Loading...
HomeMy WebLinkAboutApplication- Permit"Fit /573 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 401 Glenwood Springs, Colorado 81601 Permit Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY 8/20)18 4626 Assessor's Parcel No. This does not constitute a building or use permit. Owner's Name Ryobi Thtnxfo!(Dn Present Address 210 10m57 -644A--C Phone 92t - ?WS System Location I UYI �rX C Oat Legal Description of Assessor's Parcel No. 5393 -203 -co -co /jQ SYSTEM DESIGN Septic Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Number of Bedrooms (or other) Required Absorption Area - See Attached Special Setback Requirements: Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine - 6 months in jail or both). White -APPLICANT Yellow - DEPARTMENT GARFIELD COUNTY SEPTIC PERMIT APPLICATION 108 8°i Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 www.eazfield-coots .com 1 Parcel No: (this information is available at the assessors office 970-945-9134) z3,13 y 20 O a _ 0 x /' (� (J ('C/'1 —OD— Bu' din I 4106 2 Septic Permit #:+ Job Address: Wan addres has not 13IIL 44 been a i ned, please provide Cr, Hwy or Street Name & City) or and legal description ta.... CS1t C4, 3 1 Lot ¢e: �piais of No• R - f73"fri Su d./ lock N : J St; d./ Exe ton: powen-;i evict Lr ct M �/�7 —i 4 APPROVAL Owner: (property "V.,' ovmer) obi F 9 Mailing Address 110 .-tMksf. C. fo &e f j gtf vpYPh: Gs t caea( 476 qzg c Alt Ph: nJ 4 g , >,,.1��� - 5 trac OtIar: or. (9it C' atl' g Addr s M ilte vewA0� f) 41, P : 76-'n i-acv� Alt h: ' :et_` '_� 6 meer. neer Maili g ddress /��n� �M1^,� Z -P 05 -t -f (11140OYIt-6 Ph i1ot-b`3rl It Ph: A-Osq-630 7 PERMIT REQUEST FOR: k New Installation ( ) Alteration ( ) Repair 8 WASTE TYPE: ( )Dwelling ( )Other ( )Tr nsient Use. ( Commercial or industrial )Non- Domestic wastes - Describe ,t 9 BUILDING OR SERVICE TYPE: Number of bedrooms Garbage Grinder ( )Yes ( )No 10 SOURCE & TYPE OF WATER SUPPLY: ( )WELLOSPRING If supplied by COMMUNITY WATER, give name of supplier. ( )STREAM OR CREEK ( )CISTERN �� 11 DISTANCE TO NEAREST COMMUNITY SEWER Wasaneffort made to connect to the Community System? SYSTEM: IY\ rsatl. ‘DPiii' - YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PER IT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: Depth to let Ground 00 (,Ify%Ir'L Water Table ? b" Percent Ground Slope .2--b7 a 13 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISM) PROPOSED: ( )Septic Tank ( )Aeration Plant ( )Vault ( )Vault Privy ( )Composting Toilet ( )Recycling, Potable Use ( )Recycling, other use ( )Pit Privy ( )Incineration Toilet ( )Chemical Toilet ( )Other- Describe 14 FINAL DISPOSAL BY: �Absorption trench, Bed or Pit ( )Underground ( Wastewater pond ( )Other- Dispersal ( )Above Ground Dispersal ( )Evapotranspiration ( )Sand filter Describe 15 Will effluent be discharged directly