HomeMy WebLinkAboutApplication- PermitGARFIELD COUNT* BUILDING AND SANITATION DEPARTMENT
109 8th Street Suite 303
Glenwood Springs, Colorado 81601
Phone (303) 945-8212
A �
4
INDIVIDUAL SEWAGE DISPOSALPERMIT
PROPERTY
Owner's Name 1 -- kit a Present Address
System Location 0.41 1Jtsu._. Br.
0291-93-Os—
Permit NE 3875
Assessor's Parcel No.
This does not constitute
a building or use permit.
Legal Description of Assessor's Parcel No
SYSTEM DESIGN
4 E" Septic Tank Capacity (gallon) Other
A `/1
"Percolation Rate (minutes/inch) Number of Bedrooms /(or other) ' ! / /
13' 2 !t / P.,cL Frrc
Restfired Absorption Area - See Attached (y -7S- lb 1 nn,AG L (,."-- Lew s
Special Setback Requirements: SS t I ✓ ( e t eJn 0,1-4-n b e g
hone TC)0
3 lP pe s roe
4/3 /00; rr etArn 3X�
SO(Jc S vs( xb'
3 _ 3 %��.�
? Date ��- Inspector Ler
i FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
r
System Installer
Septic Tank Capacity / 2 S
Septic Tank Manufacturer or Trade Name t t9o-►—
Septic Tank Access within 8" of surface 1
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name /4ft-C,:;:,
Adequate compliance with County and State regulations/requirements .t1
Other
00
Date
Inspector
RETAIN WITH RECEIPT ION SITE
RECORDS AT CON TRUCT
CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine —6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
sNt cY POThaal .Niv`3A0CP
OWNER 5 RCS/VG `5l "LCG
IDogK Pito PertrrCS
oo F. M nry sr, sit: 103
ADDRESS spsv, co Slit)
Aimee
CONTRACTOR MAtn avr
aTN(f coRA.
ADDRESS �.s nLT. ox (lo
vg Viet t 1
PHONE 970 - TZO - 2 300
PHONE ?70 - 727- 102.4
PERMIT REQUEST FOR (x) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town CA le C0/094F Size of Lot 3.a 7i. /9c/ 3
Legal Description or Address 1.07 C , s r.=Rcr vG R/9NC'-1 PVD ! Q 110 q SKiep
WASTES TYPE: (x) DWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER - DESCRIBE
BUILDING OR SERVICE TYPE:
Number of Bedrooms q Number of Persons
('4 Garbage Grinder
( x) Automatic Washer (K) Dishwasher
SOURCE AND TYPE OF WATER SUPPLY: (x) WELL ( ) SPRING ( ) STREAM OR CREEK
Gi cehmgAr7y wEu. Swin-t
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
A site plan is required to be submitted that indicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System (septic tank & disposal field) to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
2
(X) SEPTIC TANK
( ) VAULT PRIVY
( ) PIT PRIVY
( ) AERATION PLANT ( ) VAULT
( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
( ) CHEMICAL TOILET( ) OTHER -DESCRIBE
FINAL DISPOSAL BY:
(\04. ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
( ) UNDERGROUND DISPERSAL ( ) SAND FILTER
( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
( ) OTHER -DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE
STATE? PERCOLATION TEST RESULTS: (To be completed by
Registered Professional Engineer, if the Engineer does the Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole NO. 3
Minutes per inch in hole No. 2 Minutes per inch in hole NO.
Name, address and telephone of RPE who made soil absorption tests:
Name, address and telephone of RPE responsible for design of the system:
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed
firg=
Date
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
SPACE
2310 LF r PVC
LOCATION
VELL IDC TO
mora =mix TO VA
TOTAL 6 205 Lt OS
awn HONE
7000 OIL TNS
LF C
DAIS 200 PVC
PURE -COM
CZ TO WM
vno
<s r PUE-CORE
ego u -
STIRLING RANCH P.U.D
GARFIELD COUNTY, COLORADO
LRAWDIO
��00 �I{IIIIIIIIIII►ISI►►►ui����i►I111111111111111111111111111111Iuu��►►i►ill�
TIMBERLINE ENGINEERING
OP
Hepworth-Pawlak Geotechnical, Inc.
