HomeMy WebLinkAbout5797GARNEL/J CVUNIY
DU!L/JJNG, SAN/TA 7TON nnd PLANNING DEPARTMENT
I 09 Kth Slrccl Suite ]0]
(ilcawood Spring~, Colorado 81601
(303) 945-8212
0158 Coyote, Aspen Glen, Lot D-40, Carbondale Job Address __________________ _
No. 5797
Nature of Work_~B~u~i~l~d~i~· n=g~P~e~rm=i~· t~-----------------------------
1-1:-ie oflluildin'""--'D"1"1p;..l"e"'x"'-/-"2'--"'D"o'-'u"'b"'l~e--"G"'a"r'°'a"g'-'e"'s,.__ _________________ _
Owncr ____ ~A~&~M,__,B~u~i~·"l"'d~e~r~s'-----------------------·--------
Contn1ctor __ ~Own=,~e'=r _________________________________ _
A111ounl of Pcnnit $ 4, 911. 22
Permit: 2976.50
Plan : 1934. 72
Paid $1876.71 2-9-96
Da!c February 26, 1996
S. Archuleta
Clerk
BUILDING PERMIT APPLICATIL
OAR~El.D COUNTY, COLORADO
Apnlioant to comolete numbered soaoes on/v. PERMIT NO. $19 7 PARCEUSCHED NO.
3 CONTRACTOR A .f fi1 ~v 11,.1) F!R ? ADOREss V If ,-(.. Co PH, LICENSE NO.
4 ARCHITEcroR DESIGNER £, BA e. 1 '..~: A~ ADORES• t: II ti> APDS <!!u PH LICENSE NO.
.1.1,;;-! ·~· PH. '7"), ,J;rl !JCEf\'SE NO.
6 S.FDFOUJLOING J.i.1ts 9n iii. sronor 2B ~A-'2.. ,0 H[IGJIT 24'-lo NO orrLOORS z..,,,
1 usEoFBUILDING Rc:5 ; o ~1J tip..,__, o~l{~,,,~IP 11111v1~8-c1P1?Jt?1.1tJ -=-#s{!) if:.f:," i11i /l-!..__j....:.......:.....:.:.:..:......:.......-:.;.::.:...::....:...::..._.:.:.....:...-.'... ____________ ...j!:::.:..::0:.:.:....-:.-.'...C:..::C:..:-=-<"'"-' i ~ ~-!..!..:. ~zi-l---
lf-'8"--t-c.:.":..'.:.'.:.o':.."'°.:.:..".:.' __ ::.:_.t.8;1.:.:....:.":..A.:.0.:.0..,IT,;IO<"N_n:,_A:,_L-TE-:,R_A_TJON.:.:.. .. ":.."_E_Pl'J_R..:.a:..M.:.0.:.VE.:..:.a:..R_E:,_M.:.O.:.VE=--4....!:G::..:..11.:.'l..:.:.l'f:....::6-_J'C_..;,'1:.."..;~.;'1-="~r:,;;:.:;;8;!f.,i •. '"riv /C .t: 'i '/.£;1 '.(j),~ $.tlJ!-'
1 1-'9'--'--o•_•c_"_"_vvo_'_"......:J:;.~).c.u_f_'l_f:_x_, _../!c,..)c..~~~-' _1 _0_l_=>..;.f-.-_
1
_C_6 _______ ...;,;T'-o_r_/i_<-_S.-'~-'-. "'FT.-"-. _rt.;J.~:"',1 _.t/-'---""""'---l II
wzsrvnr.-l/fTS'4',7.J~J:J./!!11f;TOl'ir ~3,1.S"l· sa. FT. TOT/1L-Vl/l.V/lT/01-' ='?f5;;;t DJ ,:.1>')1 .
1 Q ( GARAGE') SINGLE (oo~~~o/)l 2 CARPORT SINGLE DOUBLE
DRIVEWAY PERMIT ON S!TE SEWAGE DISPOSAL PERM!T SITE PLAN
11 VAlVATIOH OF WOAK: $ ADJUSTEOVALOS;? /(J3g.'J? PLANCHECKFEE~ • 1 :·' .. :.~ PERMITFeE']J''.:;rq 7:),.. '° (\"II
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, Nor R-·iREn
VENTILATING OR A!R COND!TIONING. 11-....e.s'"''"''"'-''""A"'""''ov=""-'--'l---'R"''"'O\J""""'---l---"'"'eo°'=:."'=' --+--"=.::·=-=---ll
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED JS 7-0N!NG
NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTR\JCTION OR WORK IS SUSPENDED lt;~;;;:::::::::~~~~;=t::::::::::::::::::::::::t::::::::::::::::::JI OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS I.
COMMENCED. HEAL TH DEPT
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPUCAT!ON ANO KNOW l'V~;ll?I( £) , J' )', ... rt-r..-il
THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES l..".F~IR_:E£DE:!PT::'.:_. --~~·£}. n .. ¥~',-i~'.£1~ ;,., =i:'.f:~r~~!lfv~-u.~~~1:uv-::::.:~i::··f':-.:J'.:::~;kjv~~' ~· ~I
GOVERNING TH!S TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED _,.
SOIL REPORT H~RE!N OR NOT.~· !~E~GRAN ING OF A PERMIT DOES NOT PRESUME TO GIVE
L AL LAWJ IJfl;~~TlN C~TRVCTlON OR THE P~R?<J~~E OF SETBACKS
AUT ORITY TC VlOt:::ATC, OR ~9:2_ THE PROVISIONS OF:'lANY OTHER STATE OR
c ,_rrv"'J<1 r / '" , , ra.i.> z, 7 / q ~ 11-------t------+-------+-----~1
FLOOD H/\ZARO
. t Sig
1
narure ~f.~er, Contrac1or or nu\horiz.z-d~.~.\):ltl_vin.sµ,!'.'~d ~J.9;~~;~tood nolic?'ob
/ '~ (/ )1 ~ /.. --7 Y <);,,!//')// Z/2&. "'/&
Buildi'ng Department Approval6'aY f'f PlannlnQ0r;paJ?ment Approval/date
MANUF. HOME
OTHER
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT O~ THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS A"lD OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003
(pd 1 /,S7 / b. Z!
I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE ~<IN~l~T~IA~L ____ ~l
dl-9-'7?
----------------------------···---·-------··-··----------------------------------------~-92";4-fL.1__,y_Q --------------
___ --_ _--_:--:=--=---==-===-==--~===-====~------===-===-=z~j4~=~~:~~--~=~~--~==~
--·---··--··--···-···--· ------.-·------_____ ,, _________ _
---~----..-..-------.
