HomeMy WebLinkAbout13-OWTS Permit SetPARCEL ID: 2393-354-00-039 LEGEND I OWTS DESIGN CALCULATIONS 2016: EXISTING ROADWAY/DRIVEWAY 3 -BEDROOM RESIDENCE AND 3 BEDROOM CABIN: r i • (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOM) • (75 GAL/PERSON/DAY x 1 PERSONS/BEDROOM x 3 BEDROOM) 0 _ PROPERTY PROPOSED SEPTIC GRAVITY LINE • DESIGN FLOW = Q = 675 GALLONS 10' BOUNDARY LINE. ss ss PROPERTY BOUNDARY TANK SIZING: SETBACK. ABANDON EXISTING • SECTION 43.9 B. TABLE 9-1. 1250 PLUS TWO ADDITIONAL BEDROOMS 4" PVC LINE TO Ni N.�, FIELD. SETBACKS AT 250 EACH OR 1750 GALLONS. ss • USE EXISTING 2,000 -GALLON, TWO-COMPARTMENT TANK WITH DOSING PUMP. ABSORPTION AREA SIZING: 756SF MOUNDED SAND FILTER 1" 12 PERFORATED, PIPES. W m (-1 W Z O O I-0 u)SYSTEM. • LTAR RATE = 1.0 GAL/DAY/SF (USDA TYPE 0 UNDERLYING SOIL. u) 0 Z SYSTEM DESIGN WILL BE A 3' SAND MOUND WITH PUMP) 0' IJ m GRAPHIC SCALE 1 Q • CALCULATED ABSORPTION AREA = A=(Qd/LTAR)=(750/1.0) I 1 20 0 10 20 40 80 • PLUS ADJUSTMENT FACTOR OF PRESSURE DOSED BED OF 1.0 ° : J ss ^ - - - = HEAVY •• Qd = DESIGN FLOW = GAL/DAY •• MIN. ABSORPTION AREA = 750 SF - oci - - INSPECTION WELL ABANDON EXISTING VEGETATION (IN FEET ) 63.2' o -- --- (. ) TYP 4" PVC LINE TO 1 inch = 20 ft. TOTAL DESIGN AREA FOR 6 BEDROOMS = 756 SF 6177 FIELD. -TM 2" 2" PRESSURE PIPE IN MOUNDED SYSTEM: 6.C - 178 • ABSORPTION AREA PER DESIGN 756 SF. VEGETATION •• GROUND WATER PER SOILS REPORT AT 3' BELOW EXISTING GRADE. OVER DIG OF 3' TO REMOVE TOP SOIL AND CLAY LAYERS, THEN REPLACE WITH 3' OF SAND WITH TOP OF SAND 86LF OF 2" PRESSURE LINE TO MANIFOLD BOX. LINE. FILTER AT EXISTING GRADE, THEN 1' OF SCREENED ROCK INFILTRATIVE SURFACE AND THEN 1' OF TOPSOIL WITH TOP OF TOPSOIL 2' ABOVE OF EXISTING GRADE. •• INFILTRATIVE SURFACE SET 3' ABOVE WATER TABLE PER UNLINED SAND FILTER DESIGN CRITERIA FOR LT1 TREATMENT. •• FIELD VERIFY DEPTH OF GROUND WATER AND SUBSOILS AT LOCATION OF PROPOSED FIELD AFTER EXCAVATION BY ONSITE LINE TO SLOPE BACK TO TANK. EXISTING 2,000 GALLON SEPTIC TANK WITH HIGH HEAD DOSING PUMP ATTACHED TO EXISTING GRAVITY EXISTING 4" PVC LINES GENERAL NOTES HEAVY SEWER LINE. VEGETATION N FROM HOUSE 1. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. 2. THE BOTTOM OF THE BED SHALL BE LEVEL. 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE BED AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD. 5. THE SAND MUST BE THOROUGHLY SETTLED BY FLOODING OR OTHER MEANS BEFORE THE DISTRIBUTION IS PLACED AT THE FINAL GRADE. 6. BED BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 8. BOULDERS EXISTING WITHIN THE BED SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 9. SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ORDERING SYSTEM PARTS. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATIONS AND DEPTHS OF ALL EXISTING BURIED UTILITIES. 