HomeMy WebLinkAboutPlans Revisions Approved 11.13.2014D
0
w
18 EQUAL SPACES @ 24" EACH
—J
0
LU
EQUAL
L _
3
,
Is • IL_1 JL
Li LJ
L i '
i L 1 1\j
14 EQUAL SPACES @ 48" EACH
L (IY N
"--j)
V [17)
LiNLI
L„ A \r/ N
L)
_1 1
4
LJ
Li
trp
5
EQUAL
! , \,/ I --
Li ,
JM L_-; --, F-1
LI `-'1
fl T , T ;.\
L/ L1 1 I \I LA"1
7 7
_
1 111
PLLi P\./11
1 Li .12,1
L ILi
MAIN FLOOR
REFLECTED CEILING PLAN
1/4" = 1-0"
7
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,I
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Gamer
Registered Architect
u
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: garner_harryOmsn.com
\Veh site: gaiassociates.com
z
0
rT1
•
REVISIONS
JOB NUMBER
DATE
DRAWN BY
CHECKED BY
SHEET NUMBER
C
3
8 "o
\
/ -\
•
8"0
8 "0
8"�
•
\/
\
8"0
00
X
CO
X
8"0
235
\/
/■ \
8"0
1
•
\_/
/■ \
8"0
18X14
18X14
8"0
GF- 1
4"0 D
e-113.34-
41'
"0
•
\/
•
8"0
.7
10X10
8"�
•
00
18x14
10X8
1
10X10
.41011111111
1
48Ed° 0.
/
/
/
/
/
G
CO
8 "0
•
/jr•
00
14x14
/
/
/
/
12x12
8 "o
i■
CD
® 8"o
100
12x8
/
/
/
/
/
12x8
/
12x12
8"0
2
/
/
/
/
1OX10 DOWN
GF -3
8"0
1
00
J
Q
KE2h
00
(7)
8 "0
26x10
\•
/
/ \
04-
8"
80
8"
12x10
12x10
12x10
CO
•
8"0
•
\
\
/
/
/ \y
80
8N0
8165 6"
■
MN
0--
00
\
CO
/ - \
/ \
165 (D-1114-
18x14
65
MECHANICAL MAIN LEVEL FLOOR PLAN
1410"
320
®14"x 10"
320
SCALE: 1 /4"-1'-0'
NORTH
18x14
32 10"
320
1x10' 1_4x10"
320 320
18x14
we-
ao
KEY NOTES: <>
1. PROVIDE AND INSTALL 18X8 BRICK VENT AND MOTORIZED DAMPER FOR OUTSIDE AIR VENTILATION.
2. THIS MOTORIZED DAMPER SHALL BE INTERLOCKED WITH THE OPERATION OF GF -2.
3. THIS MOTORIZED DAMPER SHALL BE INTERLOCKED WITH THE OPERATION OF GF -1.
4. ROUTE 4" RIGID SHEET METAL DRYER VENT FROM THE FLOOR BELOW, UP IN THE WALL, THROUGH THE
EXTERIOR WALL, AND TERMINATE WITH APPROVED VENT CAP.
5. TERMINATE EXHAUST DUCT THROUGH THE EXTERIOR WALL WITH APPROVED VENT CAP.
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,I
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: prner_harry@msn.com
Web site: gaiassociates.com
•
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
M 1 -2
1. SCOPE OF WORK
A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS,
AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM
WHETHER SPECIFIED OR IMPLIED.
B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE
WITH THE 2012 INTERNATIONAL MECHANICAL CODE, ALL LOCAL
CODES, AND ALL OTHER REGULATION GOVERNING WORK OF THIS
NATURE.
C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL,
EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR
HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO
ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO
MAKE SUCH EXAMINATIONS.
D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR
"APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT.
2. PERMITS
A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICA-
TIONS AND PAY ANY AND ALL FEES.
3. SHOP DRAWINGS
A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR
EQUIPMENT TO THE ACHITECT/ENGINEER FOR APPROVAL.
THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP
DRAWINGS AND THEY SHALL BE CLEARLY LABELED.
4. FLEXIBLE TYPE DUCT
A. SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION COMPOSED
OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND
COATED FABRIC WITH A MINERIAL BASE. FLEXIBLE DUCT
CONNECTORS SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND
SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25
AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50.
B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE
THAN 6 LINEAR FEET PER RUN.
C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR
COLLAPSE FLEXIBLE DUCT.
5. REFRIGERENT PIPING
A. CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT
PIPING IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS AND IN SUCH A WAY AS TO BE
INCONSPICIOUS AND FREE FROM ANY POSSIBLE CONDEN-
SATION. INSULATE REFRIGERANT LINES WITH 2" OF FIBERGLASS
INSULATION WITH BACKING.
B. SHALL BE TYPE "L" COPPER TUBING, WITH WROUGHT
COPPER SOLDER TYPE FITTINGS SUITABLE FOR CON-
NECTION WITH SILVER SOLDER.
HVAC NOTES
6. DUCTWORK
A. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE "SMACNA" APPLICABLE MANUALS. ALL DUCTWORK
SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED
OTHERWISE.
B. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE
DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK
WHICH PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTI-
TION, OR AS OTHERWISE SHOWN ON DRAWINGS.
C. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS.
