HomeMy WebLinkAboutApplicationGarfield County
Community Development Department
0
0 10 108 8'h Street, Suite 401
Glenwood Springs, CO 81601
070194S-8212
uiww..aWWe.r �ner.mm
TYPE OF CONSTRUCTION
❑ Commercial/Multi-Family
❑ Manufactured Home (Single or Multi -Level) _
�] Residential (SF, Duplex or Townhome)
INVOLVED PARTIES
BUILDING PERMIT
APPLICATION
0 Demolition
❑ Reroof
Property Owner: 1wthI Q eTro, ! C Phone: ( )
Mailing Address: 1906 SO H OCEAN BLVD. PALM BEACH, FL 33480
Email Address:
contractor: GIARD HOMES INC.
Phone: ((970)p25-2347
H1431Mailing Address:
AIRPORT RD., RIFLE CO 81650
Email Address: roger.giard@giardhomes.com
Architect: EGGERS ARCHITECTURE INC.phone: ((970) T24-3411
Mailing Address: PO BOX 798, KREMMLING CO 80459
Email Address:
Engineer: KRM CONSULTANTS Phone: ({970) p49-9391
Mailing Address: PO BOX 4572, VAIL CO 81658
Email Address:
Manufactured Home Installer: Phone: ( )
Mailing Address:
Email Address:
1. PROJECT DETAILS
i Describe Work: NEW, SINGLE FAMILY, SINGLE LEVEL, LOG HOME
I ON CRAWLSPACE FOUNDATION
Job Address:
v • •
Assessor's Parcel Number:
1877-254-00-014
Sub.
Owner's Valuation of Work: $211,906.00
Lot
1329 3 Ci zs2) g;f le
Block.
Property Size (Sq. Ft. or Acres):
Sq. Ft. of Buliding: 1985 Height: 20' _ N of Floors:1
Class of Work: 1J New [ Alteration j] Addition DRepair ❑ Move/Relocation
r Garage: Attached l..
LI Detached
PROJECT DETAIt5 CONTINUED
7YPe o(Heit: Natural Gas 'i-
Propane
priveway
p07ia
Auth ri .Building
This application fora
Permlt must be signed by the Owner of the property, described above.
or an authorised agent. if the signature below isnot that of the Owner, a separate letter of authority, signed by
the Owner, must be provided with this Application.
to al ACces . A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
1herP resits. Multiple separate permits maybe required: (1) State Electrkal Permit, {2} County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permlt A Building Permit becomes null and void if the work authorised is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days alter commencement.
CERTIFICATION -----
I hereby certify that I have read this Application and that the information contained above is true and correct. 1
understand that the Building Division accepts the Application, along with the plans and specifications and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of this Application, a Building Permit will he issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals agents wid ll
the Building Division. In consideration of the Issuance of the Building Permit, I agree that I and my
comply with provisions of any federal, state or local law regulating the work and the Garfield County Building
Code, OWTS regulations and applicable land use regulations (County Regulation(s)). i acknowledge that the
Building Permit may be suspended or revoked, upon notice from the County, If the location, construction or use
of the structure(s) and facllity(les), described above, are not in compliance with County Regulation(s) or any
other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. 1
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping
construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other
applicable law. Review of this Application, including submittals, and inspections of the work by the Building
Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions or
discrepancies_ As the Owner, I acknowledge that responsibikity for compliancecpwitwitht fedmeri n 1. my architect localtate and laws
and County Regulations rest with me and my authorized agents, g
designer, engineer and/ or builder. _�� 1---
hereby acknowledge that I have read understand the Notice and Certification above, as well as, have
owle e
provided the required information whi r, ct and accurate to the best of myn
1
0 Community
_i❑ Electric Dottier
n Permit e•
V brt,d /( j +""x
Property Owner Print and Sign
OFFICIAL USE ONLY
Date
Special Conditions:
Adjusted Valuation:
2i-rj101-oo
Total Fees:
tb21W.01
5 tbacks:
rig=25, °icier• to
Ian Check Fee:
11015.4+
Fees Paid:
1S3•[ov
Balance Due:
1)4-VU.31
OCC Group: 1 g
Manu home Fee:
BP No:
4th
Raadt� fico,
North of • tr at
Const Type: I INC-,
BUILDING / PLANNING DIVISION : r Signed Approve
PD slo53 45,7-1 GC,/ \ I�
Misc Fees' 115re.o0
OWTS No:
4- D
Zoning: n
(0L3 ?A +7
Date
Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.Rarfield-countv.com
SINGLE FAMILY OR DUPLEX
BUILDING PERMIT
APPLICATION CHECKLIST
SINGLE FAMILY OR DUPLEX BUILDING PERMIT APPLICATION CHECKLIST
In order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application.
