HomeMy WebLinkAboutApplication- PermitI3
�I}
\-1.,se\
Jti-.Id
cJ \�J\ ARFIELD COUNTY?BUILDING AND SANITATION DEPARTMENT Permit N`_ 3561
`����//// v 109 8th Street Suite 303 Assessor's Parcel No.
l Glenwood Springs, Colorado 81601
OS-
I INDIVIDUAL SEWAGE DISPOSAL PERMIT
t PROPERTY
Phone (303) 945-8212
This does not constitute
a building or use permit.
1I n o
y, Owner's Name;114tl L C?rS L`� //�Prresent Address 1 LI 7 LDFt�L,P%l�UF 171 /SP Phone 32 yJ 2_Si(
61° E-
A System Location 0 13THf R Ct (In o ) Si C
f` `) 019
Legal Description of Assessor's Parcel No
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch)
Required Absorption Area - See Attached
Special Setback Requirements:
Date
Number of Bedrooms (or other)
Inspector
„ FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
Septic Tank Capacity
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements
Other 1/�' s K/1
Date Inspector Il �7�— \may,
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTI N SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs. alters, or Installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained In the application of permit commits a Class I, Petty Offense ($500.00 f ine — 6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
•
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER tAV e \e. Ptuac De vt.kof 'nloi 1st t`^-ir,
ADDRESS . �o-, ' 7 2'1 �ler,a�oo d (6-S 516 oz. PHONE 3�4 Z S`t`d
CONTRACTOR IC1 o`^^ kaA.s /a •..d Wo,l'As < •
ADDRESS Po f,ot Ivo 31.<0vJoo`f c PHONE "2.16'4- - 22ut
PERMIT REQUEST FOR V NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town S; k Size of Lot q a, 7 Z€
Legal Description or Address Cot 3 U Ica'lt A (-CI t r �� OA :N << 0-r. . Gas' kris 1.01 C4 y co
WASTES TYPE: (X) DWELLING £s / C t- S f I TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER - DESCRIBE
BUILDING OR SERVICE TYPE: Praha -4: th/u Q.
Number of Bedrooms Number of' Persons Y
( ) Garbage Grinder ()) Automatic Washer ()a Dishwasher
SOURCE AND TYPE OF WATER SUPPLY: (Q WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier: {AU 1t #crcc (tvr+n,Ny v\ 1 Wcxf cr
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System? NC)
A site plan h reauired to be submitted thatindicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System to Property Lines: 10 feet
YOUR INDIVWDUALIEWAGE DISPOSAIJYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN,
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
2
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
SEPTIC TANK
VAULT PRIVY
PIT PRIVY
CHEMICAL TOILET
( ) AERATION PLANT ( ) VAULT
( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
( ) OTHER - DESCRIBE
FINAL DISPOSAL BY:
(X) ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
( ) UNDERGROUND DISPERSAL ( ) SAND FILTER
( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
OTHER - DESCRIBE
( )
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE?
t Jo
PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the
Percolation Test)
Minutes per inch in hole No. 1
Minutes per inch in hole No. 2
Name, address and telephone of RPE who made soil absorption tests:
Minutes per inch in hole NO. 3
Minutes per inch in hole NO.
�� •� (e6(C cl' — 199?
Name, address and telephone of RPE responsible for design of the system: DQRe K of f y (L ' 'f C'4/news
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,.
intonation and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed �i^"- hat
L
Date
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
1a unurr
EASEMENT,
209.02'
N 8979
L�St%L
S 8979
Ns9s4:ut
12404'
LOT 2
96,414 sq. tt
2.21 oars
_ Ne9r4:uT
13400'
S850774 NE
way 6 et ,24 (cp.0. 4)
October 31, 2001
Garfield County Building & Planning
109 Eighth Street, Third Floor
Glenwood Springs, CO 81601
U /� ' / Ar- i
J
a] J 1
07
1 -
Re: ISDS for Lots 1,2,3,7 and 9 — Ukele Acres Subdivision
LICE Job No. 2011081.59
To Whom It May Concem:
RECEIVED NOV 0 7 2001
On October 8, 2001, High Country Engineering personnel observed the construction of the ISDS
Lots 1,2,3,7 and 9 of the Ukele Acres Subdivision in Garfield County, Colorado. The observations
made were:
Lot 1
The tank had been buried, but it appeared that one 1000 -gallon septic tank had been installed
with 24 standard Infiltrator units in a trench configuration. No additional backfilling had
taken place. The owner was advised to rake the trench sidewalls, install the effluent filter and
install the inspection wells. Other than that, the installation of the system was in
conformance with the intent of the design.
Lot 2
One 1000 -gallon septic tank and 34 standard Infiltrator units had been installed in a trench
configuration. No backfilling had taken place. The owner was advised to rake the trench
sidewalls, install the effluent filter and install the inspection wells. Other than that, the
installation of the system was in conformance with the intent of the design.
Lot 3
1000 -gallon septic tank and 112 standard Infiltrator units had beer, installed in a bed
configuration. No backfilling had taken place. The owner was advised to rake the bed
sidewalls, extend the outlet tee into the center of the septic tank riser, install the effluent filter
and install the inspection wells. Other than that, the installation of the system was in
conformance with the intent of the design.
Lot 7
One 1000 -gallon septic tank and 32 standard Infiltrator units had been installed in a trench
configuration. No backfilling had taken place. The owner was advised to rake the trench
sidewalls, install the inlet tee in a vertical position, install the effluent filter and install the
inspection wells. Other than that, the installation of the system was in conformance with the
intent of the design.
1517 Blake Avenue, Ste. 101
Glenwood Springs, CO 81601
Telephone (970) 945-8676 - Fax (970) 945-2555
14 Inverness Drive East Suite 13.144
Englewood, CO 80112
Telephone (303) 925-0544 - Fax (303) 925-0547
r
Glarfield County Building & Planning
October 31, 2001
" Page 2
Lot 9
One 1000 -gallon septic tank and 26 standard Infiltrator units had been installed in a trench
configuration. No backfilling had taken place. The owner was advised to rake the trench
sidewalls, install the effluent filter and install the inspection wells. Other than that, the
installation of the system was in conformance with the intent of the design.
A follow up inspection was conducted on October 30, 2001. At the time of re -inspection, all
inspection wells had been installed and septic tanks had been covered.
If you have any questions, or need additional information, please contact us.
Sincerely,
HIGH COUNTRY ENGINEERING, INC.
Roger 1. Neal, P.E.
Project Manager
2f5
RDN/djw p�
Cc: Pete Waller . IONP.t.Cr?;;;.).
1517 Blake Avenue, Ste. 101
Glenwood Springs, CO 81601
Telephone (970) 9454676 - Fax (970) 945-2555
14 Inverness Drive East Suite 13-144
Englewood, CO 80112
Telephone (303) 925-0544 - Fax (303) 925-0547