Loading...
HomeMy WebLinkAboutApplication- Permitlob Address No. 5904 GARIIELD COUNTY WIELDING, SA NITATIONand PLANNING DEPARTMENT 109 ROI Strccl Suite 103 Glenwood Springs, Colorado 81601 (303) 945-8212 0739 Huebinger Drive, Westbank Mesa, Lot 28, Glenwood Springs Nalun: ofWork Building Permit Uscofl3uilding Single Family Dwelling w/Triple Garage Owner Michael Metheny Contractor Owner AmountorPermit$ 2,255.96 D:dc_ May 21y_1996 Permit: 1,367.25 Plan . 888.71 Paid $888.71 5-7-96 S. Archuleta Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only. PERMIT NO. g-aY PARCELJSCHED NO. f JOS ADDRESS p I•/ 3Q r !f 1 LEGAL DESOR. LOT NO. BLOCK re�—��-T SUED/VISION r� � f �� i / rlr?, 41, 4/ 2 /�� OWNER ! e%�� ! ADDRESS I d l� k Cf Ai. (f (Ji�lf4f �l/C PH. 9 0 $3/ / r/ air Up/ WK. PH- 377 .. 34,% 3 CONTRACTOR, .. / der s°!!{iiJj ADDRESS I ADDRESS /r PH PH. / 1 LICENSE NO, LICENSE NO, 4 ARCHITECT OR DESIGNER / ( 5 ENGINEER ADDRESS PH. LICENSE NO. e S.F OF BUILDIN zica S.F OF LOT. 4.2141 N / HEIGHT4 z j NO. OF FLOORS' �. 7 USE OF BUILDING 5 .-. 1/e. /47,4,1 ! , 45,40(...{ 8 CLASS Or WORK: EINEW? o ADDITIONJ❑ ALTERATION a REPAIR o MOVE o REMOVE 9 DESCRIBE WORK: C -C, 5 r(,t.if di 4Vk) iv e -1;i MF 'ar- ///e//1e/iS°/ GARAGE SINGLE DOUBLE Je CARPCR7SINGLE DISPOSAL PERMIT / �Q DOUBLE\�9Onr-774-- SITE PLAN DRIVEWAY PERMIT ON SITE SEWAGE 1 VALUATIou or WORK: $ "SV •L 1Tr) ADJUSTED VA..$ PLAN CHECK FEE g O F, 7 / PERMIT y 71.. SPECIAL CONDITIONS: _ )q5yO.00 } ,pDV " Xf7,ZS SC}IDOL IMPACT FEE y%��' NO.OF BUILDNGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL/ TOTAL FEfEE 3UJ; q 4 OCC, GR..R3 �% f CONST. TYPE r h( NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING, THIS PERMIT BEGONE, NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER COMMENCED, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE LOCAL LAW REGULATING CONSTRUCTION OR THS PERFORMANCE CONSTRE3CTIO ! `% 7 , ' ' 7 fr . ''" -(ir � WATER SUPPLY DATE PERMIT ISSUED 5'a/-96. SPECIAL APPROVALS REQUIRED RPCErvEa NOT REQUIRED IS TONING �' Y// WORK IS WEALTH DEPT. KNOW FIRE DEPT. TO GIVE SOIL REPORT t----- OR OF SETBACKS FLOOD HAZARD I Signature aF OwnBr,SLontraotor or Buthorized age On. z: �� �ers[ood • otice d j AP /Ter !Dove. MANUF. HOME Buis epartmentApprovafd PlanningDep.'meat: OTHER � I r+ ck pa 1 AGREEMENT 4yt u. PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST_ Garform,003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL�-6 �/z GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1 1. Is a site plan included that addition to property lines, easements? Yes i4 No indicates the distance of the proposed building or other buildings, set back easements and utility („ Not necessaryfor this project (2) 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes No ,,, Not necessary for this project (2) 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes k No n) Not necessary for this project (2) 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes X No (1) Not necessary for this project (2) 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No (1) Not necessary for this project / (2) 6. Do the plans indicate the size an location of ventilation openings for the attic, roof joist spaces and soffits? Yes )X No (1) Not necessary for this project (2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County) floor loads and wind loads? Yes X No (1) Not necessary for this project (2) 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes ,.k No (1) Not necessary for this project (2) 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X No (1) Not necessary for this project (2) 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes . No (1) Not necessary for this project 2 (2) 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes k` No (1) Not necessary for this project (2) ,, 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No (1) Not necessary for this project A (2) 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No (1) Not necessary for this project \ (2) 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes ; No (1) Not necessary for this project (2) 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ,(" No (1) Not necessary for this project (2) 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes __ No (1) Not necessary for this project (2) 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yeses- No (1) Not necessary for this project (2) 18 Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from that association, if required by that association, prior to submitting an application for a building permit? Yes No (1) Not necessary for this project (2) 19. Will this be the only residential structure on the parcel? Yes No If No -Explain 3 20, Have two (2) complete sets of constructions drawings been submitted with the application? Yes . No (1) Not necessary for this project (2) 21. Is this an application for the placement of a manufactured home? Yes No T _ If yes, have you specified the size of the unit (min. 20ft x 20ft); live roof load (min.40#); wind design (min. wind speed of 80 mph & 15 Ib, wind load); foundation design; method of anchoring? Yes No (1) Not necessary for this project (z) 22. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No (3) 23. Does the plan accurately indicate what you intend to construct and what will receive a final.irjspection by the Garfield Building Department? Yes ..;: No (3) 7-i-- 24. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes No (3) 25. Do you understand that the Building Department will collect a "Plan Review' fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permit? Yes _ . No (3) 26. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before . Failure to give 24 hour notice for inspections will delay your inspection one (1) day. Yes '\" No 27. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certifi9ate of Occupancy and occupancy of the building? Yes No (3) 4 28. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes".„ h Yes _ba No (3) I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. signature e� Phone: 37y -;j034' (days); 963 ` /5 (evenings) 7G Sy 3911 Project Name: 71'x, 7%kf igovi E" f'st:✓ka) IRe54kvicc. Project Address: 0 7,3"7 1/,/ ..(,;n L; ); �> _ 2y,, 1,/czo9 ,3)1^..:acs / Notes: (1) If you haw answered NO on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. (3) C. Delay in proceeding with construction. If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Ordef' being issued or a "Certificate of Occupancy' not being issued. PerApp02.95 Effective August 15, 1995 5 (� tr.; nl -^.I COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT AND CORRECTION NOTICE Permite# 6- 's7 9 yr a / Contractor/H eowner Address 7 Date received '` S I, -.,Travel Time i Phone # Date Inspected 1 C' Inspection Time Time Lapse Arrival Tine TYPE INSP TION Power Connected Yes No ❑ -Res. Comm❑ Rough -in ❑ Fina Partial ❑ Reins ❑ Temp Meter ❑ Temp Heat ❑ Mobile Home ❑ Service ❑ Other (please specify) Service: - Wiring Method -.Jill —(a �, Type 1 0 or 3 O Classified area Yes _ No ze �.(j GFCI Yes iNo Overhead Finished basm't Yes No Underground ✓ Sub panels Yes No Type Grnd - — GC Elec Range Yes /'--No Size Grnd Conductor' 4 Elec Dryer Yes No _ - Date Meter. Released '>" y -lie, Elec Wtr Heater Yes No ActiorV; AtCepte�lj / / Rejected Remarks REINSPECTION FEE REQUIRED. A reinspection will not be performed until the reinspection fee is received. COMMENTS - Inspector Page 1 of 1 I i ... .a „J ..l ...a...J ..i i/ -. .�✓ i y l.:ii t i oA�4D IS ;COSTED ON R��IE SOD 24 HOURS NOTICE REQUIRED FOR INSPECTIONS d -W BUILDING PERMIT G FIELD COUNTY, COLORADO Date Issue .. ".f." : `:.Zoned Area Permit No AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector,a IM DIATE BECOME NUL AND'VOID Use r l ��� i 4.�� �� eE 1 Addresn Lga escrip ioF Owner'//j 4 =4*- Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. OVED )DO NOT DESTROY THIS CARD 6 By+ lig t _F£1 .. INSPECTION RECORD Footing ,, _ c ,,._ Foundation Underground Plumbing / _ ?? _ ; - ;__,±_.- __,` - Insulation y _„ -_ , Rough Plumbing — _ _ `(G- (c/ ;7: Drywall 5' / .: ie _ Chimney & Vent he Electric Final (by State Inspector)T Gas Piping —_ C_ -, / `-` 7 i �' '- r 1 :',/--__-Final .7C, ' /— 5 %� l2l`f/a( Electric Rough (By State Inspector)4-y ='; _c7 , Septic Final 6 -(7- -#4:2q Framing 7— J- 7(< (To include Roof in place and Windows and Doors installed). Notes: , Y -4_,..,„,"--- J74a 4• o -1 %—%G - 7 ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. OVED )DO NOT DESTROY THIS CARD 6 By+ lig t _F£1 ..