• Parcel number obtained from the County Assessor's Office.
• Job address (assigned physical address)
• Legal Description: block, lot, tract, subdivision, filing, or section, township and range.
• Owner's name, mailing address, phone, fax or cell.
• Contactors name, mailing address, phone, fax, or cell.
• Architect and/or Engineer's name, mailing address, phone, fax or cell.
• Building size, height, number of stories and lot size.
• Use of building (Residential).
• Class of Work (New, Addition, Alteration, Repair, Demo, Move/ Relocation).
• Detailed description of work.
• Type of heating (natural gas, propane, electric, other).
• Sewer system (Community or OWTS), also see other items below.
• Garage (Attached or Detached).
• Driveway permit (please see other items below).
• Valuation (labor and materials), see attached worksheet.
OTHER ITEMS:
• if you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. Required to submit building permit application.
• OWTS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board.
• At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached at 970-625-8601.
• If you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
• If you belong to a Homeowners Association (HOA) It is your responsibility to obtain written
approval, if required.
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Additional Dwelling Units may require Administrative Review.
• Minimum dwelling dimension is 20 ft. wide x 20 ft. long.
• A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups,
unless the homeowner Is performing the work.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible and to scale. All plans will be checked at the counter for completeness. If any of the
required information is missing, the building permit application cannot be accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain and easements.
• Provide setback distances from boundaries, buildings, septic, well and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures. Include sheds, barns, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields and other systems (if applicable).
• Retaining walls (engineer stamped detail required for walls over 4 ft., measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Minimum of four (4) elevations (N,S,E,W). Indicate height of building measured from existing
grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat
roof.
• Floor plans for each level, including dimensions and scale noted.
• Clearly label each room or space (bedroom, bath, kitchen, closet, etc).
• Show the location of the mechanical equipment.
• Building cross sections with construction details.
• Window sizes, types and operation noted on the floor plans or elevations.
• Specify roof slope/pitch, roof covering and siding materials.
• Stair and guard details specifying rise, run, height and spacing.
• Attic, roof and crawlspace ventilation details. Indicate size and location of ventilation openings.
• Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces.
• Provide stove and fireplace make, model, EPA or Colorado Phase 11 Certification. Masonry
fireplaces shall be designed to the International Residential Code (IRC) requirements.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement and referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre -manufactured structures require the engineers stamp, signature and date.
• Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: If any required information is missing, delays in issuing the permit are to be expected. If
determined by the Building Official that additional information is necessary to review the application
andtor plans for compliance, the apnli
provided. Work may not proceed without then ube pl of ad on it.
hold until the required information is
e
The Building Division will collect a plate Review fee at time of app'
Well as any Road Impact fees will be collected when the permit islissued on submittal. The permit fee, as
tohactt as the prep esen ative. signed
by the owner or by person having written authority from the owner
Building cannot be occupied until a Certificate of Occu ancs issued. Using the building without a
CO will be considered an illegal occupancy and ma be grounds (CO)for vacating the premises. (f=inal/CO
inspection
requirements will be attached 10 your approved field set of plans.)
I hereby acknowledge I have read, and
checklist.
tand and will abide by the requirements of this
mdda
roperty Owner Print and Sign
5/16117
Date
1 +S . Garfield Caruso.
Building/ Zoning Plan review Checklist
Permit Number: C'O67- f 7-'g75'T
SePT Ov-i7-g7<•+o
Building
Engineered Foundation
�Driveway Permit
X Surveyed Site Plan
Septic Permit and Setbacks
Grade/ Topography 30%
Attach Residential Plan Review List
N/A Subdivision Plat Notes
7
NA _ Fire Department Review
Valuation Determination/ Fees
Red Line Plans/ Stamps/ Sticker
Attach Conditions
Application Signed
Plan Reviewer to Sign Application
Parcel/ Schedule No.
40# Snowload Letter — Manu. Homes
Soils Report
21045 x 4374. 6,6 = 9, 1521721.
(975 54 9�32.M = 211 (ia9.
2)045 x 31e .00 : Seel €.10.
26,5 16.00 =' 4770.
150 2./2.Do=? 1)42)0.
IOTA(.- = 421-0701.
Planning/ Zoning
/ Property Line Setbacks
WA
N/A
30 ft. Stream Setbacks
Flood Plain
Building Height
Zoning Sign -Off
Road Impact Fees
/ Grade/ Topography 40%
Planning Issues
N/A Subdivision Plat
General Comments:
Ofetiol soca
COV r4 Poircln
4t4( '. 1=64fTb
21d,e-i5
(i?5
20.45
7-105
150
Ram UMC C,t = $115.14s.