Loading...
HomeMy WebLinkAboutConstruction Materials Testing 02.09.17Huddleston-Berry f-lirgineerirt g & -l cstiLr¡¡, l"l,(l 640 White Avenue Gra¡rd Junction, CO 81501 Phone: 970.255.80ti5 Iax:97{i.255.6818 i n 1i{}H uc{dles tou lleny, com www,Flï.ÌHT'-C.i.ccm February 9,2Q17 Project No.: 01303-0007 Clayton Homes 2394Hwy6&50 Grand Junction, CO 81505 Reference:Geolechnical Investigation, l85l Counry Road 306, Parachute, CO, by Huddleston-ßerry Engineering and Testing, LLC, teport # 013{}3-0007' dated I2/20/2û16. Subject:Construction Materials Testing and Special Inspections 1851 County Road 306, Parachute, CO. Dear Sir, A representative of Huddleston-Berr), Engineering and Testing, LLC (HBET) performed testing for the subject project on February 6, 7, and 9, 2016. Periodic testing for the subject project is complete and any exceptions have been conected. The open hole inspection indicated that the subsurface soil conditions on the lot are consistent with the referenced report. Thırefore, based upon the recommendations in the referenced report, results of the open hole inspection, and results ofthe field density testing, the subgrade is adequate for foundations constructed in accordance with the County Minimum Hause Foundation Stcndørds using an allowable bearing capacity of 250Û psf. HBET appreciates the opportunity to offer services to your project. If you have any questions please call. (e70) 2ss-80û5. ly Submitted: and TestingrLLC Administrator