D. SMOOTH TURN RADIUS DUCTWORK OR TURNING VANES SHALL
BE USED THROUGHOUT WHERE FLOW EXCEEDS 150 CFM.
E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH
"SMACNA" STANDARDS AND ACCEPTED GOOD PRACTICE.
F. ALL DUCT DIMENSIONS SHOWN ARE NET INSIDE VALUES.
DIMENSIONS MAY BE CHANGED SO LONG AS THE NET FREE
FACE AREA IS MAINTAINED.
G. ALL INTERIOR DUCTWORK SHALL BE INSULATED WITH 1-1/2"
FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL
FACING. ALL DUCTWORK IN UNCONDITIONED SPACES SHALL BE
INSULATED WITH 2" FIBERGLASS INSULATING BLANKET WITH ALUMINUM
FOIL.
H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM
OF THE HVAC UNIT SHALL BE INTERNALLY LINED WITH A 1/2"
ACOUSTICAL DUCT LINER.
7. DRAINAGE PIPING (QNDENSATE)
A. SHALL BE TYPE L COPPER WITH BRAZED FITTINGS.
PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS
SHALL BE ROUTED TO FLOOR DRAIN OR INDIRECT WASTE DRAIN.
8. HVAC CONTROLS
A. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING
AND SENSORS AS REQUIRED. CONTROL MANUFACTURER
SHALL BE SIEMENS.
9. ELECTRICAL
A. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR
FOR LOCATION OF WIRING FOR EACH HVAC UNIT.
10. PIPE SUPPORTS
A. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING
STRUCTURE IN A NEAT AND WORKMANLIKE MANNER.
THE USE OF WIRE OR METAL STRAP TO SUPPORT PIPES
WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS
SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC
PIPING TO BE SUPPORTED EVERY 4 FEET.
11. GAS PIPING
A. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MAL-
LEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO
EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG
THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF
VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE
GREATER THAN 7" W.G. SHALL BE SCHEDULE 40 BLACK
STEEL PIPE WITH WELDED JOINTS.
12. MISCELLANEOUS
A. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND
SEALED WITH A SEALANT OF HIGH QUALITY AND LONG
LIFE, TO PREVENT INFILTRATION OF OUTSIDE AIR INTO
CONDITIONED SPACE.
B. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT
ROOF PENETRATION.
C. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS.
VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS
AT THE JOB SITE.
D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAM-
MATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIP-
MENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM
IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL
THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR
SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIP-
MENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL
FIT IN THE AVAILABLE SPACE.
13. TESTING AND BALANCING
A. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED
BY AN INDEPENDENT AGENCY, UNDER THE SUPER-
VISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED
TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE
ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.
14. GUARANTEE
A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE
GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE
OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT
PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S
EXPENSE.
B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR
SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES
CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK
OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM.
FAN SCHEDULE
GAS FIRED UNIT HEATER SCHEDULE
LWViv
lta
AVW'
AM
EQUIPMENT
NO.
EQUIPMENT
NO.
SERVICE
CFMINPUT
(MBH)
OUTPUT
(MBH)
C-
EMC-
IENCY
A.F.U.E.
GAS
RATE
(CFH)
GAS
CONN.
SIZE
VENT
OUTLET
SIZE
AIR
INLET
SIZE
ELECTRIC
& MODEL
OPTIONS -ACCESSORIES
SPS
V.-PH.-CY.
MOTOR
HP
GUH-1
GARAGE
4,400
300
240
80
353
1-1/2
6'0
6110
8.0
120-1-60
1/4
TRANE - GAND 030
NOTE - 1
GUH-2
GARAGE
4,400
300
240
80
353
1-1/2
6'0
6'0
8.0
120-1-60
1/4
TRANE - GAND 030
NOTE - 1
NOTES;
COMBUSTION GAS-FIRED PROPELLER UNff HEATER. PROVIDE REMOTE MOUNTED THERMOSTAT, DISCONNECT, AND MOUNTING BRACKETS.
1. SEPARATED
1
115-1-60
FAN SCHEDULE
GAS FIRED FURNACE SCHEDULE
LWViv
In
AM
EQUIPMENT
NO.
EQUIPMENT
NO.
EQUIPMENT
NO.
SERVICE
SUPPLY
AIR
(CFM)
OUTSIDE
AIR
(CFM)
E.S.P.
(IN. W.G.)
COOUNG
HEATING
FILTERS
EVAtHP AN
ELECTRICAL
MANUFACTURER & MODEL
OPTIONS -ACCESSORIES
NOM.
TONS
MBH
SENSIBLE
GAS
CFH
MBH
INPUT
MBH
OUTPUT
V.-PH.-CY.
