HomeMy WebLinkAboutApplication- PermitGARFIECD COUNTY Bt{71gING MW SANITATION DEPARTMENT Permit %_ 3 8 81
T 109 8th Street Suite 303
Glenwood Springs, Colaradp801
Phone (303) 945-8212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Owner's NemA t b
A System Location
A
Legal Description of Assessor's Parcel No
4 SYSTEM DESIGN
'533 CIL 335
Assessor's Parcel No.
This does not constitute
a building or use permit.
resent Address) OLD NV‘
tLr& Phhine R— 07q7
o�S 4 70/cpOlei
r
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other)
Required Absorption Are
Special Setback Requirements:
Date Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
1
System Installer
Septic Tank Capacity r.
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements
Other
Date c:�l(p-aV Inspector ajna
RETAIN WITH RECEIPT RECORDS AT C elf TRUCTION SITE
•CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs,alters, or installs an individual seWage disposal system In a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine —6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
r
OWNER ' G Air c_ F ,c _,. /7/6,9iA
ADDRESS 772 h O1 7 , S;pfrr 72 PHONE Yr -0797
CONTRACTOR' nicr.-h as --
ADDRESS c033 C.il>.- r 01,11 PHONE ?fl 57%8"
PERMIT REQUEST FOR (6 W INSTALLATION ( )ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town
Size of Lot /0 a c res
#
Legal Description or Address RU S'k{ 5'&ir %d k rs �c hm/d teat
I /v
WASTES TYPE:
($) DWF.I LING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER - DESCRIBE .0
BUILDING OR SERVICE TYPE: S/F ttG a j
1------rrmm•u---aasu5tr
Garbage Grinder
Automatic Washer Dishwasher y'
smisassaibta (4 WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
A site plan is required to be submitted that indicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System to Property Lines: (septic tank &leach field)10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
2
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
('4 r‘
SEI!TIC TANK ( ) AERATION PLANT
( ) VAULT PRIVY ( )
( ) PIT PRIVY ( )
( ) CHEMICAL TOILET ( )
FINAL DISPOSAL BY:
( ✓� ABSORPTION TRENCH, BED OR PIT
( ) UNDERGROUND DISPERSAL
( ) ABOVE GROUND DISPERSAL
( ) OTHER - DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? /Ye
PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the
Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole NO. 3
Minutes per inch in hole No. 2 Minutes per inch in hole NO. _
Name, address and telephone of RPE who made soil absorption tests:
VAULT
COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
INCINERATION TOILET ( ) RECYCLING, OTHER USE
OTHER - DESCRIBE
( ) EVAPOTRANSPIRATION
( ) SAND FILTER
( ) WASTEWATER POND
Name, address and telephone of RPE responsible for design of the system:
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed ,4 g Date /0 -�1/- 0,3
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
1`
1
1.
1
1
1
1
1
1.
1
1
1
GARF I ELD COUNTY
9708043470
01/09/04 08: 20••• P. 002
go be nt czx rg10-ozk c-sy9'?
ei�n c0 COMM DfNuss ATo swat= ov*RTll6e r.a P1! - .1881
710 ea sweat sail. 31118
efaN.ea- epafalri. Cando *NM
insP
�J i ena 1�X21M2
C1L35
nNOPerrr
Span LoW2011 % , ` ! Zto AithiLLKDAc
Lays onwlosal of Ayeewb Paan was _____ . — 3W4a
— X r I
I d done. /2 -Ao -b3 7e
asenem'a Peed la
Sena
This doss not soa r
a Wading or a dont
s_ u* WPM —
Peroolaian Ras
Papienon
avecial
Dale
nolltnntor
MAL SYSTEM 9 OM AND Arr.olAl. (a bag Sd)
Call for Inspection (24 hon notice) Before Cosine Installation
Spar, Insbner
septic raw awaab0
Septic Tank Man Iia sr w Trade Naar
Sonde Tank Awed within t of twin
Absorption Mas
Absotptbn Aron Typo and/or MentAnww or Trade Nacos
Adeaaam aakpaeice Pial County and star weyldapotalraquhsMada._ ••
Othw
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION 817E
+CONOITIOMO:
