HomeMy WebLinkAboutStructural Steel Inspection Report 06.27.17THUNDER MOUNTAIN TESTII{G
2970 N. Ronlin Avenue / Grand Junction, Colorado BlS04
office (970) 2s6-9965 Cell (970) 210-7008 Fax (970) tt4-7067
E-Mail : kx kid3g@aol.com / www.th u nderm ountaintestin g.com
CUC Construction
635 Glassier Drive
Carbondale. CO 81623
June 27.2017
ATTN: Mr. Ben Sanders
RE:Mine Drop Building
1850 Transfer Trail
Glenwood Springs. CO
*Field Inspection
Permit #4574
Dear Mr. S¿rnders.
As requested. structural steel special inspection was conducted per the IBC 2015
Edition - Chapter l7: Structural Tests and Special Inspection and the City of Glenwood
Springs requirements. I arrived at the job site at l2:00 PM. I met with you to be briefed
about the project requiring my presence. The certitìed welder perlorming the welding *as
Mr. Brian Stoddard. I have been provided with Mr. Stoddard's Welder Qualification Test
Record (WQTR) and Continuity Record. Documents viere reviewed and all were
obsen'ed to be acceptable with project requirements. The drawings utilized during
inspection were prepared by Alpine Edge Engineering. The structural drawing 53.2
provides the pertinent details as follows: Detail 4 - Glu Lam beanr pocket. Detail 8 -
Column Cap to Beam and to Column welded connections. and Detail I I - Colurnn Base
Plate to Column welded connection. Prior to my inspection I received and reviewed an e-
tnail conespondence for the project structural engineer Mr. Mike Arbaney with Colorado
Structural, Inc. accepting a non-detailed column splice. Please refer to the aÍached
correspondence lor pr oj ect documentation.
Visual rvelding inspection was conclucted at level L2 Stl. The items inspected
were the following: l) Grid point D.4 & 3: column to column cap and column cap to
beam welded connections. 2) Grid point 8.7 &.3: column to column cap and column cap
to beam rvelded connections, ând all welding on a Glu Lam beam pocket,3) Grid point 3
& C: all welding on a Glu Lam beam pocket. and 4) Grid point 3 & D: all welding on a
Glu Lam beam pocket. Visual welding inspection was also conducted at the crawl space
level as follows: I ) Grid point 8.7 & 3: column to base plate welded con¡rection and all
welding on a Glu Lam beam pocket, 2) Grid point 8.7 & 2: column to base plate. colunrn
10 cap plate and cap plate to beam welded connections. and all welding on a Clu Lam
beam pocket. 3) Grid point D.4 & 2: column to base plate, column to cap plate and cap
plate to beanl u'elded connections. anil all welding on a Glu Lanl bearn pocket.4) Grid
Page2 of2
point 2 & c: all welcling on a Glu l-am beam pocket. and 5) Grid point 2 & C.9: oll
welding on a Glu Lam beam pocket. All areas of inspection referenced above were
observed to comply with project requirements and AWS D l .1 : Edition 20 1 S. Clause 6 -Table 6.1.
William K. Bwgin
AWS CWI #11120021
Thunder Mountain Testing
L.
AWS CWI #91040201
ICC Certified #0863569-St & S2
ASNTNDT Level lll #30242
Fwd: Mine Drop retaining wall and column splice
Mike Arbaney P.E
Colorado Structural. lnc.
rcl; u:lll:r.!,¡':L::
t at: il¡ ir.ll - -l-1jlllj-!
!tl-.,l.grlgritþ:gt¡*lrdlill'!
Page2 of2
https://mai l.aol.com/webmai l-std/en-us/printMessage 7tsnrJû
Fwd: Mine Drop retaining wall and column splice
From: lMlllam Burgin <smoothfitter@gmail.com>
To: Scott Maxwell <kxkid39@aol.com>
Subject Fwd: Mine Drop retaining wall and column splice
Date: Tue, Jun 27, 2017 6:59 pm
Page I ofZ
Forwarded message
From: Ben Sanders <sltgjglLgliliçllg¡lLul.qlU]>
Date: Tue. Jun 27. 2017 at l2:32 PM
Subiect: Fwd: Mine Drop retaining wall and column splice
To: sntortth iìtte r. rt, gtttiti l.conr
Bill
See note below from Colorado Structural (the E.O.R for project) indicating the splice to the column
is structurally sound and works in these locations.
Thanks
Ben
Sent from my iPhone
Begin tbrwarded message :
From : Mike Arbaney <j¡rr L cl.llU:l-rr.¡:iLrlA¡¡f,UT_lljil *¡¡ rì>
Date: June 26, 2017 at 17:34;l I MDT
To: Ben Sanders <i1|el'j !.lg¡1!gjfg¡¡3-¿!j i. ct¡ ¡ rl>
Cc: Bruce Barth <b¡'r-lc*ri,r'{:dhti¡re hilcctt¡l"e .ür r¡1¡;>. ernesto cuc
<gn'ì.t: frtr:sto ¡r lrr.rt r'¡Ït i l.eollr)
Subject: Re: Mine Drop retaining wall and column splice
Ben.
f'he column that has been spliced 10" has been spliced with the same material f'or the
additional 10". They have done a full penetration weld around the column. and also
added 20" long l/4" stiffener plates to two sides of the column. This rvorks structurallv.
The new'foundation wall that is going to be a 6'-0" tall wall will have a 36" looting ancl
will have half geo foam and half soil retaining. This will work with the same detail as the
building. Tlte new wall may be dowled into the existing building with #5 epoxy tlowels
Qyl6"o.c. with 4" embedment.
Please let me know if you need anytlring else.
T-hanks.
Mike Arbaney