11. CLEAN OUTS ARE REQUIRED WITHIN 5 FEET OF THE HOUSE FOUNDATION, AT ALL BENDS EQUALING OVER 90 DEGREES AND ATA MAXIMUM OF 100 LF SEPARATION ALONG THE SEWER LINE RUN. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATERTIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 13. PUMP SIZING TO BE FINALIZED UPON ORDERING OF THE TANK AND FINAL ONSITE APPROVAL OF THE FIELD LOCATION. 14. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO ONE-HALF FOOT ABOVE FINAL GRADE. VEGETATION LINE. r I I �� (I' / `%., *.... '4.'4. TO AND W TANK LOCATION. N U) N LAWN AREA JJ ••44 ` `� SHED 0 N KARL HANLON �'�`GOv��'A HIGH COUNTRY ENGINEERING, INC. x GARFIELD COUNTY, COLORADO .. , , (A L m 1517 BLAKE AVENUE, STE 101, 271 WILLOW LANE C H Gig E G � LENWOOD SPRINGS, CO 81601 W z ONSITE WASTEWATER �ti �PHONE (970) 9458676 - FAX (970) 945-2555 p TREATMENT SYSTEM �INEE�`� VYWW.HCENG.COM . LOCATIONS IREMENALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET STATE0 16. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNT/AS BUILT DRAWING. 17. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. GARBAGE DISPOSAL INSTALLATION AND USE IS ALSO DISCOURAGED. 18. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN FROST DEPTH. 19. DUE TO THE ELEVATION OF GROUND WATER, THE ENGINEER MUST BE ONSITE AND A TEST PIT ADJACENT TO FIELD AREA WILL NEED TO BE DUG TO VERIFY THE SOILS SELECTED AND REVIEW WATER TABLE DEPTH. //, u) // 1 00' WELL / SETBACK. / / HEAVY / / VEGETATION / / / H 0 U S E -` 3 - B E D R 0 O N \` EXISTING • 4" PVC • LINE. ` `• W / 20. SITE PLAN INFORMATION, NUMBER OF BEDROOMS, SIZE OF HOUSE PROVIDED BY OWNER. 21. LEACH FIELD MUST BE SURVEYED AFTER INSTALLATION FOR ACCURATE LOCATION FOR FINAL FIELD INSPECTION, AS-BUILTS AND WRITE-OFF./ 22. NO IRRIGATION DITCH FACILITIES ARE TO BE CONSTRUCTED ON THE SITE. ONSITE LANDSCAPE IRRIGATION WILL NOT BEI APPLIED TO THE OWTS SYSTEM AREA EXCEPTING TEMPORARY FACILITIES TO ENCOURAGE GRASS GROWTH FOR THE FIRST YEAR. 23. DOMESTIC WATER IS TO BE PROVIDED BY THE ONSITE WELL. 24. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY/STATE REGULATIONS FOR ONSITE / SITE WELL / IN CABIN, NORTHWEST CORNER. ' LAWN AREA • HEAVY • VEGETATION ‘ •0 ' I I I ___I WASTEWATER TREATMENT SYSTEM DESIGNS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. R100.0' 25. CONCRETE SEPTIC TANK SHALL COMPLY WITH THE STRUCTURAL DESIGN CRITERIA OF ASTM C1227-12 (STANDARD SPECIFICATIONS FOR PRECAST SEPTIC TANKS). CABIN I DRIVEWAY 3 - 3 E D R 0 0 IV I Exhibit 26. SOILS INFORMATION PROVIDED BY HP GEOTECH, PROJECT NO. 1060568, DATED JULY 26, 2006. SOIL GRADATION CONTAINED GREATER THAN 35% ROCK WHICH RESULTS IN LTAR OF 1.0 GAL/SF. DESIGN OF SAND FILTER MOUND SYSTEM BASED ON PIT PROFILE WITH 1 TO 1.5' OF TOPSOIL OVER 1 TO 1.5' OF SANDY SILTY CALY OVERLYING SILTY SANDY GRAVEL WITH COBBLES AND SMALL BOULDERS. I 1 ' ' [ MOUND SYSTEM SPECIFICATIONS ‘ / 1 3 1. GRASS, SHRUBS AND TREES SHALL BE CUT CLOSE TO THE GROUND SURFACE AND REMOVED FROM THE SITE. 2. THE EXCAVATED BED SITE SHALL BE TILLED TO A DEPTH OF 8 INCHES TO ROUGHEN THE SURFACE AND INCORPORATE THE VEGETATION.