----------·-··-···--------------·-------------------------------------Jf?'-l_l_Lg_ ~-----------------····-·----·--------
-------------------------~.;...-~-=-:J.=i_. -"' _v -~----------·-··-----·----------·-·---·····------------········-------------····--······-------------
----------------__ Jf.11_$__4__,_ZJC _________ ----f4-7 £11-L?_)_:_ ___________________________________ _
=-t~--;~$_7'_ __ ==--L~~=~~~--·=0
__ -!~lf!!._=~=~: __ ~~-~-----=-~-=:-:--~==---=== :-:---==--:====-
·······---J '1~4~S6_. ,------... __ ____ ___________ _________ _ _____ _
-r~ tvµ:f 3 :J. J .1. £a -' ---' -' ' - -. -----· ---;·--------· --· ·---, .... -----------·-·----···· ... _._, .. _________________ ,.,_, ___________________ ·-
·---··----------·-·-------____ ,, __ ____,---·---·-·--·-----·-----------·--·---.. ------·--------·--·-------·-·------------------·--··-··-·--·--·--·-------------·-... ·-···-·--·--------·------ ---------------··-·----··-----
·····--·-···--·--········-Q:r~:+<;J;:r~ _/Jk~-·-·---· -·-. ---·
w'~·· ~
--~-~--------;--·--····--·· _____ ·; .... ~ ..... ~ ..... &>,Ol_ij.~_1 _
····-·----4.()_~Jfx..S'LS:.. _____ ~ 24 Lz~_'!.._ ... ~ . . .. r 1 1 <t .~ ·······-··-
______ {~'4.f! -.. __________ jj 2._,(J__(J_~· ..... .s±ift.t/(o---~-'!-~_;,~ ------···--
} i .5')< HI jt; t;.. 66 Ft' J1.J'XIJ,J.:z ~5~ I ·······---·--····-···-·····-·······-·-····-····-·-----·-·---·---· . ---,--.. d.~----= I,;,~ ----
. ---·--·----··-___ .... _____ ·-·-_.J..)>:9 6-:,z.£ &?__···-·-· _ WA ..:jlr .. -··-....... _____ -··
li4A-§-C:!Jt[J_W~)_LJZ_,i~_'xL2?JIO._~ 0 ~ --~ ... ---=-hi H------------·--
e~~= ·---~£':_~:~-=~~--_?!_=~-JL='
---~:.~~.·~-;---=~ -;:~-",;~ -· :7~~;~;~,;~ :--:_ --. -
_JJ 'J. ,J.J -::::. .. -_). __ 7 :J J::t • ----3;.k'f 1__._:;; _ -. -----
------------·-------- ------·-1 ~-] ?t.1 p. I ----·---,f,f~;r ____ --a ... 7.£~t._0_(:(' .
•Jv~-~ ---=~: .... ···--------····----===~--·-==~--···~-~=.-~~ .... ==-=--······.-..==:-===--··-·--·· -·················· -····
. __ ;Jk__-S_'J,;I._3..r ................ J..74._i'_.4._._.7_.)~ '= I ------....... --·-·-·-· ---·--·····-------
.. _ .l.J'.i...£_2.J_$.._J __ ? ..... ___ J ;if_ ~~2:_.f".~' -·· --_-r:;-1-Jtt~I.-.......... ---·-········--------
1.t I )(JI, I -__ -=: t 'f'" d p. I --]6~ (, 0 ~
-:;, & ;;. I O D W ~ . i 'J.J , ~ t; P.
-----------------·-----·-
___ --. , ... ' ·.·· ~~-------_j1Q£1'.. 4_~_: _______ ----······--···-···------··················---------------····--
. ___ 11.'£xJ1'.->---··-_L~ Jt 1, .56 ".' ....... ---:i:Jkld2/~---__________ ...... ___ _
-·-------------_ l:i-:3 Z 7. So J:l' ~ Cf:Z.D
-£~ ~L ____ ------=-~j~~~~-~-~-== :·--:=~=-=~~==---='~ -_-.-_:·:=-~-~ -=--=-:
. I 9' 5' (pJ o . :=-~~~:-~~~-~:~ :=::~-==-~--~';~f}~,~~=~--~---~--,;~--c=-~-=---pj-zg__j ·~'-J,~O·--=·'-
____________ --~-----------------· --------·· -~~--.----··---····---~-O_)_ __ lj_2_~----··--
February 21, 1996
Dale McKay
2633 Kinnickinnick Road #E4
Vail, Colorado 81657
Re: LotD40
Dear Mr. McKay,
ASPEN GLEN GOLF COMPANY
I have calculated the available fire flows from the water system schematic as provided by Schmueser
Gordon Meyer in the area of Lot D40. The available fire flow is approximately 2,675 gallons per minute.
Based on the Uniform Fire Code (Table No. A-111-A-l) you would be allowed to build a structure not to
exceed 10,715 square feet.
We are in the process of revising the Aspen Glen Covenants, Conditions and Restrictions. We will be
changing the requirement for homes in excess of 4800 square feet requiring a fire sprinkling system
Instead, we will be following the Uniform Fire Code and the actual available fire flows of our central
water system
If you need any additional information, please let me know.
Sincerely,
ASPEN INFORMATION <;:ENTER: 555 EAST DURANT, SUITE 4A •ASPEN, COLORADO 81611 • 970-920-9400 • FAX 970-920-9494
ASPEN GLEN RECEPTLON CENTER: 9929 STATE HIGHWAY 82 • CARBONDALE, COLORADO 81623 • 970-963-4536 • 1.-800-277-4536
Aspen Glen Golf Company is an affiliate of Club Corporatio11 of America and The Melrose ComptJny.
ASPEN GLEN LOT D4D FEB. 1, 1996
SQ FT AREA CALCULATIONS
LOT 28342.00 D.30 8502.60 ALLOWED
WES.TUNIT EAST UNIT
AREA WIDE LONG SQFT AREA WIDE LONG SQ FT
15.50 15.50 240.25 1D 17.50 17.00 297.50
2 18.00 73.50 1323.00 11 17.50 4.50 78.75
3 18.50 52.00 962.00 12 17.50 64.50 1128.75
4 4.00 16.DD 64.0D 13 17.50 35.00 612.50
TOTAL LOWER LEVEL 2589.25 2117.5
5 36.50 38.00 1387.00 14 17.50 42.00 735.00
6 2.00 20.00 4D.OO 15 17.50 21.00 367.50
7 14.00 28.00 392.00 16 4.00 5.00 20.00
8 4.00 17.50 70.00
TOTAL UPPER LEVEL 1889.00 1122.50
TOTAL BOTH LEVELS 4478.25 3240.DD
SUMMARY
PERCENT
WEST UNIT 4478.25 58.021572
EAST UNIT 3240.00 41.978428
TOTAL 7718.25 100
E.B.
/
I I ,--~----1~ -------~--~----·---__ _J. _ --·-. -------~~ '."-~---------L 'i----Ir
_ . ---· i : . _ i I •
i '
oi 0 • ~ -r!-I -,
I
, :I
I
'<.r:~u...•===---o~ -i-Oj_
I
'91
-~ i _,
•
0. -·.
'k :o
' MASTER BEORM 0
EORM
' '--"--;;::;~-~--~---
I I
: I
i j
: i ! ] OPEN '!"O Sl:LOW
I:
I I I
I ·i ' . . '
1 i
11 .
===~-
' 1 i : I j,
I
1-: I' I'
-----1---- . ------------. --L ___ _J
" ' -.:. l
I
I o' -• r
IV I -1
I
j
.J
I
I
r
o!
-' I ~t
I
' i ;
--·-~·-·'·--
I ---_...___ _ _J~~
BACHRACH VIP LTD
PO BOX 1275
EDWARDS CO 81632
PHONE 970-926-1142
. UPPER LEVEL FLOORPLAN
1/16"•1'·0
DUPLEX R!:'.'.S!DE:NCE: FOR
DALE & DEVON McKAY@
ASPEN GLEN LOT D 40.
PREUMfNARY
'°' 3;
GOLF COURSE
1SECTION4 ¥C'!'10N 1 ::4JE~ON 2 jSECTlON 3
!,)PROP! R'TYLINE' -i -_-_· _i --t.;.l==.-,,-_ .. :.::.:::.::.:.:-_-.-_--;::~!:::-z:_=_ :;--t-r ---\ I r k~~ILOG ENVELOPE _]' ' /;/ ~ i· , ~/ ,// .. / HOT TUE V j r-_i1.~·~~·~~·~·----+'c:::'.:/::::l-i'.'/_,._-7"-/~··___ r_..__. ____ ..,_.~
__ .,__ ___ •• --,.<.),-~-_ti~ v/ ~/ / , --:: , ..:~-@ I
0 . .. ,.._ '
~-k-, .. -t;-r+I i~l~[bMm~""''~ I·~' •. ~~.13!-~~I-· 1 I I ' /1i ; -~~t---1-
f ~II! _ __._!----1if+' _ __._ 1
1
-..(il;.. _ _:""@_, '°~ ~ T: ---i---i j__j --!_ .
