HomeMy WebLinkAboutAs-built4" 0
SOLID PIPE
SIDES
RO�GHEN
COUPLING -
PROPERTY
LINE
REMOVABLE CAP
4 - 1/2" VENT HOLES
CUT HOLE IN TOP OF
INFILTRATOR UNIT FOR
INSTALLATION OF INSPECTION
WELL PIPE
PROPOSED 4
BEDROOM
RESIDENCE
MANWAYS ARE BURIED
AND COVERED WITH A
CONCRETE CAP UNDER
THE IMPROVED ROAD.
(MANHOLES TO BE
D WHEN THE FINAL
SH D DRIVEWAY IS.
ESTA ED FOR
MAINTENANCE AND R
„
MIN, t'
4" 0 PERFORATED PIPE
VA/ VA VA/SVA//VA//VA//VA/SVA
34"
INSPECTION WELL DETAIL
N.T.S.
INSTALL CLEANOUT (TYP.)
POWER
POLE
4"0 PVC SEWER
MIN. 1/4 INCH PER FOOT SLOPE
2000 GALLON
SEPTIC TANK
(4" RISER FOR
CLEANING)
SPIGOT
WATER
VALVE
CLEANOUT
•
CONC.. PAD
GRAVEL
AREA
CLEANOU
DRY GULCH
co'
PERCOLATION TEST
HOLE P2
4"0 PVC SEWER (TYP.)
,
PERCOLATION TEST
HOLE P1
CLEANOUT (TYP.)
INSPECTION WELL (TYP.)
REMOVABLE PVC CAP
INSTALL MARKER IF CAP
IS TO BE BURIED
FINISH GRADE
4" COUPLING
4" SEWER LINE
FLOW
4" x 4" x 4"
PVC WYE
4"
RISER
PERCOLATION TEST
HOLE P3
4" 45' SWEEP BEND
CLEAN OUT
ASSEMBLY
SEWER CLEAN OUT DETAIL
N.T.S.
2H: 1 V SLOPE MAX
EXISTING GROUND -\
VA/SAA AAA\ AV A
INFILTRATOR UNI --�
/ / 4' MINIMUM /
// / / / / / /\TOj GR OU N D WA T
\\ \\ \\\ \%
TO OR
N
5
ONSITE BACKFILL
- 12" MIN. COVER CAPABLE OF H-10 LOADING
48" MAX. COVER
ti
0
GRAPHIC SCALE
,;i.
SITE
}ti
( IN FEET )
1 inch = 20 ft.
LEGEND
EXISTING BOUNDARY LINE
EXISTING 5' MAJOR CONTOUR
EXISTING 1' MINOR CONTOUR
EXISTING GRAVEL ROAD
AS -BUILT AS OF 10/24/11
6" MIN SAND BELOW INFILTRATOR
\\ //\\/\\ \\ \
\ /\
\/\/\/\\/\/\/\/\/\/\/\/\/\/\/\//\/\ \ \
\ \\ �V\may\\
/\\ \ViVi�\jVAjVAjVAjVAjVAjVAjVAjVAjVAjVAjVA/VA/VA//VA/VA/VAjVA%VA% �% �/ - ,
/V/A/A////A/A/�A/�/�A/A/�A/A/A/�A%/A/SA/SA/VA/VAA \ VAA V�
// // // // / // / / / /
\\A\A\A\A\A VA VA VAAVVVV/A/VA/VA/VA/VA/VA/VA/V/A\ VA \
\ \ /\ /\ /� i, i, i, �A//A//A//A//A//A//A//A//A//A//A//A//A��A//A//A//
\ \V'V/A/A/A/A/A/A/A/A/A/A/A/VA/A�VA/VA/A
\/\/\//////��A/A//A//
\/\/A/A/A/A/VA/VA/VA/VA/VA/VA/A(VAVA/
/V/A/SA/\��N���/��V�/�A
\/\/
TYPICAL CROSS SECTION
N.T.S.
3H:1V SLOPE OR FLA -TER
TO EXISTING GRADE
VICINITY MAP
SCALE: 1"=2000'
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY
REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH
ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS
ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS.
