Loading...
HomeMy WebLinkAboutApplication- PermitGARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 t INDIVIDUAL SEWAGE DISPOSAL PERMIT 4 PROPERTY Owner's Name System Location y, W u -r • Permit N: 3874 Assessor's Parcel No. This does not constitute a building or use permit. USti7alAAkpresent Address , ` ketCL3\1 ..9-1a�ti a 91/46 LI l 9Ce &» & // )n Sal- Legal Description of Assessor's Parcel Nos) SYSTEM DESIGN 5 , Septic Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Required Absorption Area - See Attached Number of Bedrooms (or other) d t, sr Special Setback Requirements: Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements Other Date �f- < ' - 3 Inspector ��. `l elet-r Qfiti— 7/0#74-5 (r 0 i k 1? L UO RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE S- 7 D iL Z a *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter I 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER 'Rk.4by ?kR50M4$ —' Sv3441 WU5CM4N1.j ADDRESS 00%1 tiekoew a Q 4uw.sAwueS,Cb e16$2 PHONEE19o)94S'-208q CONTRACTOR Mitt, U/oRK SPr ti$ �S , T'v C . ADDRESSM%VX 96St'*AsodD41,S1A 8/ia3 PHONE(tS)963-ztiZf PERMIT REQUEST FOR (y) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town 5 iCT // i Size of Lot I4 A.cREY Legal Description or Address (116 Bw 3 Etat, G **' S �L ca . th 9/4 5 2, WASTES TYPE: ( DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: ;Ala 4r ;1. r Number of Bedrooms ( WO Number of Persons TIC 0 04 Garbage Grinder ti) Automatic Washer ( )cDishwasher SOURCE AND TYPE OF WATER SUPPLY: ()4 WELL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Was an effort made to connect to the Community System? A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 4 % 1b T4E SetiT10— TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (X} SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? NO PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes � per inch in hole No. 1 Minutes 30 per inch in hole No. 3 Minutes er inch in hole No. 2 Minutes — r _ per inch in hole No. Name, address and telephone of RPE who made soil bso tion tests: Tf f & k i - Solo etwA i ?D (S y G en, watt Swo,tyJcs , Co 9/401 99-0 995-f- 4 8 8 -�+ Name, address and telephone of RPE responsible for design of the system: 4F- t J�Jesi4S twc P 6 se -t) QReak &.vs z'cs4io•9 Ivc/u2I_z4 goas.‘gteib1oaaAiwv fee S/sos on9z95 oS 99 Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and famished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed Date 9--2w03 PLEASE DRQ ACCURATE MAP TO YOUR PROPERTY!! r:. fieitsbe -t 3311 (7/ CR NK CONSTRUCTION • INCORPORATED 1129 -24- Road Grand Junction, CO 81505 970.245-0577, 970-257.7453 (fax) November 25, 2003 CERTIFICATE OF INSPECTION AND ACCEPTANCE Individual Sewage Disposal System Parsons/Husseman Residence 146 Bluebell Lane Silt, CO 81652 Lot 16, Peach Valley Orchard The individual sewage disposal system of reference was inspected on November 25, 2003. The system was found to conform with the plans and specifications set forth in the engineered sewage disposal system design for the aforementioned property prepared on November 16, 2003. Copies of the engineered plan may be obtained from the undersigned design engineer. Seal Thomas A. Cronk, P.E. 1129 -24- Road Grand Junction, CO 81505 970-245-0577 ,11•)��� CaP,R1'G PIANN NG a 1 1 CRONK 1129.24. Road tCONSTRUCTION Grand Junction, CO 81505 INCORPORATED 970.245.0577, 970.257.7453 (taxi 1 REVISED INDIVIDUAL SEWAGE DISPOSAL SYSTEM DESIGN 1 (ORIGINALLY PREPARED ON JULY 7, 2003) Date: November 16, 2003 Prepared by: Thomas A. Cronk, P.E. Cronk Construction Inc. 1129 -24- Road Grand Junction, CO 81505 245-0577 1 Type of Design: New Residence 1 Owner: Parsons/Hussemann c/o Ray Gotfredson 0089 Meadow View Ct Trim Work Specialties Inc. Glenwood Springs, CO 81601 P.O. Box 965 970-945-2084 (hm), 970-625-9100 (wk) Carbondale, CO 81623 970-963-2421 1 Property address: 146 Bluebell Lane, Silt, CO 81652 1 Tax schedule No.: RECEIVED