Loading...
HomeMy WebLinkAboutPlansLC DF A MEM Railroad Tie Retaining Wall Cable 8s TeIephone Pedestals • Concrete Block Wall N78°41'21"E 56.53' IMPROVEMENT LOCATION CERTIFICATE N 87°53'47" E 27.87 S 77°14'04" E 33.01' Rebar and Cap LS No. 7972 Mountain States Telephone and Telegraph Company Easement Book 485, Page 78 / Rock Retaining Wall (Typical) Rebar and Cap LS No. 33638 .s tS� 0 D-15°25'26" R=623.25' .L=167.77' CB -N 29004'43" W CH -167.27 110- �,o eGe SCALE: 1 30' I LEGEND Power Pole Guy Wire -0 Overhead Electric _aE Fence x rctA- c.0 O V Go 50 tree i 20.0' Non-exclusive S o i Utility Easement Book 473, Page 212 wl if4-?/cf? 1111. r- 44,, West 1/4 Corner Section 26 Aluminum Cap Ls No. 19598 Reception No. 808669 50.0' \ \\ p / 4°5 PROPERTY DESCRIPTION A PARCEL OF LAND STI'UATED. IN THE SW 1 / 4NW1 / 4 OF SECTION 26, TOWNSHIP 6 SOUTH, RANGE 89 WEST OF THE 6TH P.M COUNTY OF GARFIELD,, STATE OF COLORADO, LYING NORTHEASTERLY OF THE NORTHEASTERLY RIGHT OF WAY LINE OF COLORADO STATE HIGHWAY NO. 82, SAID PARCEL OF LAND IS DESCRIBED AS FOLLOWS • BEGINNING AT AT POINT ON THE NORTHEASTERLY RIGHT OF WAY LINE OF SAM HIGHWAY WHENCE AN IRON POST WITH A BRASS CAP FOUND IN PLACE AND PROPERLY MARKED FOR THE QUARTER CORNER COMMON TO SECTIONS 26 AND 27 IN SAID TOWNSHIP AND RANGE BEARS: SI 6°54'15"W 854.35 FEET; THENCE N21 °22'00"W 50.17 FEET ALONG THE NORTHEASTERLY RIGHT OF WAY LINE OF SAID HIGHWAY; THENCE 167.77 FEET ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 623.25 FEET, THE CHORD OF WHICH BEARS N29°04'43"W 167.27 FEET; THENCE N78 °41'21 "E 56.53 FEET; THENCE N87°53'47"E 27.87 FEET; THENCE S77°14'04 "E 33.01 FEET; THENCE S39°28'10"E 95.67 FEET; THENCE S30°44'19"E 48.29 FEET; THENCE S24 °09'21 "E 33.65 FEET; . THENCE S65 °50'39"W 126.23 FEET TO A POINT ON THE NORTHEASTERLY RIGHT OF WAY LINE OF SAID HIGHWAY, THE POINT OF BEGINNING. EXCEPTING THEREFROM THE SOUTHERLY 50 FEET OF EVEN WIDTH MEASURED PARALLEL TO THE SOUTHERLY LINE OF SUBJECT PROPERTY. COUNTY OF GARFIELD, STATE OF COLORADO IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED FOR STEWART TITLE GUARANTY COMPANY, THAT IT' IS NOT A LAND SURVEY PLAT OR AN IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR .THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE, AUGUST 21, 2013 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF TEE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED :i,►: g`! 1*b Y,IMPRO VEMENTS ON ANY ADJOINING PREMISES, EXCEPT 74e7 • T THERE IS NO APPARENT EVIDENCE OR SIGN 0:: A, �• �, . y G OR BURDENING ANY PART OF SAID PARC MIC FOR • •;• e� iso• Wo BOOKCLIF t,,�y,;; CES .INC . REGISTRATION NO. 36572 DATE: 9/12/13 PROJECT NO. 13067-01 SHEET 1 OF I NDFHONS CPERMIT B LCO 2_. 1 5 -3 5 2 7 Harvey/Nesbit, arvey/Nesbit, l.. LC Office Addition/IV1tn. Pest C:ontro 3758 Hwy 82 Glenwood Springs, CO All ire+'OHL MUST COMPLY WI.).H THE 2009 IRC, iM�:, ICC, IFCI Ir=C IECC: AND N'+,/'IANl.)F AC_..I.l)RERSI IIrlS_)._AL_LIMON SPEC1r ICAT IONS PRIOR "ro COW: RUC ON, CONTACT LOCAL CAL FIRE DISTRICT FOR PERTINENT IFC FpsEQ.UIPE::(11EN.I.S. FIRE DISTRICT FINAL APPROVAL REPORT IS REQUIRED FOR FINAL/COMPLETION INSPECT -10N,, PROVIDE AN ENGINEER WET SEALED, SIGNED, AND DATED LE [TER AUTHORIZING USE OF THE UNSEALED STRUCTURAL. PLANS AT FOUNDATION INSPECTION. L; LECJRIC.AI. PERMIT FTINCa & INSPECTIONS BY THE COLORADO STATE ELECTRICAL BOARD, ELECTRICAL. ROUGH INTAPPROVAL IS REQUIRED PRIOR 1O FRAME INSPECTION ELECTRICAL FINAL APPROVAL ROVAL IS REQUIRED FOR FINAL/COMPLETION INSPECTION. LOCKS, FA,TI:, HES AND LANDINGS PER 2009 IBC, SEC IC)N 1008 LIGHT AND VENTILATION PER 2009 IBC., CHAPTER 12. c. 4r iWML d 1, y ,«r,raw '�w1lu au Ji I,a,d'1�1 IE, BLCO-2-15-3527 Harvey/ Nesbit LLC Addition 4 3758 HWY 82, Glenwood Springs iei put • LiolS L 0'OI' 0 t\iN I Kenn e X11 1111 -� oIoz 0 0 N slop 0 N N s. 508 ;uoij 0 0 co ,1 � I oloz J 0 O M aV High Country , e General Notes: The purpose of these drawings is to graphically depict the general nature of the work to be performed. The Contractor shall confirm dimensions and select