HomeMy WebLinkAboutApplication-PermitI
Garfield County
Building & Planning Department
108 8th Street, Suite #401 Glenwood Springs, Co. 81601
Office:970-945-8212 Fax: 970-384-3470
Inspection Line: 970·384-5003
Building Permit No.
Parcel No: 2123-362-02-004
Locality:
Job Address: 46147 Hwy 6 & 24 . Q1 WS ----~~--····-··--···--------·~ ....
Use of Building: -···--··--··--·· bedroom addition
___ Gilbert, Bob Owner: --·····--·--
Contractor: Owner -----·--·····--···------···--·-
Fees: Plan Check: 145.11 Septic:
Bldg Permit: 223.25 Other Fees: ---·-·······-
Total Fees: j ____ 368.3~
Clerk:~-Date:
GARFIELD COUNTY BUILDING PERMIT APPLICATION
108 8"' Street, Suite 401, Glenwood Springs, Co 81601
Phone: 970-945-8212/ Fax: 970-384-3470 I Inspection Line: 970-384-5003
www.garfield-countv.com
is available at the assessors office 970-945-9134)
Authority. property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate
with this Application.
Legal Access. A Building cannot be issued without proof of!egal and adequate access to the property for purposes of inspections by the Building Department.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, {2) County !SDS Permit, (3) another permit required for use on the property identified above, e.g. State or
County Highway/ Road Access or a State Wastewater Discharge Pennit.
Void Permit. A Building Pennit becomes null and void if the work authori7..ed is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180
days after commencement. ·
CERTIFICATION
I hereby certify that I have read this Application and that the infonnation contained above is true and correct I understand that the Building Department accepts the Application, along with the plans
and specifications and other data submitted by me or on my behalf (submittals\ based upon my certification as to accuracy.
Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on
the submittals reviewed by the Building Department.
In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions ofany federal, state or local law regulating the work and the Garfield County Building
Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location,
construction or use of the struoture(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law.
I hereby grant permission 1D the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the
Building Official from: (1) requiring the ccrrection of errors in the submittals, if any, discovered after issuance; cr (2) stopping construction cruse of the structure(s) or facility(ies) if such is in violation
of County Regulation(s) or any other applicable law.
Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions
or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without
limitation my architect designer, engineer and! or builder.
I HEREBY ACKNOWLEDGE TIIA T l HAVE READ AND UNDERSTAND lBE NOTICE & ABOVE:
STAFF USE ONLY
Special Conditions:
Adjusted Valuation: Plan Check Fee: Permit Fee: ~ Manu home Fee: MisC Fees:
IZ/5'/G.?!i 145. Jj. 22-:s:-.----.
ISDS Fee: Total Fees: Fees Paid: II Balance Due: BP No & Issue pate: .~ NJ & Issued Date:
368 ~ !45. --2 2 :>. '!;.£ \II ~Lj fX\~bJ
Setbacks: OCC Group: Const Type: Zoning:
25,.. z.>, /01 f<LUD
~DEPT: . PLNGDEPT:
~,r ~~ f{¢~ ~L5--
'APPROVAL 'n E APPROVAL' 'D~ E
The following items are required by Garfield County for a final Inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all IBC and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED,
OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance of a
C.O. for the building identified in the Building Permit.
D TE
VALUATION FEE DETERMINATION
Applicant
Address
Date
Bob Gilbert Subdivision
..:4:..;;6.;:.14:-:7:=:H:..;;wy=67 &-::-:2:-:4-, G"'w=s-----Lot/Block
_,8::_11:.:3::.:12:::0:.::0c::8_~-----'----Contractor
Finished (Livable Area):
Main
Upper
Lower
Other
Total
Basement:
Unfinished
Square Feet
Valuation
Conversion ofUnfinished to Finished
Total Valuation
Garage:
Carport:
Total Valuation
Crawl Space
Total Valuation
Decks/ Patios
Total
Covered
Open
Valuation
Type of Construction:
Occupancy:
Valuation
Total Valuation
168 sq.ft
sq.ft
sq.ft
sq.ft X $74.68
168 sq.ft
Commercial
sq.ftX $41.00
sq.ft X $33.68
sq.ft X $18.00
sq.ft X $12.00
sq.ft X $9.00
sq.ft X $24.00
sq.ft X $12.00
sf X
sf X
sf X
sf X
sf X
sf X
Riverview
Lot 4, Block 2
Owner
12,546.24
0.00
0.00
0.00
0.00
0.00
12,546.24
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan and
it's discovered that required information has not been provided by the applicant, this will result in the
delay of the permit issuance and in proceeding with building construction. The owner or contractor shall
be required to provide this information before the plan review can proceed. Other plans that are .in line
for review may be given attention before the new information may be reviewed after it has been
provided to the Building Department.
TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE
SUBMITTEDFOR ALL APPLICATIONS.
Please review this document to determine if you have enough information to design your project
and provide adequate information to facilitate a plan review. Also, please consider using a design
professional for assistance in your design and a construction professional for construction of your
project. Any project with more than ten (10) occupants requires the plans to be sealed by a
Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building, plumbing
and mechanical codes, applicants are requested to review the following checklist prior to and during
design. Applicants are required to indicate appropriately and to submit the completed checklist at
time of application for a permit.
Plans to he included for a Building Permit, must be on drafting paper at least 18"x24" and drawn
to scale.
1
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks,
balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and
original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house-rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed,
wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or your
plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
1. Is a site plan included that identifies the location of the proposed structure or addition and distances to
the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor
and has the surveyors signature and professional stamp on the drawing? Properties with slopes of
30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the
placement of any portion of a structure within 50 ft. of a property line and not within a previously
surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor
and have the surveyor's signature and professional stamp on the drawing. Any structure to be
built within a building envelope of a Jot shown on a recorded subdivision plat shall include a
copy of~e ilding envelope as it is shown on the final plat with the proposed structure located
within the nvelope.
Yes_-=---
2. Does the site plan also include any other buildings on the property, setback easements and utility
easements? !'lease refer to Section 5.05.03 in the (Jarfield County Zoning Resolution if the
property yo(are applying for a building permit on is located on a comer Jot. Special setbacks do
apply . ./
Yes. ____ _
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal
System) and the distances to the property lines, wells (on subject property and adjacent
properties), streams or water courses?
Yes _ __,_!-+=-
4. Does the site plan indicate the location and direction of the County or private road accessing the
property? /"-·
Yes f'l """
2
5. Are you aware that prior to submittal of a building permit application you are required to show proof
of a legal and adequate access to the site? This may include (but is not limited to) proof of your
right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept.
of Highway Permit, including a Notice to Proceed; a permit from the federal government or any
combination. You can contact the Road & Bridge Department at 625-8601. See phone book for
~~;rant~
6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel
in accordj)Jlce with the IRC or per stamped engineered design?
Yes_x!L_ ___ _
7. Do the plans i~dic the location and size of ventilation openings for under floor crawl spaces and the
clearances quired between wood and earth?
Yes No ____ _
8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and
soffits? j··
Yes No'l\_j?
I
9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of
40 pounds per y{uare foot up to & including 7,000 feet above sea level), floor loads and wind
loads? ~
Yes. _____ _
10. Does the plan~·ncl de a building section drawing indicating foundation, wall, floor, and roof
construction?
Yes __ -=---
11. Does the buil~i~:V'ec:tion drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafter,/!'" JOists or trusses?
Yes _____ _
12. Does the building sect', n drawing or other detail include the method of positive connection of all
columns and be s?
Yes ___ --"'----
13. Does the elevation plan indicate the height of the building or proposed addition from the
undistu~be 'grade to the midpoint between the ridge and eave of a gable or shed roof or the top
of a flat ro f? (Building height measurement usually not to exceed 25 feet)
Yes_-"-----
14. Does the plan include any stove or zero clearance fireplace planned for installation including make
and model and Colorado Phase)'{ certifications or phase II EPA certification?
Yes No V' -
3
15. Does the plan include a masonryJreplace including a fireplace section indicating design to comply
with the IRC?
Yes No __ ~~-----
16. Does the plan include a window schedule or other verification that egress/rescue windows from
sleepin. g rJoms and/or basements comply with the requirements of the IRC?
Yes~_y_:y_ __ _
17. Does the plan include a window schedule or other verification that windows provide natural light and
ventilation for all habitable rooms?
