HomeMy WebLinkAbout5250No. 5250
GARbJJ?IJ)WUJVTY
BUILDING, SANITATION an l PLANNING DEPARTMENT
109 8th Stnzt Suite 303
Glenwood Springs, Colorado 81601
303) 945-8212
Job Address County Road 320, Rifle
Nature of Work Building Permit
Use of Building Single Family Dwelling w /Single Carport
Owner Todd Peters
Contractor Owner
Amomt of permit 3 810.15 Date August 11, 1994
Permit; 491.00
Plan 319.15
Paid $319.15 7 -19 -94
S. Archuleta
Clerk
GARFIELD COUNTY
APPLICATION FOR BUILDING PERMIT
PERMIT NUMBER ....Ca 5Q
Z>please print or type DATE 9Assessor's Parcel #
TO BE FILLED OUT BA l /
FYA •
PLOT PLAN
ADDRESS u,k 30/NOTE: Show easements, property line dimension.
a SUBDIVISION EgL -""- et ' t r'j (!i{pil other structures, specify north, and streei
FILING N LOT # BLOCK #name. For odd shaped lots, or if space is
aTAX SCHEDULE N too small, provide separate plot plan.
LEGAL (SEC /TWN /RNG) 2. / d s / fl to O OF BUILDINGS NOW ON PARCEL
c. NAME 7 O0 pEreieS USE OF BUILDINGS NOW ON PARCEL
W
NAILING ADDRESS 2-50.3 G 4-06•:--
o CITY r h CG'PHONE C.,ZS - VS3 6
NAME 7 7 /C•7 / 2'
w ADDRESS CITY
o
u ADDRESS o
CITY 2" Ft S 7_)%y rS r
o PHONE LICENSE #
CLASS OF WORK
NEW y ALTERATION ADDITION _p ;71 9 4 0 a
DEMOLISH REPAIR MOVE _
rr
MOBILE HOME (make /model)1
S.F. OF BUILDING 2/01 S.F. OF LOTNAttox eisr_'r / /f0 ft;'.
OF FLOORS HEIGHT
i OF FAMILY UNITS r OF BEDROOMS w '-' 1 Tf+
INTENDED USE OF BUILDING i
GARAGE: SINGLE DEL CARPORT: SINGLE VDBL __FRONT PROPERTY LINEFIREPLACE
DOCUMENTS ATTACHED STREET NAME /ROAD NUMBER
WATER SUPPLY LJ L CHECK IF CORNER LOT
DRIVEWAY PERMIT O JET/ A DESCRIPTION OF WORK PLANNED
SITE PLAN r'
BUILDING PLANS
SANITARY SEWER CLEARANCE I hereby acknowledge that I have read this
ON SITE SEWAGE DISPOSAL PERMIT Q 71:'':1 ilt-'application and the above is correct and I
OTHER DOCUMENTS (specify)agree to comply with all county ordinances
and state lards 1at.ing building constructive
i
S
FOR OFFICE USE ONLY
VALUATION _F'hDOD HAZARD
PERMIT FEE $ PLAN CHECK FEE $CERTIFIED BLDG ELEVATION
TOTAL, FEE OO.SCHOOL IMPACT FEE $ ..2Oe7 SPECIAL CONDITIONS
DATE PERMIT ISSUED
ZONING DISTRICT PROBLEMS WITH PERMIT
TYPE OF OCCUPANCY
TYPE OF CONSTRUCTION _N ADDITIONAL INFORMATION NEEDED
S.F. OF BUILDING f ,3c VI F. OP LOT 4, 5
Z MAX. HEIGHT ',bit VO LiGROAD CLASS. 'c,^,L /CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
SETBACKS FROM PROPERTY LINE: FRONT GO -i.OR ENGINEER
REAR z4 :30DFf.j- RIGHT=ICI: )80 p 4- LEFT = 5:z7(5 fi
OFF STREET PARKING SPACES
REQUIRED Q-
APPROVED' i deilL, / !Z J / - APPROVED: IM C 73i y 7 - AP ( j r
BIILDI G E pNT DATE PLANNING DEPARTMENT DATE
GARFIELD COUNTY BUILDING AND PLANNING
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit
application and expedite the issuance of a permit it is important that
complete information be provided. Adequate and complete information
will prevent delays in the plan review process. Reviewing a plan and the
discovery that required information has not been provided by the applicant
may result in the delay of the permit issuance and in proceeding with
building construction. The owner or contractor may be required to provide
this information before the plan review may proceed. This causes delays
because other plans that are in line for review may be given attention
before the new information may be reviewed after it has been provided to
the Building Department.
Please review this document to determine if you have enough information
to design your project and provide adequate information to facilitate a plan
review. If you do not, it may be helpful to obtain a book titled 'Dwelling
construction under the Uniform Building Code. This book is available to
you through this department at our cost. Also, please consider using a
design professional for assistance in your design and a construction
professional for construction of your project.
To provide for a more understandable plan in order to determine
compliance with the building, plumbing and mechanical codes, applicants
are requested to review the following check list prior to and during design.
Applicants are required to indicate appropriately and to submit completed
check list at time of application for a permit:
1
1.Is a site plan included that indicates the distance of the proposed
building or addition to property lines, other buildings, set back
easements and utility easements?
Yes No 1) Not necessary for this project a>
2.Does the site plan include the location of the I.S.D.S. (Individual
Sewage Disposal System) and the distances to property lines, wells
on subject property and adjacent properties) , streams or water
course
Yes _Z__No ____a) Not necessary for this project 2)
3.Does the site plan indicate the location and direction of the County or
private p° ad accessing the property?