1. M kramaaeaspoutteem9iywMapresdosnienleWlneCaiaade8UaaOaaAotHSSI acwwImlSewage aspOtaiWows Cnaarr
25. ASS ID C.R.S.1973. Raised 1901.
2. JIS penMl Maid oteatatasmstion OldaiMa.MIdIMaeRdyawgBtlwMCaaM9mdd9#tlfaW_Mta.i.msta Con-
naotiento oroeaadlw7-MgaraMailumoU0t. tmmd Wee Vidlernamtaratkigellkiasaireetreatellebeavieletlesiaa
neabwhaal of the MS and aaae 4r both Huai Slaw and rosialloti at 1M pest
3. Mr weaawh0wnMiaob. sum otiaabMaanindMdual adpelsowafyaww a sdnnwwaieh _. to a4awkl0one maawlw
also from tip e-msw aweaalaallasa atlntoined is 11111110011111911114111,1111111 awswe a ars 1. Pati/ Mime MM. One —a
enmities in Oil or both).
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1•
1
1
1
rrep.alpr
FINAL SYSTEM I MW APPROVAL (ac installed)
Call for Inspection (04 hews notice) Before Covering Installation
System moaner
Sept* Task Capeohy
Septic Tens kkmdicaeer Of Trade Nsa
Septic Tank Awes, wither r of solves
nisrpean Area
Maar Prion Nee Ts ardor aarleoarrar ar Trade Nene
ARMS* rnishri nse with Cway and Side Isoulallonslmotreiments
Oliver
Oche Inspector
RETAIN WITH RECEIPT RECORDS AT COwstnuan N SITE
•CONINT10NS:
1.
the inseam rauwtemp* with ea requirensasaarCotorado Serie Sod etMoth Individual Swage disposer System Chapter
W. Ardent 1O .R.S. 1973. Revised twee.
2. Thispmri Acrd only [wwreretlentadinn ureawddeiiweullreasp2MrM/rCoud/andesendWMng mginmente. Con-
neetIoawersediearo drslerrgorseesapeaaraprowdlo etrAN`taedZordeUMRea/apadamofaegkeauiuISen tea
rea.drw.sw al the peS and amuse ler bale lewd aoUee mail asooderdel � �Wen.
_ wawa
3. A prserswkeeaadnroY. enne.orinelseesn indNoa
ideal dispetin.rar in a ownwentobinratesairrsw4g end maid
.aider. Item the erne sandlessineseontatned le spa et ponds erusdts a Cans 1. Petty Odes I00.sa ane—a
mortis in heli ot both).
Veit
ftUli,;:
,cpfbic - 4.3 /
ED
2004
g.N7y
ANNING
Garfield County Planning & Zoning Department
108 8's Street
Suite 201
Glenwood Springs, CO. 81601
Attn: Andy Schwaller
Dear Mr. Schwaller,
255 Vista Valley Drive
Fruita, CO 81521
Voice: 970-858-7373
Cell: 970-260-9082
Fax: 970-858-7373
Email: rwjhjjCbresnan.net
Robert W. Jones, 11, P.E.,
President
January 27, 2004
Re: ISDS Design Submittal
Albright Residence
0585 Cindy's Way
Rifle, CO 81650
Tax ID# 2127-334-00-188
Please find enclosed for your review, one (1) copy of the engineered ISDS report, prepared by Vortex
Engineering, Inc., dated January 14, 2004, revised January 26, 2004 for your review and approval. The
items discussed in our conversation on January 26, 2004 have been reviewed and the applicable revisions
in the report have been completed.
Upon your review, should you have any questions or comments, please do not hesitate to contact me at
970-260-9082.
Cc: Gene & Penny Albright w/ encl.
Lyn Herniesen, Rifle Premier Homes w/ encl.
Vortex Engineering, Inc.
4>
Robert W. Jones II, P.E.
C:My DocumentsNatex Engmeering ProjectsBifle Premier Homes/Albright Residence/Andy Schwaller letter I-27-04.doc
1
Date: January 14, 2004
1 Revised: January 26, 2004
I Prepared by: Robert W. Jones II,P.E.
Vortex Engineering, Inc.