IIFC 0 9 2003 ' Legal Descript: Lot 16, Peach Valley Orchard BAR; .L _ u ,: JuNTY BUILDING & PLANNING 1 1 Page 1 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.0 Site History The site consists of approximately 10 acres of cultivated native soils. Drainage in the area of concern is approximately 1% to the south. A perc test/soils evaluation was conducted on the property by the Hepworth-Pawlak Geotech on 04/04/01 to provide subsurface design parameters for a new individual sewage disposal system (ISDS). Tom A. Cronk, registered professional engineer (R.P.E.) inspected the site on 07/03/03. Based on results from the 04/04/01 pert test and the 07/03/03 site investigation, an engineered ISDS was prepared for the property on July 7, 2003. The ISDS absorption field was excavated at the site in November, 2003. Tom A. Cronk (R.P.E.) inspected the site and absorption field excavation on November 5, 2003. Standing ground water was observed in the open absorption field excavation at a depth of 114" below ground surface (BGS). The high seasonal water table was located at a depth off 96" below ground surfaced (BGS). In order to maintain a minimum of 48" of suitable filtration soil above the high seasonal water table, the bottom of the absorption field must be located no deeper than 48" BGS. Site topography, the proposed foundation elevation, and the location of the original perc test/soils evaluations dictate a lift station is necessary to maintain the required absorption field depth. A discussion of the site design parameters and the revised ISDS engineered design incorporating a lift station follow. The 04/04/01 perc results are attached for reference as Appendix A. The locations of the perc excavations are shown on the attached plot plan. 2.0 Development of Design Parameters The 04/04/01 soils observation excavation was extended to a depth of 96" below ground surface (BGS). As recorded during the 04/04/01 site investigation, there was no evidence of ground water in the open excavation to a depth of 96" BGS. The soils evaluation indicates two distinct soils horizon underlies the site. A lithological description follows: depth (in.) description 0" - 12" topsoil 12" - 96" medium stiff to stiff sandy silt and clay with stratified layers of silty sand A site investigation by Tom A. Cronk (R.P.E.) on 11/05/03 indicated standing groundwater underlies the absorption field at a depth of 114" BGS. The high seasonal water table is estimated at a depth of 96" BGS. An INFILTRATOR absorption field is proposed for the site. A design perc rate of 30 min/in. is chosen for overall system sizing. Page 2 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3.0 System Design A INFILTRATOR absorption trench is proposed for discharge of septic effluent at the site. In order to maintain a minimum of 48" of unsaturated filtration soil above the high seasonal water table (located at 96" BGS), the absorption field must be located no deeper than 48" BGS. To maintain the required absorption field depth, a lift station discharging into pressurized effluent distribution laterals will be employed to discharge septic effluent into the absorption field. Construction of the system will consist of excavating level trenches in the area comprising the absorption field. The initial excavation shall be continued to a depth ranging from a minimum of 36" to a maximum of 48" BGS (see absorption field cross-section). If the initial excavation is deeper than 48" BGS, the excavation shall be backfilled with sandy replacement soil (perc rate ranging from 5 min/in. to 40 min/in.) to a maximum depth of 48" BGS. Following completion of the initial push -out, INFILTRATORS will be used to construct a septic effluent distribution system in the open excavations. The INFILTRATOR effluent distribution system will be installed in accordance with the "Infiltrator Technical Manual", available from Infiltrator Systems Inc., 123 Elm