GeSt" ech 5020 County Road 154
Glenwood Springs, Colorado 81601
Phone: 970-945-7988
HEPWORTH-PAWLAK GEOTECHNICAL Fax: 970-945-8454
email: hpgeo@hpgeotech.com
September 24, 2003
Sally Allen-Potvin
c/o Peak Properties of Aspen
600 East Main Street, Suite 103
Aspen, Colorado 81611
Job No. 103 554
Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed
Residence, Lot 6, Stirling Ranch, Skipper Drive, Garfield County,
Colorado.
Dear Ms. Potvin:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and
percolation test for foundation and septic disposal designs at the subject site. The study
was conducted in accordance with our agreement for geotechnical engineering services
to you dated September 4, 2003. The data obtained and our recommendations based on
the proposed construction and subsurface conditions encountered are presented in this
report.
Proposed Construction: The proposed residence will be a one and two story wood
frame structure with an attached garage located on the site as shown on Figure 1.
Ground floors will be structural over a crawlspace for the residence and slab -on -grade
in the garage. Cut depths are expected to range between about 3 to 5 feet. Foundation
loadings for this type of construction are assumed to be relatively Light and typical of
the proposed type of construction. The septic disposal system is proposed to be located
to the west of the proposed residence.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: A rough graded driveway and a water line had been constructed into
the building site. The building site was vacant at the time of our field exploration. The
ground surface in the building area slopes gently to moderately down to the southwest at
grades up to about 6%. A steeper hillside sloping down to the southwest is located
about 50 feet to the southwest of the proposed building area. The lot is vegetated with
pinon and juniper trees with an understory of cactus, grass and weeds. Numerous
basalt cobbles and boulders are exposed on the ground surface.
PorLor 3/li.R4.1-7110 • Onlnro,tnCnrinnc 710 -All -SSA? • Rila,Arthnrno 070.4.AR-1ORO
Sally Allen-Potvin
September 24, 2003
Page 2
Subsidence Potential: Stirling Ranch is underlain by Pennsylvania age Eagle Valley
Evaporite bedrock. The evaporite contains gypsum deposits. Dissolution of the
gypsum under certain conditions can cause sinkholes to develop and can produce areas
of localized subsidence. Sinkholes were not observed in the immediate area of the
subject lot. The exploratory pits were relatively shallow, for foundation design only.
Based on our present knowledge of the site, it cannot be said for certain that sinkholes
will not develop. In our opinion, the risk of ground subsidence at Lot 6 is low but the
owner should be aware of the potential for sinkhole development.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits in the building area and one profile pit in the septic
disposal area at the approximate locations shown on Figure 1. The logs of the pits are
presented on Figure 2. The subsoils encountered, below about 1 foot of topsoil, consist
of basalt gravel, cobbles and boulders in a calcareous sandy silt matrix. Results of
swell -consolidation testing performed on a relatively undisturbed sample of silt matrix,
presented on Figure 3, indicate low compressibility under existing moisture conditions
and light loading and a high collapse potential (settlement under constant load) when
wetted. The sample showed high compressibility upon increased loading after wetting.
There could have been some disturbance of the sample due to the hard dry condition of
the soil. Results of a gradation analysis performed on a sample of the gravel and cobble
soils (minus 5 inch fraction) obtained from the site are presented on Figure 4. No free
water was observed in the pits at the time of excavation and the soils were slightly
moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 2,000 psf for support of the proposed residence. Footings should be a
minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and
disturbed soils encountered at the foundation bearing level within the excavation should
be removed and the footing bearing level extended down to the undisturbed natural
soils. Voids created by the removal of large rocks should be backfilled with compacted
sand and gravel, such as 314 -inch road base, or with concrete. Exterior footings should
be provided with adequate cover above their bearing elevations for frost protection.
Placement of footings at least 36 inches below the exterior grade is typically used in this
area. Continuous foundation walls should be reinforced top and bottom to span local
anomalies such as by assuming an unsupported length of at least 12 feet. Foundation
walls acting as retaining structures should be designed to resist a lateral earth pressure
Job 8103 554
HP.
