Loading...
HomeMy WebLinkAboutApplication-PermitGarfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945 ·8212 Fa x: 970-384 -3470 In spection Line: 970-384 -5 003 Building Permit No. ____._l-'------'-/2---=cJ.....:.Le....._______l --- Parcel No: 2187-363-00-156 ----- Locality: Job Address: CR 115 GWS Use of Building: s/f with covered patios & attached garage ------ Owner: Lovatt , Sarah I Boyle~,_T....:.im ___ _ Contractor: Two Trees Canst. Inc . --- Fees: Plan Check: $ 871 .62 Septic: $ 173.00 Bldg Permit: $ 1,340.95 Other Fees: Total Fees: $ 2,385.5 7 Clerk: @h. )/lij:'J'f ~--' Date: :"iJ-u· L {.1!:/ il ~ I I ~1~ 3 GA RFIELD COUNTY BUlLDTNG PER.MlT APPUCAT ION 108 8th St.reet, Suite 40 1, Glenwood Spr ings, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 IVWiv.garfield-county.com P 2 ll ~ ~3th3ooait5a6c assessors office 970-945-9134) Job Address: (if an address has not been assigned , please provide Cr. Hwy or Street Name & City) or and legal description COOivT( rZ.J) \I 5 Gl-£\JWOOY Sf'(Z I ~G-5 (d 8/6 0 \ Lot No: j) B lock No: S ubd./ Exemptio n : 4 OwnerUproperty o'f"ld ~~1 ~-A&ox 3544-J'*~ co Ph · 6 16 O f Cl ( 1~3l : 6J$.qo5 ~ SPI~t\ LoVA , t i M BOYLE q7() 5 Contractor: "fvJo ·1i21=£5 coNSf~u:: TiaJ rNc Ma~ing Addre5 XXiP Sf( ~for 2q Z Cf<-ll 16't.£wt -c 0 ~·f r p2t ·?0-38'1-2240 ~It Ph :~..;t J '"9-0-7L-1 -I 5 80 6 Architecl~ineer:) Mai ling Address: PhCf90 qzr-4-3b3 AIL Ph: A W3 f:: I G-1+ T ~A 55"CC rA i1ES ~02 PARI< Ft\JE., &\SAl-T '3 /62..1 7 Sq. Ft. of Building: I g ·9-b Sq. Ft. or Acres of Lot:3 5 •4-Z=t-flciZ.E5 Height: '2. '2.. S F T No. of Floors: .... L-. 8 Use of Bu i lding :~ 1 rJG-l-£ ... FA I\ I I.. Y --:ov>v=L--L t ~ 6-w/ ~ pcdito~ ~ o.-. .... .A._ ... sz.. 9 Desc r ibe Work: C.QrV STf2.U CTt ot-J . ' (J u ('f£f,..J . 5 -n C k F'<R 1"\E ") 10 Class of Work: lit'Ncw o Alleration o Addit ion II Garage: Septic: !ii"Attached 0 Detached r/ISDS o Community !2 Driveway Permit : GI<I503 -~-\2..2... Owners valuation of Work: $Ci:QOCX) NOTICE A u rhoriry. l11is application for a Building Pennit mus1 be signed by I he Owner of the prop~rty, described above. or an authorized agent. I f the signature below is no1 thai of the Owner, a separate: lencr of au thority, signed by the Owner. mu st be provided with thi s Application. l.egnl Access. A Building, Permit cannot l>c issued without proofoflcgnl and adequat e access to t he property for purposes of in spect ions by the 13uilding Department. Other Permits. Multiple separate pen nits may be req uired : (I ) Stale Electrical Permit, (2) Co ullty ISDS Pem>il , (3) another penni I r.quired for usc on ~te propctty ide nt ified a bove. e.g. State or Coun ty Highway/ Rond Access or a S tate Wastewater Discharge Pennit. Void Permit. A Building l'ermit becomes null and void if the work authorized is not commenced within 180 days o f~te date of issuance and if work is suspended or abandoned for a period of 180 days after coanmcnccmenl. CERTIFICATION I hereby certify that I hnvc: rc:ad I h is Application and that the informat ion contained al>ovc is true and correct. I underst and thnt t he Buildi ng Department accepts the Application, nlong. with the plnnCi ::and sp ecificatio n s nud o rhcr data submitted by me or on my I.Jehalf(subnUttnls), bast:d upon my certification as to accuracy. Assuming completeuess of the submiH nls and approval of this Application, a Building PennH will be issued grnut ing permission to me, as Owncr.to con struc t the stnactun:(s) and fn cilitics detaih::c.l 011 the su bmillals reviewed by the Building DcpartmenL In considemtion of th e issuance of th e Building Pennit. I agree thai I and my ugenls will comply with provisions of any federal. state or local law regulating ~te work nnd the Garfield County Building Code, ISOS regulations nnd applicable lnnd usc regulations (County Rcgula ti on(s)). I acknowledge that the Building Pennitmny be suspended or revoked, upon notice rrom th e County. if the location. constru ction or usc oft he slructurc (s) und fnci lity(ies). described above, nrc not in compliance with County Rcgu lalion(s) or any ot her applicable law. I h ereby grant pennission to th e Buildi ng O cpm1mcnt to enter the property, descri bed above, to inspect the work, I further acknowledge th at the i ssuance of the Building Permit docs not