0
I
(\!
()\
i I l . 0 ·'C: ~ [· ~ 111 GARAGE :1 I ' \9 NI ;
/I'° l' . '~ ~t. T -ii o,-11:-1
' ! l I ~~ =~
"zo II '1 '1 I F, --,Q oo ' ,1, I ' ' 0, lr::t I v_ ~1,, . . ~ . - -lmL/MUO -' I '1, i/ I ;_· -· -I : o, i ~ ! ~ 'i -I ---1, 0 ~[=:=~G:~~:~ .~ ~0~6i-~1~-1~ ~~:: /;fl ~N~ .·.-~~~-t~~ ----i::
I ' I ~· 11 c I · t:: - , I
.. I ' ; i { ~ ' I I DINE H I·'" -0' . 'ij5"~· j·~"~'I~~~'; ··;,~,~~·~I [~-~-~--~. I ' ! ' ·f. ~' It; . . "·11 .. ! ~io 1~
":' I ~ I ' ; .· ' : "; 1-i i-I '" --+, '
-...,r; ' I ~J _loo:~ RI.II id1i 1.i' /' ''•
i -•;11~~ I Ii-ii 11;•1 ''I'/ '.;! 1'2~'Tlft : ,\ ' ' I. ~· ~ s:
' 1' ~ •1 ; ~~\/t~ y :\i , I i ! j 11 ! 111-1 ] • FAM I ',i ~ ~ . .
I -'1-&l ·-. \l ~f::==f.'=
I f <JJ I
I 01 11
' -•1 , ... -· -· '1~ ll:/. > . ,. ~ '2" '1 ' I . 9 i ___, I
I .. ! : I ~}i'T ii'l~..::Jl!I! L • ------l - -.l.~.._ -' ' : ;::: i -'--"\.11--rt --" -;;;/ "'
1
1 _,,_ i------·-·--.. E ·-·-· ·-d. d-·-· -I 1,' ii=~-l---=--------~;/_/-C--rl-1 !-~='---:
i
i -~·--T--r: ~ ~~· I I "'": I ~· ! ' ,_. I I
q) ! '[
1
1 ',j i J. ! i (Q:
J I'---L --+ ---J , , I .
I. I. I, J' . , : ~'---'--f----,--~-1-+_e;_'-_o_f-__ n~--____ -~+="" __ , __
I I I 11'-r.:p -~---~·-------+-----~-+·--------i,--..,..r~ I Pl.AN NORTH
1f BACHRACH VIP LTD
PO BOX. 1275
EDWARDS CO 81632
PHONE 970-926·1142
MAIN LEVEL FLOORPLAN
· DUPLEX RESIDENCE FOR
DALE & DEVON McKAY@
ASPEN GLEN LOT D 40.
:. PRELIMINARY
,_ .. -.
Hougland & Associates
5616 County Road 100
Carbondale, Colorado 81623
(970) 963-2312
Plan analysis based on
the 1994 Uniform Building Code
Project Number: Ga0194.96 Date: February 19, 1996
Project Name: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen Contractor: A & M Builders
Occupancy: R3,Ul Designer: Bachrach VIP LTD
Construction: V-N Engineer: J. C. Nicol #11499
Report By: Art Hougland
NOTE: The code items listed in this report are not intended to be a
complete listing of all possible code requirements in the 1994 UBC.
It is a guide to selected sections of the code.
Report created using Plan Analyst software by b w & a. (719) 599-5622
Portions of the material contained in this program are reproduced
from the Uniform Building Code ( 1991 edition) with permission of the
International Conference of Building Officials.
# SHEET IDENTIFICATION CORRECTION REQUIRED
====================================================================== 1 Sheet 3 Not indicated on plan: Provide an attic access (22X30
min) to each attic area.--Sec. 1505.1. No
access indicated for West dwelling unit.
2 Sheet 3 W. bed room #4 The door between a garage and the
dwelling is prohibited from opening into a
room used for sleeping purposes. Section
312 -REQUIREMENTS FOR GROUP U OCCUPANCIES,
Sub-section 312.4 -Special Hazards. /;f IJC. sec.3J:2.J
3 Sheet 3 W/11 STUDI0 11 : An "office", 11 study 11
, "media", 11 den",
11 studio", "family", "recreation", or room
with a similar designation, if configured
}\ as a bedroom as determined by the Garfield
5
3 J 0 • Count_y_ .. -:&tii_1_ding__QffJ:_cial shal 1 be provided S-<:.<: J:2oJ, 3 U f,)L CG-wi th(§_moke ~; a rescue_.OL~
, -----wliidowand natural light and (veltilationJas
required by this code. In addition the
room shall not have a door that opens
directly into the garage. ~ l{ {3 C., 5'= 312, f-.J
4 Sheet 3 E. bed room #6 All gas burning appliances are required
by the Uniform Mechanical Code to be
direct-vented appliances listed for use in
a sleeping room. Refer to the U.M.C. for
all requirements for appliances and
installation. Please provide verification
for review by the Building Official.
Page # 2
Required corrections for:
Project Id: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
# SHEET IDENTIFICATION CORRECTION REQUIRED
========================================================================
5 Spr.Pl? Building: Fire sprinkler systems are required for
Group R, Division 3 residential buildings
under certain conditions and in certain
areas of Garfield County. If required, a
plan is required to be submitted to the
Colorado Division of Fire Safety and the
fire district having jurisdiction
indicating compliance with N.F.P.A.
Standard No. 13-D. Please provide verif.
of compliance to the Building Official.
6 Sheet 3 Not indicated on plan: All penetrations of the membrane
on the garage side of the Occupancy
Separation wall between the dwelling and
the garage are required to comply with
Section 709.7 Membrane Penetrations.
7 Win.Sch. Adjacent to doors: Glazing in a hazardous location is
required to be glazed with safety material.
--Sec. 2406.3 & 2406.4. Window schedule
does not indicate compliance for areas
adjacent to doors.
8 Sheet 3 W/"STUDIO": This area requires glazed opening(s) having
an area equal to 1/10 or more of the floor
area. --Sec. 1203.2. This room is
configured as a habitable area and has no
openings for natural light. A redesign
will be required for this area prior to
issuance of a building permit.
9 Sheet 3 W/"STUDIO": This area requires operable exterior
opening(s) having an area equal to 1/20 or
more of the floor area. --Sec. 1203.3.
Please refer to previous comment.
10 Sheet 3 Not indicated on plan: A bathroom is required to have
an openable window or a mechanical
ventilation system. When there is a bathtub
or shower, such sustem shall be connected
directly to the outside. --Sec. 1203.3
11 Sheet 3 W/"STUDIO": This area requires an exterior opening for
emergency escape or rescue with clear
area/dimensions specified. --Sec. 310.4.
This room is configured to be reasonably
determined to be a habitable room and a
sleeping room. A redisign of this area is
required prior to the issuance of a buiding
permit.
