Subject: State of Colo. -Inspection Rpt • Permit --768396
From:
To:
Date:
dora_elecandplumbing_eupdates@state .co .us (dora_elecandplumbing_eupdates@stateco .us)
acetowing007@yahoo.com:
Monday, July 18, 2016 1 :13 PM
COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, CO. 80202
Page 1 of 4
Inspection Report
Permit#: 768396 Date Inspected: 21 -0CT-15
Permit Holder: GARY WALLACE
GARY WALLACE
Site:
Owner:
Status:
Inspection
Type:
Inspector:
Corrections:
Comments:
1065 GAGE RD RIFLE CO 81650
Phone: (970) 379-0526 Fax: (970) 625-0522
Email: PATIYWACK56@YAHOO.COM
1065 GAGE RD Rifle Garfield
GARY WALLACE
REJECTED
Rough In Part ial : N Trim : N
New Residential
Norman Feck 303-869-3442
Fee Pending · N Hazard N
Remove drywall and insulation as discussed. Junction box make-up must be
visible for inspection.
No inspections to date and project has finished surfaces.
COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, CO . 80202
Inspection Report
http s://us-mg5 .mai l.y ahoo .com/neo/launch?.rand=27mpt3n26bv09 7/19/2016
Print
Permit#:
Permit
Holder:
Site:
Owner:
Status:
Inspection
Type:
Inspector:
Corrections:
Comments:
Permit#:
Permit
Holder:
Site:
Owner:
Status:
768396
GARY WALLACE
GARY WALLACE
1065 GAGE RD RIFLE CO 81650
Phone: (970) 379-0526
Email: PATIYWACK56@YAHOO.COM
1065 GAGE RD Rifle Garfield
GARY WALLACE
PARTIAL
Rough In Partial : N Trim: N
New Residential
Norman Feck 303-869-3442
Page 2of4
Date Inspected: 14-DEC-15
Fax: (970) 625-0522
Fee Pending N Hazard: N
1) House walls and ceilings ok other than stair rail floor boxes and outdoor
front/back receptacles yet to be installed. 2) Shop with loft and service will be a
separate permit.
COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, CO. 80202
768396
GARY WALLACE
GARY WALLACE
1065 GAGE RD RIFLE CO 81650
Phone: (970) 379-0526
Email: PATTYWACK56@YAHOO .COM
1065 GAGE RD Rifle Garfield
GARY WALLACE
ACCEPTED
Inspection Report
Date Inspected: 01-APR-16
Fax: (970) 625-0522
https ://us -mg5 .mail .yahoo.com/neo/launch?.rand=27mpt3n26bv09 7/19/2016
Print Page 3 of 4
Inspection Rough In
Type:
Partial ' N Trim : N Fee Pending . N Hazard N
New Residential
Inspector: Norman Feck 303-869-3442
1) 300.4G Bushing required on all raceways containing # 4 or larger conductors. 2)
352.30 PVC under service panel to be securely fastened within 3' of service
enclosure. 3) 250.24A1 Grounding electrode conductor must land in new all-in-one
. • service. Presently terminate in indoor previous service panel (now a feeder panel).
Corrections. 4) 250.24A5 Grounded conductor shall not terminate to any part of the grounding
system after the service. Separate neutrals from bare or green ground wires in
indoor house panel (now a feeder panel). Also, remove green main bonding
jumper screw from indoor house panel.
Comments:
Permit#:
Complete Rough Inspection 1) Meter release for new service ok 2) UG to shop with
loft ok 3) Shop with loft branch circuit wiring will be on a separate permit 4) Yet to
do to close this permit: Do correction items of this report, land feeders from
service to house panel, and land feeders for service to shop with loft building.
COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, CO. 80202
Inspection Report
768396 Date Inspected: 11-APR-16
Permit Holder: GARY WALLACE
Site:
Owner:
Status:
Inspection Type:
Inspector:
Corrections:
Comments:
GARY WALLACE
1065 GAGE RD RIFLE CO 81650
Phone: (970) 379-0526 Fax: (970) 625-0522
Email: PATIYWACK56@YAHOO.COM
1065 GAGE RD Rifle Garfield
GARY WALLACE
ACCEPTED
Final Partial : N Trim : N
New Residential
Norman Feck 303-869-3442
Meter release ok
Fee Pending. N Hazard : N
https://us-mg5 .mail.yahoo.com/neo/launch?.rand2 27mpt3n26bv09 7/19/2016