` THIS CAN BE DONE WITH A PLOW OR CHISEL TEETH MOUNTED ON A TOOL BAR ATTACHED TO THE BUCKET OF A ` ` / / / BACKHOE. 3. A LAYER OF SAND SHOULD BE PLACED ON THE TILLED AREA. PLACEMENT OF THE SAND SHOULD BE SUCH AS NOT TO RUT OR COMPACT THE TILLED AREA. ALL WORK SHOULD BE PERFORMED FROM THE SIDE SO AS NOT TO COMPACT THE TILLED AREA. 4. PLACE THE PROPER DEPTH OF SAND, THEN FROM THE SAND/GRAVEL INTERFACE AREA WITH THE AREA BOTTOM BEING LEVEL. 5. PLACE THE SCREENED ROCK (AGGREGATE) TO THE SPECIFIED DEPTH AND AREA. • PROPERTY \ LINE. \ `/ \` SHED SHED / / / / / 6. PLACE THE PRESSURE DISTRIBUTION PIPE, CONNECT IT TO THE SEWER AND COVER WITH AGGREGATE. 7. COVER THE AGGREGATE WITH A GEOTEXTILE FILTER FABRIC. \ i `� �/ 8. PLACE A MINIMUM OF 12 INCHES OF SUITABLE SOIL COVER ON THE SIDES OF THE BED AND TO THE NECESSARY DEPTH FOR GRADING ON THE TOP OF THE BED AND SLOPE ATA 4:1. I f ����„`a a� 0 (/C 9. FINAL GRADE THE BED AND SURROUNDING AREA WITH LIGHT WEIGHT EQUIPMENT SO SURFACE WATER MOVES AWAY FORM THE BED AND DOES NOT ACCUMULATE NEAR THE BED. 10. SEED AND MULCH THE ENTIRE EXPOSED AREA TO AVOID EROSION. LANDSCAPE IWTH SHRUBS AND PLANTS AS DESIRED. PRESSURE DOSING NOTES I I "OR' i 0 ��® ,r /:-40 " 29975 r '�I �c,�0 1� O i 1. MINIMUM DOSING SHALL BE 20 GPM PUMP AT 24 TOTAL DYNAMIC HEAD. DRIPLINE SHALL HAVE 16" HOLES DRILLED 4' ON I CENTER FACING DOWN. \��Nt�I-�'� `����� ~ Table 7-1 Minimum Horizontal Distances in Feet Between Components of an On-Site Wastewater Treatment System Installed After November 15,1973 and Water, Physical and Health Impact Features Ai- Spring, Well, Suction Line Potable Water Supply Line Potable Water Supply Cistern 1 Dwelling Occupied Building Building 1 Property Lines, Piped or Irrigation Subsurface Drain, intermittent Irrigation Lateral, Lake, Water Course, Irrigation Ditch, Dry Gulch, Cut Bank, Fill ' Area Septic Tank 42.0' - Ditch Drywell, Stormwater Stream, Wetland (from 0-------- \- EDGE OF GRAVEL --- -----------, I Infiltration Structure Crest) 3.0 • • b 43.10 Design Criteria- Soil Treatment Area (TYP.) CO r itTreatment .. Septic Tank, Higher Level Unit, Dosing Tank, Vault. 502 102 25 5 • 10 10 50 10 _ p - "o Table 10-1 Soil Treatment Area Long-term Acceptance Rates by Soil Texture, Soil Structure, Percolation Rate and Treatment Level 1BED END PIPES - Long-term Acceptance Rate (LTAR); Building Sewer or Effluent Lines 50 ? 