12 Sheet 3 Not indicated on plan: A smoke detector is required in
the access area to all rooms used for
sleeping purposes. --Sec. 310.9.1.4
13 Sheet 3 Not indicated on plan: A smoke detector is required in
all rooms used for sleeping purposes. --
Sec. 310. 9 . 1. 4
Required corrections for:
Page # 3
Project Id: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
# SHEET IDENTIFICATION CORRECTION REQUIRED ======================================================================== 14 Sheet 3 Not indicated in plan: On an upper level where rooms
are used for sleeping purposes, a smoke
detector is required in the ceiling at the
stairs. --Sec. 310.9.1.4
15 Sheet 3 Not indicated in plan: A smoke detector is required on
all levels wired to an alarm in the bedroom
area(s). --Sec. 310.9.1.4
16 Sheet 3 E. Bed room #6 This factory-built fireplace must be an
approved unit. Include the manufacture's
name, model number, and approval
information. --Sec. 3102.5.1. The
appliance proposed for use in this room
must be a direct-vented appliance listed
for use in such an area.
17 Sheet 3 Not indicated on plan: The garage must be separated
from the dwelling by 1 hr. fire-resistive
construction on the garage side. --Table
3-B & 302.4 exc.#3
18 Section? No stair section: The minimum headroom vertically from
nosing line is 6 feet 8 inches. --Sec.
1006.15
19 Sheet #9 Not indicated on plan: A handrail is required along a
stairway. It is required to be 34 to 38
inches above the nosing of the steps and if
the side is open, the maximum size of an
opening in the railing at the stairway is 4
inches. --Sec. 1006.6 & 509.3
20 Sheet 9 Not indicated o~ plan: A 36 inch high guardrail with a
maximum opening of 4 inches is required
where step is greater than 30 inches to
floor or grade below. --Sec. 509.2 exc 1 &
509.3
21 Sheet 3 Not indicated on plan: The enclosed usable space under
the stairs is required to be protected by 1
hr. fire-resistive construction. --1006.12
Hougland & Associates
5616 County Road 100
Carbondale, Colorado 81623
(970) 963-2312
Plan analysis based on
the 1992 CABO One & Two Family Dwelling Code
Project Number: Ga0194.96 Date: February 19, 1996
Project Name: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
Occupancy: R3,Ul
Construction: V-N
Contractor: A & M Builders
Designer: Bachrach VIP LTD
Engineer: J. C. Nicol #11499
Report By: Art Hougland
NOTE: The code items listed in this report are not intended to be a
complete listing of all possible code requirements in the 1994 UBC.
It is a guide to selected sections of the code.
Report created using Plan Analyst software by b w & a. (719) 599-5622
=====================================================================
DIRECTION BOUNDARY
NORTH Property line
EAST Property line
SOUTH Property line
WEST Public way
SEPARATION
AREA INCREASE
26.0 Feet
48.0 Feet
26.0 Feet
77.0 Feet
FIRE PROTECTION
26.0 Feet
48.0 Feet
26.0 Feet
62.5 Feet
EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION
Section R-202
NORTH EAST SOUTH WEST BRG NON-BRG OPNG BRG NON-BRG OPNG BRG NON-BRG OPNG BRG NON-BRG OPNG WALL WALL PROT WALL WALL PROT WALL WALL PROT 0 hr 0 hr None 0 hr 0 hr None 0 hr 0 hr None
None --No fire protection requirements for openings.
NOP --Openings are not permitted in this wall.
WALL WALL PROT
0 hr 0 hr None
The fire-resistive rating is required for exposure from both sides.
If this is a townhouse, see section R-218.2
Page # 2
Code review for:
Project Id.: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot 040, Aspen Glen
FL NAME AREA MIN.LIGHT MIN.VENT NO.EXITS EGRESS ------------------------------------------------------------------------2 E. Bedroom #6
2 E. Bath room #6
2 E. Bedroom #5
2 E. Bath room #5
2 E.Stor. room (unfin)
2 W. Bedroom #1
2 W. Bath room #1
2 w. Bedroom #2
2 w. Bath room #2
2 W. Bedroom #3
2 W. Bath room #3
2 Halls, closets, etc.
TOTAL FOR FLOOR
1 East Garage
1 East Foyer
1 Dining/Family room
1 Kitchen
1 E. Util/Furnace room
1 E.Studio/Bedroom
1 E.Bedroom #7
1 E. Bath room
1 W. Garage
1 W. Foyer
1 Dining/Family room
1 W. Kitchen
1 W.Non-complying room
1 W. Util/Furnace room
1 W. Bedroom #4
1 W. Bath room #4
1 Halls, closets, etc.
TOTAL FOR FLOOR
BUILDING TOTAL
FOOTNOTES:
360
223
247
50
221
416
250
280
63
240
42
1065
3457
340
272
511
227
132
162
255
48
423
176
642
306
169
337
337
150
1162
5649
9106
28.8
17.84
19.76
4.0
• 0
33.28
20.0
22.4
5.04
19.2
3.36
.0
.0
.0
40.88
18.16
• 0
12.96
20.4
3.84
.0
.0
51.36
24.48
13.52
.0
26.96
12.0
.0
14.4
8.92
9.88
2.0
.0
16.64
10.0
11.2
2.52
9.6
1.68
• 0
• 0
.0
20.44
9.08 .o
6.48
10.2
1. 92
.0
• 0
25.68
12.24
6.76 .o
13.48
6.0 .o
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
Yes
Yes
No
No
No
No
No
Yes
No
Yes
No
No
1) EGRESS -An operable window or door that opens directly to the
exterior is required from this room. The minimum clear openable
area must meet the following. --Sec. R-210.2
1) The minimum clear height is 24 inches
2) The minimum clear width is 20 inches
3) The minimum clear area is 5.7 square feet
Exception: Grade floor window may be 5.0 square feet
4) The maximum sill height is 44 inches
2) The number of exits is based on R-210.1
3) Artificial light and a mechanical ventilation system may be
used in lieu of exterior openings for light and ventilation.
--Sec. R-203.l, exc.#2 & R-203.3, exc.
Page # 3
Code review for:
Project Id.: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
ROOM DIMENSIONS:
Habitable space shall have a ceiling height of not less than
7 feet 6 inches. Kitchens, halls, bathrooms and toilet compartments
may have a ceiling height of 7 feet measured to the lowest projection.
If the ceiling is sloping, then the minimum height is required in
only 1/2 of the area. --Sec. R-205
Every dwelling unit shall have at least one room which has not less
than 150 square feet of floor area. Other habitable rooms except
kitchens shall have an area of not less than 70 square feet. Kitchens
shall be at least 50 square feet. --Sec. R-204
Habitable rooms other than a kitchen shall not be less than 7 feet
in any dimension. --Sec. R-204
Shower compartments shall have at least 900 square inches of floor
area and be of sufficient size to inscribe a circle with a diameter
not less than 30 inches. Hinged shower doors shall open outward.
--Sec. P-2309.1
GLAZING REQUIREMENTS:
1) All glazing in hazardous locations is required to be of safety
glazing material. --Sec. R-208.3 & R-208.4
2) Note windows and doors in a tub or shower area are required
to be safety glazed when the bottom edge is less than 60 inches
above the drain inlet. --Sec. R-208.4 #5.
INSULATION NOTES:
1) Insulation that is exposed to rooms, attics, or crawl spaces, is
required to have a flame spread rating of 25 or less and a smoke
developed rating of 450 or less. --Sec. R-217.2 & R-217.3
2) Facings are not required to have a flame spread rating if it is
in a concealed space and the facing is in contact with a wall or
ceiling. --Sec. R-217.2, exception
3) Foam plastic insulations are required to be protected.