Yes __ _:_v __ _
18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing
immediately adj cent to such doors; glazing adjacent to any surface normally used as a walking
surface; slidin lass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing fort se areas?
Yes No. _______ _
19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on
theplan? A
Yes 1'\
20. Do you understa d that if you are building on a parcel of land created by the exemption process or the
subdivisio recess, are building plans in compliance with all plat notes and/or covenants?
Yes_-"'----
21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to
obtain written permission from the association, if required by that association, prior to submitting
an application for a building permit? The building permit application will be accepted without
it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in
revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans
have bee~rev' wed by the Building Department prior to any action by the HOA that requires either
revocation substantial modification of the plans.
Yes · ' ·
y residential structure on the parcel?
· Yes ___ ___,f--No If no-Explain: ______ _
23. Have two (2) co plete sets of construction drawings been submitted with the application?
Yes _ __,,__ __
24. Do you un~d that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long?
Yes ____ _
4
25. Have you desi ed or had this plan designed while considering building and other construction code
s?
26. Do your plans com .ly with all zoning rules and regulations in the County related to your properties
zone district?
Yes __ ---1"'--------
27. Does the plan accur ely indicate what you intend to construct and what will receive a fmal inspection
by the Garfiel County Building Department?
Yes __ _c_ __
'
28. Do you und;trrs nd that approval for design and/or construction changes are required prior to the
application fthese changes?
Yes ---'----
29. Do you understan that the Building Department will collect a "Plan Review" fee from you at the
time of appli tion submittal and that you will be required to pay the "Permit Fee" as well as any
"Road Imp t" or "Septic System" fees required, at the time you pick up your building permit?
Yes _ __,"---
30. Are you aware that you must call in for an inspection by 3:30 the business day before the
requested ~·nsp 'ction in order to receive it the following business day? Inspections will be
. made from 7· 0 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in
to 384-5003.
Yes No ________ __
31. Are you aware tha requesting inspections on work that is not ready or not accessible will result in a
$50.00 re-ins ection fee?
Yes ___ ~-----
32. Are you awa1e t at you are required to call for all inspections required under the IRC including
approval on final inspection prior to receiving a Certificate of Occupancy and occupancy of the
building?
Yes ______ _
33. Are you aware ttfat he Permit Application must be signed by the Owner or a written authority being
given for an ent and that the party responsible for the project must comply with the IRC?
Yes __ ~L----
5
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and
Plumber to perform it !lations and hookups, unless you as the homeowner are performing the
work? The licens number of the person performing the work will be required at time of
applicable inspec · n.
Yes ____ :_ ___ _
35. Are you aware, th on the front of the Building Permit Application you will need to fill in the
Parcel/Schedul Number for the lot you are applying for this permit on prior to submittal of a
building pe · application? Your attention in this is appreciated.
Yes __ -"'-----
36. Do you know th7t t local fire district may require you to submit plans for their review of fire safety
issues?
Yes (please check with the building department about this requirement)
37. Do you understoithat if you are planning on doing any excavating or grading to the property prior
to issuan~f: building permit that you will be required to obtain a grading permit?
Yes ____ _
38. Are you aware that · ·you will be connecting to a public water and/or sewer system, that the tap fees
have to be pai and the connections inspected by the service provider prior to the issuance of a
Certificate o ccupancy?
Yes ____ _
I hereby acknowledge that I have read, understand and answered these questions to the best of
my ability.
Phone:3P"'::> 444 6£f3tt (days);
Project Name: CQ ~~ {2£:<:; IOBNij?;
Project Address: l\.614) 1---\w"( ~ ~ d-lj
6
__________ (evenings)
<4 \ ~Ci"-> wr:.XY:J ..:seo1 l\ r;-s eo
f)\(;0\
Notes:
If any required information is missing delays in issuing the permit are to be expected. Work may not
proceed without the issuance of a permit. If it is determined by the Building Official that additional
information is necessary to review the application and plans to determine minimum compliance with the
adopted codes, the application may be placed behind more recent applications for building permits in the
review process and not reviewed until required information has been provided and the application rotates
again to first position for review, delay in issuance of the permit or delay in proceeding with
construction.
