF WOOF: OHM oADERION OAL1QAr1OFf MOVE taxmovE 9 =NOM °� Tyr 10 O LGMWAY PERM DON En @WAINDOIPOOAL arm oIIS FLM, VALUASWN OF WO $ MAL® VALVASSOM 423, ?So. Ca comma:PPICIAL NOTICE A SEPARATE EtECIRIGII. PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO, THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COI,NCED WITHIN 110 DAYS. OR IF CONSTRUCTION OR WORK 1S SUSPENDED OR ABANDONED FOR A PERIOD OF 1S0 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TILS SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING 11118 TYPE OF WORK WILL Be COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO WE VE A TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR W REON.ATD G CONSTRUCTION CPR THE PERFORMANCE OF 00 N. Dae 6/4,8k/ PLANHE /1[ %%PPO 124/ / rX° 3a 7 1 TOTAL FSB: r�L DATE PERMIT ISSUED: qV• .� , T OCC: GROUP' CONST: TYPE: , r R/y - 3 V— ZONING: SETBACKS: 8 of0wiar, Cadmic( ar a dvadiaed soot living mder�tood nalioo f ethiltiE,c9,12--, • dr, MENU. HOME: c)i/• op ISM NO. A PEE: /519r &dld5 D.$. APP Plroaios Dept . 1 ,. ° A(1RTF' a PERMISSION IS HEREBY (RANTED TO TIM APPLICANT AS OWNER CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY TIM BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT. TIM SIO I3R HEREBY AGREES TO COMPLY WITH ALL BUILDING {ODES AND LAND USE REGULATIONS ADOPTED BY OARFMLE COUNTY PURSUANT TO AurnoRITY GIVEN D4 30.21.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH W THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM TILE COUNTY AND THAT TWIN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL. NOT PREVENT THE BUILDING OFFICIAL. FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS 11.1 SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FRO PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IAT VIOLATION OF THIS CODE OR ANY OTHER. ORDINANCE OR REGULATION OFTHIS IURISDICIION. THE REVIEW OF 1IIE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND Dsip1TTATION DIMINO CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER. BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND 114 SUPPORT OF THE OWNERS INTEREST. Oufonn.003 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE ACIREEMENT ABOVE. QI4TflAL.1 (01 14.73y fcp The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, alt necessary plumbing; 4. A complete bathroom, with wash bowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1994 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATION PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy use and the issuance of a Certificate of Occupancy for the dwelling under building permit # �% a•Z' Signature bpcont •••40614. Date f 1 lh .114 XYg 4.1 , rob �. so 3gs7I! a., q2/05:`200). l 4.3: 29 30336:;7710 rE8-4601 TLE 11:41 Ali 0HAE1PION HOMES CnamPion HOME BUILDERS CO. "Leading The Way Nome" lebni iry 6, 2001 .... . Slwttcaw 1lonle, 2195 Souili Maid Strcwt Delta. CO 81416 Owlet: Address: Model: Serial #: Design Criwrin: Scletiener Nurse T.ictr:cl 05-762 Ul3C None Listed ILLC PAGE 0:' FAX NO. 1 402 1362 7724 P. 02102 1997 WIC, 1997 UPC, 1997 UMC:, and 1999 NEC UliC Occupancy; R -:t. "type ofConntruction V -N 50 TSF ROOF U. P.O. Box 505 32(0 E4ierpri .e Ave. Yak, Nebraska 68467 (402) 362-4453 fax i4O2y 362-7724 Wind L.otgds: 25 PSF Wind Pressure; PAnivident to 79 MPH Wind Spred at P.spok ire "C" or 103 MPH Wind Speed at isxposure 'ibis loiter Is to certify tlmt the above hocnc will be designed, constructed & inspccr+d to the design criteria ns specified above. Designs and construction will be st;�ic��cd ntud inspected by the State of Nebraska. Evidence of this will be in the foirn ui a seal cleat b generally located in the living room window of the home and by a et'ttzplirince certificate that is normally located underneath the kitel.ca sink. APPROVED SUlit ACT TO NOTED LICCEPT10 8 & itisP1*CTION$ GARFIELI) COUN . BUILD i G EPARTM rut;i[,I) CO Muret 14N WrttsOWf NON PLANS ONME %ale Of Sincerely, Wayiic Warren Engineering Manager co? Scke-e iqes�defrice }Ury:0r.M:rt�rteo H ES AND HOU31Na crmmute ILs r DELATED COMPOWNI$ 03x7 a e (( c/ c . � JAN;31-p1 WED 08:25 AM CHAMPION HONES M.