fabrication processes and techniques prior to construction. All construction and materials shall be in accordance with all applicable codes, ordinances, laws, permits, and contract documents. The contractor shall be responsible for the accurate placement of all new construction. The contractor shall confine his or her operations on the worksite to those areas previously agreed on with the owner. All materials stored on site shall be properly stacked and protected to prevent damage and deterioration. Failure to protect material may be cause for rejection of work. The Contractor shall review locations of light fixtures and other recessed ceiling and wall elements prior to framing for proper placement of these items. The contractor shall verify all field dimensions and conditions, and shall notify the architect of any variations from those items shown herein. The jobsite shall be maintained in a clean, ordered condition, free of debris and litter. The jobsite shall not be unreasonably encumbered with any materials or equipment. Each subcontractor, immediately upon completing each phase of his or her work, shall remove all trash and debris as a result of his or her operation. The contractor shall do all cutting, fitting or patching of his or her work that may be required to make its several parts to fit together properly. The contractor shall not endanger any other work by cutting, excavating, or otherwise altering the total work or any other part of it. All patching, repairing and replacing of materials and surfaces cut or damaged in execution of work shall be done with applicable materials so that surfaces replaced will, upon completion, match surrounding similar surfaces. Mechanical subcontractor shall be responsible for designing and installing a code compliant heating and ventilation system. Plumbing subcontractor shall be responsible designing and installing a code compliant water, drain lines, and proper venting. Electrical subcontractor shall be responsible for designing and installing a code compliant electrical system. The Contractor shall provide all necessary blocking, backing, and framing for bathroom accessories, handrails, guardrails, electrical fixtures, mechanical equipment, recessed items, and any other items, as required. The Contractor shall be responsible for arranging all necessary inspections required by Garfield County prior to covering any such portions of work. Energy Compliance: (all values are minimum requirements) Ceilings and Ceilings w/ raised trusses: R-40 Walls Above Grade: R-20 Walls Below Grade R-11 Floor over unheated spaces: R-11 Slab Edge, 36" insulated: R-10 Glazing Requirement: Double Glazing HVAC Ducts: R-8 Air Leakage: Exterior joints around windows and door frames, openings between walls and foundations and between walls and roof/ceilings and between wall panels, openings at penetrations of utility services through walls, floor and roofs and all other similar types of openings in the building envelope shall be caulked, gasketed, weather stripped, or otherwise sealed to prevent in a manner approved by the Building Official. Vapor Retarder: Vapor retarders shall be installed in all non -vented framed ceilings and rafter spaces RR TIE wall. N 78.4.1'21" N 87'53'47" S 7775'D4" EXISTING FENCE EXISTING POWEI:UNE • EXISTING POWERUNE = 15'2524" R = 623.25 L = 167.77 CH = N 29'04'43" W 167.27 •14)"\ \ s � •,,mom WATEF3•. crr-SPIGOT \ • --POWERLiN£ •• �J Z o,\ • \ TIE TO W. 1/4 SEC. 26-� S 16'54'15- w 854.35' \ All drawings, plans, and specifications are instruments of service provided by Jeff Johnson Architectural P.C. and remain the property of the Architect. These instruments of service may not be reused without written consent by Jeff Johnson Architectural P.C. roof vent flashing 11 7/8" Ivi ledger simpson hanger 2x8 sloped overframing 5/8" sheathing fully adhered membrane EXISTING BUILDING EXISTING SHED ROOF 11 2x blocking dbl top plate New Ceiling: painted finish 1/2" gypsum board 6 mil poly vapor barrier 1 j.. /8" ceiling rafter @ 16" o.c. R-38 batt