10 2520 102 102 502 102 - (SOLID PVC) • •� Soil Type, Texture, Structure and Percolation Rate Range Gallons per day per square foot - Soil USDA Soil Structure- USDA Soil Structure- Percolation Treatment Treatment Treatment Treatment Treatment STA Trench, STA Bed, Unlined Sand Filter, Sub-airfare Dispersal 1003 252 25 20 10 25 503 26 5 Type USDA Soil Texture Shape Grade Rate (MPI) Level 1' Level 21 Level 2N1 I Level 3' Level 3N''` System, Seepage Pit \A*" } Salt Type 1 with more Minimwn 3-foot deep Lined Sand Filter 50 102 25 15 10 10 25 10 5 `' 0 than 3396 Rock (2mm); Soil Types 2-5 with more Y - 0 (Single Grain) <5 unlined filter Minimum 2-foot deep unlined sand filter regutredZ 1 1 14''0 BED PIPES than 60% Rock (>2mm) sand required Lined Evapo-transpiration Field or Outside of Berm of Lined 50 10 25 15 10 10 25 10 5 (PERFORATED PVC) 2" SCH-40 PVC FROM SEPTIC TANK 1 Sand. Loamy Sand - ❑ 5-15 0.80 1.25 1.25 1.40 1.40 Wastewater Pond INSPECTION WELL (TYP.)252 REFER TO FLUSHING DETAIL (TYP.) 2 Sandy Loam, Loam, Sit Loam PR (Prismatic] BK (Blocky) GR (Granular) 2 (Moderate) 3 (Strong) • 16-25 O.i3o 0.9D 0.90 1.00 1-00 Unlined Sand Filter in Soil With a Percolation Rate Slower than 60 Minutes per Inch, Unlined or Partially Lined Evapotrans- System, Outside Berm 104 25 15 10 25 25 15 10 BED PLAN 2A Sandy Loam, Loam, Silt Loam PR. BK, GR 0 (none) 1 {Weak} Massive 26-40 a.50 0.70 0.70 0.80 0.80 piration of of Unlined Wastewater Pond, or System Not Relying on STA for Treatment Other than Aerosol N.T.S. 3 Sandy Clay Loam, Clay Loam, Silty Clay Loam PR, BK, GR 2. 3 41-60 0.35 0.50 0.50 v 0.60 0.80 -- 1 Sandy Clay Loam, Clay Learn, Silty Gley Loam 0 1 Massive 61-75 0.30 0.40 0,40 0.50 0.50 Vault Privy 50 102 25 15 10 10 25 10 -- 4 Sandy Cby, CLAY, $lily PR, 8K, 2, 3 76-80 0.20 0.30 0.30 0.30 0.30 Slit Trench Latrine, Pit Privy 4 100 502 25 NIA 25 25 100 25 N/A Cloy GPI Sandy Clay, Clay, Silty Clay K. 1 MassiveTreatment B1 120 0.15 0,20 0.20 0.20 0.20 System Not Relying on STA for and Utilizing Aerosol 1003 102 50 125 10 0 253 10 10 BED OF 1 1/2" SCREENED FILTER FABRIC 0 ROCK, 12" THICK Methods TOPSOIL 5 Sell Types 2-4A Platy 1, 2,3 121+ 0.10 0.15 0.15 0.15 0.15 SLOPE TO SLOPE TO 12" MIN 4 DRAIN DRAIN 4 NOTE: Shaded areas require system design by a professional engineer. NOTE; The minimum distances shown above must be ma reamed between the OWTS components end the features descried. Where soil, geological or Other greater distanoeS may be required by the beat board of health or by the Water Quality Control Ccrnmissior pursuant to section 25-8-206, C.R.S. and applicable or upgrading of existing OWTS where the size of lot precludes adherence to these distances, a repaired OIArrS shall not be loser to setback features than the conditions warrant, regulations. For repair existing OWTS, as � \ \ \ \ \ N. \ \ \ 1 EXISTING GROUND 1 /////�///�///�/� //// / / / \. \X\X\ /\ X\ /\ A • • •• • • \ \ •\ \\/\\,\\/�\���\�/\\\\ 1 Treatment levels are defined in Table 6-3. 