prt:ventthc Building O fiicial from : {I) requiring the correction of errors in the sub miunls, ifimy. discovered ufier issuance; or (2) stopping constnacrion or use of the stmc ture(s) or f.1c ility(ies) if such is in vio i:Hion of Co unty Regulation(s) or nn y other app licable law . Review o f this Applicali on, including s ubm.illals, and inspeclions of the work by the Building Depanmcnt do not constitut e an ncccptance of responsibility or liaOility by the County o f errors. o missaous or d1screpnncies. As the Owner, I acknowledge that responsibility for compliance wilh fedeml , state and local laws and County Regulations rest wilh me and my authorized agents. uacludang without ,..,,..;,, '"' '""'~""'''""· ""''"'" .... " ""''""· ~ '""''QG~~"'""'D4ZT' '"'"oT<cu e<~n;:;oo• ;:~R~ a_ y '2.-000\ OWN E~I GN..KT];KIE V '.--r --= DA TE ?/ ........., STAFF USE ONLY Specia l Conditions: Permit Fcc: Ma nu ho m e Fee: Mise Fees: r~4~.~s The following items are required by Garfield County for a final Inspection: l) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Depmtment and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all!BC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. VALUATION FEE DETERMINATION Applicant Sarah Lovatt & T im Boxle Subdivision Address C.R. 11 5, Glenwood Lot/Block tb.tce I ~ Date 3/25/2009 Contractor eo~s t ;+w-TvJo 1(ee. Finished (Livable Area}: Main sq.ft Upper 1320 sq.ft Lower 570 sq.ft Other sq.ftX $74.68 Total Square Feet 1890 sq.ft Valuation 141,145.20 Basement: Unfinished sq.ft X $41.00 Conversion of Unfinished to Finished sq .ft X $33.68 Total Valuation 0 .00 Garage: 75 0 sq .ft X $18.00 Carport: sq.ft X $12.00 Total Valuation 13,500.00 Crawl Space sq .ftX $9.00 Total Valuation 0.00 Decks/ Patios Covered 300 sq .ft X $24.00 Open sq .ft X $12.00 Total Valuation 7,200.00 Commercial Type of Construction: Occupancy: sf X sf X sf X sf X sf X sf X Valuation 0 .00 Total Valuation 161,845.20 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the propeiiy lines fi·om each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Prope1iies with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within th~envelope. Yes / 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes " 3. Does the site plan include when applicable the location of the !.S.O.S. (Individual Sewage Disposal System) and the distances to the prope1iy lines, wells (on subject property and adjacent properties), streams or water courses? Yes._-"'----- 4. Does the site plan indicate the location and direction of the County or private road accessing the property?. Yes ·/ 2 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this propetiy? Yes if Yes please provide a COPY. No _ __,._ __ _ 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other aget:;;ies Yes v 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes _ _,"'---- 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes .j No ' ____ _ 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes _ __,,._ __ _ No ____ _ I 0. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 'v/ 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes V 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes / 13. Does the building section drawing or other detail include the method of positive connection of all columns at/eams? Yes , 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes v· 3 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes ,/ No ______ _ 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes I/' No ______ _ 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes ·/ 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes V 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No ______ _ 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes -~--- 21 . Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes. __ .>L, __ _ 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Depmiment prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes / 23. Will this be the only residential structure on the parcel? Yes No lfno-Explain: _______ _ 24. Have two (2) complete sets of construction drawings been submitted with the application? Yes ./ 4 25. