HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-01-17-4564 Kendrick Development lronbridge PUD, Phase Ill, Lot 30 1723 River Bend Way-Glenwood Springs, Colorado 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC). 2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY BUILDING REQUIREMENTS. REDLIN ED NUMERICAL NOTATIONS ON PLANS REFER TO ANNOTATED ITEMS ON THE ATTACHED "RESIDENTIAL PLAN REVIEW LIST". 3) A LOT IMPROVEMENT CERTIFICATE SEALED BY A COLORADO LICENSED SURVEYOR IS REQUIRED TO VERIFY THAT STRUCTURE (INCLUDING ROOF OVERHANGS) WILL BE IN COMPLIANCE WITH ALL BUILDING SETBACK REQUIREMENTS. 4) INSTALLATION OF STRAIGHT-SHAFT DRILLED PIER FOUNDATION SYSTEM TO FOLLOW RECOMMENDATIONS CONTAINED IN GEOTECHNICAL REPORT PREPARED BY HP-KUMAR DATED JANUARY 6, 2017 (AND PRIOR REPORTS DATED 2/8/16 AND 1/6/17). SOILS ENGINEER OF RECORD TO BE PRESENT AT JOB SITE DURING PIER DRILLING TO VERIFY THAT BEARING STRATA HAS BEEN REACHED AND MINIMUM REQUIREMENTS CONTAINED IN THESE REPORTS HAVE BE MET. PROVIDE SOILS ENGINEER'S SEALED APPROVAL REPORT FOR CONCRETE PIER FOOTINGS AT FOUNDATION INSPECTION. 5) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.