BpminreqDec2007
7
GARFIELD COUNTY
BUILDING REQUIREMENTS
Codes: 2003 JRC, IBC, IFGC, ll\1C, IPC,
Setbacks: Check subdivisions and zone district for setback requirements.
Snowload (measured at the roof): 40PSF up to 7000ft. elevation.
Seismic design category: B
SOP SF 7001 to 8000ft.
7 5PSF 8001 to 9000ft.
lOOP SF 9001 to 1 OOOOft.
Weathering probability for concrete: Severe
Termite infestation probability: None to slight
Wind speed: 90mph
Decay probability: None to slight
Wind Exposure: B or C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above.
Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft.
elevation.
Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by
Building Official.
Ice shield under-layment required.
Mean Annual temp.: Variable
Insulation: Maximum glazing U factor: 0.50
Minimum R-Values:
•
•
•
Ceilings/roofs R values are: R-30 stick built
structures. R-38 log construction and steel
rafter construction.
Walls R values are R-19 wood frame; R-19
cavity R-3 sheathing steel studs.
Floors R-values are R-19 .
•
•
•
Basement wall R-values are R-10 beTow
grade, R -19 above grade.
Slab perimeter R-value and depth is R-
10/36in.
Crawl space wall R-values are R-10 below
grade and R -19 above grade
If floors over crawl spaces are not insulated, the crawl space walls must be
insulated. Basement wall must be insulated to frost depth. Common walls
garage to house must have R -19 insulation. Common ceiling/floor garage
to house must have R-19. Take precautions to protect plumbing in these
areas.
No.~--------~11_1~3~4 __ __ Assessor's Parcel No. 2123-362-02-004
Date 1 0/13/2008
BUILDING PERMIT CARD
Job Address __ ...::.46:::...1:....:4:.:.7....:H;:.:wy::.L_6=-=&~2:..:4.!._, G=W.:..:.::S:....__ ____ ..,...-_________________ _
Owner _____ G.:.:..i:.:..:lb:....:e:..:..rt="-'-=B...::.o.:.:..b _______ Address 46147 Hwy 6 & 24, GWS Phone # 970-928-9057
Contractor ____ O_w_n_e_r ____ ~----Address __ s_am_e _______ Phone # 303-944-0232
Setbacks: Front _____ Rear _______ RH ______ LH _____ Zoning ____ _
bedroom addition
Soils Test ----f;-1':-;.-----,--.----,=-----
Footing 04-fle,...,f ~
Foundation 5~/e?jf,
Grout ____________ ___
U n derg ro u n d PI u m b i ng ---:::-:::--:--:;;--;....,-;;--;;--
Roug.h P}'li!~ing. 3A~-P ~ Fram1ngt!f!J._/~ ~~,p.f....f2rt1
Insulation ;.-g1.1: 0'1.
Roofing--,--:=-,:;:;----:::---------
Drywall 65--t??~
Gas Piping __________ _
INSPECTIONS
NOTES
Weatherproofing ___________ __
Mechanical --4.
Electrical Rough (State) 6'=-:z-: tYl . hf.:..~~
Electr al Final (State) '!..:.·If ... tJ 9 ~
Final • ·O /Checklist Completed?_...,=...:..;:::==
Certificate Occupancy # ---------Date _____________ _
Septic System # ___________ __
Date ----------------Final _____________ _
Other __________________ _
(continue on back)
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
INSPECTION WILL NOT BE MADE UNlESS
THIS CARD IS POSTED ON THE JOB
Date Issued_____,_( 0-"--• \.._..3"-·--0._,~"'----Permit No. ---e:I-"'-I..._.I?Lf"---t'-----
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations
related to the zoning, location; construction and erection of the proposed structured for which this permit is
granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location,
erection and construction of the above described structure, the permit may then be revoked by notice from the
County Building department and IMMEDIATELY BECOME NULL AND VOID.
UseJJe.d.rooM addi+fM,_. ______ _
Address or Legal Description l:lio 1¢1 1:-tw~ ll""" 2'-1 (;) W ~
Owner -El\ \ bfri~.._b"--__ Contractor _Q_wtle%'""'"------
BuildingPermitType IZ.eSI d~O\.