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes J 26. Have you designed or had this plan designed while considering building and other construction code requirements? Y es _ _,c_ __ _ 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes / 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Depmiment? Yes / 29. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes .,/ 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes V 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-50037 Yes V No ------ 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes yl 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes __ 'Y_ __ _ 5 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes J 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes V 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes / 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes / (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuanc.e of a building permit that you will be required to obtain a grading permit? Yes v 39 . Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes _--'L __ _ 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide wa!~~permit application will be accepted without such a letter. ,/·- Yes -~~..-''"" I hereby acknowledge that I have read, understand and answered these questions to the best of my abi}ISJ' . /! •.. 'I . ' ·' ov;;tf/ ~Date Phone: CfrO 6(8 019 I (days); Cft6 hi~ Q[C~\ (evenings) 6 Project Name: 60YLI-) LO~IT (2.E51YE'"-lCE ProjectAddress: l-0\ '"]). CDLJI-J\1 (.2.:]>. 1\51 G-L.E:~CvCOP Sf(li'!\.16-5,?:/60\ Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreqsfJan2009 7 11/14/2008 08:04 9706258627 GARCO ROAD 9~IDGE PAGE 01/08 Bill To: J)Kl UEW A i Garfield County P ef< ~ ~ ~ Road and Bridge Department P.O. Box426 Rifle, CO 81650 Phone~(970)625-8601 Fax-(970)625-8627 Invoice Driveway Permit Number: GRB08-D-122 Invoice Date: Anthony Ulwick P0Box3544 Aspen 11/14/2008 ,CO 81612 $75.00 per Driveway Permit. Driveway Permit Fee: ··-· ....... ,_. Total Due! Thank You! $75.00 $75.00 <'i. .k hv->L =~ DOLLARS THIS CHECK IS DEU/ERED IN CONNECTION WITH THE FOLLOWING ACCOUNT (S\ A.. --~-7~---·~---· .. --·· --.... -·------·-·-- 11/14/2~~8 BB:B4 9705258527 GARCO ROAD BRIDGE PAGE 03/~B 6) In the event it become~ neces.ary to remove any right-of-way fence, the posts on either side of the entrance shall be surely braced before the fence is cut to prevent •"Y slacking of the remaining fence and a \I posts nnd wire removed shall be turned over to the District Road Supervisor of the Board of County Commissioners. 7) No revisions or additions shall be made to the driveway(s) or its appurtenances on the right-of-way without written permission of the Board of County Commissioners. 8) .Provisions and specifications outlined herein shall apply on all roads under the jurisdiction of the Board of County Commissioners of Garfield County, Colorado, and the Specifications, set forth on the attached hereof and incorporated herein as conditions hereof. 9) Final inspection of drivewRy will be required upon tompletion and ~~tust be approved by person issuing pormit or repr .. ent.Uive of penon issuing permit. The inspection and sign off must be done prior to any CO from the Building and Planning Department being issued. 10) Contractor agreeS to all Provisions in Exhibit A. Special Conditions: l. Driveway Width-25ft 2. Culvert required? True Size: 12 inch by 30ft 3. Asphalt or concrete pad required? False Si•e of pad: 4. Gravel portion required? False Length: S. Trees, brush and/or fence .need to be removed for visibility? .False 6. Distance and Direction: 7. Certified Traffic Control Required? .False S. Work t,.one signs required? True I~ signing. this applic~tion and ~tpon receiving authorization and permission to install the driveway approach (es) descnbcd herem the Applicant Stgntfies that he has read, understands and accepts the foregoing provisions and conditions and agrees to construct the driveway(s) in accordance with the accompanying specification plan reviewed and approved by the Board of County Commisstoners. Signed:_~~ Anthony I Address: Z'l.YL C;2//S"" 6,/tA~S/:Jr~C!