insulation vented attic cavity 16-6%2" soffit vent existing beam simpson hanger 2x blocking 2x top plate New Exterior wall: Furring/ Bearing wall: painted -finish 1/2" gypsum board 2x6 studs at 16" o.c. 1/2" gap off existing painted CMU wall \-- thickened edge, see structural epoxy and dowel per structural existing foundation stem wall EXISTING BUILDING 2x6 underframing remove existing roof overhange dbl. 2x10 header at new opening " EXIS 19'-5" iNG S New floor slab: 4" concrete, reinforced per Structural requirements, over 4" free draining aggregate base course epoxy paint with silica texture ED RO painted finish 5%2" 1/2" gypsum board 6 mil poly vapor barrier 2x6 stud wall at 16" o.c. R-19 batt insulation 7/16" ext. grade plywd. sheathing air & moisture barrier 1/2" wood siding panel 2" vertical battens @ 16" o.c. painted to match existing flashing 2x treated sill over sill sealer thickened slab edge 2" rigid insulation waterproofing backfill extend rigid insulation 24" away from foundation Building Section scale: 3/8" = 1'-0" New Ceiling: Shallow furring wall: painted finish 1/2" gypsum board 2x furring studs at 16" o.c. attached to existing wall sheathing after removing exterior siding New landing: 2x6 treated frame over new slab 5/8" plywood subfloor epoxy paint with silica texture II II I painted finish 1/2" gypsum board 6 mil poly vapor barrier 11 7/8" ceiling rafter @ 16" o.c. R-38 batt insulation ventedattir_ cay.ttyi extend exterior siding and battens to underside of existing roof deck New Exterior wall: 0 4 thickened edge, see structural epoxy and dowel per structural existing foundation stem wall East Elevation Exterior Elevations New floor slab: 4" concrete, reinforced per Structural requirements, over 4" free draining aggregate base course epoxy paint with silica texture 5%2" painted finish 1/2" gypsum board 6 mil poly vapor barrier 2x6 stud wall at 16" o.c. R-19 batt insulation 7/16" ext. grade plywd. sheathing air & moisture barrier 1/2" wood siding panel 2" vertical battens @ 16" o.c. painted to match existing flashing 2x treated sill over sill sealer thickened slab edge 2" rigid insulation waterproo ng fbackfill Building Section scale: 3/8" = 1'-0" extend rigid insulation 24" away from foundation South Elevation scale: 1/4" 1'0" Shingles Infill Existing Skylight: remove existing exterior skylight provide R-38 insulated 2x infill framing, new roof sheathing, ice & water shield, and shingles to match I J TPO membrane co lower roof Attic Ventilation Summary: Vented Roof: 355 SF Required net sq. in. 170 sq. in. (355/300) "144) eave vents: 60 sq. in. roof vents: 120 sq. in. Provided net sq. in. 180 sq. in. * r iV =a built up overframing along high wall and cut into existing adjacent slope to create new valley line to provide drainage away from high wall roofing at new overframing to be seamless white 35 mil TPO membrane with 8" overlap along valley line fully adhere membrane to 7/16" plywood sheathing and extend 12" minimum above vertical wall face, with termination bar and counterflashing shed roof above 20'-0" existing wall line 11-.1---=11 li II - I I II II II I �; a II II II ii I �1 JI^_Liroof inq bAre� _ ____n___II ` II II I II II I lm II III I it II i II 8 I I I I 01 ,,��I I Il I II c to faske t 01 8 s emt rn 11C01I I I 11 ' 1 1 I I II .- I I 1 11a @II d ldiiti r 11 m ml _-= II I I I 11 0 V I roof II II' CC i I I 11 Jj,:I 1 1 1 11� -Cl2I 1 I 1 11 43 til 1 I I II 0 •-I I 1 1 I117 '- I i 1 I il. at 1 i 1 iIJ al 1 i I = II> NI I 1 1 11J XI 1 1 1 --_ II= 01 I I I --- liC0 I 1 I 1 iii. I 1 I I ====11r I I I I iI' I l 1 I 11 1 1 1 1 1 11 11 6 Soffit vents( - 101sq. ih.edch �I 60 sq. in. Ii II II II II II 11 I II II II II iI IiII 11 II 11 Il II II 11 II II 11 II 11 It 11 20'-1Y21. N Roof Plan scale: 3/16" = 1'-0" 20'-0%2" ti Section Notes 1. All framed walls, floors and roof/ceiling compromising elements of the building thermal envelope shall be provided with moisture control. 2. Locations subject to decay damage require the use of an approved species and grade of lumber, pressure preservatively treated or decay resistant. 3. Foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be dampproofed. Roof Plan Notes 1. Enclosed attics and enclosed rafter spaces covered with a ceiling membrane shall be ventilated. 2. Complying attic access shall be provided for buildings with combustible ceilings or roof construction. 3. Provide gutter and downspout assemblies. 4. Retain existing roof overhang. Grading Notes: 1. Adequate precaution shall be taken to insure proper compactness of backfill around piping without damage to such piping. Backfill shall be free of rocks, concrete or other rubble which may damage or break pipe and should be placed in the trench in 6" layers. Suitable precautions shall be taken to insure permanent stability for pipe laid in filled or made ground. 2. Provisions shall be made for the control and drainage of water around the building. Grade so as to drain surface water away from foundation walls. The top of the foundation wall shall set at an elevation to provide grade that shall fall a minimum of 6 inches within the first 10 feet 3. All concrete for site elements shall be mixed and placed in accordance with ACI 318 latest edition, shall develop a minimum compressive strength of 3,500 PSI at 28 days, and shall be fiber reinforced. 4. Contractor shall coordinate the site earthwork with the foundation design for over excavation and structural fill placement under the building foundation if required. 6'-4" 5'-111/2" Exis ng Door 3'-0" 4'-9" XISTING WALL II II �I Ii II II II � � II ---�F--�-r J L. J L ` 1 I) I 1, 1, I J 6'-7" 2" Q `9 o z k W Infill Window: remove existing exterior window provide insulated 2x Infill framing, new wall sheathing and patch area exposed to exterior to match existing finish 3,-3" provide framing similar to new door ending as block o to enclose existing plumbing popes M„ Furring/ Bearing wall: 19'-5" painted finish 1/2" gypsum board 2x6 studs at 16" o.c. 1/2" gap off existing painted CMU wall Shallow furring wall: 0 M painted finish 1/2" gypsum board 2x furring studs at 16" o.c. attached to existing wall sheathing after removing exterior siding Abandoned drain: r - remove existing drain cover plate, expose drain line and cap -' 6" below new floor slab elevation 355 SF EXPANDED OFFICE New opening: remove existing exterior window assembly, maintain one side of existing opening framing studs and remove -extend opening width to 3'-0" provide 2ply minimum 2x10 header above New : 2x6 treated landingframe over new slab 5/8" plywood subfloor epoxy paint with silica texture existingo 3'-0%2" M concrete edge New floor slab: 4" concrete, reinforced per Structural requirements, over 4" free draining aggregate base course epoxy paint with silica texture Repurposed Window opening: frame opening in new wall for 2'-0" wide by 3'-0" high single hung window repurposed from adjacent wall New door. 3'-0" wide by 6'-8" high 9'-9" 5/8" plywood subfloor epoxy paint with silica texture 20'-1%2" r 2'-0" / 5,-4" existingt New Exterior wall: see description above New concrete egress landing N EDAddition Plan scale: 3/8" = 1'-0" New Exterior wall: pane• ns 1/2" gypsum board 6 mil poly vapor barrier 2x6 stud wall at 16" o.c. R-19 batt insulation 7/16" ext. grade plywd. sheathing air & moisture barrier 1/2" wood siding panel 2" vertical battens @ 16" o.c. painted to match existing existing retaining wall line 335 sq. ft. Johnson Carter Architects, P.C. Jeffrey Scott Johnson 136 East Third Street Rifle, CO 81650 (970) 625-0580 phone (970) 625-0581 fax www.jcarchitectspc.com Copyright 2015 0 • Fa 0 Permit Set Construction Addition Working Drawings Date: 02-05-15 1501 E-02-05-15 Al [ 1 -,f }i 41 it iI South Elevation scale: 1/4" 1'0" Shingles Infill Existing Skylight: remove existing exterior skylight provide R-38 insulated 2x infill framing, new roof sheathing, ice & water shield, and shingles to match I J TPO membrane co lower roof Attic Ventilation Summary: Vented Roof: 355 SF Required net sq. in. 170 sq. in. (355/300) "144) eave vents: 