HomeMy WebLinkAboutApplication- PermitNo. 6054
GARFIEIJ) COUNTY
BUILDING, SANITATION and PLANNING DEPARTMENT
109 8th Street Suilc 303
Glenwood Springs, Colorado 81601
(303) 945-8212
Job Address 0350 Ingersoll Lane, Silt
Nature of Work Building Permit
Use of Building Manu. Home on Foundation
Owner Orval & Elsie Sackrider
Contractor Dave Gibbons
Amount of Permit $
447.09
Permit: 149.75
Plan : 97.34
Set Up Fee:200.00
Paid $297.34 8-19-96
Date September 5, 1996
S. Archuleta
Clerk
BUILDING PERMIT APPLICATION
GARFIELD COUNTY. COLORADO
Applicant to complete numbered spaces only. PERMIT NO. 6 0-5- PARCEVSCHED NO.
JOB ADDRESS
1
2
3
4
5
6
7
8
LEGAL
QESCR.
LOT NO.
O S5,5 _Z e0-SoL Liv 5/
BLOCK
SUBDIVISION
.S 67 Tlitesc,
OWNER(` :it.
CONTRACTOR &rt./pod",
ARCH}TECT OR DESIGNE
9
ENGINEER
S.F OF BUILDING
USE OF BUILDING
Hvo
ADDRESS ()360 3G iSoiri 444. ^^ 1‘, i►
ADDRESS
d
,ADDRESS
ADDRESS
S. F OF LOT
PH.Yb 41A1
PH.
PH.
HEIGHT
CLASS OF WORX: iNEW ❑ADDITION D ALTERATION ❑REPAIR ❑ MOVE D REMOVE
(1_,UV9 09z)duicte__407)
DESCRIBE WORK:
WK. PH_
LICENSE NO.
LICENSE NO.
LICENSE NO.
NO, OF FLOORS
10
GARAGE/113Rd DOUBLE
CARPORT SINGLE DOUBLE
11
DRIVEWAY PERMIT Npt4g
CtQ $'SITE SEWAGE DISPOSAL PERMIT
SITE PLAN tf
VALUATION OF WORK: $ ADJUSTED VAL$
SPECIAL CONDITIONS,
j1/()095' PS 4.10 0 I d
PLAN CHECK FEE 7A 3 i/
SCHOOL IMPACT FSEflo CO
PERMIT FE(/ 9
NO. OF BUILDINGS ON
PARCEL
USE OF BUILDINGS NOW ON
PARCEL
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELI, i L.AU, r LUM:,INC, 'HE^,TING,
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 15
NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED
OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK 15
COMMENCED,
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THS APPLICATION AND KNOW
THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE
AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
LOCAL LAW EGU TING CONST UCTION OR THE PERFORMANCE OF
TRUCT10
(pate) G.+ `� rF`24
Signature at Owner, Contractor or authorized agent having read and,. erstood notice a ave
Building Department Approval �/� �Ianning D .a entApproval/date
TOTAL FEE 797 Oaf
WATER SUPPLY
OCC. GR,
CONST. TYPE
DATE PERMIT ISSUED 9-5-9,4
SPECIAL APPROVALS
REQUIRED
RECEIVED
ZONING
HEALTH DEPT.
NOT REQUIRED
42.E60 .576-744
.4105F.31VOIVAl L/
flr&' A.
FIRE DEPT.
SOIL REPORT
SETBACKS
FLOOD HAZARD
MANUF. HOME
OTHER jS D 5 I / _CO. D a
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE INITIAL
.-/9 --96 ',.1917. &» &' Q' c.
7
GARFIELD COUNTY BUILDING AND PLANNING
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
MANUFACTURED HOMES
ADDITIONS
ALTERATIONS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and
expedite the issuance of a permit it is important that complete information be provided.
Adequate and complete information will prevent delays in the plan review process.
