HomeMy WebLinkAboutApplication- PermitJob Address No. 6225 GAR!*IELD COUNTY BUILDING, .SANITATION and PLANMNG DEPARTMENT 109 8111 Street Suite 303 Glenwood Springs, Colorado 81601 (303) 945-8212 37 Roan Creek Place, Battlement Creek Village, Lot 25, Block 2, Battlement Mesa Nature of Work Use of Building_ Owner Building Permit Single Family Dwelling w/Double Garage Judy Topol & Randy Jenkins Contractor Fox Construction Amount ofPermitS 3,080.96 Permit: 1,867.25 Plan : 1,213.71 Paid $1,220.21 2-24-97 pate March 13, 1997 S. Archuleta Clexk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only, PERMIT NO. TARCEL/SCHED NO. JOB ADDRESS 3 ? es -a„....) LC.e-, 1 g . 1 ., u W !7 �,/ i ' 1 1 LEGAL DESCR, LOT NO. 2s' BLOCK r7 L� / l S/UBDIVISION /� _ j�leie _ L / % _ _e4 / I+// e, c mes 1 (J��I�/7/ !Tf deee4 ./O,✓c7 2 JJ OWNER.Xy�y I" f D4 „�y 44 fff ,` ADDRESS 37 Acr„ l .tel met PH'S„,/ WK. PH. 3 CONTRACTOR < 157L- ADDRESS A. /3Z// d oth PH. az54...845#LICENSE NO. 4 ARCHITECT OR DESIGNER ADDRESS PH. LICENSE NO. 5 ENGINEER ,,,'Gn` / U,n ADDRESS ZS/ 6 gmak, a, PH. xys 5.5- LICENSE NO. 3F OF�IJILO NSG J5) L i� Q C;r'Qq� S.F OF LOT SZ, / P 7 HEIGHT 22' NO. OF FLOORS 7 siy�ep� ?q/n/4,, j �Laerree) LSE OF BUILDING C t.l ,JJ gin-5-'''k- � 8 8 CLASS OF WORK: YNNEW ❑ ADDITON ❑ ALTERATION ❑ REPAIR ❑MOVE ❑ REMOVE // 9 DESCRIBE WORK: ! Is. i. rn� O f tititi... III ///rrr+++ � �'`�� `� t /� �y,,�- • Z r./ _9l i pin 4 Sl ei^�' ` , ' 10 GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE , Q -r--- DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN/ ),! 3 , 7 ./ 1 1 VntuAron cF worm: ADJUSTED VA .S �� j� 'y ,3/ PERMIT E S 7, a' 3 PLAN CHECK FEE / SPECIAL CONDITIONS: Y 3 / [/ Q X Zs. 9`41711(4-1-124SCHOOL 87S -c; 4 -C /7. a S— / i197, 0 IMPACT FEEM //Iljj'' NO. OF BUILDINGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL 0 TOTAL FEEI,3/6 IS" Q, ?4 OCC. G .,3, cas_ CONST. TYPE.1- N NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL. PLUMBING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED NOT COMMENCED WITHIN 160 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 160 DAYS AT ANY TIME AFTER COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND THE SAME TO BE TRUE ANO CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NCT, THE GRANTING OF A PERMIT DOES NOT PRESUME AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE LOCAL LAW RETING C TR CTION CR PERFORMANCE CONSTRUCTION Da WATER SUPPLY DATE PERMIT ISSUED 3 ^/3 - 9 7 HEATING, SPECIAL APPROVALS REQUIRED RECEIVED NOT REQUIRED IS ZONING i/ �------- WORK LS HEALTH DEPT. KNOW FIRE DEPT. TO GIVE SOIL REPORT OR OF SETBACKS .-------- FLOOD HAZARD Signature of er Cantracrar I� ��•- Building DeparrnentAppr• I +. J; or authorized agent h.. g •_.. _ nd`un;.. n MA.NUF, HOME . d- - Planning Department c:, oval 8- e OTHER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.26.201 CRS AS AMENDED, THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION QF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES, THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE j1NITIAL The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a'sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4,. A complete bathroom, with wash bowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1994 UBC requirements;' 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made, A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****Cannot occupy or use dwelling until a Certificate of Occupancy (C.O.) is issued. Occupancy or use of dwelling without a C.O. will be considered an illegal occupancy and may be grounds for vacating premises until above conditions are met. - I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # Signature 4314 D ate z - z y--97 _65.23 Er, ,?94,/l A4,0 tir,r si,29 4451, 17, , 2 .__ .�"l3 21/1 4'4 7. aS' GARFIELD COU TY BUILDING AND PLANJv 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS ING in order to understand the scope of the work intended under a pellriit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discoverY that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor ma�v be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be f7i.ven attention before the new information may be reviewed after it has been provided to the Building Depaitiinent. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are require to indicate appropriately and to submit the completed check list at time of application for a permit. For the placement of a manufactured home, questions numbers 1-4 and 19-28 are the only questions that need to be addressed: 1 Is a site plan included that indicates the distances of the proposed building, or addition to property lines. other bThdings, set back easements and utility easements? Yes Does the site plan include the location of the I.S D.S (Individual Sewage Disposal System) and the distances to property lines. wells (on subject property and adjacent properties), streams or water courses Yes 3. Does the site plan indicate the location and direction of the County or private road accessintg the property? Yes !