255 Vista Valley Drive
1 Fruita, CO 81521
970-260-9082
Type of Design: New Residential
Owner: Gene and Penny Albright
0585 Cindy Way
1 Rifle, CO 81650
1 Property address:
255 Vista Valley Drive
Fruits, CO 81521
Voice. 970-858-7373
Cell. 970-280-9082
Fax: 970-858-7373
Email: rwjhjjfabresnan.net
Robert W. Jones, 11, P.E.,
President
INDIVIDUAL SEWAGE DISPOSAL SYSTEM DESIGN (ISDS)
0585 Cindy Way
Rifle, CO 81650
Tax schedule No.: 2127-334-00-188
1
1
1
1
1
Albright Residence ISDS Report Page 1 of 8
Vortex Engineering, Inc F04-001
1.0 Introduction/Site History
The site consists of approximately 10.0 acres of naturally uncultivated native soils.
Sparse Sage Brush and natural vegetation covers the parcel. Drainage is from west to
east in the area of interest. A natural drainage swale is approximately 100 feet north of
the proposed septic area. This swale is only active during times of heavy rainfall. A
percolation test/soils evaluation was completed on site by the Garfield County Building
and Sanitation Department, David Mead, on December 10, 2003. In accordance with the
results from this test, the following engineered design of an individual sewage disposal
system (ISDS) has been prepared. Results from the 12/10/03 test are attached for
reference as Appendix `A'.
2.01SDS Design Parameters
The perc test excavation was extended to a depth of approximately 120" below the
natural ground surface (BGS). There was no evidence of ground water or high seasonal
water table in the open excavation to a depth of 120" BGS. The soils evaluation
indicates soils underlying the site are relatively homogeneous. A more geological
description follows:
Depth (in.) Description
0"-120" medium -hard silty clay
Three perc test holes were constructed and tested at varying levels BGS. Perc test
results for the holes are as follows:
Perc hole # Perc rate
1 40 minutes/inch
2 80 minutes/inch
3 80+minutes/inch
**Average perc rate = 66 minutes/inch.**
The average perc rate was utilized as the design perc rate, which is equal to 66
minutes/inch.
The facility proposed on the parcel which will be utilizing the ISDS is a four (4) bedroom
residential modular home approximately 1,700 S.F. in size.
3.0 ISDS Svstem Design
An Infiltrator chamber absorption field is proposed for discharge of septic effluent at the
site. As shown in the attached ISDS Site Plan, the Infiltrator chamber system will consist
of (76) seventy-six standard infiltrator chambers for a total of 475.0 feet of trench. Each
trench is 36" wide and approximately 36"-48" deep. Four trenches 93.75' long and one
trench 100' long will be excavated and installed with infiltrators in series. A laser level
shall be utilized during construction to ensure a level trench plane. Each Standard
Infiltrator Chamber is 34" wide, 75" long, and 12" in height with a storage capacity of
77.5 gallons. Posi-Lock end plates will be utilized at the end of each trench chamber.
Albright Residence ISDS Report Page 2 of 8
Vortex Engineering, Inc F04-001
Adjacent trenches shall be separated by a minimum of 6 feet horizontal distance of
undisturbed soil. The infiltrators are to be installed in the center of each trench and level
(end-to-end). The infiltrators are to terminate 12° from the ends of each trench.
Septic effluent distribution piping to the absorption field will consist of a 4" PVC solid
discharge line. As shown in the attached Plan and profile views of the Infiltrator system,
the serial distribution connection between adjacent trenches will assure the up -gradient
absorption trench is completely filled before effluent is discharged to each consecutive
down -gradient absorption trench.
Native soil will be used to backfill the trenches after the infiltrator systems have been
installed. The native soil backfill will be mounded at least 5% over each trench to
promote adequate surface drainage in the vicinity of the absorption system.
The installer should confirm the feasibility of gravity discharge of sewage effluent form
the structure to the absorption field by field verification of assumed design parameters.
Assumed design parameters with respect to gravity discharge include, but are not limited
to:
A) Elevation of ground surface at entry to absorption field must be no less than 16"
above the invert elevation of sewage pipe at exit from foundation line.
B) The distance from the exit of the sewage pipe at the foundation line to absorption
field is 110' or less.
C) Solid distribution piping for the effluent is to be installed at a grade of 2%
minimum.
If field measurements do not confirm these design assumptions, gravity discharge of
septic effluent from the proposed structure cannot be assured and a lift station may be
required. Please contact the design engineer and GCHD to address any design
modifications necessary if these design assumptions are not upheld.
The installer must also confirm the setbacks from the property lines, building envelopes,
streams, and existing easements shown in the attached plans are maintained.