60 sq. in. roof vents: 120 sq. in. Provided net sq. in. 180 sq. in. * r iV =a built up overframing along high wall and cut into existing adjacent slope to create new valley line to provide drainage away from high wall roofing at new overframing to be seamless white 35 mil TPO membrane with 8" overlap along valley line fully adhere membrane to 7/16" plywood sheathing and extend 12" minimum above vertical wall face, with termination bar and counterflashing shed roof above 20'-0" existing wall line 11-.1---=11 li II - I I II II II I �; a II II II ii I �1 JI^_Liroof inq bAre� _ ____n___II ` II II I II II I lm II III I it II i II 8 I I I I 01 ,,��I I Il I II c to faske t 01 8 s emt rn 11C01I I I 11 ' 1 1 I I II .- I I 1 11a @II d ldiiti r 11 m ml _-= II I I I 11 0 V I roof II II' CC i I I 11 Jj,:I 1 1 1 11� -Cl2I 1 I 1 11 43 til 1 I I II 0 •-I I 1 1 I117 '- I i 1 I il. at 1 i 1 iIJ al 1 i I = II> NI I 1 1 11J XI 1 1 1 --_ II= 01 I I I --- liC0 I 1 I 1 iii. I 1 I I ====11r I I I I iI' I l 1 I 11 1 1 1 1 1 11 11 6 Soffit vents( - 101sq. ih.edch �I 60 sq. in. Ii II II II II II 11 I II II II II iI IiII 11 II 11 Il II II 11 II II 11 II 11 It 11 20'-1Y21. N Roof Plan scale: 3/16" = 1'-0" 20'-0%2" ti Section Notes 1. All framed walls, floors and roof/ceiling compromising elements of the building thermal envelope shall be provided with moisture control. 2. Locations subject to decay damage require the use of an approved species and grade of lumber, pressure preservatively treated or decay resistant. 3. Foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be dampproofed. Roof Plan Notes 1. Enclosed attics and enclosed rafter spaces covered with a ceiling membrane shall be ventilated. 2. Complying attic access shall be provided for buildings with combustible ceilings or roof construction. 3. Provide gutter and downspout assemblies. 4. Retain existing roof overhang. Grading Notes: 1. Adequate precaution shall be taken to insure proper compactness of backfill around piping without damage to such piping. Backfill shall be free of rocks, concrete or other rubble which may damage or break pipe and should be placed in the trench in 6" layers. Suitable precautions shall be taken to insure permanent stability for pipe laid in filled or made ground. 2. Provisions shall be made for the control and drainage of water around the building. Grade so as to drain surface water away from foundation walls. The top of the foundation wall shall set at an elevation to provide grade that shall fall a minimum of 6 inches within the first 10 feet 3. All concrete for site elements shall be mixed and placed in accordance with ACI 318 latest edition, shall develop a minimum compressive strength of 3,500 PSI at 28 days, and shall be fiber reinforced. 4. Contractor shall coordinate the site earthwork with the foundation design for over excavation and structural fill placement under the building foundation if required. 6'-4" 5'-111/2" Exis ng Door 3'-0" 4'-9" XISTING WALL II II �I Ii II II II � � II ---�F--�-r J L. J L ` 1 I) I 1, 1, I J 6'-7" 2" Q `9 o z k W Infill Window: remove existing exterior window provide insulated 2x Infill framing, new wall sheathing and patch area exposed to exterior to match existing finish 3,-3" provide framing similar to new door ending as block o to enclose existing plumbing popes M„ Furring/ Bearing wall: 19'-5" painted finish 1/2" gypsum board 2x6 studs at 16" o.c. 1/2" gap off existing painted CMU wall Shallow furring wall: 0 M painted finish 1/2" gypsum board 2x furring studs at 16" o.c. attached to existing wall sheathing after removing exterior siding Abandoned drain: r - remove existing drain cover plate, expose drain line and cap -' 6" below new floor slab elevation 355 SF EXPANDED OFFICE New opening: remove existing exterior window assembly, maintain one side of existing opening framing studs and remove -extend opening width to 3'-0" provide 2ply minimum 2x10 header above New : 2x6 treated landingframe over new slab 5/8" plywood subfloor epoxy paint with silica texture existingo 