HomeMy WebLinkAboutApplication- PermitJob Address
No, 6314
GARITELD COUNTY
BUII_DING, SANITATION and PLANNING DEPARTMENT
109 8th Street Saito 303
Glenwood Springs, Colorado 81601
(303) 945-8212
2496 Highway 133, Carbondale
Nature of Work Building Permit
Use of Building Bedroom & Living Room Addition
Own=Jerry & Susie Cheney
Cort ractor
Dave Cardiff Construction, Inc.
Amount of Permit 5 740.44
Permit: 448.75
Plan : 291.69
Paid $740.44 5-15-97
Date
May 27, 1997
S. Archuleta
Cicrk
BUILDING PERMIT APPLICATION
GARFIELD COUNTY, COLORADO
Applicant to complete numbered spaces only. PERMIT NO. 63/7" PARCEIJSCHED NO.
Joe ADDRESS aJ19/® 1 3 '
1
LEGAL
DESCR.
LOT NO.
BLOC
SUBDIVISION
2
OWNER 7AZA�y fr GC,m"/�
�_ : „.
c✓+ ,1'Y /J 3
ADDRESS Ale-. 1V0 LE CQ
G.110(..
PH.F S'.F /Ya
.F/
WK. PH,
3
CONTRACTOR�AV `.A'C01f,F
�+�r T..- =•NC-
�Y1&-S�i //"--.,0_4:,a Ali
ADDRESS, Ca_
p
PH94P-1 /3
LICENSE NO.
4Lam}...A�iv
ARCHITECT OR DESIGNER"7�.0rn$.5
t?^�
.1//4 M/)7/�' 14j/d-
ADDRESSi��J54,V�i3 • no
PH. T ��/4/7
LICENSE NO.
5
ENGINEER
ADDRESS
PH.
LICENSE NO,
6
S.F OF BUILDING 27
S.F OF LOT
HEIGHT
NO. OF FLOORS
7
f/ y� !
I, USE OF BUILDING A•//W../GL/� e)/V ed .--/6/N67 /200 �,%)v/77 /1/
8
CLASS of WORK: ❑ NEW,DDITIONN In ALTERATION ❑ REPAIR o MOVE ❑ REMOVE
9
DESca12E WORK: ADP 5-171,0' �-'` Oi di'A% U' /4 0./ Jai
1 0
GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE
DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN
1 1
VALUATION OF WORK: S ADJUSTED VAL.S
PLAN CHECK FEE a 91, b
1
PERMIT FEE �/.V.8,
fij, 7 \—
/
SPECIAL CONDITIONS_ 51/0 A ')( b 4. • 0 Z ::_,:3.,s- . O
/
, a -a
SCHOOL IMPACT FEE
NO. OF BUILDINGS ON
PARCEL
USE OF BUILDINGS NOW ON
PARCEL
TOTAL FEE 7510 +Y ye
OCC. GR.
CONST. TYPE
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL PLUMBING,
VENTILATING OR AR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED
NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED
OR ABANDONED FOR A PERIOD OF 1B0 DAYS AT ANY TIME AFTER
COMMENCED.
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION ANC
THE SAME TO 8E TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNING THIS TYPE OF WORK W1LL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME
AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE
LOC . LAW R LATING CONST'UCTION OR THE PERFORMANCE
"RUCTION
C "RUCTION • / / 1
r .— 1 d !. _. � • }
WATER SUPPLY
DATE PERMIT ISSUED .-.7-? 7
HEATING,
SaEctaLAa.aavaLs
REQUIRED
RECEIVED
NorREquraED
IS
ZONING
WORK S
HEALTH DEPT.
KNOW
ARE DEPT.
TO GIVE
SOIL REPORT
OR
OF
SETBACKS
FLOOD HAZARD
Signature
ofOwner, Contract. ora onaed agent,�ng r .d a•-�. + nctc�
l ( 1 _. ��_/J/I ` f ���
abov:
.
MAN UF HOME
w ding Department Approval to /5 Planning Department ApprovrStl�•7
///
OTHER
AGREEMENT
PERMISSION 15 HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
1N CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30,28201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE JINITIAL/P r -
p( 751o. V el S- Js -97
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector.,
2. Permanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3 A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4. A complete bathroom, with wash bowl, tub or shower, toilet stool, hot and cold running
water, non-absorbent floors and walls finished and a privacy door;
5 'All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high. constructed to all 1994 UBC requirements;
6. Outside grading done to where water will detour away from the.building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all
the required items are cornpieted and a final inspection made.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE
ITEMS HAVE BEEN COMPLETED.
"*'`Cannot occupy or use dwelling until a Certificate of Occupancy (C O.) is issued.
Occupancy or use of dwelling without a C 0 will be considered an illegal occupancy and may be
grounds for vacating premises until above conditions are rnet.
I understand and agree to abide by the above conditions for occupancy, use and the issuance ofa
Certificate of Occupancy for the dwelling under building permit 4
Signature Date
7 -x 0 4(
AAA-
.4.or / 3 5
72,e- 75 13 5 IV - -e4.
-ew -ed ) a o 1-5f� p ?.-c / IQ
16'4'
4 nao'hi 7144-7- Iv 12) Beco /
A- C'o'r'a tpa * e? Reo. 71 g vPrpsgrow
Gy4't 6 20 C 6 roo/ P -- -- 9y /i: ss
5t/°'71 a�- = . ,31;43'0,80
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
MANUFACTURED HOMES
ADDITIONS
ALTERATIONS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite
the issuance of a permit it is important that complete information be provided. Adequate and
complete information will prevent delays in the plan review process. Reviewing a plan and the
discovery that required information has not been provided by the applicant may result in the
delay of the permit issuance and in proceeding with building construction. The owner or
contractor may be required to provide this information before the plan review may proceed. This
causes delays because other plans that are in line for review may be given attention before the
new information may be reviewed after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. If you do not, it may
be helpful to obtain a book titled "Dwelling Construction under the Uniform Building
Code". This book is available to you through this department at our cost. Also, please
consider using a design professional for assistance in your design and a construction
professional for construction of your project.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following check list prior
to and during design. Applicants are require to indicate appropriately and to submit the
completed check list at time of application for a permit.