Reviewing a plan and the discovery that required information has not been provided by the
app_':::ant may result in the delay of the permit issucnce and in proceeding with building
construction. The owner or contractor may be required to provide this information before
the plan review may proceed. This causes delays because other plans that are in
line r
review may be given attention before the new information may be reviewed afterit has
been provided to the Building Department.
Please review this document to determine if you have enough information to design
your project and provide adequate information to facilitate a plan review. If you do
not, it may be helpful to obtain a book titled "Dwelling construction under the
Uniform Building Code. This book is available to you through this department at our
cost. Also, please consider using a design professional for assistance in your
design and a construction professional for construction of your project.
To provide for a more understandable pian in order to determine compliance with the
building, plumbing and mechanical codes, applicants are requested to review the following
check list prior to and during design. Applicants are required to indicate appropriately and
to submit completed check list at time of application for a permit:
For the placement of a manufactured home, questions numbers 1-4 and 19-28 are
the only questions that need to be addressed:
1
1. Is a site plan included that indicates the distance of the proposed building or
addition to property lines, other buildings, set back easements and utility
easements?
Yes
No (n Not necessary for this project (2)
2. Does the site plan include the location of the I.S.D.S. (Individual Sewage
Disposal System) and the distances to property lines, wells (on subject
property and adjacent properties) , streams or water courses?
Yes No «, Not necessary for this project (2)
3. Does the site plan indicate the location and direction of the County or private road
accessing the property?
Yes V No (1) Not necessary for this project (2)
4, Do the plans include a foundation plan indicating the size, location and spacing of
all reinforcing steel in accordance with the uniform building code or per stamped
engin?ered design?
Yes No (,) Not necessary for this project (2)
5. Do the plans indicate the location and size of ventilation openings for under floor
crawl spaces and the clearances' required between wood and earth?
Yes No (1) Not necessary for this project (2)
6. Do the plans indicate the size an location of ventilation openings for the attic, roof
joist spaces and soffits?
Yes No (1) Not necessary for this project (2)
7 Do the plans include design Toads as required under the Uniform Building code for
roof snow loads, (a minimum of 40 pounds per square foot in Garfield County) floor
loads and wind loads?
Yes No („ Not necessary for this project (2)
8. Does the plan include a building section drawing indicating foundation, wall, floor
and roof construction?
Yes No (1) Not necessary for this project (2)
9. Does the building section drawing include size and spacing of floor joists, wall
studs, ceiling joists, roof rafters or joists or trusses?
Yes No (1) Not necessary for this project (2)
10. Does the building section drawing or other detail include the method of positive
connection of all columns and beams?
Yes No (1) Not necessary for this project (Z)
2
11. Does the plan indicate the height of the building or proposed addition from the
highest point of the building or addition measured at mid span between the ridge
and the eave down to existing grade contours?
Yes No (1) Not necessary for this project (2)
12. Does the plan include any stove or zero clearance fireplace planned for installation
including make and model and Colorado Phase II certifications or phase II EPA
certification?
Yes No (1) Not necessary for this project (2)
13. Does the plan include a masonry fireplace including a fireplace section indicating
design to comply with the Uniform Building Code Chapter 37?
Yes No (1) Not necessary for this project (2)
14. Does the plan include a window schedule or other verification that egress/rescue
windows from sleeping rooms and/or basements comply with the requirements of
the Uniform Building Code?
Yes No (1) Not necessary for this project (2)
15. Does the plan include a window schedule or other verification that windows provide
natural light and ventilation for all habitable rooms?
Yes No (i) Not necessary for this project (2)
16. Do the plans indicate the location of glazing subject to human impact such as glass
doors, glazing immediately adjacent to such doors; glazing adjacent to any surface
normally used as a walking surface; sliding glass doors; fixed glass panels; shower
doors and tub enclosures and specify safety glazing for these areas?
Yes No (1) Not necessary for this project (2)
17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water
heaters indicated on the plan?
