HomeMy WebLinkAboutApplication- PermitNo. 5960
GA RETELL) COUNTY
BUILDING, SANTA TIQN uad _MANNING DEPARTMENT
109 8th Street Suite 303
Glenwood Springs, Colorado $1601
(303) 945-8212
9433 County Road 335, New Castle
Joh Address
Nature of Work Building Permit
ITSC ofBuildinp Chlorination Building for Wastpwatpr ni crhargp
ownerR.B. Water & Sewer
Cor[raetor
Mesa Structures, In.c
Amount of Permit $ 421 •80 Datc July 2. 1 996
Permit: 287.25
Plan : 134.55
Paid $134.55
S. Archuleta
Clerk
BUILDING PERMIT APPLICATION
GARFIELD COUNTY, COLORADO
Applicant to complete numbered spaces only. PERMIT NO. 6-9610 PARCEUSCHED NO.
JOB ADDRESS 9 3 3 e..4 33S /(/ PaJ &
1
LEGAL
dESCR.
LOT NO, prt 7 e-rY.
//
BLOCK
SUBDIVISION p ve, y.�
t
2
OWNER
R [VAT -Et d g
y� r
DRi 55 r� o, g a !
giW61 Ce et6o�
PH. f C
WK. PH. y-24 z1
3
CONTRACTOR T
ADDRESS !' (
PH.
LICENSE NO.
4
ARCHITECT OR DESIGNER S cpiA
ADDRESS
PH,
LICENSE NO,
5
ENGINEER .5"d -A
ADDRESS
PH.
LICENSE NO.
6
S.F OF BUILDING 2 "7
S.F OF LOT / A�' p
J(�
HEIGHT G z f
NO. OF FLOORS
7
USE OF BUILDING P /LCCflP_ 1, t,Arie/4 e9 ,
! ih
y/6 ATT�t
8
CLASS OF WORK 'NEW o ADDITfON D ALTERATION 0 REPAIR o MOVE a REMOVE
9
DESCRIBE WORK: 7 h/t C) t/ J4 A i 111 N _r! le -pi !tel 62 f` l J e Le/d 5% W OP',
10
GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE
DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT >2e6 SITE PLAN JL I.is
11
VALUATION OF WORK: $ `) /7I j 0 0 ADJUSTED VALE
j4"
PLAN CHECK FEE #/,3 �s
PERMIT FEE a? g 7, s
-
SPECIAL CONDITIONS:
SCHOOL IMPACT FEE
NO. OF BUILDINGS ON
PARCEL
USE OF BUILDINGS NOW ON
PARCEL
TOTAL FEE XpS��7} ,, 0O
OCC. GR.L/ l
CONST. TYPE iV
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL PLUMBING,
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED
NOT COMMENCED WITHIN 180 DAYS, OR 1F CONSTRUCTION OR WORK 1S SUSPENDED
OR ABANDONED FOR A PERIOD OF t80 DAYS AT ANY TIME AFTER
COMMENCED.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND
THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME
AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE
LOCAL LAW REGULATING 4, , ..TRUCTION OR THE PERFORMANCE
CONST' T •N.
;-Ag/ _ AI�� ';: (Date)
WATER SUPPLY
DATE PERMIT ISSUED 7- Z_ -9j
HEATING,
SPECIAL APPROVALS
REQUIRED
RECEIVED
NOT REQUIRED
IS
ZONING
WORK I5
HEALTH DEPT.
KNOW
FIRE DEPT,
TO GIVE
SOIL REPORT
OR
OF
SETBACKS
FLOOD HAZARD
Signature of • ..r, eG
`�'1�4 .�f
Building Dopa `entApprovah
tractor or authorized agen .,:vi , :ad - •. • n
,
- rstood notice
above.
/
MANUF. HOME
to d Planning Dep. mentApprovalltddatte�
OTHER
I
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR ANO/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30,28.201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THEISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT 'ESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE
GARFIELD COUNTY
Building and Planning
MEMORANDUM
To: Steve Boat
From: Don Owens
Date: August 29, 1995
Subject: R.B. Waste Water Treatment Facility.
In my preliminary review of the plans submitted in application for a permit 1
did not see many items that concerned me greatly regarding the building
design or construction of the buildings, however other information will be
required in order to continue the plan review.
will need some additional information from you regarding the facility, as
follows:
1. A more complete site plan is need to determine the distances to
property lines, recreation areas, public ways and residential areas.