•. • • r • 10. a• f, co A• tJ' T� 39Vd • 4. i M i• FAX NO, 2 402 362 7724 P. 02 •3 +rwwoo. 2 • ... • /41,407'17.1, 111 •�� . rr•.r.a..w..a..... • r r.. • .. w r i7�:• ��11, 7 rtW 1 Y .Ca . • xxe� M N 'UMW 400/00 J c4',•1'31- vuI 44-4114" of 1"641- % 9 1_` 5 1191 NON xed .31100d IT/ /RgG'FAF Qfi:1LY TRA7/TR/TG FEB -02701 FRI 03:11 PM CHAMPION HOMES J L-11-00 ?U 02:25 PM CHAMP H0IiES FAX NO. 1 402 362 7724 P. 02 FAX NO. ' 102 362 7724 P. 02/02 g•d 91,011 EPS 6L2, OONISf10H a a 00:6S 0003 -TT -TX rye A rc H o n. Pier With 3- "% 8 U t$ 8 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for MANUFACTURED HOMES In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. 1 f 1. Is a site plan included that indicates the distances of the proposed building or addition to property lines, other buildir s, setback easements and utility easements? Yes 2. Does the site plan include the location of the I. S.D. S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties), streams or water courses? ` / Yes V 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 4. Do the plans include a foundation plan indicating the size, location and spacing ofall reinforcing steel in accordancey►�ith the uniform building code or per stamped engineered design? Yes �/ 5. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes ✓ No 6. Will this be the only residential structure on the parcel? Yes ✓ No If no -Explain: 7. Have two() complete sets of construction drawings been submitted with the application? Yes 8. For the placement of a manufactured home, have the following been specified? The size of the unit (min. 20ft. x 20ft.); live roof load (min. 40#); wind design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring? Yes 9. Have you designed or had this plan designed while considering building and other construction code requirements? Yes ✓ No 10. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfiel County Building Department? Yes No 11. Do you understand that approval for design and/or construction changes are required prior to the application of e_ se changes? Yes No 2 12. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School Impact" or "Septic Sy nn" fees_ required, at the time you pick up'your building permit? Yes No 13. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 4:00 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be call in to 384-5003. Yes No 14. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final l inspection g jor to receiving a Certificate of Occupancy and occupancy of the building? Yes ✓ No 15. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? _You can contact the Road & Bridge Department at 625-8601. Yes ✓ No 16. Attached is information for placement of a manufactured home. Please review. If you have any questions, please call this office at 945-8212. 17. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes ✓ No I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. signature (5-5430 Phone: Q45 -1882 (days); Project Name: Project Address: date D5c*-7 Coiti-ea 06f,_ 3 Q45 -)ees Z (evenings) PQ q.5 1 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. Mt is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Perappmh 08/00 4 ftjcriLe 131Qck eh?' !v 1, A * ,e 4-r r -r IF ',lei, 00V /. Ac 6 Steel C_' 6a .7 41, $` ' fio!Q Po i Z3 ? € '',e ),Weld -�`�- )fit �. 