into waters of the state? ( )YES 30 16 PERCOLATION TEST RESULT: Name, address & telephone of Name, address & telephone of (to be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No.1 Minutes per inch in hole No.3 No._ Minutes per inch in hole No.2 Minutes per inch in hole RPE who made soil absorption test: RPE responsible for design of the system: 17 Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional test and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and legal a tion for perjury as provided by law. OWNERS SIGNATURE 0 twv.e,r ie t-yso-c •?-0-L—_,, • ' 1 DATE STAFF USE ONLY Permit Fee: -33 Perk Fee: Tit Total fees: S-1-3 Bu' din I 4106 Permit N: Septic Permit #:+ , Issue Date: 1 Building & Planning Dept 0 APPROVAL DATE N O Powers Art Learning Center DRAFT Powers Art Learning Center 3e ®VI Zig mom datTEI 7) CO AP //& i' fi 8t f{iiti�'i:RRi iiiiii;7iE 11 NUM MOM 7.6' TO NEAREST •- NOTES: EXCAVATION INSPECTED BY THE ENGINEER TO CHECK SOIL EXISTING WELL HEADCONDITIONS AND PROVIDE ADDITIONAL RECOMMENDATIONS RETAIN AND PROTECT AND/OR MODIFICATIONS TO THE ABSORPTION FIELD DESIGN. \+ GRADES AND OWS LAYOUT VERIFIED BY THE CONTRACTOR AND INSPECTED BY THE ENGINEER. PUMP SYSTEM INSTALLED AND INSPECTED BY SUPPUER (VALLEY PRECAST) AND/OR OTHER QUALIFIED SERVICE PROVIDER. HIGH POINT TRANSPORT UNE AT MANIFOLD TEE FITTING E NOTE: INSTALLED SIMPLEX DOSE PUMP ASSEMBLY USE MIN. 1/2 HP SEWAGE PUMP SINGLE PHASE, 120 VOLT ELECT. SERVICE STATIC HEAD - APPROX. 5 FEET TOTAL DYNAMIC HEAD (TDH) - APPROX. 11 FEET AT DISCHARGE RATE OF 27 GPM INSTALLED 44 ELJEN IN -DRAIN UNITS IN 2 BEDS WITH 2 ROWS EACH CONTAINING 2 ROWS OF 11 UNITS EACH. 540 SQ. FT. OF TREATMENT AREA IS PROVIDED. BED HAS MET ALL SETBACK REQUIREMENTS. THE SYSTEM IS PLUMBED FOR ALTERNATING EQUAL PRESSURE DISTRIBUTION. THE IN -DRAIN UNITS ARE INSTALLED AT LEVEL GRADE OVER 24" OF SELECT FILTER CONCRETE SAND. THE DEPTH OF EXCAVATION IN EACH BED MAY VARY TO ACHIEVE A MAXIMUM DEPTH OF 48 INCHES TO THE BED BOTTOM SURFACE BELOW THE PROPOSED GRADE. INSTALLED WITH MINIMUM 12" COVER OVER TOP OF IN -DRAIN UNITS. GRADED TO PROVIDE POSITIVE DRAINAGE OFF OF BEDS. 1 1/4* PVC SCHD-40 PERFORATED PIPE DISTRIBUTION LATERALS. DRILLED ji" DIA. ORIFICES EVERY 2' ALONG PIPE. INSTALLED LATERALS LEVEL, W/ SNAP ON ORIFICE SHIELDS, OVER CENTER OF PLACED IN -DRAIN UNITS. 1.5" FLUSH LATERAL WITH BALL VALVE. INSTALLED ASSEMBLY IN IRRIGATION VALVE BOX WITH INSULATION AND UD. (TW. END EA. PIPE), ,E Y/ 4" OBSERVATION PEIZOMETER RISER INSTALLED FROM BOTTOM OF SAND LAYER USE 4* PVC W/ THREADED CAP, SAW SLOTTED PERFORATED TO TOP OF SAND (Tip.) DUAL PRESSURE DOSE TRANSPORT LINES. INSTALLED 1.25" SCHD-40 W/ 2' MIN. DEPTH OF BURY. PIPE BEDDED W/ CL -6 ROAD BASE. INSTALL AT MIN. 2X TO ALLOW DRAINBACK TO TANK. 1 INSTALLED 3 -COMPARTMENT 1500 -GALLON CONCRETE SEPTIC TANK WITH PRECAST RISER ADAPTER AND 24" DIA. BY 36" DEEP PVC ORENCO RISERS WITH UDS AT THE SURFACE. (USED VALLEY PRECAST ITEM-1500T-3CP-P-HH) 3RD COMPARMENT DOSING CHAMBER WITH 30" DIA. RISER AND VENTED UD. INSTALLED ORENCO DUPLEX EFFLUENT PUMP ASSEMBLY. (PVU57-1819-L W/P300511 PUMPS), W/ 1.25* DISCHARGE ASSEMBUES. DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROXIMATELY 2'-3'. TOP RISER UD EL APPROX. 