Sally Allen-Potvin
September 24, 2003
Page 3
based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil, excluding
vegetation, topsoil or oversized rock, as backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support
lightly loaded slab -on -grade construction. To reduce the effects of some differential
movement, floor slabs should be separated from all bearing walls and columns with
expansion joints which allow unrestrained vertical movement. Floor slab control joints
should be used to reduce damage due to shrinkage cracking. The requirements for joint
spacing and slab reinforcement should be established by the designer based on
experience and the intended slab use. A minimum 4 inch layer of sand and gravel, such
as /-inch road base, should be placed beneath slabs -on -grade for a leveling course.
This material should consist of minus 2 inch aggregate with less than 50 % passing the
No. 4 sieve and less than 12% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95 % of
maximum standard Proctor density at a moisture content near optimum. Required fill
can consist of the on-site soils devoid of vegetation, topsoil and oversized rock.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95 % of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 12 inches in the first 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement
and walkway areas.
4) Roof downspouts and drains should discharge well beyond the limits of
all backfill.
5) Irrigation sprinkler heads and landscaping which requires regular heavy
irrigation, such as sod, should be located at least 5 feet from foundation
walls.
Job #103 554
SAO
Sally Allen-Potvin
September 24, 2003
Page 4
Percolation Testing: Percolation tests were conducted on September 17, 2003 to
evaluate the feasibility of an infiltration septic disposal system at the site. One profile
pit and three percolation holes were dug at the locations shown on Figure 1. The test
holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of
shallow backhoe pits and were soaked with water one day prior to testing. The soils
exposed in the percolation holes are similar to those exposed in the Profile Pit shown on
Figure 2 and consist of about 1 foot of topsoil overlying basalt gravel, cobbles and
boulders in a calcareous sandy silt matrix to the backhoe refusal on boulders at a depth
of 4 feet. The percolation test results are presented in Table 1. The percolation test
results indicate an infiltration rate between 7 and 20 minutes per inch with an average of
16 minutes per inch. Based on the subsurface conditions encountered and the
percolation test results, the tested area should be suitable for a conventional infiltration
septic disposal system. The depth of suitable soils below the septic disposal area should
be verified by additional excavation before or at the time of construction.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either express or implied. The conclusions and recommendations submitted in
this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Figure 1, the proposed type of construction and our experience in
the area. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
Job #103 554
HP
Sally Allen-Potvin
September 24, 2003
Page 5
If you have any questions or if we may be of further assistance, please let us know
Sincerely,
HEPWORTH - PAWLAK GEOTEt' - ; - _ _INC.
Jordy Z. Adamson, Jr.,
Reviewed by:
Steven L. Pawlak, P.E.
JZA/djb
attachments
Figure 1 - Location of Exploratory Pits and Percolation Test Holes
Figure 2 - Logs of Exploratory Pits
Figure 3 - Swell Consolidation Test Results
Figure 4 - Gradation Test Results
Table 1 - Percolation Test Results
cc: Ernest Kollar Engineers, Inc. - Attn: Ernie Kollar
John Muir Architects, Inc. - Attn: Kristin Mule'
Maley Building Corporation - Attn: Patrick Maley
Job #103 554
_ NP. .
APPROXIMATE SCALE
1' = 50'
LOT 9
7162
I
EXISTING
DRIVEWAY
TO SKIPPER
DRIVE /
1t/
6�
/ Z,L /
,' // 7 11
// I
I
7 7/ // 1/ 11 1 111
/ PROFILE /y 1/ I I I I/ 1
/// P 1A 1/ //PIT 1 ; i r 7162 ' . ` \i P 2Q� tee
I vt /
/ PROPOSED Iii/
P 3 RESIDENCE —
77160
,/ PIT 2 \-----
, \ _ --/
_�
�� \
i / \
7158 ,/ \
LOT 6
7156 // �— \ \\
\ I /7154 ) \)
// de /-
7156
7152
/
7158
103 554
HEPWORTH—PAWLAK
GEOTECHNICAL, INC.
LOCATION OF EXPLORATORY PITS
AND PERCOLATION TEST HOLES
Figure 1
4S
Li-
fl.
i
5
a
a
.. 0
5
_ 10
LEGEND:
n-/
I
_J
T
NOTES:
PIT 1
ELEV.= 7161'
PIT 2
ELEV.= 7158'
PROFILE PIT
ELEV.= 7161'
TOPSOIL; sandy clayey silt, organic, firm, moist, dark brown.