Street, Suite 12, Old Saybrook, Connecticut 06475. Adjacent INFILTRATORS shall be fastened with a minimum of four (4) 3/4" x #8 self -tapping sheet metal or bright brass deck screws to prevent movement and separation during backfilling. As shown in the Construction Detail, the bottom of the INFILTRATOR seepage trenches will be located from 36" to 48" below ground level. The soil replacement/INFILTRATOR system will provide a minimum of 4.0 ft of usable infiltration soil between the septic effluent discharge piping and the HSWT located at a depth of 96" BGS. Septic effluent will be introduced into the INFILTRATOR absorption field through three pressurized distribution laterals installed in each row of INFILTRATORS as shown in the attached graphics. The injection laterals will consist of 1-1/2" Schd 40 PVC pipe with thirteen (13) 0.25" holes equally spaced along the 81.25' length of each row of INFILTRATORS (i.e., holes spaced 75" o.c. and beginning 37-1/2" and ending 37-1/2" from each end of the 81.25' run). Holes in the injection laterals will be drilled at 12:00 o'clock to direct effluent up for dispersal against the top of the chamber. Injection laterals shall be suspended from the top of the chamber with all weather plastic pipe strapping (min. 120 lbs tensile strength) at every chamber joint connection. The injection lateral will be suspended to provide a minimum of 1/8" fall per 12" run back to the pressure manifold to facilitate drainage of septic effluent or be buried below the frost line to prevent freezing (see attached construction detail). Septic effluent shall be introduced into the distribution laterals through a 2" (Schd 40 PVC) pressure manifold located at the end of the absorption trenches (see attached absorption field plan view). All pressure piping and mound construction shall be in accordance with the attached graphics. After the INFILTRATORS are installed, the absorption field will be covered with a soil cap. The soil cap will consist of 24" to 36" (10" minimum required) of native soil mounded 5% to promote surface run off away from the absorption field. The installer must also confirm the setbacks from property lines, building envelopes, and existing easements shown in the attached graphics are maintained. Additionally, any unknown utility lines, easements, or other adverse conditions disclosed during construction must maintain the required setbacks listed on page 6 of this document. A minimum of 12" (18" recommended) of soil cover is required for all gravity flow effluent piping, the septic tank/lift station, and the absorption field (excepting maximum 8" Page 3 of 9 soil cover over septic access ports). All non -draining pressure effluent piping must be covered with a minimum of 36" of cover to prevent freezing. A minimum 1,250 gallon, two compartment septic tank will be installed to provide a minimum of 30 hours retention time for sewage effluent from the proposed three bedroom residence. The 1,250 gallon tank will provide the required retention volume and still maintain sufficient room for installation of a filtered lift pump in the effluent discharge compartment. As discussed above, a soil replacement/INFILTRATOR system is proposed to discharge septic effluent to the underlying sub -soils. The second chamber of the septic tank will contain an Orenco Systems Inc (051) effluent pumping system employed to transfer effluent from the below -ground septic tank to the above -ground absorption system. The effluent pumping system will consist of a P500511 OSI pump with discharge filtration and associated components as shown in the attached effluent pump system detail. A 2" (Schd 40 PVC) pressure main will be used to transfer effluent from the septic tank to the absorption field. The pressure main must be constructed on -grade to drain back to the dosing chamber or be buried a minimum of 36" BGS to prevent freezing of retained septic effluent. All construction, dosing chamber capacity, location of ISDS elements, and setbacks from property lines, building envelopes, and existing easements shall be in accordance with the attached graphics. As discussed above, INFILTRATOR absorption trenches are proposed to discharge septic effluent to the underlying sub -soils. As shown in the attached graphics, the absorption trenches will consist of three (3) trenches 3' wide x 3' min .