Additionally, any unknown utility lines, easements, or other adverse conditions disclosed
during construction must maintain the required setbacks listed in Appendix 'B'.
A 1,250 gallon septic tank is required for septic effluent from the proposed four bedroom
home. As discussed above, an Infiltrator chamber system absorption field is proposed to
discharge septic effluent to the underlying sub -surface. As depicted in the attached ISDS
plan and profile drawings, the absorption field will consist of four trenches 93.75' long
and one trench 100' long installed with infiltrators in series, each 3' wide and
approximately 36"-48" deep. The total effective trench infiltration bed area is 2,356
square feet after reduction factors are applied. There will be 76 standard infiltrator units
utilized for this Septic field. Calculations and design parameters used to size the
Infiltrator Chamber system are as follows:
Albright Residence ISM Report Page 3 of 8
Vortex Engineering, Inc F04-001
DESIGN CALCULATIONS
AVERAGE SEWAGE FLOW FOR 4 BEDROOM HOME OF 150 GAL./BEDROOM-DAY
4 BEDROOMS X 150 GAL./BEDROOM-DAY = 600 GAL./DAY
PEAK FLOW = 150% OF AVERAGE = 900 GAL./DAY
DESIGN PERCOLATION RATE = 66.0 MIN./INCH
A = Q/5*(4t), WHERE,
A = ABSORPTION FIELD AREA
Q= PEAK FLOW
T= PERC TIME/INCH
A = 900/5'J66.0= 1,462.32 SQUARE FEET
INCREASE ABSORPTION AREA BY 40% FOR CLOTHES WASHER, AND 20% FOR
GARBAGE DISPOSAL
DESIGN AREA= 1,462.32 x 1.6 = 2,339.72 SQUARE FEET
DECREASE TRENCH AREA BY 50% FOR INFILTRATOR CHAMBER SYSTEM TRENCH
AREA REDUCTION ALLOWANCE
ADJUSTED TRENCH AREA = 2,340 S.F. *(0.50) = 1,170 S.F.
STANDARD EFFECTIVE INFILTRATOR AREA PER UNIT = 15.50 S.F.
NUMBER OF INFILTRATORS REQUIRED = ADJUSTED TRENCH AREA
(15.50 S.F.)
NUMBER OF INFILTRATORS REQUIRED = 1.170 S.F. = 75.48 UNITS
(15.50 S.F.)
DESIGN TRENCH LENGTH = 76 X 6.25 = 475'
DESIGN TRENCH LENGTH = 4 TRENCHES @ 93.75' + 1 TRENCH @ 100.00' = 475.00'
SEVENTY-SIX (76) STANDARD INFILTRATOR CHAMBER SECTIONS TO BE UTILIZED
Albright Residence ISDS Report Page 4 of 8
Vortex Engineering, Inc F04-001
4.0 Site Specific Installation/Operation Requirements
The owner and system contractor shall be aware and comply with the following
installation and system operation requirements.
4.1 Installation -Setbacks, Notifications, and Inspections
• The system contractor must be approved and licensed by the Garfield County
Health Department for ISDS installation.
• All installation activities shall be conducted in accordance with current Garfield
County Health Department & State of Colorado Board of Health Department
ISDS regulations. If at any time during construction, subsurface site conditions
are encountered which differ from the design parameters developed in Section
2.0, construction activities will stop and the design engineer and Garfield County
Health Department will be contacted to address any necessary design
modifications.
Installation procedures including grade, location, setbacks, septic tank size, and
absorption field size shall conform with the attached graphic details. Construction
activities and system components will not encroach upon existing easements or utility
corridors. A minimum of 6 ft of undisturbed soil shall be maintained between individual
absorption elements and the septic tank and//or adjacent absorption elements.
• To avoid surface flow infiltration and saturation of the new absorption system,
abandonment of irrigation in the vicinity of the disposal system is required.
Diversion ditches necessary to divert surface flows around the new absorption
bed must maintain the minimum setbacks listed above.
