HomeMy WebLinkAboutSubsurface Investigation and OWTS Design 04.10.2017ffihL
tlrffirl\r,*
33 Four Wheel Drive Rd
Corbondale, C0 8ló2t
970-309-5259
April 10,2017 Project No. C1281
Alleghany Meadows
alleohanvm(Oomai l.com
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
250 Willow Lane
Garfield County, Colorado
Alleghany,
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the subject residence. The property outside of Carbondale, in an
area where OWTSs and wells are necessary. Original design documents have some changes.
Documents dated March 30, 2A17 should be discarded and replaced with these dated April 10,2017 .
Legal Description: Sêction: 35 Township: 7 Range:88 TR in Lot 12
Parcel lD: 2393-354-00-025
srrE coNDrtoNS
The property is currently developed with a 3-bedroom, single-family residence and is served by an
existing OWTS. An addition to the residence is proposed, which will result in one additional bedroom. A
bathroom is also proposed in the existing garage. The garage space will include plumbing such as a
toilet and sink, but no living area. The plumbing in the garage will be an auxiliary use to the main house.
The existing OWTS will be abandoned and replaced with a new OWTS, outlined in this design.
The private well serving the subject residence is located just beyond the southern property boundary. An
additionalwell serving the adjoining property to the north is located inside the neighboring residence (286
Willow Lane). Both wells must be located a minimum of 50Jeet from the proposed septic tank and a
minimum of 1OOJeet from the proposed soil treatment area (STA)
The proposed STA is located in the northwest corner of the property. The proposed STA is relatively flat.
The Roaring Fork River is located to the north of the subject property, and due to a number of ditches in
the area and the elevation of the property relative to the Roaring Fork River, the area is subject to
seasonally high groundwater.
Looking west looking east
Page2
SUBSURFACE
The subsurface was investigated on March 29,2017 by digging two soil profile test pit excavations (Test
Pits). A mini-excavator was used to excavate the test pits. A visual and tactile soil analysis was completed
by Carla Ostberg at the time of excavation.l
The materials encountered in the Test Pit #1 consisted of medium brown, moist sandy loam topsoil to 2.5-
feet, underlain by light brown sandy gravel with greater than 50% rock content to a maximum depth
explored of 6.0{eet. No bedrock or groundwater was encountered; however, we are estimating high
seasonal groundwater in this area al2.SJeet below native grade.
The materials encountered in Test Pit#2 consisted of light brown, sandy gravel to 1.S{eet, underlain by
medium brown, moist sandy loam topsoil to 2.O-feet, underlain by light brown sandy gravel with greater
than 50% rock content to a maximum depth explored of 8.OJeet. Groundwater was encountered at 7-feet;
however, we are estimating high seasonal groundwater in this area at 2.OJeet below native grade. We
observed moüling at approximately 4Jeet below native grade.
A tactile analysis of the topsoil was taken from Test P¡t #1. The soil formed a ball and a ribbon less than
1-inch in length before breaking. Soil structure shape was granular, soil structure grade was moderate,
and consistence was friable. Soil consistence was more gritty than smooth. This soil is classified as
Sandy Loam (Soil Type 2). Soils underlying the topsoil horizon have greater than 50% rock content.
This soil is classified as Sandy Gravel (Soil Type 0).
An unlined sand filter with a minimum depth of 3-feet of sand filter material is proposed. A long term
acceptance rate (LTAR) of 1.0 gallons per square foot will be used to design the OWTS, in accordance
with Garfield County On-Site Wastewater Treatment System Regulations, adopted April 14,2014.
Test Pit #1
' Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 3
Test Pit #2
Groundwater at 7-feet
.. 1
,É
Evidence of mottling at 4-feet
DESIGN SPECIFICATIONS
The existing septic tank and STA will be abandoned in place. The septic tank must be collapsed and
remaining void filled with gravel, sand, or compacted soil.
Design Calculations:
Averáge Design Flow = 75 GPD x 2 people/bedroom x 3 bedrooms + (75 GPD 4th bedroom) = 525 GPD
LTAR = 1.0 GPD/SF
525 GPD / 1.0 GPD/SF = 525 SF
The new OWTS design is based on 4-bedrooms and plumbing fixtures in the garage will be auxiliary to
the main residence. An average daily wastewater flow of 525 GPD will be used. The system installation
will include a new 150O-gallon, two-compartment concrete septic tank with an Orenco@ Biotube Pump
Vault and an Orenco@ PF3005 pump in the second compartment of the septic tank. We recommend
anchoring the septic tank with Deadmen because of the high seasonal groundwater table. The floats should
be set to dose approximately 90 gallons each pump cycle. The control panel for the pump must be located
within line of sight of the septic tank. We recommend Valley Precast out of Buena Vista be contracted for
start-up of the pumping system.
Effluent will be pressure dosed through a 1.5-inch diameter pump line to a mounded, 10'x 52.5' unlined
sand filter. The excavation for the sand filter will begin 1.O-foot below native grade. A minimum of 3-feet of
sand filter material will be installed in the over-excavated footprint, resulting in 2-feet of sand filter material
extending above native grade. Sand filter material must be clean, coarse sand, all passing a screen having
four meshes to the inch. The sand must have an effective size between 0.25 and 0.60 mm. The uniformity
coefficient must be 4.0 or less. Material meeting ASTM 33, for concrete sand, with one percent or less fines
passing 200 mesh sieve may be used.
Page 4
Laterals used to disperse the effluent must be surrounded by washed coarse screened gravel or crushed
stone. All of the gravel or stone must pass a2lr-inch screen and must be retained on al¿-inch screen. The
manifold must be 1.b-inches in diameter. Laterals must be 1.5-inches in diameterwith 5/32-inch diameter
orifices facing down, spaced 3{eet on center. We recommend Orenco@ Orifice Shields be installed on the
laterals at eaófr orifice. Laterals will begin 3-feet from the edges of the filter, with 2-feet between each lateral.
Each 1.5-inch diameter lateral must eid in a sweeping ell facing up with a ball valve for flushing. A soil
separation fabric should be placed over the gravel layer followed by approximately 1-foot of topsoil or other
suitable soil able to support vegetative growth.
The mound must have a minimum 3:1 slope (horizontal:vertical); therefore, the basal area will extend
approximately 9-feet beyond the sand filter on all sides (with a mound height of 3-feet above native grade).
Säils ¡n the åloped perímeter areas of the mound must be well draining and able to support vegetative
growth. This soil must be approved by this office prior to installation. The mound must be crowned in
a manner to promote drainage off of the STA.
