HomeMy WebLinkAboutOWTS Design Plans..
N
~
I 1-1
O' 25' 50'
Scale: 1" = 50'-0"
DESIGN
4-BEDROOM RESIDENCE
75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOMS+ 75
GAL (4th BEDROOM)= WASTEWATER FLOW= 525 GAL/DAY
TANK:
4-BEDOORMS REQUIRES MIN. 1250-GALLON SEPTIC TANK
SOIL TREATMENT AREA (STA):
LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAL/ SQ FT
CALCULATED STA= Q/LTAR = 525 / 0.6 = 875 SF
GRAVITY, TRENCHES= 875 SF X 1.0 = 875 SF
CHAMBERS= 875 SF X 0.7 = 612.5 SF/ 12 SF I CHAMBER =51
CHAMBERS
FOUR GRAVELLESS CHAMBER TRENCHES
13 'QUICK 4' CHAMBERS IN EACH TRENCH
TOTAL 52 'QUICK 4' CHAMBERS
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LEITER DATED 02/28/16
ALL . 1rn1m1 ~, 1 ~
33 Four Wheel Drive Road
Carbondale, Colorado 81623
Phone 970.309.5259
carla@allserviceseptic.com
I • ,, L
~
.,,,..q0'-!4'
!ti(. .\.IAi'JOKJl;Jl;AN
J OX ,161
JIONllAU:.. CO Alh2l
"""'
l)OO'lAvtr.rnt
(l'f'rl'l.a1J
4-BEDROOM ---.
RESIDENCE
\$U:ll•U.,..&,~1
(~
I
I
I
I
I
"'--...---
Little Residence
Lot 51 Panorama Ranch
TBD Determined Elk Range Road
Garfield County, Colorado
Project Number. C1195
---
~-
l.lrv1U1R•
--
.,.
(i) SITE PLAN ·' u• ~·
Date: 02 /28/16
Designed By: CBO
Reviewed By: RHP
Drawn By: ANG
W1.0
Sheet 1 of 3
~·
~
I 1-j
O' 10' 20'
Scale: 1" = 20'-0"
ALL .. ~Hlml 9
~ ~<'eo
""
CHAMBER TRENCH STA.
4 ROWS OF 13 CHAMBERS
= 52 CHAMBERS = 624 SF
OF INFILTRATIVE AREA
INSPECTION PORTS AT
BEGINNING AND END OF
EACH TRENCH~~~-
33 Four Wheel Drive Road
Carbondale, Colorado 81623
Phone 970.309.5259
carla@allserviceseptic.com
STONE VENEER
SEAT WALL
NOTE:
TRENCHES TO FOLLOW
TOPOGRAPHIC CONTOURS
-------
--..._
j / \:d I 4" DIA SDR-35 SEWER LINE
WITH DOUBLE-SWEEP
7 CLEAN OUT
(MIN. 2% SLOPE TO TANK) ------------..._..._
~ NEW 1250-GALLON,
TWO-COMPARTME_NT
CONCRETE SEPTIC TANK
WITH EFFLUENT SCREEN
DISTRIBUTION BOX
ACCESSIBLE AT GRADE
4" DIA SDR-35 SEWER LINE TO
D-BOX
(MIN 1 % SLPOE TO TRENCH
(jl PROPOSED OWT~. P-~~~
Little Residence
Lot 51 Panorama Ranch
TBD Determined Elk Range Road
Garfield County, Colorado
Project Number. C1195
-------
~4" DIA SDR-35 SEWER LINE
TOD-BOX
(MIN 1 % SLPOE TO D-BOX)
Date: 02/28116
Designed By: CBO
Reviewed By: RHP
Drawn By: ANG
-
W2.0
Sheet2 of 3
6'min
.---u--GRAVELLESS 'Q UICK-4'
CHAMBER (4' x 3'j
PIPES PLACED I
TOP PORT OF '
CHAMBER END
PLATES
4 • DIA SDR-35 SEWER
LINE LINE FROM i1 ANK
\. \_ACCESS AT GRADE
>--''!"-----------52'-----------_, ~DISTRIBUTION BOX WITH
• DIA SDR-35 SEWER LINE
(MIN 1% SLOPE TO TRENCH) 13 CHAMBERS PER TRENCH
INSPECTION PORT AT
BEGINNING ANO END OF
EACH TRENCH
(i) ST A PLAN 1101 TO ,_ '
SLIP-ON PVC CAP-
DO NOT GLUE
INSULATED COPPER
TRACER WIRE
4" DIA SDR-35---......,
SEWER LINE
TO TANK TO HOUSE
0) CLEANOUT DET!lh0 sc.ou:
9_~!• 33 Four Wheel Drive Road
Carbondale, Colorado 81623
Phone 970.309.5259
·~-_...,_
BOX AND COVER BROUGHT TO GRADE l
CONCRETE LID~
FINSHEO GRADE
0000
OUTLETS
DISTRIBUTION BOX
(4) D-BOX DETAIL
BAFFLE OR
ANGLED PIPE
TO BE USED
AT INLET
NOT TO SCAL£
Little Residence
Lot 51 Panorama Ranch
TBD Determined Elk Range Road
Garfield County, Colorado
Project Number: C 1195
r-.=
4 .0' max
L IK' .,
LIMIT OF
EXCAVATION
GRAVELLESS 'QUICK-4'
CHAMBER (4' x 3')
(2) STA SECTION HOT to S&li
SLIP-ON PVC CAP
DO NOT GLUE
4" DIA SOR-35---..
INSPECTION PIPE
STAFILTER~j ~
MEDIA
SPRINKLER VAL VE
BOX AT GRADE
FINISHED GRADE .,..._
1 /4 H DIA HOLE DRILLED
INTO TWO SIDES OF PIPE
FOR VENTILATION
(BELOW SLIP ON CAP)
(s) INSPECTION PORT .~f.~~~~-
Date : 02/28/16
Designed By: CBO
Reviewed By: RHP
Drawn By: ANG
W3.0
Sheet 3 of 3