- 4' max. deep x 81.25' long with thirteen (13) standard INFILTRATOR units each for a total of thirty nine (39) INFILTRATORS. The absorption field will encompass a gross area of 731.25 square feet with an effective area (31 sq. ft. allowed area/INFILTRATOR) of 1,209 sq. ft. Calculations and design parameters used to size the absorption field follow. Page 4 of 9 DESIGN CALCULATIONS AVERAGE FLOW FOR 3 BEDROOM HOME ® 150 GAL.IBEDROOM-DAY 3 X 150 = 450 GAL.IDAY PEAK FLOW = 150% OF AVERAGE = 675 GAL.IDAY DESIGN PERCOLATION RATE = 30.0 MIN.IINCH A = -QV?, WHERE, A = ABSORPTION FIELD AREA Q = PEAK FLOW t = PERC TIME/INCH A = 655 30.0 = 739.43 SQUARE FEET INCREASE ABSORPTION AREA BY 40% FOR CLOTHES WASHER INCREASE ABSORPTION AREA BY 20% FOR GARBAGE GRINDER DESIGN AREA = 739.43x1.6 = 1183.09 SQUARE FEET SIZE ADJUSTMENT FACTOR OF 0.5 FOR INFILTRATOR TRENCH SYSTEM ADJUSTED AREA = 1183.09 X 0.5 = 591.55 SQUARE FEET USE 39 STANDARD (H-10) INFILTRATORS @ 15.50 SQ. FT. EACH FOR TOTAL ABSORPTIVE AREA OF 30 X 15.50 = 604.50 SQ. FT. ABSORPTION FIELD SIZED AT THREE (3) TRENCHES 3 FT. x 81.25 FT. = 731.25 SQ. FT. Page 5 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4.0 Site Specific Installation/Operation Requirements The owner and system contractor shall be aware and comply with the following installation and system operation requirements. 4.1 Installation - Setbacks, Notifications, and Inspections • All installation activities shall be conducted in accordance with current Colorado Department of Health ISDS Regulations as well as any relevant Garfield County regulations and requirements. If at anv time during construction, subsurface site conditions are encountered which differ from the design parameters developed in Section 2.0, construction activities will stop and the design engineer will be contacted to address anv necessary design modifications. • Installation procedures including grade, location, setbacks, septic tank size, and absorption field size shall conform with the attached graphic details. Construction activities and system components will not encroach upon existing easements or utility corridors. A minimum of 6 ft of undisturbed soil shall be maintained between individual absorption elements and the septic tank and/or adjacent absorption elements. Minimum site specific setbacks for system components are: Source Septic Tank Absorption Field Building Sewer water line 10' 25' 10' domestic well 50' 100' 50' dwelling 5' 20' property lines 10' 10' subsoil drains 10' 25' irrigation ditch open 50' 50' lined/gated 25 25' solid pipe 10' 10' • To avoid surface flow infiltration and saturation of the new absorption system, abandonment of irrigation in the vicinity of the disposal system is required. Diversion ditches necessary to divert surface flows around the new absorption bed must maintain the minimum setbacks listed above. • All sewer lines and effluent distribution piping shall be 4 inches in diameter and have glued joints. INFILTRATORS shall be placed level in the absorption field. All lines discharging sewage from the residence to the septic tank shall maintain fall of between 1/8 in. and 1/4 in. per foot and shall employ sweep 90's or 2-45's at all turns. Sewer lines from the dwelling to the septic tank and at least 6 ft from the septic tank outlet must meet minimum standard ASTM -3034. Sewer lines under driveways shall always meet minimum Schedule 40 PVC standards and shall be encased with corrugated metal pipe when covered with less than 24" of soil. Page 6 