0
5
10
BASALT GRAVEL AND COBBLES (GM); In a sandy silt matrix, with boulders, dense, slightly moist,
light brown to white, calcareous.
2" Diameter hond driven liner sample.
Disturbed bulk sample.
Practical digging refusal with backhoe.
1. Exploratory pits were excavated on September 16, 2003 with a Cat 420D backhoe.
2. Locations of exploratory pits were measured approximately by pacing from features shown on the site
plan provided.
3. Elevations of exploratory pits were obtained by interpolation between contours on the site plan
provided. Logs are drawn to depth.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied
by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries
between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may
occur with time.
7. Laboratory Testing Results:
WC = Water Content ( X )
DD = Dry Density ( pcf )
+4 = Percent retained on No. 4 sieve
—200 = Percent passing No. 200 sieve
Depth — Feet
103 554
HEPWORTH—PAWLAK
GEOTECHNICAL, INC.
LOGS OF EXPLORATORY PITS
Figure 2
Compression X
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Moisture Content a 12.7 percent
Dry Density - 67 pcf
Sample of: Sandy Silt Matrix
From: Pit 2 at 3.5 Feet
Compression
upon
wetting
0.1
.0 0
APPUED PRESSURE — ksf
100
103 554
HEPWORTH—PAWLAK
GEOTECHNICAL, INC.
SWELL CONSOLIDATION TEST RESULTS
Figure 3
- RC NT R Al P
R70W1llal 0.04.290 SPE711E REAM= us sTNCN SERIES SPE
CLEM SWARF WENNs
24 RR. 7 IRI
0 b HL 15111L pp net • IK 1 a 6100 ro /30 610 a
10
20
30
40
30
00
70
10
00
100
M 3//' 3/C 1 1/r r yr r 100
WSW
�WOW
-.
WS
----WS —i•
WW
--��--
CX-
-C
•
- --IS!' MI
r
-- -
— --ISa-
-�
�- --
S--
.W __ -IS .S
•
—S SMIS�
- SO
WE SF
.� ala
.� WO'a
.�S
W AS SI
SSW
SW.
SO
SMI
SOMMER
MSS
v
- -
.001 .002 .000 000 .010 .037 .074 .100
.300 .000 1.13 2.30 435 0.61 12.0
DIAMETER OF PARTICLES IN MIWMETERS
37.0 76.2 12152 703
CLAY 70 aT
GRAVEL 60 X
ISL
RE 1 ,E®R, [COARSE 1 r01E I COARSE
SAND 18 % SILT AND CLAY 22 X
LIQUID LIMIT X PLASTICITY INDEX X
SAMPLE OF: Basalt Gravel and Cobbles in FROM: Pit 2 at 4 thru 5 Feet
a Sandy Silt Matrix
COORS
90
0
70
00
S0
40
30
20
I0
0
. ]:itJS 1RTh
103 554
HEP WORTH—PA WLAK
GEOTECHNICAL, INC.
GRADATION TEST RESULTS
Figure 4
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1
PERCOLATION TEST RESULTS
JOB NO. 103 554
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
P-1
39
15
water added
water added
5
4
1
20
4
31/4
3/4
5 1/4
4 1/2
3/4
4 1/2
3 314
3/4
5
4 1/4
314
4 1/4
3 1/2
3/4
P-2
35
15
water added
water added
water added
water added
6
3 1/2
2 1/2
7
5 1/4
3
2 1/4
5 3/4
3 1/2
2 1/4
5 3/4
3 1/4
2 1/2
5 3/4
3 1/2
2 1/4
3 1/2
1 1/4
2 1/4
P-3
41
15
water added
water added
water added
5
3 1/2
1 1/2
20
5 314
4 1/2
1 1/4 1
4 112
3 3/4
3/4
5 1/2
4 314
3/4
5 3/4
5
3/4
5
41/4
3/4
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
September 16, 2003. Percolation tests were conducted on September 17, 2003. The
average percolation rates were based on the last two readings of each test.