--Sec. R-216.2.3
SMOKE DETECTOR REQUIREMENTS:
A smoke detector is required outside of each separate sleeping area
in the immediate vicinity of the bedrooms. --Sec. R-215.1
A smoke detector is required on all stories. --Sec. R-215.1
Smoke detectors are required to be interconnected such that the
actuation of one alarm will actuate all the alarms.
The smoke detector is required to be wired to the building's power
source. When the primary powe.r is interrupted, it shall receive
power from a battery. --Sec. R-215.2
FIREPLACE REQUIREMENTS:
FACTORY BUILT FIREPLACE:
1) Unit must be an approved unit. --Sec. R-904.1
2) Clearances and hearth size must be per manufactures approval.
--Sec. R-904.1
3) Chimney height must be per manufacturer's approval.
Page # 4
Code review for:
Project Id.: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
SEPARATION OF AN ATTACHED GARAGE:
1) The garage shall be completely separated from the residence and
its attic area by 1/2-inch gypsum board or equivalent applied to
the garage side. --Sec. R-209.2
2) Doors between the garage and the residence are to be a 1 3/8 inch
solid core or 20-minute fire-rated. --Sec. R-209.1
NOTE: Openings from the garage to a room used for sleeping
purposes is not permitted.
3) Floor surfaces shall be of approved noncombustible material.
--Sec. R-209.3
STAIR REQUIREMENTS:
A stairway in a dwelling must be at least 36 inches wide.
--Sec. R-213.1 & Figure R-213.1
The maximum rise of a step is 8 1/4 inches and the minimum run is
9 inches. --Sec. R-213.l & --Figure R-213.1 Note: When risers are
closed, all treads may have a uniform projection not to exceed 1 1/2
inches. The maximum variation is in rise and run is 3/8 inch.
--Sec. R-213.1
Provide a handrail on one side a stairway if there is 3 or more
risers. The handrails is required to extend the full length of the
stairs. Ends shall be returned or terminate in newel post or safety
terminals. The maximum height of the handrail is 38 inches.
--Sec. R-214.1
The minimum height of the handrail is 30 inches if it not part of a
guardrail and 34 inches if it is part of a guardrail.
a guardrail is required where the drop off is greater than 30 inches.
Intermediate rails or ornamental closures which will not allow
passage of an object 6 inches or more in diameter are required.
Horizontal spacing between the vertical members shall be a maximum
of 4 inches at the nearest point between the members. --R-214.2
The minimum headroom is 6 ft.-8 inches. --Figure R-213.1
Enclosed accessible space under stairs shall have walls and soffits
protected on the enclosed side with 1/2 inch gypsum board.
--Sec. R-210.3
ATTIC REQUIREMENTS:
1) Provide an access to all attic areas with a clear height of 30
inches or more. The minimum size is 22 inches by 30 inches.
--Sec. R-708
2) Provide ventilation in all attic areas. The net free ventilating
area is to be not less than 1 square foot for each 150 square
feet of attic area. The vent area may be 1/300 if at least 50%
of the required ventilating area is provided by ventilators
located in the upper portion of the attic. The upper ventilators
must be at least 3 feet above the eve or cornice vents. The net
free cross-ventilation area may be not less than 1 to 300 of the
attic when a vapor barrier having a transmission rate not exceeding
1 perm is installed on the warm side of the ceiling. --Sec. R-707
For a 900.0 sq.ft. attic area:
Ratio Minimum sq.ft. of vent
1/150 6.0
1/300 3.0
Page # 5
Code review for:
Project Id.:. A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
HEATING REQUIREMENTS
1) Every dwelling unit shall be provided with heating facilities
capable of maintaining a room temperature of 68 degrees F
at a point 3 feet above the floor in all habitable rooms.
--Sec. 203.5
2) Heating and cooling appliances located in a garage shall be
protected from impact by automobiles. Appliances that generate
a glow, spark, or flame capable of igniting flammable vapors
shall be install with the burners, ignition devices, switches,
etc. at least 18 inches above the floor level. --Sec. M-1006.3
3) Fuel burning warm-air furnaces shall not be installed in a storage
closet or under a stairway. Except for direct vent furnaces, when
located in a bedroom or bathroom, it shall be installed in a sealed
enclosure and combustion air shall not be taken from the living
space. --Sec. M-1101.2.l
4) Every dwelling shall have an approved automatic water heater
or other type domestic water-heating system sufficient to supply
hot water to plumbing fixtures for bathing, washing, or culinary
purposes. --Sec. P-2411.1
5) Water heaters, which depend on the combustion of fuel, shall not
be installed in sleeping rooms, bathrooms, clothes closets, or
in closets or confined spaces opening int bathrooms or bedrooms.
--Sec. P2411.3 Exception: Direct vent-type water heaters.
1) Provide a window or door to the exterior from every room used for
sleeping and basements. --Sec. 310.4 A window must provide a clear
open area of 5.7 sq.ft., a clear height of 24 inches(minimum), and a
clear width of 20 inches(minimum). --Sec. 310.4
4) The minimum ceiling in a habitable space is 7 feet 6 inches except
kitchens, halls, and baths may have a ceiling height of 7 feet.
--Sec. 310.6.1
5) Provide a smoke detector in all sleeping rooms and areas having
access to sleeping rooms. --Sec. 310.9.1.4
6) If there is a basement, provide a smoke detector that is connected
to an alarm audible in all sleeping areas. --Sec. 310.9.1.4
7) Provide a smoke detector on all floors that is connected to an
alarm audible in all sleeping areas. --Sec. 310.9.1.4
Hougland & Associates
5616 County Road 100
Carbondale, Colorado 81623
(970) 963-2312
Plan analysis based on
the 1994 Uniform Building Code
Project Number: Ga0194.96 Date: February 19, 1996
Project Name: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
Contractor: A & M Builders
Occupancy: Designer: Bachrach VIP LTD
Construction: V-N Engineer: J. C. Nicol #11499
Report By: Art Hougland
NOTE: The code items listed in this report are not intended to be a
complete listing of all possible code requirements in the 1994 UBC.
It is a guide to selected sections of the code.
Report created using Plan Analyst software by b w & a. (719) 599-5622
Portions of the material contained in this program are reproduced
from the Uniform Building Code ( 1991 edition) with permission of the
International Conference of Building Officials.
# SHEET IDENTIFICATION CORRECTION REQUIRED
======================================================================
1 Sheet 3
2 Sheet 3
3 Sheet 3
4 Sheet 3
Not ind. in West unit Provide an attic access {22X30
min) to each attic area.--Sec. R-108
W. bedroom
Identified
E. bedroom
#4 The door between a garage and the
dwelling is prohibited from opening into a
room used for sleeping purposes. U.B.C.
Section 312 -REQUIREMENTS FOR GROUP U
OCCUPANCIES, Sub-section 312.4 -Special
Hazards.
as "Studio" An "office", "study", '1 media",
"den", "studio",. 11 family 11
, "recreation", or
room with a similar designation, if
configured as a bedroom as determined by
the Garfield County Building Official shall
be provided with smoke detectors, a rescue
or escape window and natural light and
veltilation as required by this code. In
addition the room shall not have a door
that opens directly into the garage.
#6 All gas burning appliances are required
by the Uniform Mechanical Code to be
direct-vented appliances listed for use in
a sleeping room. Refer to the U.M.C. for
all requirements for appliances and
installation an provide verification for
review by the Building Official.