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 • The installer shall not place fill in the open excavation until inspected and approved by the design engineer. Additionally, the final cover shall not be placed on sewer lines, septic tank, or the absorption area until the system has been inspected and approved by the design engineer. The installer shall provide 48 hour notice to the engineer for all required inspections. • Four inch clean outs shall be provided at maximum 100' intervals in all gravity flow effluent lines exceeding 100' in length. • Replacement soil (if required) shall have a perc rate ranging from 5 min/in. to 40 min/in. as approved by the design engineer. Replacement soil shall be placed with moderate compaction to avoid settling but still preserve natural permeabilities [e.g., wheel compaction off dry soil (see moisture content comment below) with backfilling equipment in 12 in. lifts]. • The effluent distribution system shall be constructed in accordance with the "Infiltrator Technical Manual" available from Infiltrator Systems Inc., 123 Elm Street, Suite 12, Old Saybrook, Connecticut 06475. • Pressure piping shall consist of a 2 in. pressure main, 2 in. manifold, and 1 'A in. laterals. All pressure piping shall be min. Schd 40 PVC and have glued joints. • The septic effluent pumping system shall consist of OSI components (OSI effluent pump model no. P500511) as detailed in the attached effluent pumping system detail. The effluent pump control panel shall be Orenco model no. SIETM. Electrical wiring shall be continuous cable with all connections made in a weather proof box exterior to the dosing chamber. Limit switching shall consist of: 1) low level/pump off, 2) high level/pump on, and 3) high level alarm/system failure. The high level alarm shall be easily detectable by occupants. Emergency notification information (e.g., telephone numbers of owner, Mesa County Health Department, service personnel) shall be posted near the high level alarm. • The effluent pump shall be configured with a minimum dose volume of 200 gal. Storage capacity in excess of the high-level alarm shall be 6" above the pump -on float level. • All access manholes on septic tanks and dosing chambers will be child proof and contain appropriate warning labels if accessible to the public. Confined space entry precautions should be observed by maintenance personnel. • The surface cap shall consist of native soil mounded 5% over the absorption field to promote surface runoff. • The system contractor shall be aware of the potential for construction activities to reduce soil permeabilities at the site through compaction, smearing, and shearing. The following precautions and construction procedures should be employed during installation to minimize disturbance to native soils: i. Excavation should proceed only when the moisture content of the soil is below Page 7 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 the plastic limit. If a sample of soil forms a rope instead of crumbling when rolled between the hands it is too wet and should be allowed to dry before excavation continues. ii. Excavation and backfill equipment should work from the surface where at all practical to avoid compaction of the soils at depth. iii. The bottom and sidewalls of the excavation should be left with a rough, open surface. The appearance should be that of broken or ripped soil as opposed to a sheared, smeared, or troweled surface. Any smoothed or smeared surfaces should be removed with a toothed rake or shallow ripper taking care to remove loose residues from the bottom of the excavation by hand if necessary. iv. Care should be taken in placing fill materials in the excavation to avoid damaging the exposed soil surfaces. 