(.P Telephone Number:'--~3"-'-7.!.'l_-_.!.,/;::5<~fl:._'_o ___ _ Permit granted 11/14/2008, subject to the pro:>visions, specifications and conditions stipulated herein. for Board of County Commissioners' of Garfield Countv, Colorado: C!oJwwJ J - Representative of Garfield County Road and Bridge Signature 11/14/2008 08:04 9706258527 Garfield Application for Driveway Permit Pers"n Obtaining Pennit: Anthony Ulwick Application Date: 1 J/14/)008 County Road Number' 1 I 5 Distrkt: Glenwood .Pemtit Number: GRBOB-D-121 Termination Date: .1211412008 ln•pectot: Wyatt J(eesbery hereby requests pennis.;ion and authority from the Board of County Commissioners to construct a driveway approach (es) on the right-of-way off of County Rood..!.U. 88ft East of 9119 C.R 115, located on the Norlb side of road for the purpose of obtaining access to property. Applicant $Ubmits herewith for the consideration and approval of the .Board of County Commissioners, a sketch of the proposed installation showing all the necessary specification detail including: I. Frontage oflot along road. 2. Di~tance .from centerline of road to property line. 3. Number of driveways requested 4. Width of proposed dri"eways and angle of approach. 5. Distance from driveway to road intersection, if any .. 6. Size and shape of area separating driveways if more than one approach. 7. Setback distanee of building( s) and other struclllre improvements. 8. No unloading of equipment on county road, any damage caused to county road will be repaired at subdivision expense. 9. Responsible for two years from the date of completion. General Provisions 1) The applicant represents all parties in interest, and affinns that the driveway approach (es) is to be constructed by him for the bona fide purpose of securing access to his property and not for the purpose of doing business or servicing vehicles on the road right of way. 2) The applicant shall furnish all labor and materials, pcrfonn aU work, and pay all costs in con.nection with the constructi.on of the driveway(s). All work shall be completed within thirty (30) days of the permit date. 3) The type of construction shall be as desil!l'ated and/or approved by the BO$rd of County Commissioners or their representative and all materials used shall be of satisfactory quality and subject to inspection and approval of the Board of County Commissioners or their representative. 4) The traveling public shall he protected during the installation with proper warning signs and signals and the l!oard of County Commissioners and their duly appoint~'<! agents and employee shall be held hannless against any action for personal injury or property damage sustained by any reason of the exercise of the Permit. S) The Applicant shall assume responsibility for the rem1>vat or clearance of snow, ice, or sleet upon any p(>rtion of the driveway npproach (es) even though deposited o.n the driveway(s) in the course of the Cotmty snow .removal operations. I I I I I I 11/14/2008 08:04 9705258527 Specifications 1. p.. driveway approach is understood to be that portion of the counl)l road right-of way betweend the padvebumcnt edge and thel'roperty line that is designed and used for the interchange oftrafftc between the roa way an a tttng property. 2. At any intersection, a driveway shall be restricted for a sufficient distance from the intersection_ t~ preserve the normal and safe movement of traffic. (It is recommended for rural rC-•idence entrances that a mtmmum intersect1on clearance of 50 feel be provided and for I\lral commercial entrances a minimum of I 00 feet be provided.) 3. All entrnnces :ond exits shall be so located and constructed that vehicles approaching or using them will be able to obtain adequate sight distance in both directions along the counl)l road in order to maneuver safely and without interfering with counl)l road traffic. 4. The Applicant shall not be permitted to erect any sign or display material_, either fixed or movable, on or ex tending over any portion of the counl)l road right-of-way. 5. Generally, no more than one approach shall be allowed any parcel or property the frontage of which is less than ov.c hundred (100) feet. Additional entrances or exits for parcels having a frontage in exce"'' of one hundred 100) feet shall be penni tted only after showing of actual convenience and necessity. 6. All driveways shall be so located that the flared \'Ortion adjacent to the traveled way will not encroach upon adjoin.ing property. 