MCA
MOCP
GF- 1
NORTH SIDE
1,600
200
0.5
4
41
136
120
108
2"
1
115-1-60
10
20
FRASER JOHNSON - TM9V120C
NOTE - 1
GF -2
SOUTH SIDE
1,600
200
0.5
4
41
136
120
108
2"
1
115-1-60
10
20
FRASER JOHNSON - TM9V120C
NOTE - 1
GF -3
EAST SIDE
1,600
200
0.5
N/A
N/A
136
120
108
2"
1
115-1-60
10
20
FRASER JOHNSON - TM9V120C
NOTE - 2
NOTES;
HORIZONTAL, 90+% EFFICIENT, SINGLE STAGE, MULTI -SPEED GAS FIRED FURNACE SYSTEM WITH MATCHING CASED EVAPORATIVE COIL PROVIDE MULTI SPEED MOTOR, DISCONNECT,
WALL TERMINATION VENT KIT, DIGITAL PROGRAMMABLE THERMOSTAT, POLYMER DRAIN PAN, FREEZE PROTECTOR & HANGING KIT W/ VIBRATION ISOLATORS. INLET CONDITIONS:
HORIZONTAL, 90+% EFFICIENT, SINGLE STAGE, MULTI -SPEED GAS FIRED FURNACE SYSTEM. PROVIDE MULTI SPEED MOTOR, DISCONNECT, CONCENTRIC WALL TERMINATION VENT KIT,
PROGRAMMABLE THERMOSTAT, POLYMER DRAIN PAN, FREEZE PROTECTOR & HANGING KIT W/ VIBRATION ISOLATORS. INLET CONDITIONS: ®80'DB/60'WB.
1. PROVIDE
CONCENTRIC
080'DB/60'WB.
2. PROVIDE
DIGITAL
FAN SCHEDULE
AIS COOLED CONDENSING UNIT SCHEDULE
LWViv
In
EQUIPMENT
NO.
EQUIPMENT
NO.
SERVICE
COOLING
CAPACITY
(MBH)
SEER
REFRIG. PIPING
ELECTRICAL
MANUFACTURER & MODEL
OPTIONS -ACCESSORIES
LIQUID
VAPOR
VOLT.-PH.-CY.
MCA
MOCP
CU -1
GF -1
48
14.5
3/8
3/4
208-1-60
32.7
50
FRASER JOHNSON - TCGF
NOTE - 1
CU -2
GF -2
48
14.5
3/8
3/4
208-1-60
32.7
50
FRASER JOHNSON - TCGF
NOTE - 1
N07ES:
MATCHING HORIZONTAL CASED EVAPORATIVE COIL (FRASER JOHNSON - MC), 4" CONCRETE HOUSEKEEPING PAD, TWO SPEED CONDENSER, LOW AMBIENT KIT DOWN TO 0'F, THERMAL EXPANSION VALVE,
UNE SET, ANTI -SHORT CYCLE TIMER, EVAPORATOR DEFROST CONTROL, RUBBER ISOLATORS, AND HARD START KIT.
1. PROVIDE
REFRIGERANT
42
FAN SCHEDULE
LWViv
SCHEDULE 0
EQUIPMENT
NO.
SERVICE
LOCATION
CFM
STATIC
PRESS.
(IN. W.G.)
MOTOR
MANUFACTURER & MODEL
OPTIONS -ACCESSORIES
WATTS
HP
RPM
VOLT.-PH.-CY.
EF -1
RESTROOM
CEIUNG
125
0.5
42
-
950
120-1-60
PANASONIC - FV-20VQ3
NOTE - 1
RESTROOM
CEILING
125
0.5
42
-
950
120-1-60
PANASONIC - FV-20VQ3
NOTE - 1
EF -2
EF -3
RESTROOM
CEIUNG
125
0.5
42
-
950
120-1-60
PANASONIC - FV-20VQ3
NOTE - 1
EXTERIOR WALL
2,800
0.5
-
3/4
1,590
120-1-60
GREENHECK - SE1-18-429-VG
NOTE - 2
EF -4
GARAGE
NOTES;
WITH DISCONNECT, REMOTE
WITH DISCONNECT, VARI-GREEN
WALL SWITCH, RUBBER -IN -SHEAR VIBRATION ISOLATORS, BACKDRAFT DAMPER, AND BLACK GRILLE.
EC MOTOR WITH MOUNTED POTENTIOMETER DIAL, BACKDRAFT DAMPER, WALL HOUSING WITH FLUSH EXTERIOR, AND 45' WEATHER HOOD WITH BIRD SCREEN.
1. PROVIDE
2. PROVIDE
CILLE
REGISTER DIFFUSER
SCHEDULE 0
EQUIPMENT
NO.
SIZE
TYPE
MANUFACTURER & MODEL
FINISH
OPTIONS -ACCESSORIES
A
14"x10"
SIDEWALL SUPPLY
PRICE - 535D
WHITE
DOUBLE DEFLECTION WITH 1/2" SPACING AND OBD
B
24"x24"
CEILING DIFFUSER
PRICE - SPD
WHITE
OBD WITH SQUARE TO ROUND TRANSITION -SEE DWG FOR NECK SIZE
C
24"x24"
RETURN GRILLE
PRICE - PDR
WHITE
22"x22" NECK SIZE FOR RETURN AIR APPLICATION. WITH SOUND BOOT.
D
12"x12"
CEILING DIFFUSER
PRICE - SPD
WHITE
OBD WITH SQUARE TO ROUND TRANSITION -SEE DWG FOR NECK SIZE
NOTES:
ALL MOUNTING TYPES WITH CEILING. ALL AIR DEVICES SHALL BE PROVIDED IN BLACK TO MATCH THE EXISTING CEILING.
1. COORDINATE
4
LOUVER SCHEDULE
AML
W
EQUIPMENT
NO.