4.2 Operation - Maintenance and Inspections • The owner shall install a structural barrier if necessary and take precautions to prevent vehicular traffic, excessive surface watering, accidental flooding, or other activities in the vicinity of the absorption field which may compact, saturate, or otherwise alter the subsurface soil parameters used in designing the septic system. • The owner will plant and maintain grass or other shallow rooted cover crop to prevent erosion and promote evapotranspiration over the absorption field. • The owner will inspect and maintain the required mounding and drainage away from the absorption field to prevent saturation from precipitation and surface flows. • To mitigate the generation of preferential flow channels which may compromise the operation of the system, the owner will inspect and prevent intrusion of burrowing animals and deep rooted plants into the absorption field. • The effluent pump filter shall be inspected and cleaned as necessary every six (6) months. • The owner will conduct periodic maintenance of the septic system by removing accumulated sludge from the septic tank every 3-4 years to prevent clogging of the absorption field. Page 8 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5.0 Limitations This report is a site specific design for installation of an individual sewage disposal system and is applicable only for the client for whom our work was performed. Use of this report under other circumstances is not an appropriate application of this document. This report is a product of Cronk Construction Incorporated and is to be taken in its entirety. Excerpts from this report may be taken out of context and may not convey the true intent of the report. It is the owner's and owner's agents responsibility to read this report and become familiar with the recommendations and design guidelines contained herein. The recommendations and design guidelines outlined in this report are based on: 1) the proposed site development and plot plan as furnished to Cronk Construction Incorporated by the client, and 2) the site conditions disclosed at the specific time of the site investigation of reference. Cronk Construction Incorporated assumes no liability for the accuracy or completeness of information fumished by the client. Site conditions are subject to extemal environmental effects and may change over time. Use of this plan under different site conditions is inappropriate. If it becomes apparent that current site conditions vary from those anticipated, the design engineer should be contacted to develop any required design modifications. Cronk Construction Incorporated is not responsible and accepts no liability for any variation in assumed design parameters. Cronk Construction Incorporated represents this report has been prepared within the limits prescribed by the owner and in accordance with the current accepted practice of the civil engineering profession in the area. No warranty or representation either expressed or implied is included or intended in this report or in any of our contracts. Thomas A. Cronk, P.E. Date )moa. )LZ,ctt73_ NOTE: This individual sewage disposal plan is meant to include the following six pages of graphics including: 1) plot plan, 2) septic layout plan, 3) absorption field plan view, 4) absorption field cross section, 5) cross section - effluent pumping system, and 6) effluent pumping system design. The plan is not to be implemented in the absence of these related graphics. In addition, results from the 04/04/01 percolation test and sons evaluation are included for reference as Appendix A. Page 9 of 9 60199 M./03.5.00S N89'24'18'E N L 3 Q ✓ 0 3= W U E2'(99 3.92 20.00N 1 —0__s 0 0 0 o z W Q Z 1 z u oto N v+T W N W LJ Z Z QQ> Z J LJ Ju N NW O J ZJ,dO UI LJ T J K .p O J 0 Q p 0 J D U d f_21N 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NOTE ABANDON FLOOD IRRIGATION WITHIN 50' OF ANY ISOS ELEMENT, TYPICAL BLUEBELL LANE T NOTE THE FOLLOWING SETBACKS MUST BE MAINTAINED SEPTIC TANK ABSORPTION FIELD SPRINGS 50' WELLS 50' CISTERN 25' STREAM/POND/IRRIG DITCH- 50' DOMESTIC WATER LINE —10' 100' 100' 25' 50' 