8 44?r c 1o,: f1P‘1f f om p/ e i oo +, q t a "AA 711 CAW a °then- AeP00:44. c#by at0G j g X/4" Co»ccteet L►'/i4 2 - y LAtic rX 3" Colic/We /kR hf- E,vvS OALy 1 GARFIELD COUNTY Building and Planning MANUFACTURED HOMES Installment requirements within Garfield County 1. A fuel gas pipeline pressure test is required by the installer and the test is required to be witnessed and approved by the Garfield County building inspector. Test must be a minimum pressure of 10 psi and show no appreciable drop within 15 minutes. A gauge capable of indicating pressures no higher than 60 psi shall be used in the test. 2. All stairs serving the unit on the exterior are to comply with the U.B.C. (Uniform Building Code) Section 1006.3 & 1006.9 for rise, run, handrails and guardrails. 3. All decks and porches which are more than 30 inches above grade are required to have guardrail complying with U.B.C. Section 509.1 & 509.2 with a minimum height of 36 inches. Guardrail shall have intermediate rails or an ornamental patter such that a sphere 4 inches in diameter cannot pass through Sec. 509.3. Grade (Adjacent Ground Elevation) is to be measured at points 5 feet horizontally from the level of the walking surface vertically to finished ground, floor or similar surface. 4. If manufactured home is placed on a basement foundation; the foundation and the basement shall comply with requirements ofthe.U.B.C., U.P.C. or U.M.C. including but not limited to: (a) (b) (c) (d) (e) (f) (8) (h) Installation of smoke detectors in the basement and in the manufactured home. U.B.C. Section 310.9.1.4. Installation of escape or rescue windows. U.B.C. Section 310.4. Providing of light, ventilation and sanitation. U.B.C. Section 1203.2 & 1203.3. Providing of minimum room dimensions. U.B.C. Section 310.6. Protection of insulating materials for flame spread requirements. U.B.C. Section 804. Forming and placing of concrete for foundation and floor slab. U.B.C. Chapter 108.5.2. The inspection of all framing as required under U.B.C. Section 108.5.4. The inspection of all round and/or underground plumbing as required under U.P.C. Section 712.2. 5. L P G (Liquified Petroleum Gas). Appliances burning L.P.G. shall not be installed in a pit, basement or similar location where heavier -than air gases may collect unless such location is provided with S11 approved means for removal of unburned gas. U.M.C. Section 304.6. The policy in Garfield County is as follows: (a) An untrapped drain with a minimum diameter of 4 inches located in the lowest area where heavier-than-air vapors may collect is to run with a continuou$ slope to an exterior area which is not within a depression or recessed below adjacent terrain. (b) The area of termination is to be determined by the building inspector as likely to remain free of standing water, ice and other debris that may prevent the flow and dissipation f unburned gas. (c) The upper inlet and termination of the drains to be provided with protection from the entry of debris or animals which may cause blockage of the drain. This protection is to be approved by the building inspector. 6. A final inspection of the placement, blocking, tie -downs, skirting, grading and compliance with above items is required and approval given by the building department prior to occupancy of the manufactured home or occupancy of the basement. . The Garfield County Zoning Resolution of 1978 with Amendments through December 9, 1997, has been amended to read as follows: 2.02.07 (1) Building - Conventional and manufactured: A building constructed or erected on the lot or building site or a factory and built to meet the "Uniform Building Code" or "National Manufactured Housing Construction and Safety Standards Act of 1974", has a minimum dimension of twenty (20) feet wide and twenty (20) feet long and meets the local building code requirements for wind speed of 80 mph an4lor 15 jb. wind load: anchoring requirements in accordance with installation standards based on the minimum basic wind