HomeMy WebLinkAboutApplication- PermitJob Address No.6113 GARFIELD COUNTY BUILDING, SANITATION ark PL.ANNINGDEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 (303)945-8212 40 Promontory Place, Willow Creek, Lot 12, Block 8, Battlement Mesa NatureofWork Building Permit Use of Building Single Family Dwelling w/Double Garage O WMT Richard Shively Owner Contractor Amount of I% wit S 1,752.71 Permit: 1,062.25 Plan . 690.46 Paid $674.21 9-26-96 Date October 21, 1996 S. Archuleta Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only, PERMIT NO. [/r// 3 PARCELISCHED NO. jj�J I,,[-- JOB di ADDRESS T 0 PHI M'1 c., -,1,,,,,i O�C A., -,,L, -q.. QQ / ip 3_.w' _ 1 LEGAL DESCR, LOT NO. / BLOCK d. 0 SUBDIVISION !!! I I 1 f ,C� ! 1fOc e{ -PA lc' ,r 1 f [ aat a cl2.t.i I a v, l` 1r13L 2 ll40-s- OWNER ICVvr.r.Q c-SlSjlr-�y A kb -4.. v .614_ 0 ADDRESS IISa�.!<. .. Co PH. 9q.OLCb WK. PH. 3 CONTRACTOR �7CL+a r.c� t�!. ADDRESS aa... PH. cjcQy . LICENSE NO. 4 JS ARCHITECT OR DESIGNER ADDRESS PH. LICENSE NO. 5 ENGINEER ADDRESS PH. LICENSE NO. 6 S.F OF BUILDING ar, 5'-l(a (,)tip S.FOFLOT lt,�o�C) HEIGHT N/ NO. OF FLOORS / 7 USE OF BUILDING'. PS tou - 4,t6 j 8 C4 -ASS OF WORK; XNEW ❑o ADDITIION c ALTERATION D REPAIR ❑ MOVE` D REMOVE 9 j DESCRIBE WORK C\OY1�a 1_N'U4C %q4,r/ }"-�S IO.An+.1 c41 `lA�J L. 10 GARAGE SINGLE DOUBLE A r CARPORT SINGLE DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN A 5'',0.4(A, ss 11 VALUATION OF WORK. 70 , FEE, PERMIT FEE /A 4 'Z Z. (BUILDINGS lc' $ DJUSTEJDVAAMflJI,3g4' PLAN CHECK FEE 771,1?A SPECIAL CONDITIONS: f .24 �/x b S'. f , -r! �11 /, -/ 576 a 'A' 17 J— 9 ` �� + D� , SCHOOL IMPACT FEE �/� NO, OF BUILDINGS ON PARCEL USE OF NOW ON PARCEL �' TOTAL PEE [ ` 7;t 7/ n OCC. GR/ 3!U/ CONST. TYPEIIV NOTICE SEP ,,,,,TE PERMITS ARE REQUIRED FOR ELECTRICAL PLUMBING, VENTILATING OR AIR CONDITIONING, THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE GRANTING OF A PERMIT DOES NOT PRESUME AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS CF ANY OTHER STATE LOCAL LAW REG ING CONSTRUCTION OR THE PERFORMANCE I I •,NSTi UCTION C:// (Data) ! / %7 f 7L WATER SUPPLY DATE PERMIT ISSUED )0-07/ —i4. HEATING, SPEca4 APPROVArs REuUIREO RECEIVED Nor REQUIRED IS ZONING WORK IS HEALTH DEPT. KNOW FIRE DEPT, TO GIVE SOIL REPORT OR OF SETBACKS FLOOD HAZARD ature of Owner, Contractor = gnT''zed Ow- ' r .±•i [.0 Building DepartmentApprovald- ora ff ` agent having read and understood notice i above. MANUF, HOME - Planning DepartmentApprovalldate OTHER 1 AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. CQMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. .- m Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL i °( (� 7 _a?/ - 5-6 GARFIELD COUNTY Building and Planning October; 11, 1996 .Richard Shively, 655 Aldrea Vista Ct.- Palisade,-'CO 81526 Dear. Mr. Shively: In regard'to your application for a building permit, I will need some additional Material before we can proceed. I. am including a copy of, the plan review correction list. Please address the following issues: 1. A licensed engineer, registered in the State of Colorado must verify the structure as designed or modifiehis design,. that the ,roof load will meet or exceed '44 p.s.f. This calculation must include size, grade and s. Yes of lumber. used. 2. The miniinum'frost depth is 36'inches from grade level to,t,he bottom of footing. 3. The structural drawings of the floor and roof framing must have the engineer's stamp and seal. I will proceed with the issuance Of a building permit when the above requested information is returned ,to me. Sincerely. Don Owens Chief Building Inspector 109 8th Street, Suite 303 945-8212/285-7972 --- Glenwood Springs, Colorado 81601 October 15, 1996 Don Owens Chief Building Inspector Garfield County Building and Planning Glenwood Springs, CO 81601 Dear Mr. Owens: In response to your letter of October 11 and our conversation yesterday regarding my application for a building permit we are providing the following information which we hope will meet with your building codes: 1. Roof design will be modified to include pre-engineered trusses which will meet the 40 p.s.f requirement. A truss design is included. Theme.: X11-also-led`Qthe~l�ivir� 3oorn-area-ether-tlrtheA.