2. A more complete listing of chemicals to be used in the operation of
the plant and the quantities in use and in storage. 1t does not indicate
on the plan the number of cylinders (150#, 810 cu. ft.) of chlorine in
use or in storage. Will other chemicals such as a filter aid polymer
and alum, calcium hypochlorite, sulfur dioxide gas or other be used in
the operation? If yes, in what quantity and form?
3. Plans for the facility are required to be wet stamped and signed by the
engineer.
109 8th Street, Suite 303
1
945-8212/625-5571/285-7972
Glenwood Springs, Colorado 81601
Dori The information below only needs to be provided if the
information requested in the memo (RBwaswal.95) to Steve Boat
indicates that the amount of hazardous materials exceed the exempt
amounts indicated in U.B.C. Tables 9-A and 9-B. I am sure that they
will be Tess considering the requirements if they are in excess of these
amounts.
If the amounts are in excess of the exempt amounts then the local fire
district should have a copy of the information below because they may
have adopted the Uniform Fire Code and want to enforce the
hazardous materials provisions in Article 80 of the U.F.G. If the
amounts are less than it may be recommended that they check with the
fire district for any other special provisions. If you have questions on
this, give me a call. Art y
RB WASTE WATER TREATMENT FACILITY
ADDITIONAL PLAN REVIEW NOTES
Many of these comments reference provisions of the U.F,C. (Uniform Fire
Code) as indicated in U.B.C. (Uniform Building Code) Section 901 (a)
General. The notes regarding items that are requirements of the U.B.C. or,
the U.B.C. and the U.F.C. are determined to be requirements of codes
adopted by Garfield County. Some, such as U.B.C. Section 901 (f)
Requirement for Report, (No. t18 of this document) are discretionary on the
part of the building official. Notes regarding items that are only contained in
the U.F.C_ are intended to provide information from nationally recognized
standards to the owner, designer, contractor and fire officials having
jurisdiction. Enforcement of items contained only in the U.F.C. is at the
discretion and direction of the Fire Protection District having jurisdiction.
SPECIFIC NOTES AND COMMENTS ON ENGINEERING CONTROLS
AND DETAILED REQUIREMENTS:
1.1 Group I.1, Division 2 and/or 7 Occupancies are required to be
protected by a complete automatic fire sprinkler system: U.B.G.
1
Section 3802 (f).
1.2 It does not appear that the provisions of the U.F.C. Article 80 have
been considered in the plans and design submitted in application for a
permit. The occupancy has Chlorine in amounts which exceed the
exempt amounts provided for in the 1988 or 1994 U.B.C. There are
possibly quantities of other chemicals that also exceed these exempt
amounts. The plans submitted are general in nature and do not
adequately address the operational, control and safety aspects of this
facility. More detailed information is to be provided for both building
and fire officials.
1.3 The U.F.C., Section 80.104 (e); requires signs posted at entrances to
locations where hazardous materials are stored.
1.4 U.F.C., Section 80.106 and 10.301 (b); requires personnel training for
mitigating the impact of leaks and spills. The Carbondale Fire
Department may require that some of their members be trained as
well in the application of chlorine leak kits ( which are not identified in
this plan) as well as staff responsible for the operation of the plant.
1.5 U.F.C., Section 80.301 (s) and 80.303.(a) 7; Emergency power is
required to be provided for all required electrical equipment within
areas in which toxic gases are stored or used. Stand by power is also
required. Plans appear to provide an emergency generator for the
Control Building but do not appear to provide this service in the
Chlorine Building. More detailed information may be requested by fire
officials.
1.6 U.F.C., Section 80.301 (u) and (v); Requires a local fire alarm manual
pull station or approved (by fire department) emergency signal device,
The alarm is to have local warning and is required to be supervised.
Supervision is to be by an approved (by the fire department) central,
proprietary or remote station service or shall initiate an audible and
visual signal at a constantly attended on site station.
1.7 U.F.C., Section 80.303 (a) 6 D; Requires the installation of a treatment
system for the chlorine installation. Proximity of residential areas,
2
public ways, work areas and recreation areas (river and golf course)
need to be taken into consideration. The fire district may want to
consider U.F.C., Section 10.301 (b) Special Hazards, in consideration
of this as a life -safety system.
1.8 Gas detection is not required for chlorine systems, however, if
provided it must conform to U.F.C. Section 80.303 (a) 9. Signals as
well as electrical supervision information (U.F.C., Section 10.301 (b))
are to be transmitted to the supervising station.