SERVICE
WIDTH
HEIGHT
THICKNESS
OF LOUVER
MATERIAL
SCREEN
MANUFACTURER Sc MODEL
OPTIONS -ACCESSORIES
LV -1
BULK BOOKING EXHAUST
3'-4"
3'-4"
6"
ALUMINUM
BIRD
GREENHECK - ESD635
NOTE - 1
NOTES;
WITH KYNAR FINISH TO MATCH ADJACENT WALL
1. PROVIDE
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,I
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
111
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: garner_harry@msn.com
Web site: gaiassociates.com
u
z
v
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
M 1 -3
FAN GUARD
CONDENSING UNIT
REFRIGERANT GAUGE
CONNECTION
6" THICK CONC. PAD — EXTEND
6" BEYOND UNIT ALL AROUND
BACK—SEATED REFRIGERANT
VALVE
REFRIGERANT SUCTION LINE
WITH INSULATION
YREFRIGERANT LIQUID LINE
SIGHT GLASS WITH MOISTURE
INDICATOR
FILTER—DRYER
CONDUIT — POWER AND
CONTROL
AIR-COOLED CONDENSING UNIT
- SLAB MOUNTED AT GRADE
N.T.S.
REDUCING
BUSHING
EXHAUST —
AIR
INTAKE a ri
AIR
ELBOW J
OUTSIDE \\
WALL • ,
n•
O
O
• ,
CLAMP o
•
•
•
• •
A
•
o•
INTAKE
AIR
INTAKE
AIR
C � EXHAUST
AIR
18" MIN.
ABOVE
FINISHED
GRADE
1=11=1 .11=111
II=11=1=11=
1=11=1 = -'
CONCENTRIC WALL TERMINATION
INSTALLATION DETAIL
(TYPICAL FOR HIGH EFFICIENCY GAS FURNACES)
N.T.S.
POWDER ACTUATED
PIN(IF ALLOWED
BY CODE)
CONCRETE SLAB
1" X 16 GA.
STRAPS
WASHER
EXPANSION SHIELD
BOTTOM CHORD OF STEEL JOIST
USE THIS METHOD WHENEVER DUCTS
CAN BE GROUPED TOGETHER 1/2" ALL THREAD
1/2" ALL THREADROD
ROD SEE PROJECT DRAWINGS FOR
NUMBER & SIZE ---\
SHEET METAL
SCREWS
DUCT -SEE PROJECT
PLAN FOR SIZE
SINGLE RECTANGULAR DUCT
WOOD BEAM
STEEL BEAM
DUCT
DUCT
(-113
WHERE NOT LESS THAN 10FT. O.C.
MULTIPLE DUCT RUNS ON TRAPEZE HANGERS
2"X2" X 3 16" ANGLE ( NOTE: DUCTS SHALL BE SUPPORTED AT
/
LENGTH OF ANGLE EXCEEDS
6FT. USE INTERMEDIATE
SUPPORT)
SECURE STRAP
HANGERS TO
STRUCTURE
TURN STRAP
1"X18 GAGE STRAP
HANGERS UP THRU
30" ,0 1"X 1/8"
30" .0 AT 10' 0.C.
DUCT -SEE PROJECT
PLANS FOR SIZE
ROUND DUCT
1-1/2" X 1-1/2" X 1/8"
ANGLE BOTH SIDES
OF DUCT
SHEET METAL
SCREWS
FLOOR
DUCT RISER -SEE
PROJECT PLANS
FOR SIZE
SHEET METAL SCREWS
1-1/2" X 1-1/2" X 1/8"
ANGLE BOTH SIDES
OF DUCT
CURB
P 0 0 0 0
i'.....• .4.'..%.1e*'•
SEAL HOLE AFTER
DUCT INSTALLATION
WITH RED LEAD
AND OAKUM
�— HOLE IN STRUCTURAL
FLOOR
n "-- DUCT RISER
RISER SUPPORT
HANGER AND SUPPORT DETAILS FOR
LOW PRESSURE DUCTWORK (UP THRU 2" WG)
(VARIOUS METHODS OF ATTACHMENT)
NOT TO SCALE
BEAM
CLAMP
$
CEIUNG
CABINET
FAN
FLOOR
ABOVE
OR ROOF
GRILLE CEILING
EXHAUST
DUCT
BATHROOM EXHAUST FAN DETAIL
- SIDEWALL DISCHARGE
N.T.S.
1/2" MATTE INSULATION (TYPICAL)
24x12" DUCT OPENING
EXTENDING 12" AWAY
FROM UNIT SUPPLYING
TEMPERED AIR.
CEILING
17-
WALL CAP
W/ BACKDRAFT
DAMPER
HORIZONTAL GAS FURNACE DETAIL
FLEX DUCT MAX. 6'-0"
FLEX DUCT SIZE SHALL
MATCH NECK SIZE
CEILING
OPPOSED BLADE
DAMPER
N.T.S.