Page # 2
Required corrections for:
Project Id: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
# SHEET IDENTIFICATION CORRECTION REQUIRED
======================================================================== 5 No plan Not included in plan: Fire sprinkler systems are
required for Group R, Division 3
residential buildings under certain
conditions and in certain areas of Garfield
County. If required, a plan is required to
be submitted to the Colorado Division of
Fire Safety and the fire district having
jurisdiction indicating compliance with
N.F.P.A. Standard No. 13-D
6 Sheet 3 Verify penetrations: All penetrations of the membrane
on the garage side of the Occupancy
Separation wa11 between the dwelling and
the garage are required to comply with
U.B.C. Section 709.7 Membrane Penetrations.
7 Sheet 6 Section 13 Walls and floors separating dwellings in a
duplex dwelling are required to be of
one-hour fire-resistive construction.
Section 310.2.2 Special Provisions. Please
provide detail of party wall at roof lines
of different elevations to verify
continuity of separation.
8 plan/ele Win. sch. not complete: Glazing in a hazardous
location is required to be glazed with
safety material. --Sec. R-208.3 & R-208.4.
9 Sheet 3 "Studio"
Window Schedule does not indicate all
safety glazing required in this building.
Please provide complete information for
review by the Building Official.
This area requires glazed opening(s) having
an area equal to 8% or more of the floor
area. --Sec. R-203.1. The room designated
as "STUDIO" is a habitable robm and is also
configured to be reasonably determined to
be a sleeping room. This room has no
natural light or ventilation and no means
of rescue or egress directly to the
outside. Redesign of this area is required
prior to permit issuance.
10 Sheet 3 Not indicated on plan: A bathroom is required to have
an openable window or a mechanical
ventilation system. --Sec. R-203.3
11 Sheet 3 See "STUDIO" comnt: This area requires an exterior
opening for emergency escape or rescue with
clear area/dimensions specified. --Sec.
R-210.2
12 Sheet 3 No information provided: A smoke detector is required
in the access area to all rooms used for
sleeping purposes. --Sec. R-215.1
Required corrections for:
Page # 3
Project Id: A & M Builders, two family dwelling
Address: 0158 Coyote, Lot D40, Aspen Glen
# SHEET IDENTIFICATION CORRECTION REQUIRED
==========================================~============================= 13 Sheet 3 Not indicated on plan: A smoke detector is required on
all levels. Note: All alarms are to be
interconnected such that the actuation of
one alarm will actuate all alarms. --Sec.
R-215.l
14 Sheet 3 E. bed room #6 This factory-built fireplace must be an
approved unit. Include the manufacture's
name, model number, and approval
information. --Sec. R-904.1. The gas
fireplace in this room must be a
direct-vented appliance listed for use in
this area.
15 Sheet 3 Not indicated on plan: The garage must be separated
from the dwelling including attic with
1/2-inch gypsum board on the garage side.
--Sec. R-209.2
16 Section? No stair sect. provided: The minimum headroom
vertically from nosing line is 6 feet 8
inches. --Figure R-213.1. Unable to
verify without stair section.
17 Sheet 9 Not indicated on plan: A handrail is required along a
stairway. It is required to be 30 to 38
inches above the nosing of the steps. --
Sec. R-214.1
18 Sheet 9 Not indicated on plan: A height of the
handrail/guardrail along the open side of a
stairway is required to be 34 to 38 inches
above the nosing of the steps. --Sec.
R-214.2
19 Sheet 9 Not indicated on plan: The maximum size of openings in
the handrail/guardrail on the open side of
a stairway is 6 inches. The horizontal
spacing between vertical members shall be a
maximum of 4 inches. --Sec. R-214.2
20 Sheet 9 Not indicated on plan: A 36 inch high guardrail with a
maximum opening of 6 inches is required
where step is greater than 30 inches to
floor or grade below. The horizontal
spacing between vertical members shall be a
maximum of 4 inches. --Sec. R-214.2
••
GARFIELD COUNTY BUILDING AND PLANNING
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
MANUFACTURED HOMES
ADDITIONS
AL TERA TI 0 NS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit
application and expedite the issuance of a permit it is important that
complete information be provided. Adequate and complete information will
prevent delays in the plan review process. Reviewing a plan and the
discoyery that required information has not been provided by the applicant
may result in the delay of the permit issuance and in proceeding with
building construction. The owner or contractor may be reqc'ired to provide
this information before the plan review may proceed. This causes delays
because other plans that are in line for review may be given attention before
the new information may be reviewed after it has been provided to the
Iluilding Department.
Please review this document to determine if you have enough
information to design your project and provide adequate information to
facilitate a plan review. If you do not, it may be helpful to obtain a book
titled "Dwelling construction under the Uniform Building Code. This
book is available to you through this department at our cost. Also,
please consider using a design professional for assistance in your
design and a construction professional for construction of your project.
To provide for a more understandable plan in order to determine
compliance with the building, plumbing and mechanical codes, applicants
are requested to review the following check list prior to and during design.
Applicants are required to indicate appropriately and to submit
completed check list at time of application for a permit:
1
·-.
l. Is a site plan included that indicates the distance of the proposed
building or addition to property lines, other buildings, set back V
~ments and utility easements?
~----No _____ o) Not necessary for this project _____ (2)
2. Does the site plan include the location of the l.S.D.S. (Individual
Sewage Disposal System) and the distances to property lines, wells (on
subject property and adjacent.properties) , streams or wat~urses? cJ(lf_
Yes No _____ o) Not necessary for this project _____ m
3. Does the site plan indicate the location and direction of the County or
~ate road accessing the property? c_::;J-----No _____ (n Not necessary for this project _____ (2)
4. Do the plans include a foundation plan indicating the size, location
and spacing of all reinforcing steel in accordance with the uniform
~~ing code or per stamped engineered design?
••
~----No _____ (1) Not necessary for this project _____ m
5 . Do the plans indicate the location and size of ventilation openings for
under floor crawl spaces and the clearances required between wood
and earth?
Yes . No _____ (1) Not necessary for this project-~
6. Do the plans indicate the size an location of ventilation openings for
~attic, roof joist spaces and soffits?
~----No _____ o) Not necessary for this project _____ (2)
7. Do the plans include design loads as required under the Uniform
Building code for roof snow loads, ( a minimum of 40 pounds per
/v~:r•ye foot in Garfield County) floor loads and wind loads?
~~----No _____ (1) Not necessary for this project _____ (,,
8. Does the plan include a building section drawing indicating
(~~dation, wall, floor and roof construction?
~----No _____ (1) Not necessary for this project _____ (>)
9. oe the building section drawing include size and spacing of floor
//joists wall studs, ceiling joists, roof rafters or joists or trusses?
/ Yes_ ___ No _____ o) Not necessary for this project _____ (2)
\
2
0 ,,,.--
10.
11.
12.
13.
14.
'·
I 5.
16.
Does the building section drawing or other detail include the method
(~~~ositive connection of all columns and beams? \J----No _____ 1., Not necessary for this project _____ 12i
I
·Does the plan indicate the height of the building or proposed addition
from the highest point of the building or addition measured at mid £
1s)'.fi\I\ between the ridge and the eave down to existing grade contours?'
('Yes J____ No -----'" Not necessary for this project _____ c2i
I .
\ ..... _ ____..../
Does the plan include any stove or zero clearance fireplace planned<kli'.
for installation including make and model and Colorado Phase II ../ Aj /ff""
certifications or phase II EPA certification? . / f Jd7d f1Cll'
Yes _____ No _____ oi Not necessary for this project-~-"' (?If' · .
Does the plan include a masonry fireplace including a fireplace
section indicating design to comply with the Uniform Building Code
Chapter 37?