6255.5± PROPOSED GRADE 1.25" PERFORATED PRESSURE DISTRIBUTION LATERALS EXISTING GRAD 150. TO NEAR DRAIN GE SW T E 4" PVC GRAVITY SEWER LINE BED W/ CLASS -6 AT 2X SLOPE± DISTRIBUTION MAINFOLD TWO WAY CLEAN EXISTING GRADE PROPOSED GRADE / ACCESS RISERS OUT INSPECTION PORT EXISTING GRADE - SELECT BACK FILL - NATIVE SOIL FILTER FABRIC MIRAFI N-140 1-1/4" PRESSURE PIPE TRANSPOR LINES FROM DOSING TANK TO MANIFOLD SLOPE TO ALLOW DRAINBACKAT MINIMUM 2%SLOPE PROPOSED ART AND LEARNING CENTER FINISH FI OCR EFFLUENT DRAIN LINE AT MINIMUM 2% SLOPE PRIMARY SEPTIC COMPARTMENT 1/4" DRAIN BACK ORIFICE -SEWAGE PUMP W/ DISCHARGE ASSEMBLY SEPTIC TANK USE VALLEY PRECAST 3 COMPARTMENT TANK WITH PECAST RISER ADAPTORS AND DUPLEX PUMP ASSEMBLY. CROSS SECTION SLOPE DETAIL N.T.S. LANDSCAPE AREA COVER VEGETATION, NATIVE OR OTHER SUITABLE VEGETATIVE COVER 1.25" SCHD-40 CUSTOM PERFORATED DISTRIBUTION LATERAL PIPE 3:1 SIDE SLOPE (TYP. AROUND PERIMETER) ELJEN IN -DRAIN TREATMETN UNITS SAND 24" SAND FILTER MEDIA LAYER -- COARSE TO MEDIUM SAND EFFECTIVE SIZE 0.25-0.6 MM, MATH UNIFORM. COEF.=< 4.0 USE CONCRETE SAND HYDRO COMPACTED SAND WITH WATER AND LEVEL TOP SURFACE ORGANIC MATERIAL REMOVED AND SCARIFY SURFACE AT GRADE UNDISTURBED - EARTH 1.25" PVC HDPE PRESSURE PIPE SLOPETO TO DRAIN BACK TO TANK TYPE A UNITS ARE 24"x48"X7" 1.25". SCHD-40 PVC MANIFOLD PIPE �-t THE IN -DRAIN UNITS INSTALLED LEVEL END TO END WITH THE PAINTED STRIP FACING UP. GEOTEXTILE SAND FILTER TREAMENT BED SYSTEM N.T.S. ;1 ) 111/./ TOP OF 24* SAND LAYER BASAL AREA = 246 S.F. * LOCATION OF CONTROL BOX PROPOSED UNDERGROUND ELECTRICAL Ov VEGATATION TOPSOIL LAYER MIN. 5" AERATED SOIL ZONE FILL LAYER 0 NATIVE SOIL FILTER FABRIC (see section detail) CUSTOM PERFORATED PVC PRESSURE DISTRIBUTION PIPE ST WELLING TWO WAY CLEANOUT r DISTRIBUTION SYSTEM NOTES: EQUAL PRESSURE DISTRIBUTION OVER THE LENGTH OF THE GEOTEXTILE SAND FILTER FIELD WILL BE MAINTAINED BY THE INSTALLATION OF 1.25" SCH 40 CUSTOM PERFORATED DISTRIBUTION LATERALS W/ 3/16 INCH ORIFICES DRILLED EVERY 2.0 FEET ALONG THE PIPE. THE DISTRIBUTION LATERALS SHALL BE INSTALLED WITH ORIFICE SHE1LDS OVER THE ORIFICES ORIENTED DOWNWARD OVER THE TOP OF THE IN DRAIN UNITS. CAP EACH DISTRIBUTION LINE W/ A BALL VALVE AND ADD FLUSH OUT PIPE EXTENSION ALL CONTAINED IN A VALVE BOX. IN -DRAIN UNIT STRAPPING CUSPATED PLASTIC CORE NON -WOVEN FILTER FABRI 24" FILTER SAND USE CLEAN CONCRETE SAND NATIVE SOIL ).Jr � sir C \I c? -• VARIES 12" MIN. 1.5" ( ( , _ ......