=lin g,_. —desigu=as sci y n.an the plan_ 2. Floor joists will consist of 45 Series BCI Joists 16" O.C. with a width of 9 1/2 inches. Specifications are included which indicate a code approved span of 17' - 5" or a three star span of 15' - 8". The maiximum span indicated on our foundation plan is 13' - 8" 3. In our conversation yesterday we discussed the minimum frost depth of 36 inches from grade level to the bottom of the footing. The foundation plan presented indicates a total footing and stem wall of 42 inches. The grade level will be raised to 6 inches providing for the required 36 inch frost depth. I am hoping that these changes and explanations will address the issues raised in order for the building permit to be issued. chard H. Shively GARFIELD COUNTY Building and Planning October 11, 1996 Richard Shively 655 Aldrea Vista Ct. Palisade, CO 81526 Dear Mr. Shively: In regard to your application for a building permit, I will need some additional material before we can proceed. I am including a copy of the plan review correction list. Please address the following issues: I. A licensed engineer, registered in the State of Colorado must verify the structure as designed or modified to his design, that the roof load will meet or exceed 40 p.s.f. This calculation must include size, grade and species of lumber used. 2. The minimum frost depth is 36 inches from grade level to the bottom of footing. 3. The structural drawings of the floor and roof framing must have the engineer's stamp and seal. I will proceed with the issuance of a building permit when the above requested information is returned to me. Sincerely, d'vk (7G.A74.)./AL Don Owens Chief Building Inspector 109 8th Street, Suite 303 945-82121285-7972 GIenwood Springs, Colorado 81601 GARFIELD COUNTY BUILDING AND PLANNNG MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a play ar.d the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes X No (0 Not necessary for this project (2) 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes No su Not necessary for this project )( (2) 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes No (1) Not necessary for this project X as 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes X No (1) Not necessary for this project )2) 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No („ Not necessary for this project (2) 6. Do the plans indicate the size an location of ventilation openings for the attic, roof joist spaces and soffits? Yes X No („ Not necessary for this project (2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow Toads, (a minimum of 40 pounds per square foot in Garfield County) floor Toads and wind loads? Yes No (1) Not necessary for this project c2, 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes )( No (1) Not necessary for this project (2) 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X No t „ Not necessary for this project r2, 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes X No (1) Not necessary for this project (2) 2 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes ?( No (1) Not necessary for this project a? 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase Il EPA certification? Yes No (t) Not necessary for this project X (2) 46 Pre,r (ace, 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No (1) Not necessary for this project )( (2) 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes X No (1) Not necessary for this project (2) 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes , No (1) Not necessary for this project (2) 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes X No (1) Not necessary for this project {2) 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes X. No (1) Not necessary for this project (2) 18 Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from that association, if required by that association, prior to submitting an application for a building permit? Yes j\ No (1) Not necessary for this project (2) 19. Will this be the only residential structure on the parcel? Yes X No If No -Explain 3 20. Have two (2) complete sets of constructions drawings been submitted with the application? Yes X No (1) Not necessary for this project (2) 21. Is this an application for the placement of a manufactured home? Yes No _ 1 If yes, have you specified the size of the unit (min. 20ft x 20ft); live roof load (min.40#); wind design (min. wind speed of 80 mph & 15 Ib. wind load); foundation design; method of anchoring? Yes No (1) Not necessary for this project (2) 22. