Date: 5-24-16
Inspection Report
Project: Metal Building M.R.1./IRMW II LLC
Address: 1058 County Rd. 100 Carbondale, CO
Building Permit No: BLC0-03-16-4116
General Contractor: Tally Ho Construction
Inspection of shop fabrication or field work at job site: Field
Report#!
Page I of l
Report: Inspected high strength A325 bolting at the steel frame column, rafter,
and portal frame connections. Also randomly tested/verified A325 bolts were
adequately tightened.
The high strength bolting inspected above appeared to be in substantial
conformance with the plans, and the AISC/RCSC Specification for A325/ A490
bolting.
Note; the Mezzanine level steel framing that was not yet installed & would need
to be inspected at a later date.
9706258636 TALLY HO CONSTRUCTION 08.41 :33a.m 06-24-2016
West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO 81504
Phone:970-434-6988
Cell: 970-260-2844
· Final Inspection Report
Date: 6-14-16
Project: Metal Building M.RI.IIRMW II LLC
Address: 1058 County Rd. 100 Carbondale, CO
Building Permit No: BLC0-03-16-4116
General Contractor: Tally Ho Construction
Inspection of shop fabrication or field work at job site: Field
Report#2
Page 1of1
Report: Inspected high strength A325 bolting at the mezzanine support beam
connections & at one column connection partition wall. Also randomly
tested/verified A325 bolts were adequately tightened.
The high strength bolting inspected above appeared to be in substantial
conformance with the plans, and the AISC/RCSC Specification for A325/A490
bolting.
To the best of my knowledge this completes the special inspections of the high
strength A325 bolting, as outlined in reports #1 & #2 for the project
212
9706258636 TALLY HO CONSTRUCTION
West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO 81504
Phone:970-434-6988
Cell: 970-260-2844
Date: 5-24-16
Inspection Report
Project: Metal Building M.R.I./IRMW Il LLC
Address: 1058 County Rd. 100 Carbondale, CO
Building Permit No: BLC0-03-16-4116
General Contractor: Tally Ho Construction
06 :35 :45a.m . 06-06-2016
Report#l
Page 1 of I
Inspection of shop fabrication or field work at job site: Field
Report: Inspected high strength A325 bolting at the steel frame column, rafter,
and portal frame connections. Also randomly tested/verified A325 bolts were
adequately tightened.
The high strength bolting inspected above appeared to be in substantial
conformance with the plans, and the AISC/RCSC Specification for A325/ A490
bolting.
Note; the Mezzanine level steel framing that was not yet installed & would need
to be inspected at a later date.
21'2