3'-0%2" M concrete edge New floor slab: 4" concrete, reinforced per Structural requirements, over 4" free draining aggregate base course epoxy paint with silica texture Repurposed Window opening: frame opening in new wall for 2'-0" wide by 3'-0" high single hung window repurposed from adjacent wall New door. 3'-0" wide by 6'-8" high 9'-9" 5/8" plywood subfloor epoxy paint with silica texture 20'-1%2" r 2'-0" / 5,-4" existingt New Exterior wall: see description above New concrete egress landing N EDAddition Plan scale: 3/8" = 1'-0" New Exterior wall: pane• ns 1/2" gypsum board 6 mil poly vapor barrier 2x6 stud wall at 16" o.c. R-19 batt insulation 7/16" ext. grade plywd. sheathing air & moisture barrier 1/2" wood siding panel 2" vertical battens @ 16" o.c. painted to match existing existing retaining wall line 335 sq. ft. Johnson Carter Architects, P.C. Jeffrey Scott Johnson 136 East Third Street Rifle, CO 81650 (970) 625-0580 phone (970) 625-0581 fax www.jcarchitectspc.com Copyright 2015 0 • Fa 0 Permit Set Construction Addition Working Drawings Date: 02-05-15 1501 E-02-05-15 Al THIS SHEET r------------------- ------------------- 4' CONCRETE SLAB REINFORCED WITH W6 -W6 6/6 W.W.M. SUPPORTED ONSUITABLE CHAIRS AT CENTER OF SLAB. SLAB TO BE PLACED ON4"OF GRANULAR FILL COMPACTED TO 95% SPD. SUBGRADE TO BE COMPACTED TO 95% SPD AT OPTIMUM MOISTURE (f2%) CONTROL JOINTS TO BE 3/4' DEEP SAW -CUTS AT 10'o/cEW. NOM. FLOOR SLAB FINISH TOBESTEEL TROWEL AND FLATNESS TO BE F30/F20 LOCAL AND F45✓F30OVERALL. cn m m 3'-4" 3'-O" I c5(E) BU/LDING----1I DETA/L-1 20=0" 13=8" FOUNDATION PLAN SCALE. 1/4"= 1=0" DETAIL -2 #5 T&B CONT w/#3 TIES AT 18'c% WWM TYP.—\ a �- #5DIAG. AT 18' o/c FIN. GRADE N RIGID INSULATION INSULATION TYP. (E) BUILDING I rJ L1 L___J DETAIL -3 DETAIL -2 #5DOWELS AT 48"o/c EPDXY INTO (E) FOUNDATION "CONT EXP JOINT (E) FOUNDATION—r— STRUCTURAL DESIGN CRITERIA THE DESIGN CRITERIA AND CODES FOR THIS PROJECT ARE AS FOLLOWS. BALCONYL/VELOAD = 100PSF(2009/BC) WOOD & TIMBER = A/TCAND NDS LATEST ED/T/ONS STRUCTURES HAVE NOT BEEN ANALYZED FOR STABILITY DURING CONSTRUCT/ON REINFORCED CONCRETE NOTES 1. REINFORCED CONCRETE SHALL BE DESIGNED, MIXED AND PLACED IN ACCORDANCE WITH THE LATEST EDIT/ON OF THE ACI CODE AND APPLICABLE ASTM STANDARDS PLACEMENT OF CONCRETE IN COLD WEATHER SHALL MEET THE RECOMMENDATION OFACI 306, AND ACI 305FOR HOT WEATHER CONCRETE PLACEMENT. 2 ALL REINFORCING BARS BEING PLACED BY THE CONTRACTOR, #4 OR LARGER, SHALL BE NEW GRADE 60 DEFORMED BARS. #3 SHALL BE GRADE 40 DEFORMED BARS, WHICH CONFORM TOASTM A615 3. REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN ANY MANNER WHICH WOULD BE INJURIOUS TO THE STEEL. BARS WITH KINKS OR BENDS NOT SHOWN ON THE BAR BENDING DIAGRAMS SHALL NOT BE PLACED. THE USE OFHEAT TO STRAIGHTEN OR BEND REINFORCING STEEL WILL NOT BE PERMITTED UNLESS SPEC/FICALL YAPPROVED BY THE ENGINEER REINFORCING BARS SHALL BE PROPERLY SUPPORTED, TIED, ANDIOR ANCHORED TO PREVENT DISPLACEMENT. MINIMUM LAP SPLICES SHALL BE(32) BAR DIAMETERS U.N.O. ANY EMBEDDED ITEMS NOT SHOWN ON THESE PLANS SHALL NOT BEPLACED IN CONCRETE WALLS, BEAMS, OR OTHER STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL. 4 CONCRETE FOR THE PROJECT SHALL BE AS FOLLOWS' ASTM C-150 TYPE//l/PORTLAND CEMENT WITHA WATER/CEMENT RATIO (W/C) NOT TO EXCEED 050, ANDA MINIMUM COMPRESSIVE STRENGTH ASFOLLOWS- FOUNDATION AND FLOOR SLAB ELEMENTS = 3,000 PSI ALL CONCRETE SHALL CONTAIN50% (± t0%) ENTRAINED AIR AT THE POINT OF PLACEMENT AIR ENTRAINING AGENT SHALL BESHOWN IN THE DESIGN MIX CONCRETE SHALL BE MIXED IN APPROVED TRANSIT MIXERS MAX/MUM ELAPSED TIME FROM THE TIME THAT WATER IS ADDED TO THE MIX UNTIL THE CONCRETE IS DEPOSITED IN THE WORK SHALL NOT EXCEED 90 MINUTES ONLY THOSE ADMIXTURES SPECIFIED /N THE CONTRACTORS MIX DESIGN SUBMITTAL SHALL BE USED. CONCRETE SHALL BE MIXED FOR NOT LESS THAN 70 NOR MORE THAN 100REVOLUTIONS ATM/XING SPEED PRIOR TO PLACEMENT. NOM MAX SLUMP SHALL NOT EXCEED 4" 5 ENGINEER'S PRIOR APPROVAL MUST BE SECURED FOR ALL SUBSTITUTIONS 6. UNLESS OTHERWISE NOTED, THE MINIMUM