25' N89'24'18'E 684 61' 15' uttrty 4 drainage easement soils profile pit percolation test hole, typ repair area L BL25', typ 2' schd 40 pressure main (see note addressing cover) min 1250 gallon septic tank with 051 Effluent Pump (Model P500511) in second septic tank compartment clean out NOTE PROVIDE MIN 12' COVER (18' RECOMMENDED) OVER ALL GRAVITY DRAINING EFFLUENT LINES AND MIN 36' FROST PROTECTION COVER OVER ALL NON -DRAINING PRESSURE LINES, TYPICAL absorption T'eld with Pressurized distribution system consisting of three (3) rows of thirteen (13) standard Infiltrator units (36')(75' ea ) for a total of thirty-nine (39) units NOTE CALL 1-800-922-1987 FOR UTILITY LOCATES BEFORE EXCAVATING PARSONS/HUSSEMANN RESIDENCE 146 BLUEBELL LANE, SILT LOT 16, PEACH VALLEY DRCHARD SEPTIC LAYOUT PLAN NOVEMBER 12, 2003 NORTH SCALE 1'=40' O al S p O L L Y � tl p a 2 U -S rv4 o ao 23^OLI, S o O U CS N • 6 d L OJ L u a O O * tl 0- , i O aLL a O SCHD 40 pressure MQV1 dRp uiu,ZCy L 0 Y ,O tl SLL ✓ O OLL— / a [LL NOS 6 C 0 0 o a o US SN U ON Edit N g ✓ 11 d O N S N u >.' c o L Sr O L a a« SCHC 40 pre N. O ii NS m :pm L vm:3 NL aLL w^ 0 1 s a 0 tl t— w L 3 r/ CO N U O 0 n T 1S+ L1, nLL uL O L y O O L 4._ 4,1 N a N�-O� o o.- LY L44_ n Li Os = o c E N L - ., a,iptld sLLt_¢ o map tl LL NDO LOrr C o « L ✓ N 0 N 3 a L a.] U 01 IP t ¢N N O 0 O m iu 3 - c _ 0 p N N m U L O 0 K Z o w uw A o'> n - oz cy N W z J¢ z a aAo E > J o La wN n u in u ni o i wz ti 1— z ,pa£ o -a w r �>a a omou a - J a z ✓ 1 1 1 1 1 1 1 1 1 1 1K 1 1 1 1 1 1 1 1 1-1/2' SCHD 40 PRESSURE LATERALS WITH 1/4' HOLES SPACED 75' O.C. AT TOP OF PIPE TO DIRECT DISCHARGE UP FOR DISPERSION AGAINST TOP OF CHAMBER, TYP ONE OF THREE PROVIDE VENTING/INSPECTION PORTS AS REOUIRED BY INFILTRATOR INSTALLATION GUIDELINES, TYP EACH ROW CONE OF THREE) SOIL CAP (MOUND 57,) EXISTING GROUND SURFACE 36' DISK UR SCARIFY UNDER --- 72' MIN, TYP - —4 INFILTRATOR, TYP INFILTRATOR, INSTALL IN ACCORDANCE WITH 'INFILTRATOR TECHNICAL MANUAL, INFILTRATOR SYSTEMS INC, 123 ELM STREET, SUITE 12, OLD SAYBROOK, CONNECTICUT 06475 2 ABSORPTION FIELD — CROSS SECTION SCALE' 1'=5' SUSPEND PRESSURE LATERAL WITH ALL WEATHER PLASTIC PIPE STRAP WITH 120 LBS TENSILE STRENGTH AT EVERY CHAMBER CONNECTION, TYP. PROVIDE MIN. 1/8' FALL PER 12' RUN FOR DRAIN BACK TO DOSING CHAMBER OR BURY BELOW FROST DEPTH TO PREVENT FREEZING, TYP. 12 SOILS LOG (SEE NOTES) SOILS LOG NOTES #t - TOPSOIL k2 - MEDIUM STIFF TO STIFF SANDY SILT 6 CLAY W/STRATIFIED LAYERS OF SILTY SAND NO GROUNDWATER TO 96' BELOW GROUND SURFACE 4' SCHD 40 PVC VENT/INSPECTION PORT, TYP. 1 OF 6--\\71 SOIL CAP JT=I I I-III=1 3/4' THREAD CAP 1-1/2' SCHD 40 PVC PRESSURE LATERAL WITH 1/4' HOLES SPACED 75' O.C. AND DRILLED AT TOP OF PIPE TO DIRECT DISCHARGE UP FOR DISPERSAL AGAINST TOP OF INFILTRATOR 3/4' THREAD NIPPLE TO SURFACE FOR CLEAN OUT AND PRESSURE BALANCING DRILL END PLATE, CAULK, AND CAP 3/4' THREAD TEE PRESSURE LATERAL CONSTRUCTION DETAIL SCALE: 1"=1' PARSONS/HUSSEMANN RESIDENCE 146 BLUEBELL LANE, SILT LOT 16, PEACH VALLEY ORCHARD ABSORPTION FIELD - CROSS SECTION NOVEMBER 12, 2003 SCALE AS SHOWN 1 1 1 1 1 1 1 1 1 1 1 VgU .723 42 E /nl w 0 w 0 3 z c ¢ a LJ < .- m un m m n 0 CL LJ (541) 459-4449 N Q n .".L L NTN -oL dt.-VN ▪ E a >V • E N E '0 Gy) °' dL co -5v 3 a s O '-dCID jN (1 3 x O O OO 1,5 I) U0N N c oNOUN =0 n N c� vOEE ON er a O (1) =mv a nOOa :x 2 miau_ w P Tank Adapter (cast or bolted) 0) a d co E� v = a O O 0' of > d u cOOC C No N J Jd -' CJ > c U J>m Lied CJL > O OM: l.- -t 0 a O Biotubee Pump Vault II-III-IIL- �iT O c v = O 01 Jr c 0 -c w 3 t] O N N -0 J E 173 E )▪ •-•-• o c 0 U • C a 'c N O U U u C'j . O p Cr C N c y y a) rn a = • E L O O V U > ▪ = 0 * 0 -' N Q▪ 'tri C g • c O N• O ' N M 0 O dc U ▪ d O �d O N c cOnn d m cn O p awO u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Pump Selection for a Pr ssuriz d System PARSONS/HUSSEMAN PROJECT 146 BLUEBELL LANE, SILT, CO 81652 1-0°- I. 0 814 AIRWAY AVENUE SUTHERLIN, OREGON Si g 0 U O c O E _.1..