Loading...
HomeMy WebLinkAboutElectrical Permit InfoPrint Subject: State of Colo. -Inspection Rpt • Permit --768396 From: To: Date: dora_elecandplumbing_eupdates@state .co .us (dora_elecandplumbing_eupdates@stateco .us) acetowing007@yahoo.com: Monday, July 18, 2016 1 :13 PM COLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Denver, CO. 80202 Page 1 of 4 Inspection Report Permit#: 768396 Date Inspected: 21 -0CT-15 Permit Holder: GARY WALLACE GARY WALLACE Site: Owner: Status: Inspection Type: Inspector: Corrections: Comments: 1065 GAGE RD RIFLE CO 81650 Phone: (970) 379-0526 Fax: (970) 625-0522 Email: PATIYWACK56@YAHOO.COM 1065 GAGE RD Rifle Garfield GARY WALLACE REJECTED Rough In Part ial : N Trim : N New Residential Norman Feck 303-869-3442 Fee Pending · N Hazard N Remove drywall and insulation as discussed. Junction box make-up must be visible for inspection. No inspections to date and project has finished surfaces. COLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Denver, CO . 80202 Inspection Report http s://us-mg5 .mai l.y ahoo .com/neo/launch?.rand=27mpt3n26bv09 7/19/2016 Print Permit#: Permit Holder: Site: Owner: Status: Inspection Type: Inspector: Corrections: Comments: Permit#: Permit Holder: Site: Owner: Status: 768396 GARY WALLACE GARY WALLACE 1065 GAGE RD RIFLE CO 81650 Phone: (970) 379-0526 Email: PATIYWACK56@YAHOO.COM 1065 GAGE RD Rifle Garfield GARY WALLACE PARTIAL Rough In Partial : N Trim: N New Residential Norman Feck 303-869-3442 Page 2of4 Date Inspected: 14-DEC-15 Fax: (970) 625-0522 Fee Pending N Hazard: N 1) House walls and ceilings ok other than stair rail floor boxes and outdoor front/back receptacles yet to be installed. 2) Shop with loft and service will be a separate permit. COLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Denver, CO. 80202 768396 GARY WALLACE GARY WALLACE 1065 GAGE RD RIFLE CO 81650 Phone: (970) 379-0526 Email: PATTYWACK56@YAHOO .COM 1065 GAGE RD Rifle Garfield GARY WALLACE ACCEPTED Inspection Report Date Inspected: 01-APR-16 Fax: (970) 625-0522 https ://us -mg5 .mail .yahoo.com/neo/launch?.rand=27mpt3n26bv09 7/19/2016 Print Page 3 of 4 Inspection Rough In Type: Partial ' N Trim : N Fee Pending . N Hazard N New Residential Inspector: Norman Feck 303-869-3442 1) 300.4G Bushing required on all raceways containing # 4 or larger conductors. 2) 352.30 PVC under service panel to be securely fastened within 3' of service enclosure. 3) 250.24A1 Grounding electrode conductor must land in new all-in-one . • service. Presently terminate in indoor previous service panel (now a feeder panel). Corrections. 4) 250.24A5 Grounded conductor shall not terminate to any part of the grounding system after the service. Separate neutrals from bare or green ground wires in indoor house panel (now a feeder panel). Also, remove green main bonding jumper screw from indoor house panel. Comments: Permit#: Complete Rough Inspection 1) Meter release for new service ok 2) UG to shop with loft ok 3) Shop with loft branch circuit wiring will be on a separate permit 4) Yet to do to close this permit: Do correction items of this report, land feeders from service to house panel, and land feeders for service to shop with loft building. COLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Denver, CO. 80202 Inspection Report 768396 Date Inspected: 11-APR-16 Permit Holder: GARY WALLACE Site: Owner: Status: Inspection Type: Inspector: Corrections: Comments: GARY WALLACE 1065 GAGE RD RIFLE CO 81650 Phone: (970) 379-0526 Fax: (970) 625-0522 Email: PATIYWACK56@YAHOO.COM 1065 GAGE RD Rifle Garfield GARY WALLACE ACCEPTED Final Partial : N Trim : N New Residential Norman Feck 303-869-3442 Meter release ok Fee Pending. N Hazard : N https://us-mg5 .mail.yahoo.com/neo/launch?.rand2 27mpt3n26bv09 7/19/2016