• All sewer lines and effluent distribution piping shall be 4 inches in diameter, have
glued joints, and employ a serial distribution connection between adjacent
absorption trenches. Septic tank effluent lines shall b e placed level in the
absorption field. All lines discharging sewage from the residence to the septic
tank shall maintain fall of between 1/8 in. and 1/4 in. per foot and shall employ
sweep 90's or 2-45's at all tums. Sewer lines from the dwelling to the septic tank
and at least 6 ft from the septic tank outlet must meet minimum standard ASTM -
3034. Sewer lines under driveways shall always meet minimum Schedule 40
PVC standards and shall be encased with corrugated metal pipe when covered
with less than 24" of soil.
• The installer shall not place fill in the open excavation until inspected and
approved by the design engineer. Additionally, the final cover shall not be placed
on sewer lines, septic tank, or the absorption area until the system has been
inspected and approved by the design engineer and the Garfield County Health
Department.
• The installer shall provide 48 hour notice to the engineer and the Garfield County
Health Department for all required inspections.
Albright Residence ISDS Report Page 5 of 8
Vortex Engineering, Inc F04-001
• The surface cap shall be mounded 5% over the absorption trenches to promote
surface runoff.
• The system contractor shall be aware of the potential for construction activities to
reduce soil permeabilities at the site through compaction, smearing, and
shearing. The following precautions and construction procedures should be
employed during installation to minimize disturbance to native soils.
I. Excavation should proceed only when the moisture content of the soil is
below the plastic limit. If a sample of soil forms a rope instead of crumbling
when rolled between the hands it is too wet and should be allowed to dry
before excavation continues.
II. Excavation and backfill equipment should work from the surface where at
all practical to avoid compaction of the solids at depth.
III. The bottom and sidewalls of the excavation should be left with a rough,
open surface. The appearance should be that of broken or ripped soil as
opposed to a sheared, smeared, or troweled surface. Any smoothed of
smeared surfaces should be removed with a toothed rake or shallow ripper
taking care to remove loose residues for the bottom of the trench by hand if
necessary.
IV. Care should be taken in placing fill materials in the excavation to avoid
damaging the exposed soil surfaces.
4.2 Operation -Maintenance and Inspections
• The owner shall install a structural barrier if necessary and take precautions to
prevent vehicular traffic, excessive surface watering, accidental flooding, or other
activities in the vicinity of the absorption field which may compact, saturate, or
otherwise alter the subsurface soil parameters used in designing the septic
system.
• The owner will plant and maintain grass or other shallow rooted cover crop to
prevent erosion and promote evapotranspiration over the absorption field.
• The owner will inspect and maintain the required mounding and drainage away
from the absorption field to prevent saturation from precipitation and surface
flows.
• To mitigate the generation of preferential flow channels which may compromise
the operation of the system, the owner will inspect and prevent intrusion of
burrowing animals and deep rooted plants into the absorption field.
• The owner will conduct periodic maintenance of the septic system by removing
accumulated sludge from the septic tank every 3-4 years or as necessary to
prevent clogging of the absorption field.
Albright Residence ISDS Report Page 6 of 8
Vortex Engineering, Inc F04-001
5.0 Limitations/Restrictions
This report is a site specific design for installation of an individual sewage disposal
system (ISDS) and is applicable only for the client for whom our work was performed.
Use of this report under other circumstances is not an appropriate application of this
document. This report is a product of Vortex Engineering Incorporated and is to be taken
in its entirety. Excerpts from this report may be taken out of context and may not convey
the true intent of the report. It is the owner's and owner's agents responsibility to read
this report and become familiar with recommendations and design guidelines contained
herein.
The recommendations and design guidelines outlined in this report are based on: 1) the
proposed site development and plot plan prepared by Sexton Survey as fumished by the
client to Vortex Engineering, Inc., 2) the site conditions disclosed at the specific time of
the site investigation of reference, and 3) the perc test report prepared by the Garfield
County Health Department. Vortex Engineering, Inc. assumes no liability for the
accuracy or completeness of information furnished by the client. Site conditions are
subject to external environmental effects and may change over time. Use of this plan
under different site conditions is inappropriate. If it becomes apparent that current site
conditions vary from those anticipated, the design engineer and GCHD should be
contacted to develop any required design modifications. Vortex Engineering, Inc. is not
responsible and accepts no liability for any variation in assumed design parameters.
Vortex Engineering, Inc. represents this report has been prepared within the limits
prescribed by the owner and in accordance with the current accepted practice of the civil
engineering profession in the area. No warranty or representation either expressed or
implied is included or intended in this report or in any of our contracts.