7. No corTITilCrCial driveway sball have a width greater than tbirty (30) feet measured at right angles to the centerline of the driveway except as i11creascd by permissible radii. No noncommercial driveway shall have a width greater than twenty (20) feet measured at right angles to the centerline of the driveway, except as increased by permissible radii. 8. The axis of an approach to the road may be at a right angle to the centerline of tbe county road and of any angle between ninety (90) degrees and sixl)l (60) degrees but shall not be less than sixty (60) degrees. Adjustment will be made according to the typ¢ of traffic to be served and other physical conditio.n.s. 9. The con.struction of parking or servicing areas on the cou.nry road right-of-way is specifically prohibited. Commercial <:stablishments for customer vehicles should pro~idc off-the-road parking facilities. 10. The grade of entrance and exit shall slope downward and away from the road surface at the same rate as the normal shoulder slope and for a distance equal to the width of the shoulder but in no case less than twenty (20) feet from the pavement edge. Approach grades arc rc_<tricted to not more than ten percent (I 0%). 11. All driveways and approaches shall be so constructed that they shall not interfere with the drainage system of the street or counl)l road. The Applicant will be requ.ired to provide, at his own expense, drainage structures at entrances and exits, which will become an integral part of the existing drainage system. The Board of Co\11'11)1 Commissioners or their representative, prior to installation, must approve the dimensions and types of all drainage structures Note: This permit shall be made available at the sif.e where and when work is being done. A work sketch or drawing of the proposed driveway(s) must accompany application. No permit will be issued without drawing, blueprint, or sketch. 11/14/2008 08:04 9705258627 GARCU KUAV ~KlUb~ Nov 06 08 09:10a TWO TREES CONST 970 38~ 2240 G.QRal ROAD BRIIJGE l~/29/2e~a B9:29 970&259627 Driveway Pennit Cheek OIJFo1111 1. PmnitO"""": I f\tJf\-IOtJY \) L LJ 1 cJ( :!. Address: I fl. a. e¥35ft ('lt>f§iJ ,(0 ~[61'Z. J 3. City: Carbondo.\e31623 0 Glollwood SpringS 81601 lgj NewCastle816470 Sih81652 o· Rine316~0 0 .P .. achut~ 81635 0 Other '-----;::==:::;::===: 4. PIJoneNo:§¥0 Bl!iCf-zz'fCll F*>CNo: h::;c 3£42."Zt:te! s. Co1m!Y Rd. N o:l I I 5 l 6. Nm~:St Jnttco:<:tion o~ l"f I 1a. covio.l17 0 1 f 5 l 7. Dii'UIICC from Int. ~ I "& t>r\: I 8. Direction. from Int. or alldre<o: N 0 E ~ S 0 W 0 9. Sideohuad: N ~ E 0 S 0 wO 10. Width of driveway: 30-foot 0 40-!oot 0 100-fool 0 Olher:l ~ 5f:1" 11. Culvert rcqui~d: Yes ~ No O 12. Site of cuLvert required: 12-incb !X!tS•inclt 0 18-ii)Ch.· 0 Other: 13. Length of culvert ~uired: 30-foot 12{1 40-foot Qothcq j \4. Asphalt or coocretc pad rcquiml: Yes 0 No ~ IS. Size of pad; 30.foot wide X l()..foot lon~ X 4 inches thick: Yes 0 ·, 40-foot wide X 1 0-foot long X 4-inc:he< thick: Yes 0 100-(oot wl~cX lO·f<>ot long X 4-inches thick: Yes 0 Other: p.2 PAGE 01/04 11/14/:1_008 08:_04 970&258527 NOY 06 09 DS:!Oa 10I29tzaoe e~:29 TI.IO TREES CONST s7e~:IS9617 UARCU ~UAV H~lVb~ S70 394 2240 1,1PRCO ROIID ~IOGE 1.6. Gravel portion required: v.,. 0 No [K! 17. Lentfl'>Dfgrnvelportian: 40-foot 0 SO-footQ 100-fool 0 18. T r«s or bto.osh romoved for vlsilrility: Yes IZJ No ~ 19. Distance and direction from drivcw;.y to be re.,.oved: 20. Dri"""'l'y must be no more than 3% $lope awBJf Dmn CDUllt)' road. 21. Dri"e mu~t be COIIStructed so no drlrihll!jt' accesses CI>Lmty road li'om driVeway. 22. Ce~lied traffic conllol require<J: Yes 0 No g)_ 23. Work zonesignagc only <eqllirecl: ~~No 'jY 24. Stop sian r<quitcd at cnttanee lo County Rd. Yc< 0 No ~ 25. ln.•pcction of driveway will roquired upon completion and muot be approved· by per.;ao i5Suing permit or Npresentative of perscm is,Wng .penn;t. 26. Per5nnRequestingP01T1it: /GA~'( F'AL'J>A<;;Z... 27. Person i$ttin.g pennit: 28. District permit issued in: 29. Dote c:IIecklist complcted:jL.. -~~~~...:.~....L/_o...;!J_~--------l IAI.:'II:. tlbl oo p.3 PAGE 02/84 11/14/2008 08:04 9705258527 GARCO ROAD BRIDGE NOV 06 08 09:l0a l0/291206g 69:2, TWO TREES CONST 970&258&27 970 394 2240 ~ ROAl> SRIDGE 80NIJ) OF c::Olll'U C:OMIIISS10NJ;RS OF GI.Rli'IBLI> COIIIITY ~T~FICA~ION ~ AFFI~VIT RBGARI>XNG Xt.LEGAL ALIBIIS The Cont.ract:or. whose na.me and. signatureo appearg below. certifies •nd agrees as follows: 1. Xhe contractor shall comply with the provisions ot C.R.S. 8-17.5-~ol'et seq. The contractor shall not xnow1ngly employ or contract with an illeg~l alien to perform work for the aoard of County Commi$sioner$ of C.arf;i .. ld county. col oracle;> ( '"BOCC") or enter into a contnct with ~ oubcontractor ehat knowingly eMPloys or contraetG with an ille~al alien. 