2. FLOW FOR BED:
6 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY IS:
900 GPD = AVERAGE DAILY FLOW.
DESIGN FLOW = 1.5 * AVERAGE = 1350 GPD (Q)
SEPTIC TANK:
MINIMUM TOTAL TANK SIZE:
Q * 1 DAY/24 HRS * 30 HRS = 1688 GPD -> USE 1750 GPD MINIMUM
INSTALL ONE 1,750 -GALLON TANK WITH BAFFLE
STANDARD ABSORPTION AREA:
A = Q iF Q = MAXIMUM FLOW
5 t = PERCOLATION RATE = 30 min./in.
= 135055 = 1479 SF
5
USE OF STANDARD INFILTRATOR UNITS
IN TRENCH CONFIGURATION:
50% REDUCTION (1479 SF * 0.50) ® 9.87 S.F./UNIT,
75 UNITS REQUIRED (UP TO 6 BEDROOMS ALLOWED).
3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEWER.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL
WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA,
TO PREVENT INFILTRATION.
5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW
LANDSCAPING.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN ONE-HALF FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION
FIELD AREA USING DRAINAGE SWALES AS NECESSARY.
9. THIS SYSTEM IS BASED ON SOILS AND PERCOLATION INFORMATION PROVIDED
BY HP GEOTECH. JOB NO. 108 543A, DATED OCTOBER 29, 2008.
INDICATING AN AVERAGE PERCOLATION RATE OF 30 MIN/IN. (THE SOIL PROFILE
CONSISTED OF APPROXIMATELY 1FT OF TOPSOIL OVERLAYING APPROXIMATELY
8 FT OF SILTSTONE/CLAYSTONE.)
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE
OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. THE
ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL
AND PROVIDE REPORT TO COUNTY.
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH
OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS
OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
12. SITE PLAN INFORMATION FROM ARCHITECT.
13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS
LESS THAN 5.0 FEET.
14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO
BACKFILLING OF SYSTEM COMPONENTS.
15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME
OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING
TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE
DESIGNED SYSTEM.
16. HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS
OR XERXES FIBERGLASS EQUIVALENT.
17. IT IS ASSUMED NO WELLS WILL/ARE LOCATED WITHIN A 100' RADIUS.
18. MINIMUM GRADE OF HOUSE SEWER SHALL BE 1/8" TO 1/4" PER LINEAR FOOT.
19. A TEMPORARY SERVICE IS BEING UTILITZED FROM A TRAILER UNTIL THE HOUSE
CONSTRUCTION IS COMPLETE.
20. THE SYSTEM IS OVERSIZED FOR THE PROPOSED 4 BEDROOM HOUSE. THERE
IS CAPACITY FOR ANOTHER 2 BEDROOMS OR ANOTHER BUILDING WITH A
EQUIVALENT USE OF 2 BEDROOMS SOMETIME IN THE FUTURE.
TRENCH NOTES
1. ABSORPTION LATERALS SHALL NOT EXCEED 100 -FEET IN LENGTH.
2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL.
3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS
NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA.
4. TRENCH LATERALS SHALL FOLLOW CONTOURS.
5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS
INCURRED DURING EXCAVATION.
7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER
AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED
8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND
BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL.
9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED
INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND
PROTECT THE BACTERIAL BIO -MAT.
10. BEND IN TRENCH SHALL BE MADE WITH END PLATES AND 4"0 PVC OR
MANUFACTURER'S PREFABRICATED BENDS, OR WITHIN THE LIMITS
OF THE QUICK 4 CHAMBER.
W
CC z
Z • aOC7J
Opp 0 QQYS
U< z�<W
�� N � Q�W�
O c�=w
ZU (V _Z �Cj►-�
it oil" 0 O �=�o
c_fi
JfY 0 WOOZ
HW O ZwwO
w CO 0 mOa�
<U Cr) • Nli-Qw
U
▪ fn 0 < WZ
0
NO. DATE REVISION BY
1 8/9/10 REVISED PER ASBUILT CONDTIONS. DRD
2 11/29/11 REVISED PER 10/24 INSPECTION. DRD
REVISED PER ASBUILT CONDTIONS.
REVISED PER 10/24 INSPECTION.
2
0
m
0
w
U
C
0
CO
a ; ;I :
0 z
fx u w-6 41i
Li. -05:
<tx 2 0-
o Z
CO
ict
co
ict
0
PROJECT NO
2081037.00
0218
ISDS