SEAL
Robert W. Jones, II, P.E.
President
Vortex x Engineering, Inc.
IZ
Date 1—A9—e`h
Albright Residence ISDS Report Page 7 of 8
Vortex Engineering, Inc F04-001
APPENDIX A
SOILS AND PERCOLATION REPORT
GARFILED COUNTY HEALTH DEPARTMENT
Albright Residence ISDS Report Page 8 of 8
Vortex Engineering, Inc F04-001
APPENDIX B
TABLE OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN
COMPONENTS OF A SEWAGE DISPOSAL SYSTEM
1
1
1
1
1
1
'�
o
'?
b
9
2
h
h
i
I
I
,,Ie��e��nlI
p "
6-
•6A
6A
o
10
0
0
x0
G
ga
61
ii2 g 6A
toy
it
S2
a2
A
A
A
A
A
a
12
=1.
1
o
e
0.
0
0
0
0
o
0
pe
.1:8g y
J1
rens
P,6
2
2
2_
o
2
9
..
la Ca
n
20
n
^
.e...
orsen
^
Zvi
o
Potable Water
Supply
Cistern
n
a yp
O.J.1
6 N
tg
:a
Et0
60
60
O
O
N
2
h
E.'..
.R
h
1I
1
g
g
�JI]
b
t1111
ii
Unlined or Pushily Lmed
Bvepoannepbadon Sys Wanseaer
Pad, ar Sodom Disposal Syaem Other
than Sari
]
Lined Evapotranspiration Field ar Lined
Wastewater Pond
1
111
La I
.Led d
gig j
el
bag
121
ig 1
.�tr] ll
C C 1
siRt° I
g; n a
9
111
2
ffil
I.
itt
gi its 18
iC T9 tr :
5 1g a
•so '� 5 b
I _ b s
e a
�W '�
i 8 0
11` 1 1Y 1
haps
41 11I1
9 1
.� Y O
e b
�lid
I 9 $f6 1 1
11' 1 $s
110 11ILII 111
: I
:giltI seed
o
s E1I 6
00
1
Serial Distribution
Same -End Inlet
Pan View
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Na b gab
Septic
Tank
Standard Chambers
4" PVC Pipe
Cbsed End Pat.
Serial Distribution
Same -End Inlet
Cross Sectbn
Nab Sake
Surface Grade
PVC Ptps
Cbsed End Pat* (Typ.)
IMS PIANM
REFERENCES A OE
BY MRLTRATOR SIMM. PC.
2.) TMS PUN 6 NOT 10 RE RAZED
AS A REFERENCE FOR ANYIHOIG OVER
AND SPECi1CAp16 t:01REt:11011s
3.) CONIRICTOR 6 10 WOO TME SNE
UIVUT PUN FOR SPWEE mesas OF
INFURATOR TROCHES AND ORENUM M.
Esabfah Vegetative Cover
Same -End
High Level Ovedbwv
Number d
Trenches
per Design
TITLE:
INFILTRATOR DETAILS PLAN
SCAtL(H) N/A
M N/A
DATE
1-20-04
DRAWN BY:
R.JJI
CPO ID. #25Ds_SnE
PROJECT jF04—o0I
ORTEX ENGINEERING,INC.
•CML & CONSULTING ENGINEERS •PROJECT MANAGERS
•SITE PLANNERS•HYDROL.OGIC ENGINEERS* CONSTRUCTION MANAGERS
255 VISTA VALLEY DRIVE
P6: (970) � 90822COLORADO
pFAX: (981521
o else -7376
PROJECT:
ALBRIGHT RESIDENCE
0585 CINDY'S WAY
RIFLE, COLORADO
(ISDS DESIGN)
2127-334-00-188
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
NOTE
CALL 1-800-922-1987 FOR UTILITY
LOCATES BEFORE EXCAVATING
78 STANDARD INFLIRATDR UNIT
REPLACEMENT FIELD
CLEAN OUT
5 STANDARD INFILTRATOR UNITS
EACH RDW
16 STANDARD INFILTRATOR UNITS
15 STANDARD IIfILTRA10R UMTS
25' DRY GULCH BUFFER
APPROXIMATE LOCATION OF DRY GULCH (TIP.)