__, TRuent Pumps P50 Series 1/2 hp to 1-1/2 hp; I ; 1_t i 1 y, ,' "' ' 1 l 4 , 1 ... ,,,,, o I � ,r, ,_o io I `- -------_-. ,., LL „ 1 ,_,.' ILL 0 0 8 8 3ee1 '(HUL) PoOH 0iweu60 18301 CD y 0 r Input Parameters N w L Oa o'g e u r_ 1) 0 fig€ 2£�51 N S♦ 0 m R O= oo 01 U 0 m v N g N g @ N eNJ 0o3QWam tzU cNm c ch OamN3J J _N_,J vE l g mM Ill�lliyLLUJ p N 0 a 5 a ru n p 0 C i ll 2 g Sa w z 3 m P cc g e N CD 0, N 0 0 Net Discharge, gpm To 0 t o n e. - o o m o ti m0eio00 m !' o. O a vi o 0 E 0 N N N APPENDIX A SOILS AND PERCOLATION REPORT HEPWORTH-PAWLAK GEOTECH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Jun 30 03 07:36p Ray Gotfredson 970-963-2421 JUN -27-03 FRI 07:35 All G11C0 eORP. FAX N0. 9706259101 Ge�c�ted^1 April 4. 2001 Jill Winkkr P.O. Box 2361 Basalt, Colorado 81621 tl ywurtil.Pawhk Cwtrchutul, hn. 7030 C tread 154 lih.+w'ood qp Colorado a1401 neat: M. VMS Fax: 11711•94s.14.44 /inn filyttolirlidam Job ,1*. 101 255 Subject: Percolation Testing. Proposed Septic Disposal System, Lot 16, Peach Valley Orchard, 146 Bluebell, Garfield County. Colorado. Dear Ms. Winkler. M requested, a representative of Jlepwordt-Pawlaak Geosecboioal, loc. conducted percolation testing at the ribject site to evaluate the feasibility of an infiltration septic, disposal system. The results of our work are presented in this report. The work was done in accordance with our agreement for professional services to you, dated Man4 29. 2001. p.2 Y. U! A profile pit and three shallow backhoe pits bad been excavated at the locations shown on lig. 3. Percolation test holes had been dug and soaked by the client prior to our field work. The soils exposed in the percolation boles are similar to those exposed in the profile pit and consist of about 1 foot of topsoil overlying medium atiff to stiff sandy silt and clay with stratified layers of silty sand to the prof le pit depth of 8 feet. Groundwater was not observed in the profile pit sad the soils were slightly moist to moist with depth. Percolation tests were performed on April 2, 2001 by a representative of Hepworth- Pawlak Geotechnical, Inc. The percolation test results are presented on Table 1 The percolation test results indicate an infiltration rate between 24 and 30 minutes per ineh with an average of 28 minutes pet inch. Based nn the subsurface conditions observed and Ute percolation test results. the tested arca should be suitable for a conventional infiltration septic disposal system. If there are any questions of it we tray be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK G • - , INC. lordy Z. Manua Rev. by: DELI i7.Alksw attachments 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ..un 30 03 07:37p Ray Gotfreason Jai -27-03 FRI 07:35 All GItCO CORP. Lf4u-IA0J-e,ieA FAX Ima. 9708259101 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS r. uo P•' J08 NO. 101 255 HOLE NO. HOLE DEPTH UNCHES) LENGTH OF IN NAVAL (MIN) WATER DEPTH AT START OF INTERVAL ONE HES) WATER DEPTH AT IND OF INTERVAL (INCHES/ DROP IN WATER LEVEL (INCHES! ..z. AVERAGE Pcr.COLATION RATE (MN nNCH) P•1 47 15 10 A 8 X 114 30 8X E X 6 7X % 7% 614 Y. 514 6 % X 8% 5X % 5% 5 X 5 4 )4 4 P•2 55 15 avatar added 8)4 776 2 ' 24 7X 6% 1)4 614 5% 14 5X 4X 1X 4% 3X % 7 8% 1% 514 5 % 5 4A % P•3 45 15 water addW 8 % 7 % 1 X -ore 7 X 7 !t 7 6 1 6 5% X 5X 4% 1 7X 7 X 7 6X % Note; Percolation test holes were dug in the bottom of backhoe pits and soaked by the client prior to cur field work. Percolation testa were conducted on April 2, 2001. The average percolation rates were based on the fast two readings of each teat. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Jun 30 03 07:36p Ray Gotfredson 870-863-d401 JUN -27-03 FRI 07:35 AN GHCO CORP. FAX N. 9708259101 48 PROrtE PIT BLUEBELL LANE 37 100 b 49' A 96' 247 P-1 219' z 4 x a P-2 P-3 APPROXIMATE SCALE 1.50 286' 101 255 HEPWORTH—PAWLAK GEOTECHNICAL, INC. LOCATION OF PERCOLATION TEST HOLES Fig. 1 a