COLLAR
11 ,
2 f
CEILING RETURN GRILLE \- CEILING DIFFUSER
TYPICAL SOUND ATTENUATION BOOT
NOT TO SCALE
DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES
RECTANGULAR DUCTS
MAXIMUM SIZE
(INCHES)
STEEL
(MINIMUM THICKNESS, NOMINAL)
ALUMINUM
(MINIMUM THICKNESS, NOMINAL)
THROUGH 12
13 THROUGH 30
31 THROUGH 54
55 THROUGH 84
OVER 84
0.022 INCH (26 GAGE, GALV.)
0.028 INCH (24 GAGE, GALV.)
0.034 INCH (22 GAGE, GALV.)
0.040 INCH (20 GAGE, GALV.)
0.052 INCH (18 GAGE, GALV.)
0.020 INCH (N0. 24 B&S GAGE)
0.025 INCH (N0. 22 B&S GAGE)
0.032 INCH (N0. 20 B&S GAGE)
0.040 INCH (N0. 18 B&S GAGE)
0.051 INCH (N0. 16 B&S GAGE)
ROUND DUCTS
MAXIMUM SIZE
(INCHES)
SPIRAL SEAM DUCT
LONGITUDINAL SEAM DUCT
FITTINGS
STEEL
(MINIMUM THICKNESS, NOMINAL)
STEEL
(MINIMUM THICKNESS, NOMINAL)
STEEL
(MINIMUM THICKNESS, NOMINAL)
THROUGH 12
13 THROUGH 18
19 THROUGH 28
29 THROUGH 36
37 THROUGH 52
0.019 INCH (28 GAGE, GALV.)
0.022 INCH (26 GAGE, GALV.)
0.028 INCH (24 GAGE, GALV.)
0.034 INCH (22 GAGE, GALV.)
0.040 INCH (20 GAGE, GALV.)
0.022 INCH (26 GAGE, GALV.)
0.028 INCH (24 GAGE, GALV.)
0.034 INCH (22 GAGE, GALV.)
0.040 INCH (20 GAGE, GALV.)
0.052 INCH (18 GAGE, GALV.)
0.022 INCH (26 GAGE, GALV.)
0.028 INCH (24 GAGE, GALV.)
0.034 INCH (22 GAGE, GALV.)
0.040 INCH (20 GAGE, GALV.)
0.052 INCH (18 GAGE, GALV.)
SUPPLY DUCT
HAND DAMPER
DRAW BAND WITH SIUCONE SEALER
TYPICAL DIFFUSER CONNECTION
(SIDE OF DUCT CONNECTION)
COOLING COIL
DRAIN PAN
SECTION
NOT TO SCALE
AIR HANDLING UNIT OR
AIR CONDITIONING UNIT
ADAPTOR
MINIMUM SIZE 1" OR
`FULL SIZE ON UNIT CONNECTION.
1,1
l-9
"—EXTEND FULL SIZE.
TO INDIRECT WASTE CONNECTION
TYPICAL OF ALL BLOWER COILS
DRAIN PLUG
CONDENSATE DRAIN DETAIL
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
111
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: amer_harry(a)msn.com
Web site: gaiassociates.com
•
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
M 1 -4
-1/4"
r
1 II
1-1 /2"
1 "CW, 3/4"HW, 3/4" HWC
DOWN —�
(( I
J
\-2"
WC -1
"2 "DOWN
-1/4"
1"
L-1
WC -1
3/4"
O
LEE
---3/4"
l �
1 —1 /4"
0
IMB-1
GD -1
1-1/4"
CD
PLUMBING MAIN LEVEL FLOOR PLAN 711111111
SCALE:
NORTH
KEY NOTES: <>
1. PROVIDE AND INSTALL CIRCUIT SLUR WITH FLANKING SHUT-OFF VALVES. BALANCE TO 2.0 GPM.
2. ROUTE 3' VENT THROUGH ROOF AT THIS APPROXIMATE LOCATION. MAINTAIN A MINIMUM OF 10' FROM
ALL BUILDING FRESH MR INTAKES. ROUTE VENTS FROM THE PLUMBING FIXTURES PER THE REQUIREMENTS
OF THE 2012 INTERNATIONAL PLUMBING CODE. COLLECT AND ROUTE CONCEALED TO THE M.
3. ROUTE GAS UNE TO NEW FURNACE AND CONNECT.
4. ROUTE CONDENSATE DRAIN FROM THE CONNECTION AT THE FURNACE WITH A 3/4' COPPER LINE TO THE
NEAREST INDIRECT DRAIN OF ADEQUATE CAPACITY. TERMINATE WITH 2" AIR GAP.
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,I
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: amer_harry@msn.com
Web site: gaiassociates.com
•
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
P1-2
CLEAN -
-OUT
1 -
ACCESS DOOR
-
W/KEY LOCK
LOCATE MIN 1"
ABOVE TRIM
IN–LINE CIRCULATING
PUMP (SEE PUMP SCHEDULE)
AQUASTAT (IF REQUIRED BY
CODE) FOR CONTROL OF PUMP/
("<11 MAY EXTEND AS A
WASTE OR VENT
I I
t
WALL
FLOW
IUI■I
—STRAINER
1
•
REDUCING TEE (OR TEST PLUG
FOR INSERTION OF GAUGE)
UNION
aei i VALVE OR i i ir_ BUTTERFLY vei vc
BALL VALVE LUG VALVE
PLUGGED TEE W/CLEANOUT
FLOOR LINE
NOTE
BALANCE OF PIPING SAME
AS CLEANOUT TO GRADE.
WALL CLEANOUT DETAIL
NOT TO SCALE
•
Li
■I�I■I
DIAL TYPE PRESSURE
GAUGE (0-100 PSIG)
PIG TAIL (TYPICAL)
PLUG VALVE (TYPICAL)
1101111emw
CHECK VALVE
FOR CONTINUATION AND
SIZE, SEE FLOOR PLAN
IN—LINE CIRCULATING PUMP DETAIL
NOT TO SCALE
BASE FLASHING
BY GEN'L. CONT'R.