The component manufacturers are typical of applications used by contractors and e_ngineers in this area'
Alternatives may be considered oi recommended by contacting our office. Construction must be
according to Cãrt¡elO County On-Site Wastewater Treatment System Regulations, the OWTS Permit
provided by Garfield County Building Department, and this design.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the STA. Untii vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. ihe property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance'
Geo-fabrics or plastics should not be used over the absorption area. No heavy equipment, machinery, or
materials should be placed on backfilled STAs. Livestock should not graze on the STA. Plumbing fixtures
should be checked to ensure that no additional water is being discharged to OWTS. For example, a running
toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
Page 5
ADDIT¡ONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water cãnditions and shall be connected to a control breaker separate from the high water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in excavation ef the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch'
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
þurp", dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
describeã in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county régulations. The cıntractor should have documented and demonstrated knowledge of the
requiremeñts and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
Reviewed By
(i¿rr,[* Lt*hxnr¿$\Carla Ostberg, MPH, REHS
Richard H. Petz,
8860å
Pump Selection for a Non-Pressurized System - Single Family Residence Project
3925 CR 154 I Garlield County, Colorado
Paramete¡s
300
Disdìarge A$sembl y Size
Transport Length
Transport Pipe Class
Transport Line Size
Disribut¡ng Vahê Modd
Max Ele\Étion L¡ft
Design Flow Rate
Flow Meter
'Add{n'Fridion Losses
Calculations
1.25
140
40
2.00
None
1.5
10
None
0
i nches
feet
indles
feet
gpm
i ndles
feet
Transport Velocity
Frictional Head Losses
0.9 fps
250
200
150
100
50
PumoData
oo
Lo
d(ú
.E¿
.9
Eg
o
aú
P
Lossthrough Discharge
Loss i n Transport
Lossthrough Valve
Lossthrough Flowmeter
AddÐn'Fricl¡on Losses
Pioe Volumes
o.7
0.3
0.0
0.0
0.0
feet
feet
feet
feet
feet
Vol of Trânsport Line 24.4 gaìs
Minimum Pump uircments
Dedgn FIow Rate
Total Dynamic Head
Orcnco Syttom'
Incorporated
Chøging tln Ulút rhc
lUo'A Doâ Wtuaþþ
10.0
2.5
gpm
feet
0 0 5 r0 15 20 25
Net Discharye (Spm)
30 35 40
L
*d
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
f 5l2nV 1ø 6t1z,,20o,t 3ø60Hz,
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
23oV 1Ø 60Hz., 200/460V 3Ø 60Hz
PF3010 High Head Effluent PumP
30 GPM, 1HP
230V 1 Ø 60H2, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, I-1l2HP
230V 1Ø 60H2, 2o012301460V 3Ø 60Hz
\
\
;;
Sy$em Curve:-
Pump Cune:'
Pump Optimal Rangee
Operating PointQ
Design PointQ
33 Four Whæl Drive RædCarbondãle, CdoEdo 81 623Phons 970.309.5259€rla@allæwiæptic.æm[tt$tnilff^åT{#Meadows Residence520 W¡llil LaneGarield County, ColoradoPþjectNumber C1281=ÞÊÞ^"ìûs9E+=ãe8rgIg:dFUTUREoMtN. s0'APPROXIMATELOCATION OFNE¡GHBORINGWELLNTANKEXISTING STALOCATION- MM&æUNDSPÆCEL' RECÆæ7100'TO SIA-38:g8.52.¿-\\MSS&æUNOSPARG!REC ffi96870' t5' 30'S€le: 1'=30{"MflS&ÐUNDSPÆCE!REC &2410fJå-5tgdtyËtIIIIIrdr+'l0'LINE7.3-\.'JIr---f------J3-BEDROOMRESIDENCE + IFUTURE BEDROOMoctO-- @IDR€NlusEÍ PRoPERÏ2sI wuow w¡I g,573 se,E. *l108rcRsr{l's'=À.<sxeEtr6L7-MtN. 100'STAMtN.50'TANKoæ¡uGtMoMffi&æUNDSPÆCELR€C å70168oùMM & æUNDS PÆCEIREC €72æ2DRAWINGS MUSÏ BE USED INCONJUNCTION WITH DESIGNLETTER DATED O4IIO/17Date: O3/3O/17 IRevised: (}4/1U17 Ioesisneoey: cBol w1 .0Reviewed By: RHPIDrun Bv: ANG I Sheet I of 4
ML$lnïlffi3Í¡ Four Wheel Drive RædCarbondale, ColoEdo 8l 623Phon€ 970.309.5259ærla@allæryiceseptic.com#c*pTOP OF BANKìl2'x 52.5' UNLINED MOUNDEDSAND FILTER. MIN. 3'SANDFILTER MATERIALI,5" DIA SCH4O PVÇLEVEL MANIFOLD'f .5. DIA SCH-40 PVC PUMP LINELINE OF 3:l MOUND(MIN. I% DRAIN BACKTO TANK)MOUND WILL BE PLACEDOVER A PORTION OFNEW 1sOO-GALLON,TWO.COMPARTMENT, CONCRETESEPTIC TANK W/'ORENCO' PUMPSYSTEM. ANCHOR WITH DEADMEN----qltI...- Jl57.9'EXISTING STA1.s" DtA scH-40 PVc L¡tenets-IIwtTH 5/32" DtAOR|FTCËSFACING DOWN 3'O.C-L-III__JEXISTING CONCRETESEPTIC TANKTO BEABANDONEDEND LATERALS IN A90'ELBOW FACING UP W|THBALLVALVE IN AVALVEBOX ACCESSIBLE ATGRADE FOR FLUSHING/...-oıÒaINSPECTION PORTAT EACHCORNER OF STAôADD DOUBLE-SWEEPCLEANOUTS ATALL'Y"t6-/.4',o52.NEW 4" DIA SDR-35 SEWERLINEWITH DOUBLE€WEEPCLEANOUT (MIN.2% FALLTOTANK)7'N49.4'L}BEDROOMRESIDENCE + 1FUTURE BEDROOMov9?a,0' 15' 30'søle: 1' = 3{}10'cn"rir. PATIqOOWOODDECKMeadows Residence. 520 Wllorv L-ansGarfi eld County, ColoradoProjectNumbeÊ C1281Date: 03/30/17 IRevised: tl4l10/17 IoesisnedBy: ceol w2.0Reviewed B¡n RHPID€wn Bv: ANG I sheet I of4