DETAILED SITE PLAN
SCALE:(H)1"=30
0 N/A
DAIS 1-20-04
REV• 1-26-04
DRNMN BY:
R.J.II
CAD I.D. j7SOS-SITE
PROJECT 9:F04-001
VORTEX ENGINEERING, INC.
•CML & CONSULTING ENGINEERS •PROJECT MANAGERS
• SITE PLANNERS *HYDROLOGIC ENGINEERS • CONSTRUCTION MANAGERS
255 VISTA VALLEY DRIVE
FRU17A, COLORADO 81521
P8: (970) 280-9082 FAX: (970) 858-7373
PROJECT:
ALBRIGHT RESIDENCE
0585 CINDY'S WAY
RIFLE, COLORADO
(ISDS DESIGN)
2127-334-00-188
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A
-
0
U
A
GRAPHIC
wirer
SW51']YM
NOTE
CONTRACTOR/One IS 113 YYITNI
THE FOLLOIIINC SETBACKS
ABSORPTION RET 0 SEPTIC TANK
SPRINGS/VELLS IDD' S0'
(1STFRN
100' 50'
STREAM
100' 50
DRY ann.
25' SV
001ESTIC EATER INE 25'
10'
PROP
FL METER
PPPRO)aaATE
LDGTIGN OF PROP.
LEIl
05631'
WORM
200
It CAP
PLS 13501 I
si
NOTE:
CALL 1-e00-922-1907 FOR ROUT(
LOCATES FRE EXCAVATING
MOOS a•-,•tc
110 GOBI O Me A x 0100••01 a OMR
O 0000 a x m OVRAN1 INK x 101001E
TO SIM • MOM Ong MONO
x SIN a x COX PIM b x m CIK
• O1•RAre Ax 000.016.• Oa0
+RBI OR IR
10[x M1Y ax AR •//Q AT x O,•Ia
-- 10 0 00.1 It ND Me IN w' Se x
K 91 a ax OIH IR AT AT x Oa MN
Tare ac
Waft MOM 10010110naOM IM 0001010 MAVf
MIA WM t 111011110 001140 x eOl BMW YOSARY.
I FOIIIC
REBAR
• GP
PIS 13501
FOUND
REBAR
It GAP
PLS 10732
001.00
TITLE:
ISDS OVERALL SITE PLAN
SCALE(H) 1"=100'
111 �) N/A
DATE: 1-19-04 ‘
1-26-04
DRAWN BY:
R.J.II
CAD I.D. #:ISDS_SITE
PROJECT I.F04-001
�ORTEX ENGINEERINGINC.
s
•CIVIL & CONSULTING ENGINEERS •PROJECT MANAGERS
•SITE PLANNERS *HYDROLOGIC ENGINEERS• CONSTRUCTION MANAGERS
255 VISTA VALLEY DRIVE
F COLORADO
PA: (970)280-9082 FAX (970) 858-7373
PROJECT:
ALBRIGHT RESIDENCE
0585 CINDY'S WAY
RIFLE, COLORADO
(ISDS DESIGN)
2127-334-00-188
Feb 03 PS 04:44p Vortex Engineering, Inc.
•
970-858-7373
July 15, 2004
Via: U.S. Mail
Garfield County Planning & Zoning Department
108 8" Street
Suite 201
Glenwood Springs, CO. 81601
Attn: Andy Schwaller
p.2
255 Vista Valley Drive
Fruits, CO 81521
Voice: 970-8584888
Cell: 970-260-9082
Fax: 970-858-7373
Email:rjones@vorte:ceng.com
u8-com
Re: ISDS Construction Inspection
Albright Residence
0585 Cindy's Way
Rifle, CO 81650
Tax ID!? 2127-334-00-188
Dear Mr. Schwaller,
In accordance with Garfield County ISDS regulations, Vortex Engineering, Inc completed an inspection of the
ISDS system at the above referenced location on July 14, 2004. The constructed system was reviewed for
compliance to the plans and specification dated January 26, 2004. The installed systemtowas b as andund materials
b is
general
cospecifications. This firm verified slope,
general conformance with these plans and
utilized for the ISDS system.
Upon your review, should you have any questions or require further documentation, please do not hesitate to
contact meat 970-8584888.
Cc: Gene & Penny Albright, Owners
Premier H Iglpnght Residence/Andy Schwaller letter 7-15-04.doc
CMY ppcomentsNdte><EngNar®g Prints/Rine