Loading...
HomeMy WebLinkAboutRoof Assembly Report 07.17.17Iuly l7,2017 RED HOUSE architecture design + build Ernesto Cuc Cuc Construction 635 Glassier Drive Carbondale,CO 81623 Re Mine Drop Building 51000 Two Rivers Plaza Road Glenwood Springs, CO Subject: Roof Assembly Ernesto - With regards to the roof at the Mine Drop building, please accept this letter and attached specifications as verification of the installation of Class C materials. The roof underlayment is Owens Corning Weatherlock Specialty Tile & Metal waterproofing barrier with naturally weathering2í gauge cold-rolled comrgated metal roofing finish. This assembly meets the requirement for Class C requirements. Please call with any questions. Regards, arth, Architect.Contractor Red House Architecture Design + Build 815 Blake Avenue Glenwood Springs, CO 81601 a 6C 910 945 8240 w wr,v .redhousearchitecture.com 0826r-4 Þ ì \ 815 blake avenue glenrvood springs colorado 8l6l0l p 970 945 8240 r970947 9t3'l wrvw.redhouserchiteclure.com OWENs @ Weatherlock@ Special ity Tile & MetalROOFING Waterproofing Barrier Essential Weatherproofing Barrier. Tile and metaì shingles are water-shedding not waterproofing barriers. Weatherlock' Specialty Tile & Metal underlayment provides the weatherproofing protection your home needs to help prevent leaks. Extended UV exposure-Resists UV degradation when left exposed for up to 90 days. Waterproofing barrier-Adheres to roof deck and seals around nails for dependable, water-tight constructionl Peak performance- H igh punctu re and tear-resistant surface' Safe installation-single-layer polyester walking surface provides a slip-resistant work area. Added protection-Acts as a waterproof barrier in the most vulnerable sections of the roof to create a second line of defense. For optimal protection, apply to entire roof deck on 2:12 lo 4:12 pitch roofs'*** 3g-year limited warranty-Since tile and metal shingles are water-shedding not waterproofing, rely on WeatherLock underlayment to provide a long-lasting roof system l* Weatherlocle Specialty Tle & Metal Waterproofing Barrier are a component of the Owens Corning*Total Protection Roofing SystemlM^ The most important part of the rool? All of them. Construction Surface r4\Â.Jãl fiâtmlæEffi{FrrãrfL noortnelsvsreu -\lJ It takes more than just shingles to protect your home. It takes an integrated system of components and layers designed to withstand the forces of nature outside while controlling temperature and humidity Polyester non-woven fabric. Comprised of more lhan 8@/o recycled materials lnterior Reinforcement Durable Fiberglas@ Mat Adhesive inside. The Owens Corningt" Total Proiection Roofing Syslem'u^ gives you the assurance lhat all of your Owens Corningt" roofing components are working togelher to help increase the performance of your roof - and to enhance the comfort and enjoyment of those who live beneath it. Optional Owens Corning- products designed to support the Total Protect¡on Roofing System"^ - PINK' Fiberglas'u Blown-ln lnsulation - llluminator¡ Tube Skylight - raft-R-mate" Attic Rafter Vent ^ Erôludes non-Owens Corning* roofing produôls such as flash¡ng, lasteners and wood decking. ' See actual warranty for complele details, limitâtions and requirements *'" Ensure proper ventilation is met when applied over Ìhe entirê roof deck. I All values are approximate. 