iln[tffitIt33 Four Wheel Drivê RædCarbondale, CdoEdo 81623Phone 970.309.5259cârla@a¡lsru¡cespt¡c.m^&WTO TOE OF SLOPEFOR MIN 3:l SLOPEiI10' x 52.5' PRESSURE DOSEDSAND FILTER MOUND WITH 3I.5' DIA SCH-40 PVC LATERALSWITH 5/32" DIAORIFICESFACING DOWN AT 3'O.C.1.5'DIA SCH4O PUMP LINE(MIN 1 % DRAINBACK TO TANK)END EACH LATERAL IN A 90' LONGSWEEPING ELL FACING UP WTH ABALL VALVE IN A VALVE BOXACCESSIBLE AT GRADE1.5" DIA SCH4O LEVEL MANIFOLDL,lINSPECTION PORT AT EACHCORNER OF EACH MOUNDrISTA PLAN1.5' DIA SCH4O PVC LATERALSWITH 5i32" DIA ORIFICE HOLESFACING DOWN AT 3' O.C.INSPECTION PORÏ AT EACHCORNERTOPSOIL COVERLANDSGAPE FABRIC ON GRAVELGRAVEL FILTER MEDIAGROUNDWATERSAND FILTER MATERIÅI-SIEVE %PASSINGt ioo4 I5/r00I 80/100í6 45/8530 2516050 15r'60r00 ul200 0nMeadows Residence520 Willow LanèGarfi eld County, ColoEdoProj€ctNumber C12Elw3.0Date: 0330/17 IRevised: (M/10/í7 Ioæ¡sneo Blf cBolReviewed Ay: RHPIDEwn Bv: ANG ISheet 3 of 4
0tt$ililff33 Four Wheel Drive RoadCarùondalê, ColoEdo 81 623Phone 970.309.5259€rla@allsêru¡6eptic.æm&[ld l,þWDESIGN4-BEDROOT RESIDENCE75 GAUPERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOMS + 75 GPD (4THBEDROOM)WASTEWATER FLOW = 525 GALLONS.IO" DIA VALVE BOXWITH SECURED LIDSLIP-ON PVC1.25' PVC SLIP X MALEPIPE THREADADAPTORW/CAPDO NOT GLUETANK:4-BEDROOM RESIDENCE = MlN. 125oGALLON SEPTICTANKÙSE 1sOO-GALLON, TWO-COMPARTMENT TANKWITH PUMP IN SECONDCOMPARTMENTINSULATED1.25" DIA BALLVALVETRACERWIREFINISHED GRADESOIL TREATMENT AREA (STA):LONG TERM ACCEPTANCE RATE (LTAR) = Lq çAU 5a ttCALCULATED STA = A/LTAR = 525 / 1.0 = s25 SFPRESSURE DOSED UNLINED SAND FILTERIO'X 52.5' UNLINED SAND FILTER WITH MIN. 3'SAND FILTER MATERIAL4'DIA1.25' DIA SCH-4{) PVCLONG SWEEP 90'ELBOWSEWER LINECHAMBÊR END CAPTO TANKHOUSE1.25' DrA SCH-40 PVCSUSPENDED TATERAL/l FLUSHING DETAIL\y NorrcffSOIL PROFILE TEST PIT NO. 1SOIL PROFILE TEST PIT NO.20LIGHT BROWN SANDY GRAVEL WITHGREATER THAN 50% ROCK (SOIL TYPE O)MEDIUM BROWN SANDY LOAMTOPSOILMEDIUM BROWN SANDY LOAM TOPSOIL234567I9ESTIMATED HIGH SESASONALGROUNÞWATER2'HIGH SESASONALGROUNDWATER 2.5'SLIP-ON PVCSPRINKLERVALVÊBOX AT GRADEFUlULIl-"o-lllôLIGHT BROWN SANDY GRAVELWITH GREATER THAN 5O7OROCK (SOrL TYPE 0)LIGHT BROWN SANDY GRAVELWITH GREATERTHAN 50%ROCK (SOTLTYPE0)LEGENDFnsandy loamiopsoilsandy gravelDO NOT GLUEFINISHED GRADE4' DIA SDR-35INSPECTION PIPESTA FILMEDIA1/4" DIA HOLE DRILLEDINTO TWO SIDES OF PIPEFOR VENTILATION(BELOW SLIP ON CAP)NO GROUNDWATER OR BEDROCK ENCOUNTERED INTEST PIT #1 (GROUNDWATER ESTIMATED 2.5)GROUNDWATER ENCOUNTERED IN TEST PIT #2 AT 7'(GROUNDWATER ESTIMATËD 2.5)Meadows Residence520 Wllil LaneGarfi eld County, CdoEdoPrcject Numben C1281w4.0Dãtè: O3/3O/17 IRevised: M/10/17 Ioesisneo ela CeolReviewed By: RHPIDÉwn Bv: ANG IShêet 4 of4
Item #
{5OOT-zGP-HH
{5OO Gallon Top Seam
Two Gompartment
with High Head PumP
DESIGN NOTES¡ Design per performonce test per ASTlvl
c1227. Top Eurfoce oreo 62.53 ft2¡ f'c GD 28 do)æ; concrete : 6,000 PSI
Min.
Instollotion:¡ Tonk to be set on 5" min. sond bed or
peo grovelr Îonk-to be bockfilled unlformly on oll
sides in lifts less thon 24" ond
mechonicolly compocted¡ Excovoted moteriol moy be used for
bockfìll, provided lorge stones ore
removedr Excovotion should be dewotered ond
tonk fìlled with woter prlor to being put
in service for instcllotion with woter
toble less thon 2' below groder Meets C1644-06 for resilient connectors¡ lnlet ond Outlet identified obove pipe¡ Delivered complete with internol piping¡ PVC rlsers ovoiloble¡ Secondory sofety screen ovoiloble with
PVC riser
ALLOWABLE BURY
(Bosed on Woter Toble)
WATER TABLE ALLOWABLL
EARTH FILL
0'- 0"3'- 0'
1'- O"5'- 0'
2'-0"4'-O"
J'- 0"4'- 0'
DRY 4'-O"
:¡.!
il , Tll( ::ID:
tCþar
-J;L-
t;
f-,
Top
View
.'-i;-l
Rubber
24" Minimum
Wt€sb
Dbcomed
Vahre
Pump:¡ -l¡we¡sTSS
and lmprovæeflr¡ent
qualltybñeHo Easled F,¡mp q/stom b maffidn m
the mad<etr Gomplete lndallaüon (wldrq, panel,
mounüng and dart+P Pocedum)¡ Gomdetewamanty
Soelent
JU6l
Digging Specs lnvert Dlmensions
tlet Length , Wdth
Section
Min.
He,þt
View
'SowËe @ntncß atnilaþ îor malnþnanæ9
Net Copocity Net Weight
Outlet Tot9,!Líd ,,Tonk Totol
1507 9ol 1509 gol 3600 lbs 1 1180 lbs '14980 lbs
15'
56"73" : 132"
Inlet Sid.e
1002 gol
IYaüerü
Wasû¡nnúer
r $yetems
r Fmduds
ffrslseäs?o4 ffigrer
Fax Blg) 3Þ$7rr a'sEMslã' æ81211
Webslb: u,ww.tdlûyproffiLÐrl
Ersll : fionffi æk@vdlrypecastæm
VALLEY
PRTCASI¡Inc. 'servico
Item #
DT
Tank Deadman
(Anül Buoyancy)
-_24il
Top
View
t
L
I
24"
l
I
. #4 Rebar Lifting Eyeo 6000 psi concrete. 600 lbs. Cable is not provided
Section
View 1
I
I
?
I
ll
--231t- *
Suggested lnstallation :
Two %" Cables
(Not provided)
Tumbuckle on
one side to
tighten cable
before installation
(Supplied by Others)
Tank
lnstallation
NOTE:
Please refer to Buoyancy Engineering
for each tank for conpct number of
deadmen needed.
; à.a ,':..
-..?
â.
Á '<.
O¡üodm[don
¡''!