REFER TO PLANS FOR
SIZE AND LOCATION
WASHING MACHINE BOX
WATER HAMMER ARRESTOR
–WADE MODEL W-5
HOSE
BIBBS
CRIMP EDGE OVER PIPE IN A
NEAT MANNER TO PREVENT
REDUCTION OF EFFECTIVE
VENT AREA.
SHEET COPPER OR LEAD
COUNTER FLASHING BY
PLBG. CONT'R. (TO MATCH
MATERIAL OF BASE FLASHING).
•
•
I REFER TO ARCH. DWGS. FOR
ROOF CONSTRUCTION.
PLUMBING VENT THROUGH FLAT ROOF DETAIL
FROM GAS
SUPPLY
• ,
NOT TO SCALE
MANUAL SHUT–OFF VALVE
WITH AN 1/8" N.P.T. PLUGGED
TAPPING ACCESSIBLE FOR
TEST GAGE CONNECTION TO
BE INSTALLED UPSTREAM OF
THE GAS SUPPLY CONNECTION
TO THE APPLIANCE.
GAS
COCK
GROUND JOINT
UNION
dTO EQUIPMENT/
CONTROLS
6" TRAP
(DRIP LEG)
CAP
GAS CONNECTION TO EQUIPMENT DETAIL
NOT TO SCALE
1/2" HOT
WATER
1/2" COLD
WATER
2" TRAP AND
WASTE PIPE
PROVIDE SWEETFILTER WASHING MACHING
FILTER LINT TRAP ON DISCHARGE OF
WASHING MACHINE HOSE. OWNER SHALL
CLEAN OR REPLACE LINT TRAP PER
MANUFACTURER'S RECOMMENDATIONS.
WASHING MACHINE BOX DETAIL
NOT TO SCALE
CLEANOUT ACCESS COVER (FCO)
3" VENT
4" WASTE
FINISHED FLOOR OR PAVED AREA
WHEN FINISHING AT EXTERIOR OF
BUILDING.
C.I. CLEANOUT
FERRULE & PLUG
SEWER
'�III�III�►
CLEANOUT DETAIL
NOT TO SCALE
INDIRECT DRAIN PIPING
— CLUSTER CLOSELY
TOGETHER
AIR GAP PER NSPC
SECTION 9.3.1
FLOOR
VENT
INDIRECT WASTE
DRAIN OR FLOOR
SINK
TRAP ARM
INDIRECT WASTE DRAIN DETAIL
NOT TO SCALE
WASTE
COLD WATER
SUPPLY
AMTROL THERMAL
EXPANSION TANK
MODEL ST -12 ‘–_–,
HOT WATER OUTLET
TEMPERATURE
& PRESSURE
RELIEF VALVE
TO FLOOR DRAIN
PLUG COCK
CHECK VALVE
RECIRC.
LINE
LINE TEMP.
CONTROL
CIRCULATING —
PUMP (RCP -1)
DRAIN VALVE
SHUT–OFF
VALVE (TYP.)
WATER
HEATER
r
0
4" PVC
FLU E
GAS SUPPLY
PIPE
GAS COCK
UNION
DRIP LEG
f4" THICK CONCRETE
HOUSEKEEPING PAD
a'A, s' '��
s
GAS WATER HEATER DETAIL (WH -1)
ON/ RECIRCULATED LOOP)
NOT TO SCALE
ALL THREAD ROD
NUT (TOP & BOTTOM)
WASHER (TOP & BOTTOM)
CLEVIS HANGER
INSULATION PROTECTIVE
SHEETMETAL SHIELD
TYPICAL CLEVIS HANGER DETAIL
EXTERIOR
WALL
FILL W/ MASTIC
NOT TO SCALE
LINK SEAL
MIN NM I
INTERIOR
WALL
0
„000000 1111111!,111
1" MIN.
PIPE 0.D.
1" MIN.
SCH. 10 STL. OR
C.I. WALL SLEEVE
EXTERIOR WALL SLEEVE DETAIL
NOT TO SCALE
4" PVC
COMBUSTION
INTAKE
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,I
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
■
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: garner_harry@msn.com
Web site: gaiassociates.com
■
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
P1-3
1. SCOPE OF WORK
A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS,
AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM
WHETHER SPECIFIED OR IMPLIED.
B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE
WITH THE 2012 INTERNATIONAL PLUMBING CODE,
ALL LOCAL CODES, AND ALL OTHER REGULATIONS
GOVERNING WORK OF THIS NATURE.
C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL,
EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR
HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO
ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO
MAKE SUCH EXAMINATIONS.
D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR
"APPROVED EQUAL" BY ENGINEER OR ARCHITECT.
2. PERMITS
A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICA—
TIONS AND PAY ANY AND ALL FEES.
3. SHOP DRAWINGS
A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR
EQUIPMENT/FIXTURES TO THE ARCHITECT OR ENGINEER
FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT THREE
SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY
LABELED.
4. DOMESTIC WATER SUPPLY PIPING
A. UNDERGROUND: PROVIDE TYPE "K" SOFT DRAWN COPPER
TUBING WITH BRAZED CONNECTIONS.