This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection
INSPECTION RECORD
Footing Driveway
Fo~~t~~~~ S--v~1 -~ Insulation
S-J.1-D'1 fJM__
Underground Plumbing Drywall
6~(-0'? ~
Rough Plumbing Electric;;! klat;(;~T) '5 -u~o~ ~ (Prior to Final)
Rough Mechanical Septic Final
Gas Piping FINAL 9.1-f~/JN\
Electric Rough (by Slate Inspector)
e~ ;rr 6/tz--(of (You Must Call For Final Inspection)
(Prior to Framillg) Notes
Framing Dk.~~ ~ L:e\\<..-j;'. 2-241 ~
(to include Roof in place & Windows & Doors installed & Fires topping in place)
APPROVED
Date
THIS PERMIT IS NOT TRANSFERABLE
For Inspection Call970·384·5003 Office 970-945-8212
108 8th Street, Suite 401 Glenwood Springs, Colorado 81601
DO NOT DESTROY THIS CARD
\ o. c; ·ot;:» By F.Jm:wn lhh.a..~~~e
PROTECT PERMIT FROM WEATHER DA~~~
(DO NOT LAMINATE)
COUNTY Of GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at __{_JI/?"'-'I-l.i_rc___M--'---'tJ~¥_:::.0'-"-A--=CJ:_______c_1 __ _
Permit No. _ _L/1~/.3=-{_L_ ________ _
I have this day inspected this structure and these
premises and found the following corrections needed:
~all for Re-lnspection
0 $50.00 Re-lnspection Fee must be pa1d pnor to Re-lnspect1on
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date m¥ Zf . 7e1t
Building Inspector ~4
I
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at Y.<;f2 ~ c(i",;;.f
Permit No. --'-!-'-/_,_(!d.3-f-------------
I have this day inspected this structure and these
premises and found the following corrections needed:
}(call for Re-lnspection
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date !/-;;<-c/O' · 20
Building !~spector ~~:::?· ---;;=="'-
Phone (970) 945-8212
.h.U. DWEllliilGS SHALl HAVE:
1. SMOKE DET #31 AND EGRESS#28JISSJROOII
2. BATHROOM VENTED f/.56
3. POS. DRAINAGE AWAY FROM fiiiJJIS8
4. ADDRESS POSTED 111 ;!;;
5. DRYER VBm!DfiS . 0+i .
APPROVED
_;>~
~
~·.····
......-
foubdd•oD f>li'l'\.
l . f'l) . ' :: -.
.. \{) -~ 1 ..
''-'"'\. i: ...,.
1'1\
/
/
/
//
/
/
/
' .
/ ,'
/
~
"-
(I
3
3
1.\.1
' I
' ' l I
..0
'-, ';)
1
\..-
~ ·.~~
"'
~,~----~/
~
0
®
I .
< 1 . I I '
' I
/
/
/
.. ···
..... -.··. -.-., ... -.----__ ;-::_'"'~ 7:'".'7"."~
\
..
I \ '
I \ ;r
\ \\. :;,
\ 1 li
I
\
,.
\ \!
'---1-
I !
I
I r~ (
i
I ! ' i i
i
_.,., __ L...
I I
I
I
n I ~------
/'
·~-" '" ---..... . -·----_ __:;;;
/
\
\
c
Q
+ <01::
},
~
~
7
f
/' ,..·
'\ I . ' ~~~ \ : ~~ ' l JL.,....i. l,cc-· · ·cc,icc.-c ... ::::::-:::::::::1
.,
~
\
.:i
'
'f ___ J
I
\
I
··'
.. r-
"" "" ,,.,!