CLEAR DISTANCE BETWEEN THE FACE OF CONCRETE AND THE OUTSIDE OF THE REINFORCING BARS SHALL BE 1" 7 CONSTRUCTION JOINTS NOT SHOWN ON THE DRAWINGS SHALL BE LOCATED TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE AND THE LOCATION MUST BE APPROVED BY THE ENGINEER 8. BEFORE ANY CONCRETE IS PLACED, APPLICABLE DRAWINGS SHALL BE CHECKED TO DETERMINE THA TANCHOR BOLTS, EMBEDDED STEEL, PIPING, CONDUITS, GROUNDING WIRES, OPEN/NGS, ETC. ARE PROPERLYPLACED 9. LATERAL SUPPORT SHALL BE PROVIDED FOR ALL WALLS DURING BACKFILLING AND CONSTRUCTION OPERATIONS 10. FOR CATHODIC PROTECTION, ALL UNDERGROUND CONCRETE WITH EMBEDDED PIPING OR INSERTS WHICHAREA PART OF THE PIPING SHALL HAVE MINIMUM OF 1-1/2" CLEARANCE BETWEEN REBARS AND SUCHINSERTS ANCHOR BOLTS SHALL BE SET WITH TEMPLATES. 11. ANCHOR BOLT MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307 OR ASTM A36. MATERIAL FOR ANCHOR BOLTS SHALL BE AS INDICATED ONA PARTICULAR DRAWING. IF NO MATERIAL IS SPECIFIED ASTM A-307 SHALL BE USED. ANCHOR BOLTSAND OTHER PROJECTING EMBEDMENTS SHALL BE SET WITH TEMPLATES OR OTHER APPROVED METHODS TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. 12 WELDING OF REINFORCING, PIPE SLEEVES, ETC TO ANCHOR BOLTS WILL NOTBEPERMITTED UNLESS OUTLINED ELSEWHERE IN THESE NOTES 13. ALL EXPOSED UNFORMED CONCRETE SURFACES SHALL BE OF UNIFORM FINISH AND COLOR ALL FORMED SURFACES SHALL HAVEDEFECTSAND BLEMISHES PATCHED AND REPAIRED INA WORKMAN LIKE MANNER 14. WELDED PLAIN WIRE FABRIC FOR CONCRETE REINFORCEMENT SHALL CONFORM TOASTM A185 15 WHERE ALLOWED ON THE PLANS SLABS ON GRADE(SOG) MAYBE REINFORCED WITH SYNTHETIC FIBER ADDIT/VECONTAINING A MINIMUM OF 1.5 LBS OF COLLATED, FIBRILLATED POLYPROPYLENEFIBERSPER CUBIC YARD OF CONCRETE AND THOROUGHL YM/XED INACCORDANCE WITH THE MANUFACTURERS DIRECTIONS 16. SPLICES IN REINFORCING STEEL SHALL BE/NACCORDANCE WITH DETAILS SHOWN ON THE DRAWINGS OR INACCORDANCE WITH THE ACI DETAILING MANUAL (LATEST ED.). LOCATION OF SPLICES NOT SHOWN ON THEDRAWING SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER MINIMUM LAP SPLICE LENGTHS FOR REINFORCING BARS SHALL BEINACCORDANCE WITH ACI SP-66AC1 DETAIL INC MANUAL LATEST EDITION UNLESS OTHERWISE SHOWN ON THE DESIGN DRAWINGS 17. WHEN CALLED FOR ON THE PLANS BASEPLATES, OR STEEL BEAMS RESTING ON CONCRETE OR MASONRY FOUNDATIONS SHALL RECEIVEA MIN OF 1" STRUCTURAL NON -SHRINK GROUT UNLESS OTHERWISE NOTED ON THE DESIGN DRAWINGS STRUCTURAL GROUT SHALL HAVE MIN/MUM COMPRESSIVE STRENGTH OF 5000 PSI AT28 DAYS ALL GROUT SHALL BE MASTER BUILDERS CO. OR APPROVED EQUAL. 18. FOOTINGS HAVE BEEN SIZED INACCORDANCE WITH THE EARTH ENGINEERS, INC REPORT INDICATING MINIMUM ALLOWABLE BEARING PRESSURE OF 1,500 PSE (REFERENCE JAMES JACKSON REMEO, P.E. DRAWING S-1 DATES 5/4/09). WOOD FRAMING NOTES 1. ALL WORK WITH MANUFACTURED AND SAWN DIMENSIONAL LUMBER SHALL CONFORM TOA.L TC. ANDN.D.S LATEST EDITIONS NON-BEARING WALL STUDS, EXCEPT LAM. STUDS MAYBE HEM -FIR #2 UNLESS OTHERWISE NOTED ON THE DRAWINGS BEARING WALLS, SAWN TIMBERS, POSTS, LAM STUDS, JOISTS AND RAFTERS 31/2"AND LARGER SHALL BE HEM -FIR U.N.0.. BEARING WALLS SHALL BE2x6AT 16" o/c WITH DBBL. TOP PLATE U.N.O.. DOUBLE TRIMMERS SHALL BE INSTALLED AT ALL STRUCTURAL HEADERS LOAD BEARING HEADERS SHALL BE (3)-2x10x6'MAX. SPAN WITH CONTINUOUS PLYWOOD SPACERS U.N.O. ON THE DESIGN DR4WINGS MINIMUM NAILING SHALL BE IN ACCORDANCE WITH NDS TABLES ALL EXPOSED FRAMING AND WOOD MEMBERS IN DIRECT CONTACT WITH CONCRETE ELEMENTS SHALL BE TREATED PER NDS, OR PROTECTED WITHA MOISTURE BARRIER WOOD TREATMENT METHOD SHALL BE COMPAT/BLEWITH THE ANCHOR SYSTEM USED WITH THE TREATED WOOD MEMBERS 2 INSTALLATION OF ALL FRAMING AND CONNECTIONS SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL DESIGN STANDARDS (NDS) LATEST EDITION. INSTALL SHIMS AND EDGE CLIPS AS REQUIRED. ALL PLATE CONNECTORS SHALL BE AS MANUFACTURED BY SIMPSON STRONG TIE COMPANY OR APPROVED EQUAL FOR ALL JOISTS, RAFTERS, TRUSSES, BEAMS, AND COLUMNS FOR APPROPRIATE SIZE AND STYLE PLATE CONNECTORS SHALL BE INSTALLED WITH NAIL SCE AND NUMBER FOR MAXIMUM FORCE. 