2. The contractor represents, ~rrants, and agrees that it ha~ ve~iEied chae it does not employ any illegal aliens: that it has participated = attempted to participate in the aa~ic Pilo~ Employment Verif.ication Program administered by the S<>c:i<>l Secu:ri~y Admini~t:ration illnd Department. o.t. Homeland Security: and otherwise shall comply with the req<>iremomt,. of C.R.S. 8·17.5-102(2) (b). 3. The contractor shall comply with all reasonable requests m,.ae in the course,;~ an iflvegtiganon under C:.R.S. S-17.5- lO~ by che Colorado !)epartment of Labor and Employment. lf the Con~~ac~or ta1ls to comply with Dny requi:remenc of this provision or·C.R.S. &·17.5•101 P.t seq., the QOOC may te~inate wor~ ~or breach and the Contractor shall be liable for actual and consequential dam~ges to th~ St.:1tc. 4. If the Cont~a~tor ~so ~ole proprioto~. the under~igoed her<>l>y swears or affima under penalty of pe~jury under the laws of the State ot Colorado that (check one), -I om a United s~~tes citizen, o~ I am a Permanent Resident of the United States, or ____ t am l~wfully present in the United States pursuont to Feo"r~l l.;>w. l understand that thia 9~o~o statement is required by law bec:~.usa l. am a aol!::! p.-oprietor e:ntering into a contract to per!orm work. f"r the BOCC. l understand -.:hat: st~c" law requir£s me to provide proof eh~e I am lawf~lly present in the vnit~d States prior to starting work for the BOCC. 1 PAGE p.4 PAGE 83/04 07/08 Nov OS OS 09:loa 1 Of29/2a0B ~9: 2'il :::J/t:JOL:::JtiOLf TWO TREES CONST 970&258&27 970 384 2c4o GARCO ROIID l!RlDGE £urther acknowledge that I will comply with the ~equirernenta of c.R.S. 24-?6.5·101 et seq. and will p~oduCP. the x-equired for"' of. identification prior to starting worl<. l acknowledse that making a false. fictitious. or fraudulent statemen~ or representation in this sworn affidav~t is punishable under the criminal laws of Colorado as perjury in the second degree under C.R.S. 18·8- 503. CERTlflED and hGREED to this ~ day of 200.£_. . p~,.,.;t NIUII&tr:. _______ _ b/tibiiA co -~"'J'fzss­ PSlN or SOcial Security t-'Abt. l:ltl/t:lt:! p.5 PAGE ~4/8' Parcel Detail Page I of3 Garfield County Assessor/Treasurer Parcel Detail Information Asse~sor/Treasurerl'rQJler!y_Search I Assessor Subset Query I Assess_oLSalesSearch Clerk& Recorder ReQeptio!LSearch Bi!sic Building Characteri_stics I Tax Infmmation Par_~el Detail I Value Detail I Sales Detail I Residential!C_ommercial Improvement D_eti!il Land Detail I Photographs I Mill Lew Revenues Detail I Tax Area II Account Number II Parcel Number II 2008 Mill Levy I I 005 II R041020 II 218736300156 II 52.848 I Owner Name and Mailing Address !BOYLE, TIMOTHY & ILOV A TT, SARAH IPOBOX3544 IIASPEN, co 81611 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:36-6-88 DESC: PARCEL In, A PARCEL OF LAND SITUATED IN THE ISE1/4 OF SEC 36 LYING NL Y OF THE INL y ROW OF CR 115 PRE:R007347 IAND/THRU:T TO:R007349 BK:1207 lPG: 199 BK: 1153 PG:991 BK:0969 jPG:0180 BK:0392 PG:0359 IRECPT:762415 BK:1802 PG:141 jRECPT:698268 BK:1802 PG:138 IRECPT:698267 BK:1561 PG:45 IRECPT:646592 BK:1553 PG:906 IRECPT:644463 BK:1531 PG:369 IRECPT:639130 BK:1523 PG:194 IRECPT:637445 BK:1459 PG:155 http://www.garcoact.com/assessor/parcel.asp?Parce!Number=2187363 00156 I I 2/23/2009 Parcel Detail Page 2 of3 IRECPT:625306 BK:l243 PG:518 I IRECPT:578841 BK:l207 PG:l99 I IRECPT:569287 BK:0746 PG:0467 I IBK:0723 PG:0753 I Location I Physical Address: llcARBONDALE I I Subdivision: I I Land Acres: 1135.427 I I Land Sq Ft: llo I Section II Township II Range I I 36 II 6 II 88 I 2008 Property Tax Valuation Information II II Actual Value II Assessed Value I I Land: II 26o,oooll 75,4001 I Improvements: II Oil 0 I Total: II 26o,oooll 75,4001 Additional Value Detail Most Recent Sale Sale Date: 115/12/2006 Sale Price: 11295,000 Addi1ional Sales J:)etail Basic Building Characteristics Number of Residential 0 Buildings: Number ofCommllnd 0 Buildings: No