5 Applies for all areas thal recognize Miam¡Dade County Product Control S€ction Length ?1.3 ft. (21.73 m) wdth 3 ft. (.e1 m) Coverage 196 sq. ft. (18.21 m') Thickness 65 mils Applicable Standards and Codes ASTM D1970 ASIM E108,/UL 790 (Class A Fire Resistance) Florida Product Approval tcc-ESR 1783 Miami-Dade County Product approvalS Physical Properties Property Slip Resistance AStM ljl97r) Tile Slippage Resistance TAS 103 Pliability 1" Mandrel Bent at -20'F Tensile Strength ASTM D2523 Elongation at Break (modified bitumen portion) ASTM D2523 Permeance ASTM Ë96 Adhesion to Plywood, 40"F ASTM DSOs Adhesion to Plywood, 75'F ASTM D9O3 Tear Resistance ASTM D4037 Sealability around Nail ASTM D1 970 Low Temperature Flexibilily ASTM D1970 Waterproof in g lniegrity after Low Temperature Flex Waterproofing lnlegrity of Lap Modified asphalt Removable Backing Split, silicone release poly Recycled Content 9,760lo post-consumer TypicalValuest Property 2 sq. roll Test Method ASTM D1970 ASTM D1S7O Thermal Stability ASTM D1204 ASTM D1S7O OWENS CORNING ROOF¡NG AND ASPHALT, LLC ONE OWÉNS COÊNING PARKWAY TOLEDO. OHIO, USA43ô59 o 1-800-GET-PtNKowww.roof ing.owênscorning.com Pub. No. 1001 1 680-C. Pr¡nred ¡n U.S.A. April 2014. THE Pl N K PANTHER" & @ 1964-20'14 Metro-Goldwyn-Mayer Studios lnc. All Righls Reserved.The color PINK is a registered trademârk of Owens Corning. O 20'14 Owens Corn¡ng. All Rights Reserved. (Jacksonv¡llê) 32" Coverage ¿'13 - ril¡rfirilñlfl c! 'ta 718" CORRUGATED CondenseüIeonnical Relefen0e COMM 32"MINIMUM SLOPE PANE FASTEN 1:12 PANEL OVERVIEW Optional: Weathering Steel AZ50 per ASTM Al92 for painted Galvalume@ G90 per ASTM A 653 for Galvanized oPfu r*nrlrfon TESTING AND APPROVALS i-l-S mp-*tã[,F,nl"* ROOF ATTACHMENT Side Lap Fasteners between supports Panel Fastener at Supports Double Bead Tape Sealant FASTENING PATTERNS ROOF Panel Fastener (ïT Overdriven fasteners will cause panel distortions. Fasteners should extend 112" or more past the inside face of the support materìal. Thick panels (ex. 18 ga) or supports (ex. 112" steel) may require predr¡lling of holes for screws. S¡de Lap Fastenen 114"-14x718" XL Stitch Screw, 1'on center Tr¡m Fasteners: 114"-14 x 7/8" XL Stitch Screw 1iB" x 3/16" Pop Rivet Panel Fasteners: Attaching to Wood: #10-14 XL Wood Screw Attaching to Steel: <12 ga: #12-14 XL Driller FASTENER INFORMAT¡ON 718" GORRUGATED metalsales.us.com Jacksonville, FL 800.394.441 I Jefferson, OH 800.321.5833 Mocksviile, NC 800.228.6119 Nashville, TN 800.251.8508 Rock lsland, |L 800.7 47.1 206 Rogers, MN 800.328-931 6 CondensedTechnicalRelefen0e Seâttle, WA 800. 431.347 0 Sellersburg, lN 800.999.7777 Sioux Falls, SD 888.902.8320 Spokane, WA 800.572.6565 Temple, TX 800.543.441 5 Woodland, CA 800.759.601 9 o o C.lo É. O ¡.- æc! u) o ï*r--Q metal salest t !l manutacturng corÊorâriÐn Anchorage, AK 866.640.7663 Bay City, I'lll 888.777.7640 Deer Lake, PA 800.544.2577 Denver, CO 800.289.7663 Detroit Lakes, IVN 888.594,1394 Fontana, CA 800.782.7953 Fort Smith, AR 877.452.3915 l ndependence, l\AO 800.7 47 .001 2 SECTION PROPERTIES Bottom ln GompressionTop In Compression Outward Loadlnward Load Sxx in3/ft 2.s',3'3.5'4 4.5'5 2.s',3'3.5'4'4.5'5' Ga width tn Yield ksi Weight psf lxx ina/ft Sxx in3/ft lxx ina/ft 0.0624 227 159 107 50 la 227 159 107 72 50 372632501.02 0.0278 o.0624 0.0278 204 130 87 61 45 291 204 130 OI 61 4524501.33 0.0338 0.0801 0.0338 0.0801 291 0.1029 0.0450 0.1 02s 373 262 173 1'16 81 59 373 262 173 116 81 592250t./J 0.0450 0.1234 295 207 153 117 93 bY 295 207 153 117 93 6920JZ332.11 0.0525 o.1234 0.0525 ALLOWABLE UNIFORM LOADS, psf For various fastener spac¡ngs I . Theoletical section properties have been calculated pel AISI 2012 'North American Specification for the Design of Cold-Fonned Steel Str uctural Membets'. Ixx and Sxx are effective section properlies for deflection and bending. 2. Allowable load is calculated in accordance with AlSi 2012 specifications considering bending, shear, combined bending and shear and deflection. Allowable load considers thc 3 or rnore equal spans condition. Allowable load does not addlcss web crippling, fasteners, suppot material or load testing. Panel weight is not considered. 3. Deflection consideration is limited by a maxirnum deflection ratio ofL/180 ofspan. 4. Allowable loads do not include a I /3 stress increase for wind. .{.'#eÕi\tjt----''\*t,l/,,npf.kirLflit'It,tlI