3. NOTCHING OR CUTTING OF STRUCTURAL MEMBERS IS PROHIBITED UNLESS SPECIFICALL YSHOWNAND DETAILED ON THE DRAWINGS 4. MANUFACTURED WOOD PRODUCTS SHALL BEHANDLEDAND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. ALL BEAR/NG LENGTHS, BLOCKING, HANGERS, CONNECTORS, NA/LING STIFFENERS, ETC. SHALL MEET THE REQUIREMENTS OF THE MANUFACTURER. 5 ALL WOOD FRAMEWALLS SHALL BE CONTINUOUSL YSHEATHED WITH 7/16"OSB SHEATHING NAILED WITH 8d GAL V NAILS AT 6"o/cATALL EDGES AND 12" o/c IN THE FIELD. SHEAR WALLS WHERE CALLED FOR SHALL BE NA/LED WITH 10d GAL V NAILS AT3"a/cATALL EDGES AND 6"AT INTERMEDIATE FRAMING BLOCK ALL EDGES OF SHEATHING ON SHEAR WALLS FLOORDIAPHRAGMS SHALL CONSIST OF 3/4" MG CD PL'WOOD OR BETTER PLYWOOD SHALL BE INSTALLED WITH GLUE AND NAILS 6 GLUED -LAMINATED MEMBERS SHALL BEDFL 24F -V4 OR BETTER, UNLESS NOTED OTHERWISE ON THE DESIGN DRAWINGS 7 BEAM DEFLECTION SHALL BE LIMITED TOL/360 UNLESS OTHERWISE NOTED ON THE DESIGN DRA WINGS. TJI DEFLECTION TO BE LIMITED TO 12480 8. MIL TI -PL YL VL BEAMS SHALL BE CONNECTED TOGETHER IN SUCHA MANNER THAT A COMPOSITE BEAM IS ACHIEVED. MANUFACTURERS DIRECTIONS AND INSTRUCTIONS SHALL BE FOLLOWED. COMPOSITEL VL BEAMS TO BE20EMINIMUM ALL LVL BEAMS SHALL BE 1.75"x DEPTH SHOWN. .9. WOOD PLATES SHALL BEANCHORED TO THE FOUNDATION AND SHALL BE FOUNDATION GRADE REDWOOD, OR PRESSURE TREATED HEM FIR, AND SHALL BEANCHORED WITH 5/8"0'x 10" EMBEDMENT ANCHOR BOLTS SPACED NOT MORE THAN 48"ON RUNS, AND NOT MORE THAN 6"FROM CORNERS, AND ALL PLATE ENDS INCLUDING BUTT SPLICES. 10. PROVIDE SOLID BLOCKING, INCLUDING WEB STIFFENERS AT TJ//s, BETWEEN ALL JOISTSAND RAFTERS AT BEARING POINTS PROVIDE RIM JO/STS OF EQUAL DEPTH AT THE PERIMETER OF ALL JOIST/RAFTER FRAMING TO INCLUDE OPEN/NGS 11. FABRICATED METAL PLATE CONNECTED TRUSSES SHALL BE DESIGNED FOR THE LOADS SPECIFIED AND SHALL CONFORM THE THE REQUIREMENTS OF THE TRUSS PLATE INST/TUTE(TPI). CONNECTOR PLATES SHALL BEIBCOAPPROVED WITHA MINIMUM SIZE OF 3"x5". ALL CHORD MEMBERS SHALL HAVE LUMBER GRADE STAMPS ALL WEB MEMBERS SHALL BE OF THE SAME GRADEAS THE CHORDS WITH ATLEAST 50 PERCENT OF THE WEB MEMBERS HAVING GRADE STAMP TRUSSDESIGNAND DETAILS SHALL BE CERTIFIED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. TRUSS MANUFACTURER SHALL PROVIDE TRUSS DETAIL DRAWINGS SHOWINGASA MIN/MUM THE MEMBER SIZES, LOCATIONS, GRADES, CONNECTIONS, BEARINGS, LOADS, REACTIONS, AND ERECTION PLANS WITH TEMPORARY BRACING AND HANDLING REQUIREMENTS. 12 ALL CONNECTIONS REQUIRING LEAD HOLES, PILOT HOLES. SCREWS, LAG SCREWS, ETC, SHALL CONFORM TO NDS COUNTERSINKING IS NOT PERMITTED WITHOUT APPROVAL. NOTCHING OF STRUCTURAL WOOD MEMBERS SHALL CONFORM TO NOS STANDARDS 13. PROVIDE SUFFICIENT WIDTH OF SAWN POSTS OR LAMINATED STUDS FOR AT LEAST 4'M/N/MUMBEARING ATALL BEAMS AND AT BEAM SPLICES U.N.O.. ALL MUL TI -PLY (LAM.) STUD POSTS SHALL BE NAIL/GL UE LAMINATED. NOTE' UPON RECEIPT OF THIS DRAWINGS THE CONTRACTOR/BUILDER SHALL MAKEA THOROUGH AND DETAILED REVIEW OF ALL ELEMENTS OF THIS DRAWING AND NOTE ANY DISCREPANCIES, CONFLICTS, ERRORS, OMISSIONS, OR OTHER IRREGULARITIES, AND PROMPTL YREPORTANYSUCHFINDINGS TO THEOWNERAND THE ENGINEER PRIOR TO ANY PROCUREMENT, FABRICATION OR CONSTRUCTION 0' 8' 16' 32' 64' 11 1 1 1 1 1 l_I1IL11Il� 1 1 1 1 1.1_1 1 I I T I I I I Graphic Scale DO NOT SCALE DRAWING FOR COMMERCIAL OR CONSTRUCTION PURPOSES Centimeters Inches Tenths 111111111 111111111 111111111 '11 '11 '11111 ELECIRGW/C DAM /NTERCHANCE Nona: /Ns NOW Wit NOT HE lifillOWD MOM na' MOOG t t: t/ l ham• t zz 1.L 0 w 0 w a: w w w C4 DRAWING NUMBER DRAWING NUMBER DRAWING NUMBER 0 w oc 0 z w 0 A 04 FEB 2015 30 JAN 2015 ISSUED FOR CONSTRUCTION ISSUED FOR APPROVAL NUMBER DATE REVISION DESCRIPTION ENGINEERS SEAL CM • STRIZ1LR4L RIFLE, COLORADO 970— 625-2774 A.S.C.E. N.S.P.E. CC.E.C. DRAWING ISSUE STATUS APPROVED FOR CONSTRUCTION 15-ATE1 04 FEBRUARY 2015 MOUNTAIN PEST CONTROL BUILDING ADDITION DRAWN: CHECKED: ACAD2015 01/15 SAK APPROVED: SCALE.- 1/4" = 1'-0" FOUNDATION PLAN AND DETAILS CAD FILENAME PROJECT NUMBER: GLENWOOD SPRINGS, COLORADO S1.1