Yes No („ Not necessary for this project (2)
18 Do you understand that if you belong to a homeowners association, it is your
responsibility to obtain written permission from that association, if required by that
association, prior to submitting an application for a building permit?
Yes No ci Not necessary for this project (2)
19. Will this be the only residential structure an the parcel?
Yes No If No -Explain
3
20. Have two (2) complete sets of constructions drawings been submitted with the
application?
Yes — No (1) Not necessary for this project (2)
21. Is this an application for the placement of a manufactured home?
Yes '1 No
If yes, have you specified the size of the unit (min. 20ft x 20ft); live roof load
(min.40#); wind design (min. wind speed of 80 mph & 15 Ib. wind load); foundation
design; method of anchoring?
Yes No (1) Not necessary for this project (2)
22. Have you designed or had this plan designed while considering building and other
construction code requirements?
Yes 4-, No (3)
23. Does the plan accurately indicate what you intend to construct and what will receive
a final inspection by the Garfield Building Department?
Yes _,1 No (3)
24. Do you understand that approval for design and/or construction changes are
required prior to the application of these changes?
Yes No (3)
25. Do you understand that the Building Department will collect a "Plan Review' fee
from you at the time of application and that you will be required to pay the "Permit
Fee" as well as any "School impact" or "Septic system " fees required, at the time
you pick up your building permit?
Yes •t. No (3)
26. Are you aware that twenty four (24) hour notice is required for all inspections?
Inspections will be made from Battlement Mesa to West Glenwood in the
mornings and from Glenwood Springs to Carbondale in the afternoon.
Morning inspections must be called in by 12:00 p.m. the day before; afternoon
inspections must be called in by 5:00 p.m. the day before . Failure to give 24
hour notice for inspections will delay your inspection one (1) day.
Yes - No
27. Are you aware that you are required to call for all inspections required under the
Uniform Building Code including approval on a final inspection prior to receiving a
Certificate of Occupancy and occupancy of the building?
Yes No (3)
4
28. Are you aware that the person signing the Permit Application whether the "Owner",
"Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the
application is the party responsible for the project complying with the Uniform
Codes".
Yes No (3)
l hereby acknowledge that i have read, understand and answered these questions
accurately to the best of my ability.
signature date
Phone: `f ,..;-• f ".. (days); (evenings)
Project Name:
Project Address:
Notes:
•
(1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Building
Official prior to beginning the pian review process. Delays in issuing the permit are to be expected. Work may not proceed without
the issuance of the permit.
(2) If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the
information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please
expect the following:
A. The application may be placed behind more recent applications for building permits in the review process and not
reviewed untii required information has been provided and the application rotates again to first position for review.
B. Delay in issuance of the permit.
C. Delay in proceeding with construction.
(3) If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued
or a "Certificate of Occupancy not being issued.
PerApp02.95 Effective August 15, 1995
5
— 1 9-96 M 01'4
1
;_06. _ COLO LJET
ih
DATE :
,: TO: - c. r f.d
COMPANY:.
REGARDING:
rl
Phone 19701 625-4816 • Fax 19701 625-4923
151 E. 21st St.
RIFLE, CO 81650
FACSIMILE TRANSMISSION
0 1
Nongiimimiummimmiumml
PAX # 1-97O-625-4923
PHONE .1-970-,625-4916
FROM ; fi
TIME:
NO. OF PGS.
+ Cover
THIS MESSAGE IS INTENDED ONLY FOR THE USE OF THE INDIVIDUAL OR ENTITY TO wHICH
'i1'IS ADDRESSED AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED, CONFIDENTIAL AND
;EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. If the reader of this message is
;not the intended recipient, please do not read beyond this cover page: you are
hereby, hotified that any dissemination, distribution or copying of this
Communication is prohibited. Please notify us :immediately by telephone and return
the original meaaage to us via the U.S. Postal Service.
THANK YOU.
EX
T Tr'
15 ., COPY
C w9�O �t 1
iii. E 1ti• .115 CSN SSIf
Page..., of
WEST
. .