speeds ininiles per hour specified in the Uniform Building Code: and meets or exceeds the snowload requirements adopted by Garfield County (Garfield County requires unowload of 40# per square foot up to 7.00011. elen and certification foam the factory is required that ties the snowload to the Manufactured Home's Seriaf her), Any building meeting these criteria is defined as a single family dwelling and allowed in any zone district that allows i< single family dwelling. MfgReg01.95 Effective June 7, 1995 *** NOTE: A BUILDING PERMIT WILL NOT BE ISSUED UNTIL WE RECEIVE THE cERrrylcATE 2 GARFIELD COUNTY Building and Planning Department Notice of Clarification The Garfield County Board of Commissioners, on January 22, 1996, Passed by Resolution # 96-05, approved the regulation, that Roof Construction will meet or exceed a 40# Snow Load up to and including 7,000 feet in elevation. A4150# to 8,000 75# to 9,000 100# to 10,000 Pre -manufactured homes are included, and must be certified by the factory, that unit, with serial number of that unit was manufactured to meet the snow load, of the elevation it is to be placed at. Or, certified by a Colorado Registered Engineer. A BUILDING PERMIT WILL NOT BE ISSUED UNTIL WE RECEIVE THE CERTIFICATE. It is the roof of the unit itself that must meet the requirements. A false roof, or "Umbrella" over the unit IS NOT ACCEPTABLE. Don Owens Chief Building Official Garfield County snow 109 8th Street, Suite 303 945-8212/285-7972 Glenwood Springs, Colorado 81601 3 sgvirg ncti "A og 3 w 44: r t lid"oNo r Ft 1'82 I.' et !'Ii 'C 1 � I w • r 144 00 1 1 r r r 1 r 1 I • wimp i 0.WOMM 41.10 I f CD K w M g r « - oc I� y OP 4b ••q' i'i 0 II °IV 7 40 10 ,t► ci40 00 L-olormo;' g ....ao4.. •s to t, II. nWit 114 I �� t14 .41 ei 1 4. �i� fel 11114: e1; 4► .4, -j1 w 10 1, 41 '0 fill `t 1ca: f . Al N aNg Hid N11lrIDW .O -,r cesxe76zSsr7t% ial W 4 416 ID 7G 71'77-C S SS59A 7[ CZ CROSS SECTION 8" CONC. f'c= 3000. #4 0 18." #4 ® 18." 2—#4 top Pressure Treated or Red Woo& psi, Fy= 40000. psi Vert ® CL Horiz and bottom of wall 2 Re -Bars Above and Below All Openings BOND BREAKER Minimum, 4" CONC. SLAB 1/2" X10" Anchor Bolts 6' centers, kn each board, & 1' from ach end GJ A D e P ts) !I 545eMeh r Damproof Below Grade ALTERNATE DIRECTION OF LEGS Drain Pipe to Daylight #4 HORIZ. AS SHOWN • • , • q, 16" Garfield County Basic Foundation Wall Design Same pattern Re -Bar 8' Or 4' Dec. 1,1996 t 711 ta°"°1€ ptA le,rliA •2/ 4HX4h' X 10 XIO bes h ft/ Seri ed C'ohcrieth • 7e chEc >jc(CAL &A RAGA— Setbacks: Sr Snowload; 401 Seiismuic... v�rmd Wind expo" Windload: i r; ,F 1994 Building Code and rear and 10 feet on thq sides tO 7000 feet Frost Depth: 36 inches= -30 inches from finished grade to top of footing (Liveload is snowload-imposed by snow) • _ ► 1 INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR ALL INSPECTIONS -Re'-'-.]:5 u e MANUFACTURED HOME BUILDING PERMIT ARFIELD COUNTY, COLORADO Date Issued:q. •1•••• Zoned Area Permit NoFIN?...7 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with an laws and regulations related to zoning, location, construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with hi the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOMES NULL AND VOID. UseMaiii1UF1.101/AF A Foil Address or Legal Description 03f77 IMORyE L %L[al Owne E, I 0613R5v Contractor al V INSPECTION RECORD Footing 2 -/S-C' (AA Foundation or Blocking 2_20..0, p Rough Plumbing S -g.©, A,'). 1 Gas Piping Electrical Final (by State Inspector) 531-0 l Final 5 -f -O) �.5. Phone 384-5003 APPROVED DateM 0 Septic Final rrn' tP Gee ON Notessn°"3 cad lbs , CEO LM SeR_ial of unit`% OOINf3'74206224 THIS PERMIT IS NOT TRANSFERABLE 109 8th Street County Courthouse Glenwood Springs, CO. DO NOT DESTROY THIS CARD By sR (IF PLACED OUTSIDE, COVER WITH CLEAR PLASTIC)