B. ABOVE GROUND: PROVIDE TYPE "L" HARD DRAWN COPPER
TUBING WITH 125 PSI SOLDER JOINTS,
COPPER OR BRASS FITTINGS. ALL SOLDER
TO BE "NO LEAD" TYPE.
C. ALL HOT WATER AND HOT WATER RECIRCULATION PIPING TO
BE INSULATED WITH 1" FIBERGLASS INSULATION.
D. ALL COLD WATER PIPING TO BE INSULATED WITH 1/2"
FOAM INSULATION.
PLUMBING NOTES
5. SANITARY/STORM DRAINAGE AND VENT PIPING
A. ABOVE GRADE:
— 2" AND BELOW: SCH. 40 GALV. STL. PIPE WITH SCREWED
ENDS OR SCH. 40 PVC WITH SOLVENT
JOINTS OR DWV COPPER WITH SOLDER
JOINTS. ALL SOLDER TO BE "NO LEAD"
TYPE.
— 3" AND ABOVE: SERVICE WT. CAST IRON WITH NO—HUB
OR BELL AND SPIGOT JOINTS; OR SCH.
40 PVC WITH SOLVENT JOINTS.
B. BELOW GRADE: SERVICE WT. CAST IRON WITH BELL AND
SPIGOT JOINTS OR SCH. 40 PVC WITH
SOLVENT JOINTS.
C. PVC PIPING SHALL NOT BE USED IN AIR PLENUM CEILINGS
AND SHALL NOT CROSS FIRE RATED WALLS, CEILINGS,
OR FLOORS.
D. DRAINAGE PIPING SHALL BE RUN AS STRAIGHT AS POSSIBLE
AND SHALL HAVE LONG TURN FITTINGS.
E. DRAINAGE PIPING 3" SIZE AND SMALLER SHALL RUN AT A
UNIFORM GRADE OF AT LEAST 1/4" PER FOOT, AND PIPING
LARGER THAN 3" SHALL BE RUN AT A GRADE OF NO LESS
THAN 1/8" PER FOOT.
F. ALL VENT PIPING SHALL BE SLOPED TO DRAIN BACK TO
FIXTURES.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
FLASHING OF THE VENT PIPING RUN THROUGH THE ROOF.
6. ALL STUB -INS AND/OR SLAB OR WALL PENETRATION TO BE
PER NATIONAL STANDARD PLUMBING CODE. ALL PIPING
PENETRATIONS OF BUILDING FOUNDATIONS OR FOOTINGS
SHALL BE SLEEVED.
7. PIPE SUPPORTS
A. ABOVE GRADE
ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING
STRUCTURE IN A NEAT AND WORKMANLIKE MANNER.
THE USE OF WIRE AND PERFORMED METAL TO SUPPORT
PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS
SHALL BE AS SPECIFIED IN CHAPTER 8 OF THE NATIONAL
STANDARD PLUMBING CODE.
7. B. BELOW GRADE
EARTH SHALL BE EXCAVATED TO A MINIMUM DEPTH WITH AN
EVEN SURFACE TO INSURE SOLID BEARING OF PIPE FOR ITS
ENTIRE LENGTH.
— INTERIOR: THE PIPE SHALL BE INSTALLED (UNLESS OTHER—
WISE SPECIFIED) A MINIMUM OF 4 INCHES BELOW
THE BOTTOM OF THE SLAB AND SHALL NOT BE
IN ANY DIRECT CONTACT WITH THE CONCRETE
AT ANY POINT.
— EXTERIOR: THE WATER PIPE SHALL HAVE A MINIMUM OF
42" OF COVER AND THE SANITARY WASTE PIPE
SHALL HAVE A MINIMUM OF 24" OF COVER.
8. MISCELLANEOUS
A. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT
ROOF PENETRATION.
B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS.
VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS
AT THE JOB SITE.
C. THE PLUMBING PLANS ARE INTENDED TO BE DIAGRAMATIC
MATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIP—
MENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM
IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL
THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR
SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIP—
MENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL
FIT IN THE AVAILABLE SPACE.
9. TESTING
A. PLUMBING SYSTEMS SHALL BE FLOW AND PRESSURE
TESTED IN ACCORDANCE WITH STANDARD PRACTICE
AND THE INTERNATIONAL PLUMBING CODE.
10. GUARANTEE
A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE
GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE
OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT
PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S
EXPENSE.
B. FOR THE SAME PERIOD, THE PLUMBING CONTRACTOR
SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES
CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK
OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM.
PLUBINC EQUIPVENT SCHEDULE
EQUIPMENT
NO.
DESCRIPTION
(RCP
PUN
P SCHEDULE
S/W
EQUIPMENT
NO.
SERVICE
LOCATION
GPM
HEAD
(FT)
MOTOR
MANUFACTURER & MODEL
OPTIONS—ACCESSORIES
HP
RPM
VOLT.—PH.—CY.
FLA
RCP -1
DOMESTIC WATER RECIRC
MECHANICAL ROOM
2
40
1/3
1750
120-1-60
3.6
TACO — 2400-45S
NOTE — 1
NOTES;
1. PROVIDE WITH STAINLESS STEEL CASING AND IMPELLER FOR DOMESTIC WATER APPLICATION, FLANGED CONNECTIONS, DISCONNECT, AND FLEXIBLE PIPE CONNECTIONS.
NA
PLUBINC EQUIPVENT SCHEDULE
EQUIPMENT
NO.