'âa
Wrlrr ü
Iffrsüewat¡r {rrs}ro5670{ ffiar
Fer fftg) 39ffi727 ess\nsa' co8l211
lTrbelb: wwwrnlle¡prcætæm
Elmlk fonüdosk@alleyprsæt com
VALLEY :Fffiffi
PRTCASI¡Inc. rservåcan
Biotube@ ProPak Pump PackagetM
OrenCO W'Ð&a$tteø
60-Hz Series Pump Packages
Control panel
General
Orenco's Biotube@ ProPaK" is a complete, integrated pump package for
filtering and pumping effluent from septic tanks, Attd its patented pump
vault technology eliminates the need for separate dosing tanks,
This document provides deiailed information on the ProPak pump vault
and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel,
For more information on other ProPak components, see the following
0renco technical documents:
o Float Switch Assemblies (NSU-MF-MF-l)
o Discharge Assemblies (NTD-HV-HV-1 )
. Splice Boxes (NTD-SB-SB-1)
. External Splice Box (NTD-SB-SB-1)
Applications
The Biotube ProPak is designed to filter and pump effluent to either
gravìty or pressurized discharge points lt is intended for use in a septic
tank (one- or two-compartment) and can also be used in a pump tank.
The Biotube ProPak is designed to allow the effluent filter to be removed
for cleaning without the need to remove the pump vault or pump, simpli-
fying servicing.
Complete packages are available for on-demand or timed dosing sys-
tems with flow rates of 20, 30, and 50-gpm (1 3, 1,9, and 3,2 L/sec),
as well as with 50 Hz and 60 Hz power supplies.
Standard Models
BPP2ODD, BPP2ODD_SX BPP3OTDA, BPP3OTDD-SX, BBPPSOTDA,
BPPSOTDD-SX
Product Code DiagramIt
External splice box
(0ptional; internal splice
box comes standard.)
Riser lid
(not included)
,i i
Riser (not
included)
Discharge
assembly
Pump
liquid end
Pump motor
Float
bracket
Support pipe
Pump vault
Float stem
Floats
Float collar
Vault inlet holes
4-in, (100-mm)
turblne effluent pump
Biotube@ filter
caftridge
BPP t t-
Standard optionsl
Blank = 571n. (1448-nrnl vault height, internal
spllce box, standard discharge assembly68 = 68-¡n, (1 727'mnr) vault height
SX = external spllce box
CW = coldweatherdischargeassembly
DB = drainback discharge ass€mblyQ = cam lock
l\4FV = non-mercuryfloat
Control panel appl¡cat¡on:
DD = demand-dosing
TDA = t¡med-dosing, anaìog timer
TDD = timed dosing, digllal timet elapsed time
meter & counters
BiotubP ProPakrM pump package components.Pump flow rate, nom¡nal:
20 = 20 spm (1.3 Usec)
30 = 30gpm(1.9Usec)
50 = 50 opm (3,2 Usec)
Biotube@ ProPak'. pump vault
orenco Systems@ lnc.,8f4 Airway Ave., Sutherl¡n,0R 97479 USA. 800-348-9U3.541-459-4449. lvww,orenco,com NTD-BPP-1
Rev.1.2, @ 08/14
Page 1 of 4
ProPaK" Pump Vault Biotube@ Filter Cartridge
Materials of Construction Materials of Construction
Vault body Filter tubes Polyethylene
Support pipes PVC Caftridge end plates Polyurethane
Dimensions, in. (mm)Handle assembly PVC
A - Overall vault height 57 (1448) or 68 (1727)Dimensions, in.
B - Vault diameter 17 3 (439)A - Cartridge height 18
C - lnlet hole height 19 (475)B - Cartridge width 12 (305)
D - lnlet hole diameter þight holes total)2 Performance
1:.
E - Vault top to support pipe bracket base 3 (76)Biotube@ mesh opening 0.125 in (3 mm).
F - Vault bottom to filter cartridge base 4 (102)Total filter flow area 4.4 ft2 (0.4 m'z)
Total filter surface area 14.5 ft'z (1 .35 m2)
Maximum flow rate 140 gpm (8.8 Usec)
-0.062'in. (1.6-nn) f¡lter nesh available
D
AC
T-
I
B F_B_N
ProPakrM pump vautt (shown with Biotube filter and effluent pump) Biotub9 f¡lter cartr¡dge (shown with float switch assembly)
E
î
A
E
NTD-BPP.1
Rev. 1.2, @ 08fi4
?dge2 ol 4
i:'
grenco Systemso lnc, ,814 A¡rway Ave., Sutherlin,0R 97479 USA . 800-348-9843 . 541-459-4449 . www.orenco.com
Orenco
4-in. (100-mm) Turbine Etfluent Pumps
0renco's 4-in (100 mm)Turbine Eff luent Pumps are constructed of
lightweight, corrosion-resistant stainless steel and engineered plastics;
all are field-serviceable and repairable with common tools. All 60-Hz
PF Series models are CSA certified to the U.S. and Canadian safety
standards for effluent pumps, and meet UL requirements'
Power cords for Orenco's 4-in, (100-mm) turbine effluent pumps are
Type S00W 600-V motor cable (suitable for Class 1, Division 1 and2
applicaiions).
Materials of Construction
Discharge Stainless steel or glassJilled polypropylene
Discharge lrearing: Engineered thermoplastic (PEE$
Diffusers:GlassJilled PPO
lmpellers:Acetal (20',30 gmp), Noryl
lntake screens:PolypropVlene
Suclion connection: Stainless steel
Drive shaft:300 serìes stainless steel
Coupling;Sintered 300 series stainless steel
Shell:300 series stainless steel
Lubricant:Deionized water and propylene glycol
Specifications
Pump Curves
Pump curves, such as those shown here, can help you determine
the best pump for your system. Pump curves show the relationship
between flow (gpm or L/sec) and pressure (IDH), providing a graphical
representation of a pump's performance range. Pumps perform best
aTThetr nominal flow rate, measured in gpm or L/sec,
i40
0)e 120
Ë'*
È(E
980
(¡
P60\È
G.Ë 40
0.63
Flow in liters per second (L/sec)
1.26 1.89 2.52 3.15 3.79 4.42
i
\
PF 30051r \
\
ì
N
PF 500511
I \
I
i\\
\
43
30
24
e0¡
a)
6
G
Q)
(¡
(E
È\
(E
-ê
20
Nom. flow'
gpm (Usec)
Length
in, (mm)
Weight
lb (ks)
Discharge lmpellers
in., nominal 1
i0 20 30 40 50 60 70
Flow in gallons per minute (gpn)
20 (1,3)22 5 (572\ 26 (1 1) 1 ,25 4
30 (1.9) 21.3 (54 1) 25 (1 1) 1 .25 3
50 (3.2) 20.3 (516)27 (12) 2,00 2
Performance
Nom. flow hp (kW)
gpm ("isec)
Design
flow amps
Rated
cycles/day
Min liquid
level, in. (mm) 2
20 (1.3) 0 5 (0 37) 12.3 300 1B (457)
30 (1,9)05(037) 11.8 300 20 (508)
50 (3.2) 0.5 (0.37) 12.1 3oo 24 (610)
I Discharge ¡s femate NPf threa(tetl, IJ,S. n1ninal size, t0 acconn\date )renc1@ d¡scharge
hose and valve assembl¡es. CInsult your )renc7 Distribut1r ab)ut fittíngs t0 c1nnect discharge
assembl¡es t0 netnc-sized p¡p¡ng.