'95 B5:04Pi1 AfiEtfiCANi-tOmESTAPIN
/ •
• •
•
••
";.-•
• !:
.4
A " I
sot. o•
A HQNE :A- BURL - •N
SER#' 11 oilf, if,Fis-ibu
— —0' f,..,-- g
, Jcla• ley
cIOPth
Kit Cer
;i1
1/4" & I od .10c!s 753
"IES: Li E -LE
1118EMISIdewell
DEC*" ,!..." •
SHIP;
.....1
-
y. SIZ . 2; ' •
ORM
V
x6
Roof Insulation: R. 3p 6
7 1 132: CT- IA Not; C.11 -713-
1
Root insured n: Ct-14
172 132: CT Ed e• e / (
' .. UTILITIES • 00Rs & WilWOWS
-fill
l•
Total Erect
501
Front Door: IT. 34x.r. W/Storrn 5
103
2.1 • ntp ON Go: Incl in 102
ront Door, t tl i•iTAFBtorm .
• IIKkalli
111
WM: 30
.3
runt Door, 3880 StI Wars
82
11
W Iii: 40 Gal EIcc no 10. 4804
Rear Coon Col -a
ear Goon 8 Lite ti WfStorm
• 3
113
WM', 50 G ec
607
Grid Mind' Math
Wra ed order
114
WM: 30 a Gas
KardlEMIX
kl.1•1
oor: xtra ntenor
115
WIw 40 Oal Goa
OEM
Door: &kiln Glass .
I331
121
Furn: Ga is LtOi.
610
Atrium Door •
MAI
1
urn: OG
I1[
indows, term
• N
125
Up • ec urn.
LtaillilriMTMTKinT11
• 11-1 -
140 ea
127
OrdloW Gas Fum.
n401
634
Wndows, Vinyl 314 Tilt
, 1
128
17'7 RF Vont WSW& twitch
!1
402
- oll•oods Util LL
1
131
'txtra Ext Recap 135 a)
Egan
2132
1111111111
Wire/EraCt 0 Fans (S35ea
, AP-PLIANCES
01 Rettig: 15 C FF 4
133
-C-ran W/Lite 1<4 (31 .5 ea
134 :
'Phone Jacks /$35 ea)___
702 efri : 15 CP FF
135
TV Jacks ($35 ea)
704 Perri.: Side b Ida. 20 C. .
—
141
Sin. le Lever Faucet
705 Orn t Re!
8A PRICE
14'
b• OM Ice akar*
EOM
Iceme er, installed'
Std Gas Plan a
IN
1 3
-Ibg Only Gas terMai
WWII
•••-
144
Dishwasher: Plumb 3 Wire
-70
a ilEll Deluxe Gas Ran
'4T37"
-t
-but off Valves
M11/11:XIEOM1MON1111"
21 mit -one
1
151 '. 'Ffeezer Recep w/20 Amp Brkr
4161
Bilrioogi).4,11s: ($25 ea)
4722 shwasher
X
193 iii. 4, 1
741 Dispasai .
194
742
1972 Tax .0 ex OM
195
MN
DE - ORS
_... —
INSuLATION/CON TRU • p•
d •
,,.,
MEM
441
,.._
1,1011116i z.vilw i • .•
Floor Insulation: -.11 d kr 753
_ _
Kit Sa S.1- b , LA • _iit
•
1 loot nsu at on: 11-1 754
Kit Cer
1204
1/4" & I od .10c!s 753
41: Ceramic Behind Ran e
1118EMISIdewell
InsuIation: -11 761
M$: CT.TILL
al Ins!: R-190 a. 76
M: CT CT a. .r.
ORM
V
x6
Roof Insulation: R. 3p 6
7 1 132: CT- IA Not; C.11 -713-
a
Root insured n: Ct-14
172 132: CT Ed e• e / (
.—_
-fill
Tile Backs lash Mat
-0`1T111ttEVEEZ'
•
atat
2351._ MEM
MISCELLANBIOV3 Tub Ora • a, Guest Bath
_Mii0111
NEkill
ire taco,
• IIKkalli
Sin e Pack
1
1292 WIND ONE 11
82
PorcelainLtiviag.