DESCRIPTION
MANUFACTURER
& CAT. NO.
PIPING CONNECTIONS
NOTES AND REMARKS
S/W
VENT
C.W.
H.W.
IMB-1
ICE MAKER WALL BOX
OATEY — 38574
NA
NA
1/2"
—
C/PV4CTURN BOX. BRASS HAMMER BALL VALVE WITH
WWB— 1
WASHER WALL BOX
GUY GRAIMBH WB200
2"
1-1/2"
1/2"
1/2"
GALVANIZED
DRA ITH SINGLE LEVER HANDLE
AND N
FD— 1
FLOOR DRAIN
JOSAM — 30000—AF
3"
2"
NA
NA
DOUBLE DRAINAGE FLANGE, SURE SEAL TRAP.
FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET
CONNECTION, AND NIKALOY ROUND STRAINER.
WC -1
ADA FLOOR MOUNTED
ONE PIECE WATER CLOSET
FLUSH TANK FLUSHING SYSTEM
KOHLER — K-3946
KOHLER — 4650
KOHLER — K-7637
4"
2"
1"—
ADA FLOOR MOUNTED, ELONGATED BOWL,
OPEN FRONT SEAT, 1.28 GPF WITH MANUAL
TRIP LEVER FLUSH TANK, AND ANGLE SUPPLY
WITH STOP.
GD -1
GARBAGE DISPOSAL
INSINKERATOR — EVOLUTION COMPACT
1-1/2"
—
—
—
SOUND SEAL, TWO GRIND STAGES, 34.6 OUNCE
GRIND CHAMBER, 3/4 HP MOTOR, 8.1 AMPS,
OVERALL HEIGHT 12-1/8", WALL SWITCH.
SK -1
SINGLE COMPARTMENT
STAINLESS STEEL
DROP—IN SINK
ELKAY — LRAD2022
T&S BRASS — B-0851
6-1/2" DEEP BOWL, 18 GAUGE SS, DRAIN,
WHEEL HANDLE ANGLE VALVES, LEVER HANDLES
ON FAUCET, P—TRAP, 3—HOLE PUNCHED FOR
8" CENTERS, AND GOOSENECK SPOUT.
LV -1
ADA WALL—MOUNT
LAVATORY
ZURN — 5354VITREOUS
ZURN — AQUASENSE Z6913
ZURN — Z8946-3—NT
2"
2"
1/2"
1/2"
CHINA, 19"x17" WITH 4" CENTERS,
WHEEL HANDLE ANGLE VALVES, BATTERY
POWERED FAUCET, 0.5 GPM AERATOR, OFFSET
GRID STRAINER, P—TRAP, ADA TRAP, STOP, AND
SUPPLY PROTECTORS, AND WATTRS USG -8
UNDER SINK GUARDIAN MIXING VALVE.
SH -1
ADA DROP—IN TRANSFER SHOWER
AQUATIC — 1363BFSC
2"
2"
1/2"
1/2"
PROVIDE WITH FULLY EQUIPPED ADA PACKAGE
WHICH INCLUDES L -SHAPED GRAB BAR.
L—SHAPED FOLD—UP SEAT, PRESSURE
BALANCING MIXING VALVE, AND HAND—HELD
SHOWER ASSEMBLY PER ADA GUIDELINES. ALSO
PROVIDE STAINLESS STEEL FINISHED FOR
L—SHAPED GRAB BAR, 24" SUDE BAR AND 60"
HOSE FOR HAND—HELD SHOWER ASSEMBLY.
SOAP DISH, CURTAIN ROD, SHOWER CURTAIN,
VINYL FLEXIBLE DAM, REMOVABLE THRESHOLD,
AND BRASS DRAIN. COLOR OF SHOWER TO BE
SELECTED BY ARCHITECT FROM STANDARD
COLORS.
LT -1
TWIN COMPARTMENT LAUNDRY TUB
MOLDED STONE
FLOOR MOUNTED
FIAT — FLTD II
2"
2"PROVIDE
3/4"
3/4"
WITH STEEL ANGLE LEGS WITH
LEVELING DEVICES AND A-1 DECK TYPE FAUCET,
GAS FIRED WATER HEATER SCHEDULE
ITEM
N0.F,
CAPACITY
RECOVERY
090 DEG.
RISE
INPUT
BTU
PER HR.
@SL
OSA/
FLUE
CONN.
ELEC
V/0
MANUFACTURER
& MODEL
OPTIONS—ACCESSORIES
REMARKS
WH -1
60 GAL
154
120,000
4"0/4"0
120/1
A.O. SMITH — BTH 120
NOTE — 1
NOTES:
WITH DISCONNECT, ASME TEMPERATURE AND PRESSURE RELIEF VALVE, CONCENTRIC VENT KIT, AND UL LISTING.
1. PROVIDE
COPYRIGHT 2014 - GARNER ASSOCIATES, INC.
GA,
GARNER ASSOCIATES,
INCORPORATED
ARCHITECTURE AND PLANNING
Harry Garner
Registered Architect
u
4181 County Road 311
New Castle, CO 81647
970-876-2210
CELL 970-379-8345
E-mail: arner_harry(cPmsn.com
Web site: gaiassociates.com
•
REVISIONS
JOB NUMBER
1409
DATE
11-04-14
DRAWN BY
CHECKED BY
SHEET NUMBER
P 1 -4