'¿ Mininurù liqutd level is fIr s¡ngle pumps when installed ¡n an )renc1\¡1tubd: Pt1PaktM Punlp
Vaull.
orenco Systems@ lnc. , 814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-98¡13 . 541-459'4449 ' www.orenco.com NTD-BPP-1
Rev. 1.2, O 08/14
Page 3 of 4
Gontrol Panel (Demand Dose)Gontrol Panel (Timed Dose)
Orenco's ProPaK' demand dose control panels are specifically engineered
for the ProPak pump package and are ideal for applications such as
demand dosing from a septic tank into a conventional gravity drainfield.
Orenco's ProPak timed dose conirol panels are specifically engineered for
the ProPak pump package and are ideal for applications such as timed
dosing from a septic tank into a pressurized drainfield or mound. Analog or
digital timers are available.
Materials of ConstructionMaterials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X Enclosure UV-resistant f iberglass,UL Type 4X
Hinges Stainless steel Hinges Stainless steel
Dimensions, in. (mm)Dimensions. in. (mm)
A - Height 11,5 (290)A - Height 11.5 (2e0)
B - Widrh e.5 (240)B - Widrh e 5 (240)
C - Depth 5.4 (135)C - Depth 5.4 (135)
Specifications Specifications
Panel ratinos 120U,314 hp (0.56 krt\|,14 A, sinole phase, 60 Hz Panel ratings 120U,314 hp (0,56 k\iv), 1 4 A, single phase, 60 Hz
1. Motor-starïcontactor 16 FLA, t hp (0.75 kV14,60 Hz; 2.5 million cycles Dual-mode Programmable for timed- or demand-dosing
(digital timedjdosing paneis only)at FLA (10 million at 5070 of FLA)
2. Circuit 120 V 10 A, 0FF/ON switch, Single pole breakers 1 a, Analog timer I 20 V repeat cycle from 0.05 seconds to 30
(not shown) hours, Separate variable controls for OFF and
0N time periods
1b. Digital timer .120-V programmable logic unit with built-in LCD
(shown below) screen and programming keys. Provides control
functions and timinq for panel operation
2. Motor-startcontactor 16 FLA, l hp (075 kW),60 Hz; 2.5 million cycles
at FLA 0 0 million at 50% of FLA)
3. Circuit breakers 120 V 10 A, 0FF/0N switch. Single pole 1 20 V
4. Toggle Switch Single-pole, double{hrow HOA switch, 20 A
5. Audio alarm 95 dB at 24 in (600 mm), warble{one sound, UL
Type 4X
6. Visual alarm 718-in, Q2-nn) diameter red lens, "Push{o-silence",
1 20 V LED, UL Type 4X
Control panel, t¡med-dose (digital timer m1del shown)
3. Toqqle switch Single-pole, doublelhrow HOA switch, 20 A
4. Audio alarm 95 dB at 24 in. (600 mm), warble{one sound, UL
Type 4X
5. Audio alarm 120 V automatic reset, DIN rail mount silence
relay
6. Visual alarm 718-in, Q2-nn) diameter red lens, "Push{o-silence,"
1 20 V LED, UL Type 4X
Control panel, demand-dose
6
@
ffio
ø
ffio
NTD-BPP-I
Rev.1.2, O 08fi4
Page 4 of 4
grenco Systems@ lnc. , 814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541 -459-¡1449 . www.orenco.com
PF Series 4-inch (1 00-mm)
Submers¡ble Etfluent Pumps
Applications
Our 4-inch (100-mm) Submersible Effluent Pumps are designed to
transport screened effluent (with lowTSS counts) from septic tanks 0r
separate dosingtanks Allour pumps are constructed of lightweight'
corrosion-resistant stainless steel and engineered plastics; all are field-
serviceable and repairable with common tools; and all 60-Hz PF Series
models are CSA certified to the U,S. and Canadian safety standards for
effluent pumps, meeting UL requirements.
Orenco's Fffltnnt Pumps are used in a variety of applications, including
pressurized drainfields, packed bed filters, mounds, aerobic units, effluent
irrigation, effluent sewers, wetlands, lagoons, and more, These pumps
are designed to be used with a Biotube@ pump vault or after a secondary
treatment system.
-
Discharge Connection
-
Bypass Orifice
Franklin
Liquid End
-
Suction Connection
Franklin
Super Stainless
Molor
Featu res/Specif ications
To specify this pump for your installation, require the following:
. Minimum 24-hour run-dry capability with no deterioration in pump life
or performance"
o Patented lÆ-inch (3-mm) bypass orifice to ensure flow recirculation
for motor cooling and to prevent air bind
. Liquid end repair kits available for better long-term cost of ownership
. TRI-SEALTM floating impeller design on 10, 15, 20, and 30 gpm
(0,6, 1.0, 1.3, and 1 ,9 L/sec) models; floating stack design on 50 and
75 gpn (3.2 and 4,7 Usec) models
¡ Franklin Electric Super Stainless motor, rated for continuous use and
frequent cycling
. Type S00W 600-V motor cable
. Five-year warranty 0n pump or retrofit liquid end from date of manu-
facture against defects in materials or workmanship
- Not applicable f1r ,-hp (3.73 kW) m1dels
Standard Models
See specifications chart, pages 2-3 for a list of standard pumps, For
a complete list of available pumps, call Orenco.
Product Gode Diagram
PF
Cord length,
Blank = 1030 =30
ft 1m¡:+
(3)
(e)
20 = 20 (6)
50 - 50(15)
Voltage, nameplate:
1 = 115- 200 = 2002=230t 4 -460
60 Hz
60 Hz
5 = single-phase 50 Hz
Frequency:
1 = single phase
3 = three-phase
(0.37)
(0.75)
(1.50)
(3.73)
05 = Yzltp
10-1hp
20 = znp
50 = 5hp
Horsepower (kW):
03 = 1Áhp(0,25)
07 = 3l hp (0,56)
15 = 1-%hp(1,1
30 = 3hp(2,24)
15 = 15(1.0)
30 = 30(1.9)
75 - 75 (4.7)
1)
(L/sec):Nominal flow, gpm
10 = 10(0.6)
20 = 20 (1.3)
50 = 50 (3.2)
"@î,, @
LF809AO
LB2O53896
Powered by
Fr"anklin ElecËric Pump, PF Series
- 1á-hp {0,37kW) only
1220 volts for 50 Hz pumps
iNote: 20joot cords are available only for single-phase pumps through 1 -]á hp
orenco Systemso lnc, , 814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 r 541 -459-¡1449 . www.orenco.com NTD-PU-PF.1
Rev.2.2, @ 09Í4
Page I of 6
GItød)o
()
E
G
cÉ
6I
g
.9o
=
6)
o
E2ã-!¿ E
cv
=E
È
E
ÈE!