2 Unlined sand fliers in these soil types shall provide pathogen removal. design shat! conform to section 11.C.2.c, Unlined Sand Filters reviewed and approved by the local public health agency. Components that are not watertight should not extend into areas of the root system of nearby trees_ 1 Includes infiltration permitted as wells by the Division of Water Resources. SURFACE �%/��, , •Higher long-term acceptance rates for Treatment Level 3N may he allowed For OWTS required to have a discharge permit. if the capability of the design to achieve a higher galleries 2 Crossings or encroachments may be permitted at the points as noted shove provided that the waterer wastewater conveyance pipe is enraged for the minimum setback • • ® loo-term acceptance rate can be substantiated. distance on each side of the crossing. A length of pipe shall be used with a minimum Schedule 40 rating of sufficient diameter to easily slide over and completely encase the conveyance. Rigid s of at ur ed n a t ion to ds of the pipe. A of sufficient le 40 rating must be glued osG e nbottom rthe iGOnveyan�nyipe size to \ 3 ' :>. ; ,..: ,.. .�'�\ �\ �\ �\ �\ �\ of the enc seamen plpent accommodate pipe abaci be ddlledsin the lot west section of the rigid Gap that heats anhthe nThe areore which ch,he pipe 0 N KARL HANLON /10,17V.I.,'eGOv�'HIGH COUNTRY ENGINEERING, INC. I%) xGARFIELD COUNTY, COLORADO 01 n 271 WILLOW LANE H CE 1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 81601 N cn z ONSITE WASTEWATER 1ti cli c- �u PHONE (970) 945.8676 -FAX (970) 945.2555 p TREATMENT SYSTEM �iNEER`' WWW.HCENG.COM passes through the end cepa shall be seated with an approved underground sealant compatible with the piping used. 1//////�' / / / / / / \'/\\ \.\��\�/�/�/� •\ /\ \ '. .. 6 / // // // // // // /\\�\��\���� :... .\fir\�/ <.......::: .. � `° . � ` :: � 3 Add eight feet additional distance For each 100 gallons per day of design flows between 1,000 and 2.000 gallons per day, unless it can be demonstrated engineeror geologist by a hydrologic analysis or the use of a barrier, eanSi8t+ng of a minimum 30 mit PVC liner or equivalent, that contamination will be minimized. Treatment Level 3N and the local public heath agency Fres a maintensrce oversight program in accordance with section 14.6. of this regulatlen, the distance by a professional if effluent meets addition is not 3'MIN.� 3' SAND FILL-PER GARFIELD Flows equal to or greater than 2,000 gallons per day must be hydrological analyzed for few, velocity, hydraulic head, and other pertinent characteristics as means distances required to minimize contamination as part ofthe Division site application process. required. of estimating DISTRIBUTION LATERALS � COUNTY REGULATIONS 3' MIN FROM INFILTRATIVE SURFACE TO GROUNDWATER SECTION A-A 4 blew installations for pit privy and slit trenches not allowed. N.T.S. STATE SOIL TREATMENT AREA GUIDELINES (LTA) STATE SETBACK GUIDELINES NOTES: 1. CONCRETE TANK MUST MEET ASTM C1227-12 STANDARDS. 2. ADDITION OF A CHARCOAL FILTER VENT LINE FROM TANK CHAMBERS WILL PROLONG THE LIFE OF THE TANK CONCRETE, NOT REQUIRED. 