~
\
-I
Parcel Detail Page I of4
Garfield County Assessor/Treasurer
Parcel Detail Information
Assessor/Ireasurexl:nmerty Search I Assessor SubsetQuery: I As~essor SaLesJ3earch
Cle;:k_& Recorde.r_Reception_Search
Pan;el Detail I Value_.Detail I S<!les_Deta,i! I Residential/Comrnenial Improve_ment Detail
Land.De.tail I ):'hotogrnp_h.s I Mill Leyy Revenue.s Detail
I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I
I 004 II R040015 II 212336202004 II 60.519 I
\(_t \Af)
Owner Name and Mailing Address
jGILBERT, ROBERT E., JR. & ANGIA N. (JT)
j46147 HIGHWAY 6 & 24
jGLENWOOD SPRINGS, CO 81601
Assessor's Parcel Description
(Not to be used as a legal description)
jSECT,TWN,RNG:36-5-90 SUB:RlVERVIEW
jSUB. BLK:2 LOT:4 BK:0445 PG:Oll9
jBK: 1092 PG:0831 BK:0783 PG:0346
jBK:0709 PG:0483 BK:0709 PG:0478
Location
I
I
I
I
I
I
I
Physical 146147 HIGHWAY 6 & 24 GLENWOOD SPRINGS I Address:
I Subdivision: jjRlVERVIEW SUB. I
I Land Acres: I 0.38
I Land Sq Ft: I 0
I Section II Township II Range I
I 36 II 5 II 90 I
2008 Property Tax Valuation Information
http://www.garcoact.com/assessor/Parcel.asp? AccountNumber=R0400 15 7/17/2008
Parcel Detail Page 2 of4
II Actual Value II Assessed Value I
I Land: II 86,oooll 6,8501
I Improvements: II 272,71011 21,7101
I Total: II 358,71011 28,5601
Additional Value Detllil
Most Recent Sale
Sale Date: 1110/12/1998
Sale Price: 11203,000
Basic Building Characteristics
Number of Residential 1 Buildings:
Number of Comm/Ind 0 Buildings:
Residential Building Occurrence 1 Characteristics I
FINISHED BSMT: 111,232
1 STORY WI BASEMENT: 111,232
FIN. 1 STORY OVERII486
GARAGE:
1 STORY: 11189
TOTAL HEATED AREA: 113,139 I
ABSTRACT CODE·IISINGLE F AM.RES-• IMPROVEMTS I
ARCHITECTURAL STYLE: lim LEVEL
EXTERIOR WALL: IIBOARD/BATT
ROOF COVER: llcOMP SHNGL
ROOF STRUCTURE: IIGABLE
INTERIOR WALL: IIDRYWALL
FLOOR: IICARPET I
FLOOR: llsHT VINYL I
HEATING FUEL: IlGAS I
HEATING TYPE: IIFORCED AIR I
I STORIES: llsTORIES 1.0 I
http:/ /www.garcoact.com/assessor/Parcel.asp? AccountNumber=R0400 15 7/17/2008
Parcel Detail Page 3 of4
I BATHS: 12
I ROOMS: 17
I UNITS: II
I BEDROOMS: 14
I YEAR BUILT: 111974 I
Tax Information
.
I Tax Year II Transaction Tyl!e II Amount I
I 2007 II Tax Payment: Second Half II ($864.2211
I 2007 II Tax Payment: First Half II ($864.2211
2007 II Tax Amount II $1,728.441
2006 II Tax Payment: Second Half II ($776.7021
2006 II Tax Payment: First Half II ($776.7011
2006 II Tax Amount II $1,553.401
I 2005 II Tax Payment: Second Half II ($777.0011
I 2005 II Tax Payment: First Half II ($777.0021
I 2005 II Tax Amount II $1,554.001
2004 II Tax Payment: Second Half II ($908.3911
2004 II Tax Payment: First Half II ($908.39)1
2004 II Tax Amount II $1,816.781
2003 II Tax Payment: Second Half II ($663.0721
2003 II Tax Payment: First Half II ($663.o72l
2003 II Tax Amount II $1,326.141
2002 II Tax Payment: Second Half II ($665.5211
2002 II Tax Payment: First Half II ($665.5211
2002 II Tax Amount II $1,331.041
2001 II Tax Payment: Second Half II ($669.7921
2001 II Tax Payment: First Half II ($669.79)1
2001 II Tax Amount II $1,339.581
2000 II Tax Payment: Second Half II ($675.68)1
2000 II Tax Payment: First Half II ($675.6811
2000 II Tax Amount II $1,351.361
1999 II Tax Payment: Second Half II ($623.0011
1999 II Tax Payment: First Half II ($623.00)1
1999 II Tax Amount II $1,246.ool
http://www.garcoact.com/assessor/Parcel.asp?AccountNumber=R040015 7/17/2008