EJ
6t-
'äæ
sþËErÈo-ø=i5Ë
6b=6)
ÉL
È
at,a
.!x
G¡
=
=-9
6ø
åF
6'E)ı
o
sl
o
g
(ga -Eå
Æ EË
Specifications,60 Hz
o
=oe6¡ø
-e II
ÊLE
.sÞ ìߨ al,o\cr+
Model
PFl 0051 1 10 (0.6) 0 50 (o .37) 1 115 12.7 12.7 6 1 1/¿ in, GFP 23,0 16 (406) 26(12) 300
PF1 0051 2 10 (0.6) 0 50 (0.37)1 23Q 240 6 3 6.3 6 1 l/¿ in GFP 23.0 (660) 16 (406) 26 (12) 300
PF10053200 10 o 50 (0.34 3 200 208 3 B 3.8 6 1 lz¿ in, GFP 23,0 (660) 16 26(12) 300
PF1007124'5 10 0.75 (0.56)1 230 240 8,3 8.3 I 1 l/¿ in, GFP 25.9 (658) 17 (432)30 (14) 300
PF10073200 4,5 10 (0,6)0.75 (0.56)3 200 208 5,1 5.2 8 1 l/¿ in, GFP 25.4 (645) 17 (432) 31 (14) 300
PF101 01 2 5'6 1 0 (0 6) 1 .00 (0.75)1 230 240 9.6 9.6 9 1 1z¿ in, GFP 27,9 (/09) 1B (457) 33 (15) 100
PF1 01 03200 r ô 1 0 (0 6) 1 .00 (0.75)3 200 208 5.5 5.5 9 1 l/¿ in, GFP 27.3 (693) 18 37 (17) 300
pF1 0201 2 5' 6' 7,8 1 0 (0 6) 2.00 (1 .49)1 230 240 12J 12,1 1B 1 /q in. SS 39.5 (1003) 22 (559) 48 e2) 100
PFl02032 5,6'8 10 (0 6) 2,00 (1 .49)3 230 240 7.5 7.6 18 I /+ in. SS 37,9 (963) 20 (508) 44 Q0) 300
PF10203200 5,6,8 10 (0 6) 2,00 (1 49)3 200 208 8] 8] 18 1 /¿ in. SS 37.9 (963) 20 (508) 44 Q0) 300
PFl 5031 1 15 (1 0) 0,33 (0.25)1 115 120 8.7 88 3 17¿in,GFP 19'5(495) 15 23 (10) 300
PF1 5031 2 15 (1 0) 0.33 (0,25) 1 230 240 4.4 4.5 3 1 /+ in. GFP 1s,5 (¿95) 1 5 (380)23 (10) 300
PF20051 1 20 (1 3) 0.50 1 1 1 5 120 12.3 12 5 4 1 lq in. GFP 22'3 (566) 18 (4571 25 (11) 300
PF200512 20 (1 3) 0.50 (0 37)1 230 240 6.4 6 5 4 1 lqin. GFP 22'5 (572) 18 (457) 26 (12) 300
PF20053200 20 (1.3) 0.50 (0 3/)3 200 208 3] 3 I 4 1 lqin. GFP 22.3 (566) 18 (457) 26 (12) 300
PF201 012 4's 20 (1 ,3) 1 .00 (0,75)1 230 240 1 0.5 1 0 5 7 1 lq in. GFP 28/ (721) 20 33 (15) 100
PF201032004,5 20(1 3) 1,00(0.75)3 200 208 5.8 5 I 7 1 lq in. GFP 27 .B V06) 20 (508) 33 (1 5) 300
PF2015124'5 20 (1.3) 1.50 (1 11)1 230 240 12.4 126 9 1 /+ in. GFP 34,0 (864) 24 (610) 41 (19) 100
PF20153200 4,5 20 (1.3) 1.50 (1.1 1)3 200 208 7 .1 7 ,2 I 1 lq in. GFP 30.7 (780) 20 (508) 35 (1 6) 300
PF30051 1 30 (1.9) 0.50 (0 37)1 115 120 11.8 11 B 3 1 l/¿ in. GFP 21.3 (541) 20 28 (13) 300
PF30051 2 30 (1.e) 0.50 (0,37)1 230 240 6,2 6.2 3 1 lq in. GtP 21 '3 (541) 20 (508) 25 (11) 300
PF30053200 30 (1,9) 0.50 3 200 208 3 6 3.6 3 1 Yqin.GFP 21.3 (541) 20 (508) 25 (1 1) 300
PF30071 2 30 (1,9) 0.75 (0,56)1 230 240 8.5 8.5 5 1 7¿ in GFP 24.8 (630) 21 (533) 29 (13) 300
PF30073200 30 (1.9) 0,75 (0.56)3 200 208 4 I 4.9 5 I /+ in. GFP 24,6 (625) 21 30 (14) 300
PF301012 4 30 (1,9)1 .00 (0 75) 1 230 240 10.4 10,4 6 1 1z¿ in GFP 27 0 (686) 22 (559)32 (15) 100
PF301 03200 4 30 (1.9) 1.00 (0 75)3 200 208 5,8 5.8 6 1 l/+ in GFP 26,4 (671) 22 (559) 33 (15) 300
PF301 51 2 4'5 30 (1 .9) 1 ,50 (1 1 1) 1 230 240 12,6 12.6 I 1 7¿ in GFP 32 8 (833) 24 (61 0) 40 (1 B) 1 00
PF301 53200 4'5 30 (1.9) 1.50 (1.1 1)3 200 208 61 6 I I 1 l/¿ in GFP 29,8 (757) 22 34 (15) 300
PF30153445 30(1.9) 1,50(1 11)3 460 480 2,8 2 B I 1 l/¿ in GFP 29 5 (685) 22 (555) 34 (1 5) 300
Pt3020125'6'7 30 (1.9) 2,00 (1 49)1 230 240 110 11,0 10 1%in.SS 355(902) 26(660) 44(20) 100
PF30203200 16 30 (1,9) 2.00 (1 ,49) 3 200 208 9.3 9.3 10 1 % in. SS 34 0 24 (610) 41 09) 300
pF303012 5 6,7'8 30 (1 9) 3.00 (2,23)1 230 240 168 16.8 14 1%in.SS 445(1130) 33 54 Q4) 100
PF303032 5,6'8 30 (1.9) 3.00 (2 23)3 230 240 10.0 1 0,1 14 1 /q in. SS 44,3 (1125) 27 (686) 52 Q4) 300
PF3050'12 5' 6,7,8 30 (1 ,9) 5.00 (3,73)1 230 240 25.6 25.8 23 1 % in. SS 66 5 (1689) 53 (1 346) 82 ß7) 1 00
PF305032 5'6,8 30 (1 9) 5,00 (3 73)3 230 240 16.6 16 6 23 1 % in, SS 60.8 (1544) 48 (1219) 66 (30) 300
pF30503200 5'6'8 30 (1,9) 5.00 (3.73)3 200 208 18,7 18,7 23 1 % in. SS 60.8 (1544) 48 (1 219) 66 (30) 300
PF50051 1 50 (3 2) o.5o (0 37)1 1 1 5 120 12j 12j 2 2 in, SS 20.3 (516) 24 (61 0) 27 (12) 300
PF500512 50 (3 2) 0 50 1 230 240 62 6,2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500532 50 (3 2) 0 50 (0.37)3 230 240 3.0 3 0 2 2 in, SS 20.3 (516) 24 0) 28 (13) 300
PF50053200 50 (3 2) 0 50 (0.37) 3 200 208 3,7 .3.7 2 2 in, SS 20.3 (516) 24 (610)28 (13) 300
PF500534 50 (3 2) 0 50 (0.34 3 460 480 1.5 1 5 2 2 in SS 20.3 (516) 24 (610) 28 (13) 300
PF50071 2 50 (3 2) 0.75 (0 .56) 1 230 240 8.5 15 3 2 in, SS 23.7 25 (635) 31 (14) 300
Pt500732 50 (3.2) 0.75 (0.s6) 3 230 240 3.9 3I 3 2 in. SS 23.7 (602) 25 (635)32 (15) 300
PF5oo732oo 50 (3.2) 0,75 (0.56)3 200 208 4.9 4,9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300
NTD-PU-PF-1
Rev.2.2, O 09/14
Page 2 of 6
grenco Systems@ |nc.,814 Airway Ave,, Sutherlin,0R 97479 USA o 800-348-9843 .541-459-M49. www.orenco.com
Specifications, 60 Hz (continued)€EIø6'oð
EoE
6¡
o
!tãâ.!¿ E.E
=.E
È
È
5Ð
oJ
ór-.äe
sþËF
øt=i5ts
Ø
-Þ6'
CL
Ë
øct
(ExagE
=ê
et u,
6=TF
Ðs
5!