Yes No _____ c1i Not nec~ssary for this project-~
Does the plan include a window schedule or other verification that rtlZ 1'1{,f!. e~s/rescue windows from sleeping rooms and/or basements 5 41 r< /,com~ly with the reqmrements of the Uniform Btuldmg Code? P~(}flt) · (Ol---No _____ c1i Not necessary for this project _____ 12i I
Does the plan include a window schedule or other verification that )r'?(t et: wind~ws provide natural light and ventilation for all habitable roomsp f.1 il {l f
(Yes ;;-1----No _____ 11i Not necessary for this project _____ 12i "1JtJ1'"'
Do the plans indicate the location of glazing subject to human impact r.tC
such as glass doors, glazing immediately adjacent to such doors; 5 "(l..
glazing adjacent to any surface normally used as a walking surface; f · -ref s!i,~g glass doors; fixed glass panels; shower doors and tub t-'d
fv~~loyures and specify safety glazing for these areas?
\_'.'../----No _____ oi Not necessary for this project _____ c2i
17. Is the location of all natural and liquid petroleum gas furnaces, boilers ~,;rrrlf
~ater heaters 1nd1cated on the plan? . . cof1•( I\ i
18
( Ye~)____ No _____ c1i Not necessary for this pro.iect _____ 12i .fl 1 1
-~
Do you understand that if you belong to a homeowners association, it
is your responsibility to obtain written permission from that
association, if required by that association, prior to submitting an
~cation for a building permit?
~---No _____ en Not necessary for this project _____ c2i
/
3
tJ t"tC
0 !"'"" ~ ;rflt ~1rt.lfl. s1 s1t111(1"
19. Have two (2) complete sets of constructions drawings been submitted
_wit11'V1e application?
Yes _.:____ No _____ (I) I
'--
,. Not necessary for this project _____ (>)
20. -~e~h~~-~: app~7:_~or the placement of a manufactured home?
If yes, have y~~;_,~pecified the size of the unit (min. 20ft x 20ft); live
roof load (min.40#); wind design (min. wind speed of 80 mph & 15 lb.
wind load); foundation design; method of anchoring?
Yes _____ No _____ n) Not necessary for this project _____ (>)
2 l. Have you designed or had this plan designed while considering
/Dtlilding and other construction code requirements?
'·
22.
( Yes _,____ No _____ rn
"
Does the plan accurately indicate what you intend to construct and
wha\t will receive a final inspection by the Garfield Building
;f,ep?rtment?
1
Yes/-----No _____ (3)
23 ... §2D_ ou understand that approval for design and/or construction
/:kha ges are required prior to the application of these changes?
(_Yes _____ No _____ (])
24. · Do you understand that the Building Department will collect a "Plan
Review" fee from you at the time of application and that you will be
required to pay the "Permit Fee" as well as any "School impact" or
':S·~ptic system" fees required, at the time you pick up your building
I. I .-7 ,.permit. (Y_3fl/ -----No _____ (,,
2 5. Are you aware that you are required to call for all inspections required
under the Uniform Building Code including approval on a final
~ection_m:ior lo receiving a Certificate of Occupancy and
(~~~/pancy of the building?
'----~~~ _____ No _____ (3)
26. Are you aware that the person signing the Permit Application whether
th "Owner", "Agent of the Owner", "General Contractor", "Contractor"
r/nr o herwise, signing the application is the party responsible for the
p'roj ct complying with the Uniform Codes". ·
Yes ____ No _____ (>)
_ (CONTINUED ON NEXT PAGE)
4
v
I hereby acknowledge that I have read, understand and answered these
questions accurately to the best of my ability.
date
~ob: I
Project Name:
Project Address:
Notes:
'· (1) If you have answered ·No~ on any of these questions you may be requ!red to provide this information at
lhe request of tbe·Building Official prior to beginning the plan review process. Delays in issuing the
permit are to he exper.rerl. Work may not proceed without the issuance of the permit.
(2) ff you have answered ·Not necessary for this pro jeer on any of the questions and Jt Is determined by the
Building Official that the in forrnation is necessary to review the: application and plans to determine
minimum con1pliance with the adopted codes, please expect !he following:
A. The application may be placed behind more recent applications for building permits in the review
process "nd 11()1 review•~cl unlil required iHf()rrnalion hns been provided arHl the application
rotates <'I gain to first position for review.
B. Delay in Issuance of the permit.
C. Delay in proceeding with construction.
(3) If you answered "No" lo this question the circurnstances descriUed in the question could result in a -stop
Work Order· being issued or a "Certificate of Occupancy· not being issu_ed.
PerApp02.95 Effective August 15, 1995
5
~w~"~ ~v ~ ~-ii-1 aJ 11~~11.1. ~J~ ~ w.;i:.,;,; M1lii..:~li!.:1~ ~aili..lf:,_;~
THIS CARD IS POSTED ON ·ruE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
_ ~ARFIELD COUNTY, COLORADO
Date Issued~/p/tf,_zoned Area __________ ---------------__ Permit No, ____ ;1;7___?___7 _________ _
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of the
proposed structure for which this per_mit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction of the above described structure, the permit may then be revoked by notice
from <;_:i.iuJ\f}' BJ.I!_ '!di_~g Iqspei:t d IMM_F/{)y,\ TEral:CO_ME NULL AND VOID,
Use f.l"f"'4 lit . '1U a /.4-rtJ It' ,...,-,_ <.,, ---· - )
. () l g -" fJ -e --'dttl e lt)eF$1' ·
Owner · . .(¥,--_ -Contractor 0 U) •.. A.J '
Setbacks Front Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning
Gas Piping-7-n"-7,:,, 1~.,_,__~
Frame 17 -/lo -'7-t;.--¥~
Plumbing-Rough 7-1 l-7 l.P ~
Electric-Rough _
(by STATE inspector) 7, l ') ,t,f b ."Ole -
Roof Covering 1c -fl-;,"-"
Electric-Final (by STATE inspector)9-
Heating Ventilation / c--."JL -cl-
Insulation_ -!/!-7-L /, .,
Final I c -3-6 -c/ --;/ .-
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 l 0 9 8th Street, . County Courthouse, Glenwood Springs, Colo.
APPROVED DONOTD~TROYTHISCARD
D~te ~ /J..'1 ht, Rv m. e,(~ /SA
~""""~ c;,c./il • J'"'.'" ~•J~."' ,u~ ~ 11,.;..·," ~••if>hliiliioo w~~ii..""~~J
IHIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
n.,, 1,..,p!~=~~~ A~~~~~,.~~~~.~~D~Zf 7 ........ .
AGREEMENT
Owner Contractor
Setbacks Front Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning Roof Covering '1-! 7-"i L. 1';"-V'
Electric-Final (by ST ATE inspector)
Footing s-s .96 , N<E
Foundation 3-1;1_ • 'Ji,, j, •
Plumbing-Underground -.3.,-{(& ~
Frame 1:,, -11-ql I< ~f>.
Plumbing-Rough'~ ·11-LJ& ;,';;:c
Electric-Rough _ \ .~ ·, .
(by STATE inspector) c;--\, -0\ It !l, \--
Heating Ventilation !£:' 1-· A~'. c; _ / J -"/l
Insulation(_, -, ~ / ::::
Final 9-11-'7 (a
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 10 9 8th Street, County Courthouse, Glenwood Springs, Colo.
APPROVED DONOTD~TROYTHISCARD rJ•t~j/J6/96 Rv !)·'}_ ,{dJr1~/.,up..