Building Records Found Tax Information http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=218736300156 2/23/2009 Parcel Detail I Tax Year Transaction Type II Amount I I 2008 Tax Payment: Whole II ($3,984.72)1 I 2008 Tax Amount II $3,984.721 I 2007 Tax Payment: Whole II ($4,007.04)1 I 2007 Tax Amount II $4,007.041 I 2006 Tax Payment: Whole II ($10.44)1 I 2006 Tax Amount II $10.441 I 2005 Tax Payment: Whole II ($10.50)1 I 2005 I Tax Amount II $10.5ol I 2004 II Tax Payment: Whole II ($10.66)1 I 2004 II Tax Amount II $10.661 MilLLeYY_R~-"~n1l~~-Petail IPp_QfPage AssessQr Database Search_Qptions I I~as\Jter Database Search Options Clerk & Recorder Database Sean;h_Options Qarfield County BomePage Page 3 of3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright© 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http:/ /www.garcoact.com/assessor/parcel.asp?Parce1Number=218736300 156 2/23/2009 BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Date Issued -~3~-'-._.,lli,.._..""O-___q_._ _________ Permit No. AGREEMENT \' 1-le\ In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the-zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Useblf wj COJered pmos ~ ~ht d ¥"~ AddressorLegaiDescription Cf<. 115 1 6\NS Ownerl,oVod±1~'Ba'6~;Jlt\.L Contractor LlYflS Coos\:. Building Permit Type }?est derrtjS'i This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway lr 9'-o?~ tf//1&/Z. ctif 8-:J -:Jot o '777e.J._ £ ... w7Th-~y OK.. Foundation I Grouting Insulation 7~')..g-/~ Underground Plumbing Drywall o-J-/0 7<~ 9-J,( 'V"r.P:YHZ Rough Plumbing Elp~Fi~y s~~~ ~7F:tor) 7-;;_;;-;e; 4 (Prior to Final) Rough Mechanical Septic Final S--/'f~o'f-9//4 -;.;,' :!""'"'Y..oc 7'~ :>-.=1?-t'o~ -;9_ L' /2 '"~-:> Gas Piping (/ V' FINAL //-1-10 ~~ 7-;;..3-,1'0~ Electric Rough (by State j/eror) (You Must Call For Final Inspection) {!I-o I'-/.!rF-1 /l I 0 (Prior to Framing) Notes CA77! 'T-/'7-Io oK 0"11. Framing 7~,;~,(; -/0"7/112.. (to include Roof in place & Windows & Doors installed & Firestopping in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970-384-5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ~:::ovE~ J.lo.Dq ByEJarWl/ ~ PROTECT PERMIT FROM WEATHER~ (DO NOT LAMINATE) 15'-1 " jTI I : T-1~ +-----+-~-~ I I I I I I I I ~ I ~ I I I I I _____________ _l_ TP 100'-6 Tf Cl1 '-1 1/2 ----~-----------------~ I ~ TW 101'-10 1/2 Tf CICI '-4 TW 101'-10 1/2 Tf CICI '-4 ~ _, 10 0 -· ~ PARTIAL FOUNDATION PLAN • 1/4' = 1'-o BUILDING ELf:\ =SITE ELEV JOB #1003 BRIGHT ~.....___~ & ASSOCIATES 27.4363 office • 970.927.3039 fax Ave., Unit E • Basalt, CO 81621 ISSUED : 01/21/10 DRAWN BY: MUP CLARIFICATION SHEET: BOYLE RESIDENCE G2.1 GARFIELD COUNTY, COLORADO OF: 3 ~ IOxo3 2x8 P.T. LED5ER 111 4-16d NAILS @ EA. SlVD (16" O.C . MAX) PACK 1"£6 SOLID TI5HT TO FLAN&ES PARTIAL UPPER FLOOR PLAN ALBRIGHT ~llli.:..:.._~ & ASSOCIATES .4363 office • 970.927.3039 fax ISSUED: 01/21/10 8 1/4': 1'-o DRA WN BY: 0 2 Park Ave., Unit E • Basalt, CO 81621 MIJP JOB #1003 CLARIFICATION SHEET: BOYLE RESIDENCE G2 .2 GARFIELD COUNTY, COLORADO OF: 3 ----0------+---------~6x~I2~D~F~#~2----------++~ 2x8 P.T. LEDGER D 4'-0" YV 4-16d NAILS @ EA. STUD (16" O.C. MAX) V'll0x33 PARTIAL UPPER FLOOR PLAN BRIGHT ~~.,3& ASSOCIATES ·4363 office • 970.927.3039 fax ISSUED: 01/21/10 • 1/4' = 1'-o DRAWN BY: Ave ., Unit E • Basalt, CO 81621 MUP N JOB #1003 CLARIFICATION SHEET: BOYLE RESIDENCE G2.3 GARFIELD COUNTY, COLORADO OF : 3 T· ,...'f:1~'ffD Y2..uql}f;;t p(J,-~ ra~l '<Ll-x:1utsiof'\ P .. 1 "'J -¥ 1 1 2. 6 I GARFi 'LD co~~TY 0LJr.JEt2~ -1-..0vft/T 5 A«.AH (6o'(t-6 til"'\ BUILO/tr}&PLANNING f' 'YJ>P-Ess -88 -r-7-cou ~~ Y rZ:D 11 5 G,. F~c.oaa:D s?l( rfJ 6-5) COEr 6o ( ·Tr-~ . -97-o 6U) "! 0 5 ~ (T 1 fVl 13o yLE J BOYLE SITE PLAN SUR V EY A P ARCEL PROPERTY DESCRIPTION PARCEL P A PARCEL OF LAND SITUATED IN THE SEI/4 OF SECTION 35 AND THE SWI /4 SECTION 36, TOWNSHIP 6 SOUTH, RANGE 88 WEST OF THE 6TH P.M .. PART LYING NORTHERLY OF THE NORTHERLY RIGHT OF WAY OF COUNTY ROAD NO. 115, MORE PARTICULARLY DESCRIBED AS FOLLOWS : BEGINNING AT A POINT WHENCE THE CENTER OF SAID SECTION 35 BEARS S87'20'59"W 254.72 FEET; THENCE N87'20'59""E 2538.82 FEET TO THE EAST 1/4 CORNER OF SAID SECTION 35; THENCE S49'31'46"E 876.38 FEET: THENCE N83'56'06"E 173 .53 FEET; THENCE S76'12'58"E 612.25 FEET; THENCE S84'33'13"E 75.63 FEET; THENCE N88'24'10""E 97.45 FEET; THENCE N65'13"55"E 86.99 FEET; THENCE S50"38'48"E 790.80 FEET TO A POINT ON THE NORTHERLY R~GHT OF WAY OF COUNTY ROAD NO . 