ED
6¡
=
a6
.gt ıØ al,å¿
Ë
Ëå
o
=êoû¡6
-9 II
t¡,Et
Eo
(g
Èo
oø
G,
À
Model
PF500734 50 (0.56) 3 460 480 o.o .8 3 2 in. SS 34.8 tq 4) 300
26 (660) 35 (16) 1ooPF501 01 2 50 (3.2) 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686)
PF501 03200 50 (3.2) 1.00 (0.75)3 200 208 5] 5] 4 2 in. SS 26,4 (671) 26 (660) 39 (18) 300
PF501 034 50 (3.2) 1.00 (0.75)3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF5015124 50 (3.2) 1.50 (1,11)1 230 240 12.5 12.6 5 2 in. SS 32.5 (826)30(/62\ 41 (19) 100
PF501532004 50 (3.2) 1.50 (1 11) 3 200 208 7,0 7.0 5 2 in. SS 2s3 (t44)26 (660) 35 (16) 300
PF503012 4,5,7'B 50 (3 2) 3.00 (2 23)1 230 240 17 .7 17 .7 I 2 in. SS 43 0 (1092) 37 (940) 55 (25) 1 00
PF50303200 4'r8 50 (3.2) 3.00 (2 23) 3 200 208 13.1 13.1 8 2 in. SS 43,4 (1102) 30 (762) 55 (25) 300
pF503034 4,5'B 50 (3,2) 3 00 (2,23) 3 460 4q0 5.3 5.3 I 2 in. SS 40.0 (101 6) 31 55 (25) 300
PF505012 5,6,7,8 50 5 o0 (3.73) 1 230 240 26,2 26.4 13 2 in. SS 65.4 (1661) 55
240 16,5 16.5 1 3 2 in. SS 59.3 (1506)
64 300
pF505032 5'6'7'8 50 (3 2) 5,00 (3 73) 3 230 (1245) 64 (29) 3oo
PF751012 75 (4.7) 1 00 1 230 240 9.9 10.0 3 2 in, SS 27.0 (686) 27 (680) 34 (15) 100
PF751512 75 (4.7) 1,50 (1 11)1 230 240 12j 12.3 4 2 in. SS 33.4 (B4B)30 (t62\ 44 Q0) 100
Specifications, S0 Hz
Model
PF1 00552 0 0.50 (0,37) 1 220 230 3.9 6 1 /q in. GFP 23.0 (584)17 (432)
PF1 00752 4,5 1 0 (0.6) 0.75 (0.56)1 220 230 6.2 6,2 9 1 % in. GFP 26.8 (658) 17 (432) 30 (14) 300
PFl 01 552 5' 6 1 0 (0,6) 1 .50 (1 .1 1)1 220 230 10.5 11,4 18 1 /¿ in. SS 39.5 (1003) 22 (5591 46 Q1l 300
PF300552 30 (1.e) 0.50 1 220 230 4.1 4.1 4 1 1/q in. GFP 22.5 (572) 19 (483) 26 (12) 300
PF300752 30 (1.9) 0.75 (0.56)1 220 230 6.1 6 l 5 1 l/¿ in. GFP 24.8 (630)19 (483) 29 (13) 300
PF301 052 30 (1,e) 1.00 (0.75)1 220 230 7 ,4 7 .4 7 1 lq in. GFP 28.4 (721) 20 (508) 32 (15) 100
PF3o1 552 4' 5 30 (1 .9) 1 ,50 (1 .1 1)1 220 230 9.3 9.3 8 1 % in. GFP 35.4 (899) 24 (610) 40 (18) 100
PF500552 50 (3.2) 0.50 1 220 230 4,0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300
PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6,3 6.4 3 2 in. SS 23.7 (602)25 (635) 31 (14) 300
PF501 052 50 (3.2) 1j00 (0.75) 1 220 230 7.3 7.4 4 2 in. SS 27'0 (686) 26 (660)35 (16) 100
PF501 552 50 (3.2) 1 .50 (l .1 1)1 220 230 9,1 I 1 5 2 in. SS 32.5 (826) 30 (62) 42 (1s) 100
PF751052 75 (3.2) 1.00
Distribuf1r about fittings to clnnect h1se and valve assemblies t0 netr¡c-sized p¡ping.
1renco for nore infornatíon.
3 We¡ght includes cart1n and 10 ft (3'n) cord.
4 H¡gh-pressure d¡scharge assenbly requ¡red.
5 D0 n1t use cam-l)ck opt¡on Q) 0n discharge assembly.
6 Cust1m discharge assenbly requ¡red f1r these punps. Contact qrenc1.
7 Capac¡tlr pack (s\ld separately 0r installed ¡n a cust1m control panel) required Íor th¡s punp, C1ntact qrenco.
8 Torque l}cks are availatJte for atl punps, and are supplied with 3-hp and ,-hp punps
NTD.PU-PF-1
Rev. 2.2, @ 09/.l4
Page 3 of 6
1 220 230 7.3 7.3 4 2 in. SS 30.0 27 (686) 34 (15) 100
grenco Systemso lnc. ,814 Airway Ave,, Sutherl¡n,0R 97479 USA r 800-3¿18-9843 . 541-459-4449. www.orenco.com
Materials of Construction
Discharge GlassJilled or stainless steel
Dischargebearing Engineeredthermoplastic (PEEK)
Diffusers Glass-filled PPO (Noryl GFN3)
lmpellers Celcon@ acetal copolymer on 1 0-,20, and 30-qpm models; 50-gpm impellers are Noryl GFN3
lntake screen Polypropylene
Suctionconnection Stainlesssteel
Drive shaft 7/16 inch hexagonal stainless steel, 300 series
Coupling Sintered stainless steel, 300 series
Shell Stainless steel, 300 ser¡es
Motor Franklin motor exterior constructed of stainless steel, M0t0rfilled with deionized water and propylene glycol for constant lubrication. Hermetically
sealed motor houslng ensures moisture{ree windirrys, All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Single-
phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase mptors through 1,5 hp
(1.11kW have built-in thermal overload protection, which trips aI 203'221' F (95-1 05" C).