� Do the plans include a foundation plan indicating the size. location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes 5 Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearance,required between wood and earth' Yes 6 Do the plans indicate the size and location of ventilation openings for the attic. roof joist spaces and soffits Yes Do the plans include design loads as required under the Uniform Building Code for roof snow loads. (a' �ninit m of 40 pounds per square foot in Garfield County}. floor loads and wind loads" Yes Does the plan include a building section drawing indicating foundation. wall. floor and roof construction' Yes Does the building. section drawing include size and spacing- of floor joists. wall studs, ceiling joists, roof rafters or or trusses? Yes 10 Does the building section drawing or other detail include the method of positive connection of all columns and 'ams? Yes Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours'',. Yes 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model a olorado Phase II certifications or phase IT EPA certification? Yes No 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No 14. Does the plan include a window schedule or other verification that egressirescue windows from sleeping roo and/or basements comply with the requirements of the Uniform Building Code? Yes No V 1 Does the plan include a window schedule or other verification that windows protide natural light and ventilatio for ail habitable rooms`' Yes No 16 Do the plans indicate the location of glazing subject to human impact such as glass doors_ glazing immediately adjacent to such doors. glazing adjacent to any surface normally used as a walking surface; sliding glass doors: fixed glass panels: shower doors and tub enclosures and specify safety glazing for these areas? Yes No 17 Is the location of all natural and liquid petroleum gas furnaces. boilers and water hearers indicated on the plan' Yes No I S. Do you understand that if you belong to a homeowners association. it is your responsibility to obtain written permission fro the association_ if required by that association, prior to submitting an applicati or a building permit? Yes No 19. Will this be only residential structure on the parcel? Yes j/ No If no -Explain 20 Have two (2 complete sets of construction drawings been submitted with the application? Yes 3 21. is this an application for the plac.ert t of a manufactured home') Yes No If yes, have you specified the size of the unit (min. 2Oft. x 20ft), live roof load (min. 40 )_ wind design (min. wind speed of 80 mph & 15 ]b. wind load), foundation design, method of anchoring? Yes 22. 13. Have you designed or had this pian designed while considering building and other construction code requirements? Yes No Does the plan accurately indicate what vou intend to construct and what wi]] receive a final inspection by Garfield County Building Department? Yes No 24. Do vou understand that approval for desist andlor construction changes are required prior to the application o se changes? Yes No 25. Do you understand that the Building Department will collect a "Plan Review fee from vou at the time of application and that vou will be required to pay the "Permit Fee" as well as any "School Impact" or S vstern" fees required, at the time vou pick up your building per;nit' Yes No 26. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before: afternoon inspections must be called in by .5:00 p.m. the day before. Failure to give twenty four (24) hour notice for inspections will delay your inspection one (1) day? Yes 1 No 27 Are vou aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy . building? Yes No 28 Are you aware that the person signing the Permit Application, whether the "Owner". "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project co mg with the Uniform Building Code`' Yes No 4 I hereby acknowledge that I have read, understand arid answered these questions to the best of my ability. signature date Phone: V-2..657-4361? (days); 2--Z1/-77 970-24' 3777 (eveninu,$) Project Name: 7;;9617`— Je,Z 4,rzs Jet5v ej7nCe.. Project Address: .37 Awl de deeotAcc_ E4#4,ne,i7z ifiesyl Notes: If you nave anssvered "No" on anv of the questions, you may be required to provide this information at the rogues] of the l3uddrno Official prior to beginning the plan review process Delays iii issuing We peanut are to he expected «Vorl mai not uroeec;i without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to r:\ ie`\ the application and plans to determine minimum compliance with the adopted cocks: the application rua:. he placed behind more recent applications for building- permits in the review process and nor reviewed until reciutred inforntatton has been provided and the application rotates again to fust position for review. dela\ w Issuanec of the permit or delay m proceeding with construction PerApp02.93 Effective Aun-ust 1 1995 INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT ARFIELD``COUNTY, COLORADO Date Issue 343 .mooned Area Permit No AIRP CS AGREEMENT In consideration of the issuance of this permit; the applicant hereby agrees to comply with all . laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described st acture, the permit may then be revoked by notice from the County Building .Inspects°,Lptl 1 IATELECOM,E NUL ND,VO,1 Use Address ti -a Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD ' Footing3 XV/, L:9vr,�F; arr ` p�-� ' . 7 \ 3�"�zrr<lLr��'�Cl��;.,/����r3-=�'GL� � Day ---7— ��ccLz� Foundation0g.'p 44 ,uw. 7 iit,* ?,;'U X;-14.4• & UndergroundPlembing;; °q747:,A; .:Insulation ',., _ 11 /.,�' Rough FIuxnbtng'V.s+=� °r ' ;, ;t '" ` ' Drywall'4 L/'.-7 'F6�/ Chimney & Vent Electric Final (by' State inspector)R /7 , Gas Piping Final 9__, —9/ 6/ A Electric Rough (By Slate Inspector) °1 `17a- Septic Final ti'' Framing e.,"- `4-q7P..r? 3-y. =r„ (To include Roof in place and Windows and Doors installed).0. ray'' Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT; TRANS.FERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. APP F OVEDDO NOT DESTROY THIS CARD 1 t Date By 101 f F PLACED OUTSIDE - COVER WITH CLEAR PLASTIC