___L EN ib „ elp 4 gil..ru. ._.!‘... .....!‘ 7" 64 'r ,; yre 24" INSTALLATION NOTES Eljen In -Drain Supplier Contact: Hans Schenk 970 626 2621 Bio Septic Components, LLC 317 Tower Road South Ridgeway, CO 81432 1. THE BED SHALL BE EXCAVATED LEVEL INSTALL FILTER SAND AND HYDRO COMPACT. REPLACE ANY UNSUITABLE SOIL OR BOULDERS SAND. 2. THE WIDTH OF THE EXCAVATION SHALL BE LIMITED TO PLACE THE IN -DRAIN UNITS AND SAND. MAINTAIN 12" OF SAND BETWEEN ROWS AND 6" AROUND PERIMETER OF IN -DRAIN UINTS. 3. BOTTOM OF THE TRENCH SHALL BE FREE OF ORGANIC MATERIAL AND ROCKS OVER 12 INCHES IN DIAMETER. THE BOTTOM OF THE TRENCH SHALL BE SCARIFIED OR RAKED, REPLACE SOIL OR ROCKS AS NEEDED. 4. THE IN -DRAIN UNITS SHALL BE INSTALLED LEVEL END TO END WITH THE PAINTED STRIP FACING UP. 5. INSTALL PERFORATED PIPE OVER THE TOP OF THE IN -DRAIN UNITS ON CENTER AND SECURE WITH ONE ELJEN CLAMP PER UNIT. ORIENT PERFORATIONS DOWNWARD WITH ORIFFICE SHIELDS. 6. INSTALL FILTER FABRIC OVER PIPE AND TOP OF IN -DRAINS AND DRAPE DOWN THE SIDES TO THE TOP OF THE SAND LAYER. SECURE FABRIC WITH CLEAN EXCAVATED FILL MATERIAL 7. BACKFILL IN -DRAIN SYSTEM WITH SUITABLE EXCAVATED FILL FREE OF ROCKS OVER 2.5 INCHES IN DIAMETER. AVOID EXCESSIVE COMPACTION OF FILL. AVOID COMPACTION DAMAGE TO SYSTEM WITH EXCAVATION EQUIPMENT 8. FINISH GRADE TO PREVENT SURFACE PONDING. REVEGATATE WITH APPROPRIATE GROUND COVER AND PROTECT FROM EROSION. IN -DRAIN SYSTEM DISPERSAL/ABSORPTION/TREATMENT BED TESTING, INSPECTIONS AND CONSTRUCTION MANAGEMENT 1. ADDITIONAL INSPECTIONS AND RECOMMENDATION WILL BE MADE BY THE ENGINEER DURING CONSTRUCTION TO APPROVE THE LAYOUT OF THE MOUNDED SAND FILTER BED SYSTEM, VERIFY INSTALLATION OF SPECIFIED MATERIALS AND OWS COMPONENTS. 2. PRIOR TO CONSTRUCTION OF THE PERMITTED SYSTEM THE ENGINEER SHOULD BE CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE CONTRACTOR, ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND SCHEDULE INSPECTION SITE VISITS BASED ON CONSTRUCTION PROGRESS. A PRE-OWS CONSTRUCTION MEETING WITH THE ENGINEER, THE CONTRACTOR, ELECTRICIAN AND THE QUALIFIED INSTALLER IS REQUIRED PRIOR TO INSTALLATION OF THE OWS COMPONENTS. 3. REGULATIONS REQUIRE THAT THE DESIGN ENGINEER OF RECORD PERFORM SITE INSPECTIONS OF THE PERMITTED SYSTEM DURING CONSTRUCTION AND PROVIDE "AS -BUILT" DOCUMENTATION OF THE INSTALLED SYSTEM TO THE THE COUNTY AFTER CONSTRUCTION IS COMPLETE. WE RECOMMEND THAT INSTALLED OWS COMPONENTS BE SURVEYED TO OBTAIN REQUIRED AS -BUILT INFORMATION. 4. CONTRACTOR SHOULD DISCUSS ISSUES REGARDING SPECIFICATIONS, INSTALLATION AND OPERATION OF OWS MECHANICAL SYSTEMS AND CONTROLS WITH THE SUPPLIER/INSTALLER AND/OR THE ENGINEER. 5. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON OUR EVALUATION OF THE EXISTING AND PROPOSED SITE CONDITIONS AND INFORMATION SUPPLIED TO US BY OTHERS. IF SITE CONDITIONS ARE FOUND TO BE DIFFERENT FROM CONDITIONS ASSUMED OR INDICATED, WE SHOULD BE NOTIFIED TO EVALUATE ANY EFFECT ON THE PROPOSED OWS. Design Calculations Building C OWS The design flow is calculated as follows: Non -Profit Art and Education Facility Maximum No. fulltime Employee Staff= 5 persons Maximum Peak Day Transient Visitor Population = 100 persons From the State 1. S. D. S. Regulations: Max. Design flow (Qct) = # of people x (avg. flow) x 1.5 gal/person/day. Gallons per day per person for staff employees = 15 gall/person/day Gallons per day per person for Transient Visitors = 5 garl/person/day Qd=Staff Employees: 5 persons 0 15 gpd = 75x1.5 = 1.12.5 gpd Qd=Transient Visitors: 100 persons 0 5 gpd = 500x1.5 = 750 gpd Design flow Qd = 862.5 gpd Assume 870 gal/day Septic Tank Design V = 870 gal/day * 1.25 days = 1087 gallons. Use a 1500 gallon, three compartment septic tank with dosing basin. Percolation testing will performed by Hepworth Pawlok Geotechnical, Inc. in the location of the proposed treatment absorption field to verify design assumptions. The average percolation rate is estimated to be between 20-30 minutes per inch. A rate of 30 minutes per inch is used for design. Elgen ln-Drain/Geotextile Sand FllterTreatment System Area Design Average percolation rate of 30 minutes per inch. Standard absorption area equation yields: A (sf) = (Od *(t) where A = Area; 5 t = time in minutes per incrh=30mpi Qd = flow (gal/day) = 870 gpd A = = 870 *(30) 3 = 954 sq. ft. 5 Elgen In-Drain/Sand filterTreatment System Design for use of single pass secondary geotextile sand filter treatrrnent system. Apply sizing credit reduction of 5.4 SF equivalent absorption area per L.F. for full pressure dosed system w/ no other reductions in assumed flow. A(credit reduction)= A / 5.4 = 954 / 5.4 = 176 L.F. Each In -drain unit is 2 feet wide by 4 feet long. Number of Eljen In -Drain units required equals 176 L.F. / 4 FT = 44 units. Initial treatment surface area equal to 176 L.F. x 2 FT = 352 S.F. required Use 44 Eljen In -Drain units over approximately 540 S.F. of select sand 24" deep. Total treatment surface area equal to 44 units x 8 SF = 352 S.F. provided The total infiltrative surface area is 540 S.F. horizontal (arena of (2) 4' x 6' sand beds) TYPICAL YARD LANSCAPED SURFACE OR AGGREATE PAVED SURFACE 6" MIN. - 4" TALL/./BLUE BOARD 1F PTH OF COVER IS LESS THAN 3' EXCAVATED MATERIAL COMPACTED TO 90% STANDARD PROCTOR CLASS 6 ROAD BASE TRENCH CROSS-SECTION FOR SDR -35,26 OR HDPE PIPES N.T.S. OWS SYSTEM NOTES 1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND COUTNY INDIVIDUAL SEWAGE DISPOSAL SYSTEM (15DS) REGULATIONS. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION. 3. ALL SEWER LINES TO BE SDR -35 BEDDED IN CLASS 6, SDR -26 BEDDED IN SCREENED NATIVE OR SCHEDULE 40 P.V.C. PIPE BEDDED IN SCREENED NATIVE MATERIAL UNLESS NOTED OTHERWISE. 