Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-03-17-4629 Friedman — New SF Residence & Garage Aspen Glen — Filing 2, Lot GV5 Carbondale, Colorado 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) OPEN -HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION TO VERIFY 2500 PSF. 4) PROVIDE A LOT IMPROVEMENT SURVEY AT FRAMING INSPECTION FOR VERIFICATION OF THE FOLLOWING ITEMS: A) ALL STRUCTURES ARE FULLY CONTAINED WITHIN THE PLATTED BUILDING ENVELOPE INCLUDING ROOF OVERHANGS, DECKS & PROJECTIONS. B) PROVIDE BUILDING HEIGHT ELEVATION SURVEY TO VERIFY COMPLIANCE WITH MAXIMUM BUILDING HEIGHT OF 25 FEET. 5) INSTALLATION OF A RESIDENTIAL FIRE -SPRINKLER SYSTEM IS REQUIRED AND SHALL BE IN ACCORDANCE TO NFPA 13D OR I.R.C., SECTION P2904. VERIFY ALL REQUIREMENTS AND COORDINATE INSPECTIONS WITH LOCAL FIRE DISTRICT. PROVIDE EVIDENCE OF ROUGH -IN APPROVAL AT FRAMIING INSPECTION, AND FIRE DISTRICT SIGN -OFF AND APPROVAL REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 6) VERIFY REQUIREMENTS AND COORDINATE INSPECTIONS OF VERTICAL LIFT WITH NORTHWEST COLORADO COUNCIL OF GOVERNMENTS' (NWCCOG) ELEVATOR INSPECTION PROGRAM. PROVIDE FINAL SIGN-OFF/APPROVAL AT FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.