"'
.. '~
.f\,
Certificate Of Occupancy
No. 2886
No change in the character of occupancy of a
building shall be made without a Certificate
of Occupancy -(UBC Sec. 502)
Building Department
Garfield County, Colorado
This certificate is issued pursuant to the requirements of Section 307 of the Unifonn Building Code certifying that at
the time of issuance, this structure was in compliance with the various codes adopted by the County regulating
building construction or use for the following:
Use Classification One Unit of a Duplex w/Double Garage Building Pennit No. __ s_7_9_7 ____ _
R-3, U-1 PUD Type of Construction ___ v-_r_i _____ _ Group Zone District -----
Owner of Building A & M Jluilders Address 2633 Kinnikinnick, Vail, co
Building Address 0158 Coyote, Carbondale, co Locality Aspen Glen, D-40
Owner Contractor _ _.:_::..::..:: _____________ _ Address same
By 9----19'>1 MvJL-Yt-4 Date September 18, 1996
Chief Building Official
Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other
ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of
other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)).
"
Certificate Of Occupancy
No. 2921
Building Department
Garfield County, Colorado
No change in the character of occupancy of a
building shall be made "'lthout a Certificate
of Occupancy -(UBC Sec. 502)
This certificate is issued pursuant to the requirements of Section 307 of the Unifonn Building Code ce1tifying that at
the time of issuance, this structure was in compliance with the various codes adopted by the County regulating
building construction or use for the following:
Use Classification One Unit of a Duplex w/Double Garage B .ldit p . N 5797 m ig enmt o. --------
Group R-3, u-1 Type of Constn1ction ____ v--'N'-------Zone District Plm -----
Ov1nerofBuilding __ A_&~Mo....=:.Bu~1=·1~d=e~rs"---------Address 2633 Kinnikinnick, Vail, co
Building Address 0158 Coyote, Carbondale, co Locality Aspen Glen, D-40
Contractor Owner ------------------Adch-ess __ sa_n...:1e~-------------
. ' ~...:,)
~ ' --( ,..,.. / _ ___.. -,• By · ! ~ _ _,., -.. .,_,,, ·" ~
chiefBUifding Official .
Date November 1, 1996
Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other
ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or or
other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)).
** Retype of this c.o. due to original had wroog address. Same c.o. # used just corrected building address. (3/15/2002)
Certificate of Occupancy
No. 2921
No change in the character of occupancy of a
building shaU be made without a Certificate
ofOccupancy-{UBC Sec. 109.1)
Building Department
Garfield County, Colorado
This certificate is issued pursuant to the requirements of Section 109.3 of the Uniform Building Code certifying that at the time of issuance, this
structure was in compliance with the various codes adopted by the Cowrty regulating building construction or use for the following:
Use Classification Qie Unit of Duplex w/Garage Building Permit No.--'5'-'-7.::...97'--------
Group R3, Ul Type of Construction VN Zone District'--P_UD _____ _
Owner of Building A & M Builders Address 2633 Kinnikinnick Vail, co
Building Address 0158A Seeburg Circle Grrbondale, Locality Aspen Glen, IDtD-40, Unit A Aspen Glen
Contractor CMner Address same as above ---------------By~y. ~
Chief Building Official
Date November L 1996
Issuance ofa Certificate of Occupancy shall not be construed as an approval of a violation of the provisions oftbis code or of other
resolutions of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions oftbis code or of other resolutions
of the jurisdiction shall not be valid. (UBC Sec.109.1).
...
~
•
No. 2921
_.
_I .~ ,
--_ _,,....
Certificate Of Occupancy
..
Buildiag Departmewt
Garfidd Couty, Colorado
1-i}t--~)--,
D-
j
l' (:
r: .,
i:
(
This oedim•w is issued pursuant to the requi.re.meafa oC Section. WI of the Uniform Building Code certifying that at I 1
the 1ime of i$suaw:e, this ldru&:tdre was iB compliauce wilh the wricus oodes adopted by the County regulating -
bWJcting conatructillll or 11te ix Ore fultowkis: I ~
Use CJassfficatinn One 'lhlit of a Daplax w/lloub1e Gange Bw1d8tgPennit No. __ s1_91 ___ _
Gmu.p a-3, U-1 1)pe ofCooslntcCiaa. __ ....;Y....::"'tl~---Zone Diskict PIJD ._..;;.;:"'---
0Wner oflJWdiug A & M Builden
D 15g;:f _x..._Gui) Orc.i~
Building Address e1ae eo1uce, ~xtilale, co
Colfractot __ O!rtler ____________ _
-• A>l
By ~;"4
Aikhss 2633 J:iDuilcSm»clt. Vail. CO
Locality Asp<;? 91en, D-40
.Addn:ss~-same~--~~---~-~---
Date ~ i, 1'196
&• e.taCtztflkateof<k~ Dlt lle.....,.ldld •a ~111.affb provilian oftld1 eoU orof etha'
onlnMm ol'tllei!d•:lidloa. m pra...._ lo lire~ C8 'riDlideorGllCll tlte pswTi°lllmll of dlfs code or of
otfwenlhmttaitflleJ111Widha .. AUt fleftlid. (UBC See. 57(j)t.
c
' c
---.
l
**'Ibis is a retype of C.O. due to an in=rect building site address. (3/15/2002) Same c.o. # used just conected bldg. address
~-
Certificate of Occupancy
No. 2886
Building Department
Garfield County, Colorado
No change in the character of occupancy of a
building shall be made without a Certificate
ofOccupancy-(UBC Sec.109.1)
This certificate is issued pursuant to the requirements of Section 109.3 of the Uniform Building Code certifying that at the time of issuance, this
structure was in compliance with the various codes adopted by the County regulating building construction or use for the following:
Use Classification Che Unit of Duplex w/Garage Building Permit No .. -"-57,__,9'"'"7 ______ _
GroupR3, Ul Type of Construction VN Zone District __ PUD _____ _
Owner of Building A & M Builders Address 2633 Kinnikinnick. Vail. co
Building Address 0158B Seeburg Circle Qirbcmlale, m,cality IDt D-40 Unit B, Aspen Glen
Contractor Owner --'-='"'""----------~ Address sarre as above
By~Af_ ~
" Chief Building Official
Date September 18, 1996
Issuance of a Certificate of Occupancy shall not be construed as an approval ofa violation of the provisions of this code or of other
resolutions of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or of other resolutions
of the juri<ldiction shall not be valid. (UBC Sec. 109.1).
..
. .
•
"
·'
, _,,,,_ L.:rr r> -'-i o
Certificate Of Occupancy
No. 2886 ·
No oh:oage la Ille daander or oc:captDq' of a
l>llilding shall he ..-k wlthold a CortllkMe
of Oecapam:y-(UBC Sec. 502)
Building Department
Garfield County, Colorado
This certificate is issued pursuant to the requirements of Section 307 of the Uniform Building Code certifying that at
the time of issuance, this structure was in compliance with the various codes adopted by the County regulating
building construction or use for the following:
Use Classification One Unit of a Duplex w/Double Garage Building Perm.it No. _...:s..;..79;..;7 ___ _
Group R-.3, u-1 Type of Construction v-N --------Zone District PUD ----
Owner of Building A & M Builders
0 IS8S 5':e.b•(f9 Ci I"(. i.e: Building Address 9L&e eu;ute, cs.rll'ondale, co
Contractor Owner ---::;~~~~~~~
~
Chief Building Official
Address 2633 Rinnikimrl.ck, Vail, co
Locality Aspen Glen, D-40
Address same
Date September 18, 1996
Issuance or a Certificate of Occupancy shall not be construed as Rn Rf?proval of the provision Of th.IS code or Of other
ordinances or the jurisdiction. Certif"icated presuming ~ authority to violate or cancel the provisions or this code or of
other ordinances orthejnrisdictlon shall not be valid. (UBC Sec. 307(a)}.
"'Ill