4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE. 5. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM. 6. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO THE FINISHED SURFACE GRADE. 7. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET. INSTALL THE INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW EASY INSPECTION AND MAINTAINANCE OF TANK FROM THE TANK RISERS. 8. WE RECOMMEND THE INSTALLATION OF A 4" EFFLUENT FILTER CONTAINED IN THE 4" BAFFLE OUTLET TEE OF THE SEPTIC TANK. THE FILTER SHOULD BE INSPECTED EVERY SIX MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED AND CLEANED WHEN THE TANK IS PERIODICALLY PUMPED OR AS NECCESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO BE WITHIN 6" BELOW THE ACCESS LID. 9. THE TREATMENT BED MUST BE MARKED AND PROTECTED TO PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC. 10. THE ENTIRE TREATMENT BED SURFACE MUST BE SODDED OR RE -VEGETATED WITH GROUND COVER. 11. THE TREATMENT BED SURFACE MUST BE CROWNED TO DIVERT SURFACE DRAINAGE AWAY FROM THE BED. 12. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND SEPARATION DISTANCES FOR THE OWS COMPONENTS. 13. THE BED SHALL BE LEVEL WITH DISTRIBUTION PIPES INSTALLED FOR EQUAL PRESSURE DISTRIBUTION. 14. THE BED SHALL BE OVER EXCAVATED TO ALLOW PLACEMENT OF A MINIMUM OF THE SAND TREATMENT LAYER. THE BOTTOM SURFACE AND SIDEWALLS OF THE TRENCH TO BE SCARIFIED AND RAKED AS NECCESSARY PRIOR TO PLACEMENT OF THE SCREENED ROCK. 15. THE TREATMENT BED SHALL BE CONSTRUCTED WITH THE IN -DRAINS UNITS PLACED WITH A MINIMUM OF 24" OF CONCRETE SAND BELOW AND ALONG THE SIDES OF THE UNITS. THE IN -DRAINS, SAND AND DISTRIBUTION PIPES SHALL BE PLACED IN A FILTER FABRIC ENVELOPE OVERLYING THE SCREENED ROCK LAYER. 16. THE MINIMUM COVER OVER THE TOP OF THE IN -DRAIN UNITS SHALL BE 10 INCHES NOT TO EXCEED 24". THE TRENCH BOTTOM SURFACE AND SIDEWALLS SHALL BE SCARIFIED AND RACKED IF SMEARING OCCURS. 17. THE PERFORATED DISTRIBUTION PIPE, SAND AND THE 1N -DRAIN UNITS SHALL BE ENVELOPED WITH FILTER FABRIC. TO THE BOTTOM OF THE BED. THE TRENCH 1N -DRAIN UNITS WILL BE BACKFILLED TO THE SURFACE WITH EXCAVATED MATERIAL VOID OF ROCKS. THE BACKFILL MATERIAL SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 4" DEPTH OF TOPSOIL 1S TO BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE. 18. BALL VALVES (SIZE PER PLAN) SHALL BE INSTALLED ON THE TERMINAL ENDS OF THE PERFORATED DISTRIBUTION PIPE AND HOUSED IN A VALVE BOX. 19. ALL INSTALLATION OF IN -DRAIN UNITS SHALL BE IN CONFORMANCE WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS. THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK DISTANCES: 10 feet from any property line. 25 feet from any potable water supply line. 20 feet from any occupied dwelling. 100 feet from any well, spring or cistern. 