EgTERIOR
828
R61 Int boor Peel(
• 3
CoIcr:Sod a
or, r RI -
331
3
Grid Mind' Math
Wra ed order
/MEM•ion
sh;r. les.
KardlEMIX
'in1
king; 60' nder
I331
grain Over Kr
MAI
391
lin :
611234aTIMINIMNP
NEN
• N
• 11-1 -
COVERING 1
:02 - Allowance
n401
FLOOR
Rollgoods KrT 6, q cl..([
, 1
904
Carpet Instaitatro;
!1
402
- oll•oods Util LL
1
906
Surohar•e
Egan
- o II ooda ntr • 1
1111111111
- • • •C14112k N
CC=
1411
on,
:
—
Kalil
.,• .,
8A PRICE
MEtilni
a Li •r• C. lare1t.A11•11 1
95
W
IN
g53 AOV
WWII
•••-
TOA •Til R
•13,- 5 1.962
te Pee
II
501
boor Util Cab -MOF
1
965 H D Hurricane C- st
MRY113
Door Linen ab•Iig
:KINN
V; .TL
GUN
HTLF OVER Mb .
1972 Tax .0 ex OM
WINN
MN
110121:nalr27/7- .
ANN 0 AL 1NVE5Trvi NT
-P 0 2
7
�• I
=.�, p (S
�•_
1
•
i
uS
o.
•
3
al
(f) r
1L
ODU$Lc -WIDE
.
LI
.
N
E
/ \•
.
I
o
�
ODU$Lc -WIDE
/
a
rr e
,'1Q
cruet/y-6-1 5) i 41
C.------- '
\ \ \
\.\.
•-., '---7
•---,._ :.r- ,
1 7' 4,-74•—•--.1F a•rf=m _pi/7 /47 ..:,..-)
'..-^
61
-,LZ
„►91
_4c
_491
6
.*
0a
0
Da
W
0
N i
�ry
to 1
non
L—
2
M
w
7431 1MI'1q
OI O
N —. w
M...�
Al
• LA...-. 0 0 1
„BZ
.LC 2/1 OE i/1 O4
I
W
h
R saI
I
I
.;s
-Z/1
2=W
ax O0.
O 0 W W
❑ a
93'
ce
S7
0
BrOC • 9SOt
'MID I 'idO
• -Z/1 12,
M
rvrvIII
1
1
O
LIFESTYLE SERIES
0
▪ t ,
to
11
:NBA CAM
11011lEStil 0.13.0e1 et
aea,hMa 01r1, 1uK ooaCRam,
PRODUCTION LAYOUT
�
J
...r L
Y
0
I WF
▪ �tiruD
- N '
tAriNc pr.�F
'3HIaKLS3WOHNUOIaad NdTO:E2 9E, 21 `inld
AUG 12 'SE
OEs: �� JFI'1 HII ERI09,HH?C sTeIRIX,.