2000 Gallon Top Seam Item # Two Compartment 2000T-2CP-HH with High Head Pump 182" REMOVABLE PVC CAP INSTALL MARKER IF CAP IS TO BE BURIED. nFSIC,N NOTES"i C,serA,xsea FINISH GRADE Design• 0per performance test per ASTIR I • 'II DIA L� FE �f • Top surface arse 87.75 ft' ��. '; Xf J fc 28 days; concrete 6,000 PSI... Min. Installation �� REMOVABLE CAP I L rD WITH I T f l LID 0. ' o °�. o�.o•0• o° o. Tank II �' oq . a to be set on 5" min. sand bed or poo gravel • Tank to be backfilled uniformly an all TANK s ria Ip Y " 4 - 1/2 VENT HOLES +� sides in lifts less than 24" and �, �• 1 .5I' PVCSLIP MALE mechanically compacted • Excavated material may be used for backfill. provided large stones are Top 24• „ PIPE THREAD HREADbackfill• _ ..... removed View FINAL • Excavation should be dewatered and tank filled with water prior to being put ,,, In service for Installation with waterBea IAril9efc - Min. JHeight SOLID PIPE \/ \fir _ I - I �y C I- I GRADE I I I I I - ADAPTOR - - _�+ ti�TA� '�I table less than 2' below grade ' $adarui6er REBID ' q Dimmed �j/\\\\ 4� L -I ; I- i� ,- . Meets C1544-08 far resilient connectors . Inlet and Outlet identified above '-I ! � �Y-' � / \�\\/\\/ /-\/ I-I I I I I i ` 1,51 DIA BALL pipe Delivered complete with internal piping -) -� /. / / \\\' I I M. I 4" COUPLING4" RISER • Secondary safety screen available with ,� I4LE PVC riser rN,• • U .�' /\//\ \ _� -I I 11 _ 111 COUPLING\/// -IN 1' �� Y� r�� I \ \ Nil/ 1 1/2" SCREENED ROCK 4" 45° SWEEP BEND 7 �\ \ �+ 4" SEWER LINE ALLOWABLE BURY (Based on water Table) e'' 56" '; ' 3' jj j • - � \ 1 1/2" PERFORATED PVC rte {') ea. -. rktales y - r I A PVC L ONG T - ALLOWABLE BLL /,\ • ' SAND .4..1., SWEEP L� WATER TABLE EARTH o' - o' 3' - o- \/ 1 4" PERFORATED PIPE FLOW ///z//\ AIP. { r.-0" 3'-0' \\/ /\\//\\/\\ 15r \, \ \� //� //� \ //� //� T CiMilb 1-‘: :OM.+lig 2• - 0" 4` - O" Pump: Section /� /� 41117 milF - 3' - 0- 4' - 0- a Lowers TSS and improves quaillytofield � �IM14rR ■���--- g. Vir - - im. wan { IN-SITU OIL DRY �' - o• • Eath. system b mire* en CONCRETE BLOCK1( Ar . �� • Complete !ma'am talking. mak a a a a i 4" X 4" X 4" �� PVC WYE mounting and aterkup procedures) 'lents coniracfa available for maintenance* • Complete wormy Digging Specs Invert Dimensions Net Capacity Net Weight CLEAN OUT ASSEMBLY 15' Long x 8' Wide Inlet Outlet Length Width Min. Height Inlet Side I Outlet Totd Lid Tank Total x58' below inlet 56' 73" ler 78' 92" 1559 sol 507 gal 2088 gal 5420 lbs 15530 lbs 21150 be IN SP E C T I O \ WELL DETAIL FLU H I DETAIL SEWER CLEAN OUT DETAIL W ra 29395 GIand.317 Wastewater �1�3t�-67Br1 12.0.BacN.T.S. 1171VALLEY •• Systernet FEIC (719) 395-3727 Btlene Villa' CO 81211 h�T TO SCALE N.T.S. •Service ��Emil: �al Li�_�yj� EXISTING 2, 000 GALLON TWO+® Rp,DO i ?' _ ori 29975 ' i �; COMPARTMENT SEPTIC TANK ,�� '1C', '�+'���j WITH HIGH HEAD DOSING PUMP '�°�'a�`r