25 feet from drainage swats or ditches 50 feat from any stream or water course. DISTRIBUTION SYSTEM NOTES: 1. EFFLUENT FROM THE SEPTIC TANK WILL DISCHARGE TO THE TANK'S DOSING BASIN WITH A DUPLEX SEWAGE PUMP ASSEMBLY. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO EACH TREATMENT BED VIA THE SPECIFIED INDIVIDUAL TRANSPORT LINE TO THE SPECIFIED PRESURRE MANIFOLD AT THE HEAD OF THE BED. (SEE PLAN CALLOUTS NOTES) 2. THE SPECIFIED CUSTUM PERFORATED PRESSURE DISTRIBUTION LATERALS WILL BE INSTALLED OVER THE TOP CENTER TO THE IN -DRAIN UNITS WITH ORIFFICE SHIELD AT EACH ORIFFICE. THE DISTRIBUTION PIPES WILL HAVE 3/16" ORIFFICES DRILLED AS SPECIFIED AT EQUAL INCREMENTS ALONG THE PIPE. (SEE PLAN CALLOUTS) 3. THE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY TO EACH IN -DRAIN ROW IN THE BED. THE MINIMUM SLOPE OF THE DISCHARGE LINE FROM THE DOSING TANK TO THE PRESSURE MANIFOLD SHALL SHALL BE INSTALLED AT A MINIMUM 2% SLOPE TO ALLOW FOR DRAIN BACK, ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTIONTHROUGH THE SYSTEM. GENERAL NOTES: 1. THE OWS SYSTEM AND EXISTING LOT CONDITIONS AS SHOWN ON THE PLAN AND THE DETAILS ARE BY SOPRIS ENGINEERING. THE PROPOSED CONDITIONS ARE PROVIDED BY THE ARCHITECTS. Pump Selection for a Pressurized System -Input Parameters Mice Size Residual Head at Last 0€ifice Orifice Spacing Number 01 Laterals per Cell Lateral Length Lateral Lire Size Lateral Pipe Class/Schedule D istribrirg Verve Madel Me sTold Length Manifold Lite Size Manifold Pipe Class/Schedule Lit to Manifold Transport Length Transport Line Size Transport Pipe Gass/Schedule Discharge Assembly Size Flow Melo 'Add-on' Fri¢liwn Losses 3)16 inches 20 feel 200 feet 2 44.0 feel 1.25 itches 40 None 3.0 feet 1.25 inches 40 7.0 fent 25.0 feet 1.25 innchres 40 1.25 inches None inches 0.0 feet - Calculation Minium Flow Rate per Orifice Numbel d Orifices per Zone Total Actual Flaw Rate Nrarber of Lines per Zone %Flow Deferential lot and Last Orifice lift to Marefdd Residual Head at Last Orifice Head Loss in Laterals Head Lass Through Distributing Valve Head Levi in Manifold Heed Lass in Transport Pipe Head Loss Through Discharge Head Loss Ttaough Flow Mel* Add-on' Friction Losses 0.62 gpm 46 29.1 ppm 2 10.3% 7.0 feet 2.0 feet 0.5 feet 110 feet 0.1 feet 2.7 feet 4.2 feet 0.0 feet 0.0 feet Total Flow Rata 29.1 gpm TDH 16.5 feet 300 270 Ment Pumps PTA Series 1,2 hpto t -I+2 np 210 tpu 10 20 Net Discharge,gpm 30 40 • hiIlr! Otranto Systeme tnriv::.nr,;ra1 BDG A1f1WAY NANJ: u: sunIcnurtiJIi ILN rad .1t{,.!3.13 -9.F1.2 1FIFPFfIVF PUMP CURVE CALCULATION C377 (0//50/4 r - e •"`� � z '-tom ifo L Lu a) 0 N m 1- z m U z DESIGNED BY m z a CHECKED BY S OPRIS ENGINEERING, CONSULTANTS] 1- w 0) z 2 Lcs O Lu >- m z O rn w 0 z POWERS ART AND LEARNING CENTER to m U) I J Q Q 2 w 4! J w Cn () w V) < 0 LJJQ Z Q UJ 0 DATE: 05-26-09 JOB NO. OWN MUMS SHEET 26243.02 1 OF 1