1.9 An approved, smoke -detection system is required to be provided in
the storage area containing the chlorine. The system is to be
supervised as described above. Electrical supervision is also
required under U.F.C., Section 80.303 (a) 10.
1.10 U.F.C. Section 80.303 (c) 5: Two self contained breathing apparatus
are required to be provided to serve this area. A list of emergency
equipment including its location should be provided for approval by the
fire department..
1.11 if a Class 3 oxidizer (sodium hypochlorite) is to be used in this
building, the location must be defined and if storage exceeds 20 lbs. ,
secondary containment will be required. The storage of a Class 3
oxidizer in the filter room requires that they be placed in an approved
hazardous materials storage cabinet. U.F.C., Section 80.306 (a) 13.
1.12 U.F.C., Section 80.401 (k) 4: Pressure relief devices which may emit
either highly toxic or corrosive materials from equipment is required to
vent to an exhaust scrubber or treatment system for processing
vented vapors or gases. This requirement is because chlorine is a
corrosive not because it is highly toxic, it is toxic.
1.13 U.F.C., Section 80.401 (c) 2 and 80.401 (c) 3D: Systems are to be
equipped with emergency shut of devices. Plans do not indicate this,
as far as I have been able to determine.
1.14 U.F.C., Section 80.401 (c) 3C: Excess flow control is required for
piping systems. Plans do not indicate this, as far as I have been able
3
to determine.
1.15 U.F.C., Section 74.107 (a): The plan indicates that the cylinders in
storage are secured with "approved safety brackets", however there is
no indication that the cylinder in use has been secured for seismic
restraint. Also refer to U.B.C. Table No. 23-P II.
1.16 U.B.C., Section 3320: The filter area of the building is required to
have two exits. The single exit from the chlorine room complies.
1.17 U.F.C., Section Z302, Technical Assistance: "If technical expertise is
unavailable within the department to determine the acceptance of
technologies, processes, products, facilities, materials and used
attending the design, operation or use of the building or premises
subject to the inspection of the department, the chief may require the
owner or the person in possession or control of the building or
premises to provide, without charge to the department, a technical
opinion and report. The opinion and report shall be prepared by a
qualified engineer, specialist, laboratory or fire -safety specialty
organization acceptable to the chief and the owner and shall analyze
the fire -safety properties of the design, operation or use of the building
or premises and the facilities and appurtenances situated thereon, to
recommend the necessary changes."
1.18 U.B.C. Section 901 (f) Requirement for Report, provides that the
"building official may require a technical opinion and report to identify
and develop methods of protection from the hazards presented by the
hazardous material. The opinion and report shall be prepared by a
qualified person, firm or corporation approved by the building official
and shall be provided without charge to the enforcing agency.
The report may include, but is not limited to, the preparation of a
hazardous material management plan (HMMP); chemical analysis;
recommendations for methods of isolation, separation, containment or
protection of hazardous materials or processes, including appropriate
engineering controls to be applied; the extent of changes in the
4
hazardous behavior to be anticipated under conditions of exposure to
fire or from hazard control procedures; and the limitations or
conditions of use necessary to achieve and maintain control of
hazardous materials or operations. The report shall be entered into
the files of the code enforcement agencies."
By: Don Owens, Chief Building Official. Date: ugust 29, 1995
R w6 aswa2.95 CR'" ,7gT�
161 1.'41rJ6,;AA id a• IA L.1 riLiLI ,k iW d aa,+;: Ju•14•r'i 1 �r;s'a kl�aL✓`
THS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
FIELD COUNTY, COLORADO
Date Issued/.Zoned Area Permit No. 5'0
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of the
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction of the above described structure, the permit may then be revoked by notice
fro C n ildi I s ector and MM I,1E L BECOME NULL AND VOID,
Use ri L, I
3 3
Address or Legal Descriptio
Owner *
Contractor
3
/7)2z
4
Setbacks
Front
Side
Side
Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 10 9 8th Street, County Courthouse, Glenwood Springs, Colo.
APPROWED DO NOT DESTROY THIS CARD
Date By 41
INSPECTION RECORD
Zoning
Roof Covering
Footing 74z4iii,Foundatib
APlumbing-Underground
Electric -Final (by STATE inspector)
f�/
i ;
_
Gas Piping
Heating Ventilation
Frame
Insulation
1
Plumbing -R ough
Drywall
Electric -Rough
(by STATE inspector)
Final 7 -,2,/{_,
7
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING —
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 10 9 8th Street, County Courthouse, Glenwood Springs, Colo.
APPROWED DO NOT DESTROY THIS CARD
Date By 41