Loading...
HomeMy WebLinkAboutOWTS Installation Observations 10.23.16 October 23, 2016 Project No. C1220 Earl McKerrihan Earl@mckcompany.net Onsite Wastewater Treatment System (OWTS) Installation Observations 388 Hidden Glen Road Lot 20, Mountain Springs Ranch Garfield County, Colorado Permit Number SEPT-04-16-4148 Earl, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on July 21, 2016 for the subject property. Miles Rippey installed the system. The system installation included a 1250-gallon, two-compartment concrete septic tank with an Orenco® ProPak and PF3005 pump in the second compartment. There is a filter in the second compartment of the septic tank. This filter must be cleaned annually, or as needed. The pump floats are set to dose approximately 90 gallons per dose. The control panel for the pump was placed within line of sight of the septic tank. Valley Precast personnel performed start up on the pumping system. Effluent is pumped through a 1.5-inch diameter Schedule 40 discharge pipe to an automatic distributing valve (ADV) Model 6402. The ADV is placed at the high point of the system and is accessible from grade. Effluent is distributed to two pressurized 12’ x 41’ beds with 1-foot of ASTM C33 concrete sand installed at the bottom of the over-excavated STA. Two rows of 10 Eljen® A42 modules are placed on top of the sand filter material in each bed and connected with level 1.5-inch diameter manifolds. Effluent is pressurized through 1.5-inch laterals, with 5/32-inch orifice holes facing UP (12-o’clock) with the first and last holes facing DOWN (6-o’clock) for drainage, 3-feet on center. Laterals are placed inside 4-inch diameter perforated SDR 35 pipe (with holes at 4 and 8 o’clock), per Eljen® specifications. Each 1.5-inch diameter lateral ends in a sweeping ell facing up with a ball valve for flushing. Inspection ports are located in all four corners of each bed. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OW TS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P.E. Eljen Beds Eljen Beds Filter fabric covering modules Invoice for sand filter material Septic tank lids ADV Lid Second compartment of septic tank ADV (recommended screened rock at base of filter) 832‐R‐13‐002