For the placement of a manufactured home, questions numbers 1.-4 and 19-28 are the only
questions that need to be addressed:
1. Is a site plan included that indicates the distances of the proposed building or addition to property
lines, other uildings, set back easements and utility easements?
Yes
2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and
the distances to property lines, wells (on subject property and adjacent properties), streams or
water cour
Yes
3. Does the site plan indicate the location and direction of the County or private road accessing the
property
Yes
4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing
steel in ac�rdance with the uniform building code or per stamped engineered design?
Yes ✓
5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and
the clearance- s required between wood and earth?
Yes ✓
6. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces
and soffits?
Yes +�
7 Do the plans include design Loads as required under the Uniform Building Code for roof snow
loads, (a min num of 40 pounds per square foot in Garfield County), floor loads and wind loads?
Yes ✓
S. Does the plan include a building section drawing indicating foundation, wall, floor and roof
construction?
Yes +�
9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafters joists or trusses?
Yes
10. Does the building section drawing or other detail include the method of positive connection of all
columns and beams?
Yes \Z
Does the plan indicate the height of the building or proposed addition from the highest point of
the building or addition measured at mid span between the ridge and the eave down to existing
grade contours?
Yes
12. Does the plan include any stove or zero clearance fireplace planned for installation including make
and model and Colorado Phase II frertifications or phase I1 EPA certification?
Yes No ✓
13 Does the plan include a masonry fireplace including a fireplace section indicating design to comply
with the Uniform Building Code $hapter 37?
Yes No
14. Does the plan include a window schedule or other verification that egress/rescue windows from
sleeping ro s and/or basements comply with the requirements of the Uniform Building Code?
Yes No
15, Does the plan include a window schedule or other verification that windows provide natural light
and venula ion for all habitable rooms?
Yes ✓ No
16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing for these areas?
Yes ✓ No
17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated
on the plan?
Yes No ✓
18. Do you understand that if you belong to a homeowners association, it is your responsibility to
obtain written permission fro the association, if required by that association, prior to submitting
an application for a building permit?
Yes ti✓ No
19. Will this b the only residential structure on the parcel?
Yes ✓ No If no -Explain:
20. Have two 2) complete sets of construction drawings been submitted with the application?
Yes
3
21. Is this an application for the placement of a manufactured home?
Yes No 1/ -
If
If yes, have you specified the size of the unit (min. 20ft. x 20ft); live roof load (min. 404); wind
design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring?
Yes
22. Have you designed or had this plan designed while considering building and other construction
code requirements?
Yes No
23. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes I✓ No
24. Do you understand that approval for design andlor construction changes are required prior to the
application of these changes?
Yes V No
25. Do you understand that the Building Department will collect a "Plan Review" fee from you at the
time of application and that you will be required to pay the "Permit Fee" as well as any "School
Impact" or eptic System" fees required, at the time you pick up your building permit?
Yes No
26. Are you aware that twenty four (24) hour notice is required for ail inspections? Inspections
will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood
Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00
p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before.
Failure to give twenty four (24) hour notice for inspections will delay your inspection one
(1)day?7
Yes V No
27, Are you aware that you are required to call for all inspections required under the Uniform Building
Code including approval on a final inspection prior to receiving a Certificate of Occupancy and
occupancy of the building?
Yes ✓ No
28. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of
the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the
project complying with the Uniform Building Code?
Yes I✓ No
4
I hereby acknowledge that I have read, understand and answered these questions to the best of my
ability.
rl /�•i�i
aVtaV/ /J
signature date
Phone: - �5V
(days);
9,5-1/4-9/.._5 (evenings)
Project Name: d// /1//)/J/T7D/t/
Project Address: c"9tGy e //3/ d al(11�3 5 ?D eP/ a,g
Notes: ff
If you have answered "No" on any of the questions. you may be required to provide this information at the request of the Building
Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed
without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review
the application and plans to determine minimum compliance with the adopted codes: the application may be placed behind more
recent applications for building permits in the review process and not reviewed until required information has been provided and
the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction.
PerAppO2.95 Effective August 15, 1995
5
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
CA FIELD COUNTY, COLORADO
Date Issued alr.. . .Zoned Area Permit No 6,3 I V .
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Ins and IMMEDIATELY BECOME NU D VOID. t
Use �ed � r 4vr974
1 tf 1i f rte+ Odd it 1 0A..l
Address or Legal Deseripti � `: ! ¢ 1, /ie_
Owne F r l Contractor a_ ti-. ; 1
Setbacks Front Side Side Rear
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing ‘ ,_.1(-7 ,____:-
Foundation 0 K C
Underground Plumbing
Insulation 7 - / (, _ * 7
Rough Plumbing
Drywall ,7 _ ; I_ --y /, /
Chimney & Vent
Electric Final (by State Inspector ygh-7?
Gas Piping
Final (O _z «-) 0_,,<r 6 -
Electric Rough (By State Inspector) ?-74-1, a'
Septic Final
Framing '7
(To include Roof in place and Windows
and Doors installed).
Notes:
1
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado.
O V E ❑ DO NOT DESTROY THIS CARD
Date �'' y J
egami-4044-
TF PLACED OUTSIDE - CO ER WITII CLEAR PLASTIC
APP