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No (3) -- )(a.,.`. 23. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Department? Yes X No (3) 24. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes X No (3) 25. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permit? Yes X No (3) 26. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before . Failure to give 24 hour notice for inspections will delay your inspection one (1) day. Yes X No 27. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes X No (3) 4 28. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes". Yes j( No (3) hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. datV.7/10 e Phone: «&.i OYss (days); C (ot,/- Ors -s— (evenings) Project Name: ` cJ�CL SL, ve c Project Address: 9C t'q.,-.c g./,u , CO x(635 Notes: (1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: (3) A. The application may be placed behind more recent applications far building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position far review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy not being issued. PerApp02.95 Effective August 15, 1995 5 Vile/neatit scr fe, uice -(wociatiorc ,.:--•4zo Post Office Box 6006 Battlement Mesa, Colorado 81636 (970) 285-9740 September 24, 1996 Richard & Rosemary Shively 655 Aldrea Vista Court Palisade, CO Re: 40 Promontory Place Dear Mr. & Mrs. Shively, The Battlement Mesa Service Association Architectural Review Committee for Willow Creek Village has received your request for approval to construct a home at 40 Promontory Place following the plan submitted with the revisions you noted. The home color will be Milky White and the trim will be Beanpole. Your request is approved with the following stipulations: All general building and site improvements construction for any project shall be completed and shall have issued a Certificate of Occupancy from the Garfield County Building Dept. no later than nine months after the Building Permit issuance date. The completed landscaping and revegetation of the improved lot shall be completed no later than six months from the date of Certificate of Occupancy. An additional maximum four month extension may be granted by the Architectural Committee if the Certificate of Occupancy was issued shortly prior to the non -growing winter months such that landscape construction could not diligently proceed. If in the course of construction and landscaping, the use of any vacant adjoining property for material and equipment storage, delivery of materials or any other purpose, is prohibited unless written permission is received from that property owner. A copy of which should be sent to this office. Failure to obtain permission, is considered trespassing under County and State Laws and violators can be subject to penalties there under. Please submit your landscape plans prior to commencing with your landscaping. Thank you for complying with the Covenants of your Association. Sincerely, Jane L. Chapman Association Manager - Battlement Mesa Service Association w A 17 ___ALS___61 _X462_41_0_0 ---1-15-4I-7-62 • Ue _I 154.7 6 --------- -~ .ir6PECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT G RFIELD COUNTY, COLORADO Date Issuedj Vilkoned Area Permit No 6113 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building inspectoorrja IMM IATEL ECOME NULL ANID. Use Siam5- f f 1,/bx43k X4,0 to c ". e ,. Contractor 0 tiiikt C - Address o egal Description Owner 1 Ord Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final inspection. INSPECTION RECORD Footing J Oh ,/ Foundation / "a /9C /t Underground Plumbing Rough Plumbing - Chimney & Vent Gas Piping Insulation 2-3-Cii'?� Drywall 2— rp_on, Electric Final (by State Inspector) Electric Rough (By State Inspector)/ -/5-5g._ Framing 1� (To include Roof in place and Windo`Ws and Doors installed). Final Septic Final ti i - Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVED DO NOT DESTROY THIS CARD Date COVER F PLACED OUTSIDE COVER WITH CLEAR PLASTIC