115; THENCE ALONG SAID RIGHT OF WAY THE FOLLOWING 8 COURSES \AND DISTANCES: 1) S59'28'08"W 47.43 FEET; 2) S56'09'49"W 115.91 FEET; 3) S54'12'16"W 293.78 FEET; 4) S49'14"01"W 255.27 FEET; 5) 211.16 FEET ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 158.33 FEET THE CHORD OF WHICH BEARS S89'34'39"W 195.86 FEET; 6) N50'42'06"W 231.83 FEET; 7) N43'13'29"W 89 .32 FEET; B) N64'52'09"W 16.72 FEET; THENCE LEAVING SAID RIGHT OF WAY NOO'OO'OO"E 648.53 FEET; THENCE N80'55'05"W 3861 .24 FEET TO THE POINT OF BEGINNING. SAID PROPERTY CONTAINS 35.427± ACRES . COUNTY OF GARFIELD STATE OF COLORADO GRAP HI C SCALE ( IN FEET ) 1 inch = 200 ft. OF PARCEL D, LAND IN SEC. 35 AND COUNTY OF GARFIELD, FOUND REBAR .1: CAP P.L.S. 19598 ----------N87'20'59"E _ ----- ----- - NB7:,j0~"·.£E-<8"0:::::..:------ - ---- ----- -2538.83 ' 54.72' - - -FNO. 2" ALUM~ - ----CAP P.L.S. 31944 I FN D. 2" ALUMNI CA P P.L.S. :3 1944 - ------------ NOTES & LEGENDS: ·------ -BASIS OF BEARING IS THE NE AND SE CORNERS OF PARCEL D P.L.S. 31944 AS SHOWN. -NO TITLE COMMITMENT PROVIDED -THIS DOES NOT REPRESENT A TITLE SEARCH BY THIS F/R ,V OR SURVEYOR . ® -INDICATES FOUND MONUMENT AS DESCRIBED. ~-INDICATES FOUND REBAR & PLASTIC CAP SSG P.L.S .. 31944 UNLESS NOTED. I><J-INDICATES FOUND WATER VALVE. ~-INDICATES FOUND POWER POLE. -ELEVATION DATUM IS HAND HELD CPS NOTE: THIS TOPOGRAPHIC J/AP COJ/PL/ES WITH NATIONAL MAP ACCURACY STANDARDS FOR TOPOGRAPHIC MAPS . WHERE CHECKED 90" OF THE POINTS SHOULD BE WITHIN f/2 THE CONTOUR INTERVAL AND WELL DEFINED POINTS SHOULD PLO'fTED WITHIN t/50" OF THEIR TRUE POSITION. CRITICAL DESIGN SHOULD BE BASED UPON SPOT ELEVATIONS , PLEASE CONTACT THE SEXTON SURVEY COMPANY FOR THIS SPOT ELEVATION INFORJIATION. NOTICE: ACCORDING TO COI.ORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SU RVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVERED SUCH DEFECT. IN NO EVENT. MAY AN ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED A/ORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. ---------.ot:!lBO•ss ·os··" --4 8861.2<~'"---------------- LINE TABLE ..... _ 128 WES 3 , STREET RIFLE fO . 8 1650 625-,71 ~ g't4700 ' .... 29 PEAKS, 3 6, T . 6 S. , R. 8 8 W. 0 F STATE OF COLORA DO THE 6TH P.lvf. S87'26'12"W .... .... -------------... ? -----...,.. 343.48' ------------/ -------------/ ----------/ 0 ------ I .~,1 il 0 • o"' ... ~I (Q I BLOWUP 1"=20' .... .... PARCEL D SURVEYOR'S CERTIFICATE / / / / / / / / / / / / GRAVEL ROAD JO . NO.: 07057 DATE: 04/16/0? DWG . BY: KS CK· BAS REV: 1 of 1 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT --;-· \ 4~ ~---,? D<J ·?--2/~_QG 108 Eighth Street, Suite 401 Glenwood Springs, Colorado 81601 Phone(970)945-8212 1 _:::r. I ::;;: ~ -lf~ I INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY SYSTEM DESIGN / 0 cJO Septic Tank Capacity (gallon) /v/)'1 Other ' Permit 4625 Assessor's Parcel No. r:p 11z~1 This does not constitute a building or use permit. Phone lQ I 'i! q em J 5'" Percolation Rate (minutes/inch) Number of Bedrooms (or other) 3 ;--ry~ '}&,_4-",":f-"'- Required Absorption Area-See Attached 1/! '6 4¢'v<-<v'-<'/~!;; . /-" 0 _7_/A<~ d[ 4 ,,0 ¥' 3¥' ,_. 1.-r 9 A4'•H_...,; -fee/ /n ..A'·"-'2-v0"'' i . -;/ // /t Special Setback Requirements:/?~ --J,~~.£1':•EN, 4;.~ {? &<§ 7 3 .b-7>~ /.I Date [_ 6-<' 't !~ector 7 724~/-;::PJ;c.?-;c·:~ FINAL SYSTEM INSPECTION AND APPROVAL (as installed) t/Y'Jk--:C /2'(/':VL;,,7 , rd:.ej?w-7;, F- Call for Inspection (24 hours notice) Before Covering Installation ~ 8-""''/'-cc~-2 -------' System Installer (/..._)~ 73. -&. Septic Tank Capacity 9z~/Y0-<::.<?-/If' OcJ om-L . (,) Septic Tank Manufacturer or Trade Name _,<,9;'--"'~""---'"""c"-/.:::&"'~""'""'------------------ Septic Tank Access within 8" of surface--;~"=--~------------------- Ab t. A Lj' c-;-/, sorp ton rea ---'--''""vu"""C'"".:a'-'-v.::o-c../'--="=·-•o..' ------------------------- Absorption Area Type and/or Manufacturer or Trade Name C.Z 1-<:/ __ :\ b -Jl I 0 Adequate compliance with County and State regulations/requirements--------------- RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine-6 months in jail or both). White-APPLICANT Yellow-DEPARTMENT:.