Using a Pump Gurve
A pump curre helps you delermìne the best pump for your system, Pump curves show the relationship between flow (gpm or L/sec) and pressure
(total dynamic head or TDH), providing a graphical representation of a pump's optimal performance range. Pumps perform best at their nominal
flow rate - the value, measured in gpm, expressed by the first two numerals in an Orenco pump nornenclature, The graphs in this section show
optimal pump operation ranges wìth a solid line, Flow flow rates outsjde 0f these ranges are shown with a dashed line. For the most accurate
pump specification, use Orenco's PumpSelect'" software,
Pump Curves, 60 Hz Models
160
PFl5 Series,60 H2,0,3 hp
36912151821
Flow in gallons per ninute (gpm)
140
(¡)
qr
s 120
f roo
È
EBo€
CI
E60\
:40(È
.a
20
800
700
(¡¡
qr
s 600
S soo
!I ¿oos
a
Fro\I zoo
tE
Ê
100
002468101214
Flow in gallons per ninute (gpm)
1ô 0 24
PF10 Series,60 Hz,0.5 - 2.0 hp
PF1020
\
PFî0f0
"'..i\
lPFl007
':i:::!!!!l
lprroos ......".::\
PFl005-FC
w/7q"flow
controller
NTD.PU-PF.I
Rev.2.2, @ 09/14
Page 4 of 6
orenco Systems@ lnc, , 814 A¡rway Ave,, Sutherlin, 0B 97479 USA . 800-348-9843 . 541 -459-¡1449 . www.orenco.com
PF20 Series,60 Hz,0.5 - 1.5 hp
tf f¿utJ
tFF2ol
lFF2oor +
60 Hz Models (continued)
5101520253035
FIow in gallons per minute (gpm)
10 20 30 40 50 60 70 80 90
Flow in gallons per minute (gpm)
10 15 20 25 30 35 40
Flow in gallons per minute (gpm)
00
900
800
a{ zoo
F ooo\¡¡
I soo
(¡¡Êo 400
F ¡oo>È
.s 200
Ê
90
(¡).s 80
=70ı\. 60È(È
e50()'È 40
Eà30
F20È
10
(¡¡* sso
È gooa
È 250G(¡)€.a 200
E 1bo\È
E 100
.e
50
400
350
a
c¡
s 300
f zso
È
E zoos
C¡
$ rso
\!' roo(È
.È
50
0
455400
100450
'10 20 30 40 50 60 70 80 90 100
FIow in gallons per minute (gpn)
00
00
PF30 Series,60 H2,0.5 - 5.0 hp
PF3ft30
....:,. .,-ì--\\
lPF30r U -=N
PF50 Series,60 Hz,0.5 - 5.0 hp
I
PF75 Series,60 Hz, 1.0 - 1.5 hp
-\\
orenco Systemsô lnc. ,814 Airway Ave., Sutherlin,0R 97479 USA. 800-3¿18-9M3 o il1-459-4449. uvt¡vw.orenco.com 1'ITD-PU-PF-1
Rev.2.2, @ 09Í4
Page 5 of 6
PFl0 Ser¡es, 50 H2,0.37 - 1.11 kW
ta
rrtiii:;
;j....,..,-. .
PFl005-FC
w/6mmflow
conlroller
Pump Gurves, 50 Hz Models
Flow in gallons per ninute (gpn),
1.6 3.2 4.8 6.3 7.9 9.5
Flow in gallons per minute6.3 13 19
nominal11 13
(gpn), noninal?5 32
180 120
1
eq¡1
(¡¡
et.1
ì!(Èq¡
()
G:È
(s
Ê
60
40
2ß
00
80
60
40
IU
328.8
oÈ
262 Ê
=o
r97 b.È.G o€
(!
r31 'È
G
È
ooF
00cq¡
Q)
.s 80
G
È^^(!bU
(¡¡s
(l
È
Eqo
È
(g
-o
20
525 -G
459 è
q¡
394 g
:zs È
R
¿oz (E
(¡)s
rot.S
(B
rsr à
(È
.è
66 r-
30
27
24
21
l8
15
12
I
b
3
0.1
Flow in gallons per minute (gpn), noninal7.9 16 24 32 40 ß 56 63
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
Flow in liters per second (Usec)
0.4 0.8 1.2 1.6 2.0
FIow in liters per second (Usec)
Flow in gallons per ninute (gpm), nominal10 19 29 38 48 51 67 76 86
PF75 Series, 50 H2,0.75 kW
0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0
FIow in liters per second (L/sec)
0.2 0.3 0.4 0.5 0.6 0.1
Flow in liters per second (L/sec)
0.8 0.9 0 2.4
40
e
$ss
's eo=abzs
!
Gt¡¡s20
(l'=È
Ers
È
.S to
Ê
l5
98
82
6ô
49
33
165
89-(È
ies
os b'(¡¡
a¿gtÈ(È
3e.Ë
C'
30F\
zoI(È
.o
?â
q¡
ql
=s
È(!
(¡¡q
(!
G
È
(E
Ê
G
o
(¡)e
Ès
È
G(¡¡s(t
G\È
G
.o
0
0
PF30 Series,50 H2,0.37 - f.1l kW
FF3oroEã
lPr3oos¡tl
\\s I
PF50 Series, 50 Hz, 0.37 - 1.fl kW
ffi
û
\
NTO-PU-PF-1
Bev.2.2, @ 09/14
Page 6 of 6
orenco Systemso lnc. ,814 Airway Ave., Sutherlin, 0R 97479 USA o 800-348-9843 . 541-459-449 . www.orenco,com
Orifice Shields
Applications
Orenco@ Orifice Shields are used ìn a pressurized distribution system
t0 protect the orifices from backfill debris that might cause orifice
blockage.
d
General
Orenco 0rifice Shields snap{it onto laterals, They may be placed on
top of or beneath a lateral, depending on the location of the orifice
Orifice shields are covered by method-of-use paient # 5,360,556,
Standard Models
0s075, 0s1 00, Osi 25, 0s1 50, 0s200
Product Gode Diagram
--T-*
II Lateral pipe size, nominal
075 = 0 75 in. (20 mm)
100 = 1,00 in. (25 mm)
125 = 1,25 in. (32 mm)
150 = 1 ,50 in. (40 mm)
200 = 2.00 in. (50 mm)
0rifice shield
Material of Gonstruct¡on
PVC per ASTM D-1 784
Physical Specif ications
/
\"
\
r*é,
0s
ùrifice shield instatled on lateral pipe, standard configuration
Shield
0rifice
Cutaway view, standard configuration
0rifice
Shield
Cutaway view, cold weather configuration
Model Shield 0.D.
in. (mm)
Lateral pipe 0.D.
in. (mm)
0s075 3.5 (8e)1.05 (27\
0s1 00 3.5 (89)1 .315 (33)
0s1 25 3.5 (8e)1.66 (42)
0s1 50 4.5 (1 14)1 eo (48)
0s200 4.5 (114)2 375 (60)
Orenco Systems@ lnc. , 814 Airway Ave., Sutherlin, 0R 97479 USA . 800-3¿18-9843 o 541 -459-¿1449 . wwworenco.com NTD-SF-0S-1
Rev.l.1,@09/f4
Page 1 ol 1