UTILITY HOOKUP LOCATIONS
(DOUBLEWIDE SERIES)
p,1/2
MODE_
FLOOR
LENGTH
ELECTRICAL
DRAIN
WATER
OAS
A
8
A
e
I,
._i- _ 4 B—HALF
A
7
A
CENTER LINE OF UNITS
H5836
A --HALF
MAIN I—BEAM
53'--0'
12
#
LENGTH
31 —5"
'See Table 6alewi
MODE_
FLOOR
LENGTH
ELECTRICAL
DRAIN
WATER
OAS
A
8
A
B
A
5
A
0
H5836
72 —0"
53'--0'
12
28'-8
6'-4
31 —5"
6 —10
46'-0'
10'-11'
836-4S
76"-0"
61'-8
12
30'—O"
6'--4"
32'-9"
fi"-10"
46'--0"
10'-11"
HS716
HS724
52 —0"
60'-0"
4'-4"
10'-8"
4'-11p
20"
22'--O"
2S--8"
7'--7"
8'-6"
23'-4"
7'--3
24'-8'
1 1'-8"
23'-6"
8'-0"
17,-4"
S,
1 H3775
72'_0"
82'—O"
18"
28-8"
7.-5"
i8'—C"
7'-11"
HS750
46'-0"
42'-8"
5'—l0"
34'-0"
8'-6"
23'-6"
5'-0"
31'-4"
14-11"
HS760
56'-0"
40'-0'
1'-4"'
19.— "
4.-8„
54.-0"
15`-6"
37'-4"
15'-6"
$4. .- f:
ii•'
/?,..Qr— T
'8 c
7)._ C!'
I "e
M,
' a`
T
_
I
NTE_ ADD 4" 1 WIDTH ANO LENGTH DIMENSIONS WHEN OPTIONAL 6" £xTERcOR WALLS
ARE USED. I—BEAM MOTH 8 SAM ON ALL HOUSES AS SHOWN IN LAYOUT MOVE.
LE7
I�DAMN
DATE DWN CHKD LEF REVSIGIJ
PATE
OWN
CNKC
A PCO 01-2328
3-13-95 TEJ
PCO 01-2361
8-14-95
TJ
AMERICAN
COSI OIt RTION
darelphl by wENSECTION-
ALL MICPiTi RESETM.D, CaftrNA.Lip 149; rolf
1,(mkN 14WI'1 Carp. TMr aaysny pro 4:4
fA uNd
r0 ha.ELchm lfix+si.
yWM'g����I.�pl.ae.Yd"
p
WMA %l
unury
DRAWN:
DATE:
SHEET
1
QF 1
TITII. f HOOKUP LOGATtON$
(DOUBLEWJDE SERIES)
APPRD,;
AH S-5
• 11
CZ
try
O
N
• /J
•
O
cl .. 1-.'.4,_ t•-.
. 01g -m. .. ..
41 az
1
t1 c •
P r
v
Th. .e")
Pi.
3
Lu
00
.
CI
.
3
00.
Y
.T
0
Pi.
3
Lu
00
c
A P.LW Vx4i1
•
•
M1
•
•
� L
_¢
4
; • I
• .
.. •
•43
•
..._)
4A 4
,.,1
› . 4 ....1.
--271- L.4 .....„
•
A 1)e- 'k.• 4 -
v, -t
. .,4 . E..
3 ..t. L ....t,
.•.. c.4
.,..
.., ..z... - .Lii
.• 1
- 7 -
!...I
CI lzk-. CI
..-
. . t---• `Ct < .
(1,1 L'4•
'>.
• -• 1"
. 4.• -ck,
.
4
et aZ._
"td
• c.C.
ai .. -•-. ri
CI --,--
_
1-41
14
SI" ia
co
. • -
4
1.1eAloorlicr OWN SILL 111U1 tit MAUI: thitiLtild
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
RFIELD COUNTY, COLORADO
Date Issued. .. r..
Zoned Area
Permit No 0.41
1
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspec or and IMMEDIA ELY BECOME NU D VOI
Use f)2,t.ij Do ` o s + , A:.)
Addres or Legal Descrip ' t 7...44#. Lc_ tei7Aiei S
Owne r l; rid 1 Contracto 6 ' OUZ
Setbacks
Front Side Side Rear
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing _ ,F
Foundation
Underground Plumbing
Rough Plumbing
Chimney & Vent
Gas Piping / / _ z_
Electric Rough (By State Inspector)
Insulation
Drywall
Electric Final (by State Inspector) r/
Final i
Septic Final
Framing Notes:
(To include Roof in place and Windows
and Doors installed).
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado.
APP V E D DO NOT DESTROY THIS CARD
DatR&l411k
By