Yes _.No 1) Not necessary for this project 2)
4.Do the plans include a foundation plan indicating the size, location
and spacing of all reinforcing steel in accordance with the uniform
building, code or per stamped engineered design?
Yes No 1) Not necessary for this project 2)
5.Do the plans indicate the location and size of ventilation openings for
under floor crawl spaces and the clearances required between wood
and ear
Yes No 1 ) Not necessary for this project _____(2)
6.Do the plans indicate the size an location of ventilation openings for
the attic, roof joist spaces and soffits?
Yes _IC__No a, Not necessary for this project 2)
Do the plans include design loads as required under the Uniform
Building code for roof snow loads, (a minimum of 40 pounds per
square foot in Garfield County) floor loads and wind loads?
Yes No _ M _ u ) Not necessary for this project a)
8.Does the plan include a building section drawing indicating
foundation, wall, floor and roof construction?
Yes _No a) Not necessary for this project 2)
9.Does the building section drawing include size and spacing of floor
joists, w11 studs, ceiling joists, roof rafters or joists or trusses?
Yes No 1) Not necessary for this project 2)
10. Does the building section drawing or other detail include the method
of positive connection of all columns and beams?
2
Yes No _ an Not necessary for this project 2)
11. Does the plan indicate the height of the building or proposed addition
from the highest point of the building or addition measured at mid
span between the ridge and the eave down to existing grade cglitours?
Yes No i) Not necessary for this project 2)
12. Does the plan include any stove or zero clearance fireplace planned
for installation including make and model and Colorado Phase II
certifications or phase II EPA certification?
Yes _____No Not necessary for this project 2)
13. Does the plan include a masonry fireplace including a fireplace
section indicating design to comply with the Uniform Building Code
Chapter 37?
Yes No u) Not necessary for this project _ a,
14. Does the plan include a window schedule or other verification that
egress /rescue windows from sleeping rooms and /or basements
comply/with the requirements of the Uniform Building Code?
Yes 2___
No _ Not necessary for this project 2)
15. Does the plan include a window schedule or other verification that
windowfprovide natural light and ventilation for all habitable rooms?
Yes _No a) Not necessary for this project 2)
16. Do the plans indicate the location of glazing subject to human impact
such as glass doors, glazing immediately adjacent to such doors;
glazing adjacent to any surface normally used as a walking surface;
sliding glass doors; fixed glass panels; shower doors and tub
enclosgr'es and specify safety glazing for these areas?
Yes No cu Not necessary for this project 2)
17. Is the location of all natural and liquid petroleum gas furnaces,
boilerynd water heaters indicated on the plan?
Yes _No ___ __n) Not necessary for this project 2)
18. Have two (2) complete sets of constructions drawings been submitted
with t4 6 application?
Yes No 1) Not necessary for this project a,
19. Have you designed or had this plan designed while considering
buildir and other construction code requirements?
Yes No 3)
3
r
20. Does the plan accurately indicate what you intend to construct and
what will receive a final inspection by the Garfield Building
Department?
Yes No 3)
21. Do you lnderstand that approval for design and /or construction
chang e are required prior to the application of these changes?Yes No 3)
22. Do you understand that the Building Department will collect a "Plan
Review" fee from you at the time of application and that you will be
required to pay the "Permit Fee" as well as any "School impact" or
Septic system " fees required, at the time you pick up your building
permit"
Yes __ __No 3)
23. Are you aware that you are required to call for all inspections
required under the Uniform Building Code including approval on a
final
iinpection prior to receiving a Certificate of Occupancy and
occup cy of the building?
Yes No 3)
24. Are you aware that the person signing the Permit Application whether
the "Owner ", "Agent of the Owner ", "General Contractor ", "Contractor"
or otherwise, signing the application is the party responsible for the
project omplying with the Uniform Codes ".
Yes _L.No 3)
I hereby acknowledge that I have read, understand and answered these
questions accurately to the best of my ability.
9 Ft
signature d
Phone: 425 (days);j 8 1-,-+-evenings)
Project Name:7704,0 ocr ,eS 42 O Z cecf /ohJ
Project Address: 46 *-C 2,C 5 'or 7
4
Notes:
1)If you have answered "No" on any of these questions you may be required to provide this information at
the request of the Building Official prior to beginning the plan review process. Delays in issuing the
permit are to be expected. Work may not proceed without the Issuance of the permit.
2)if you have answered "Not necessary for this project" on any of the questions and it is determined by
the Building Official that the information is necessary to review the application and plans to determine
minimum compliance with the adopted codes, please expect the following:
A.The application may be placed behind more recent applications for building permits In the
review process and not reviewed until required information has been provided and the
application rotates again to first position for review.
B.Delay in issuance of the permit.
C.Delay In proceeding with construction.
3)If you answered "No" to this question the circumstances described in the question could result In a "Stop
Work Order" being issued or a "Certificate of Occupancy" not being issued.
PerApp01.94 Effective May 1, 1994
5
A
r
No. 5250
aARFmoctowyni
stave fq SANTA 7XXNasiftAPO i jnfl, 7Jgj
hle! 1 &,ea, Soho 30S
wrOlood firings, ri, Colobet
MS) 0604212
lob Adds 6 .p County Road 320, Rifle
Nolan: orwo&B,il Perm4r
uaesr Single Family Dwelling w /Single Carport
O Todd Peters
Corumew Owner
Aaw 810.15 ui4 August 11, 1994
Permit; 491.00
Plan 319.15
Paid $319.15 7 -19-94
S. Archuleta
rank
GARFIELD COUNTY
APPLICATION FOR BUILDING PERMIT
j QPERMITNUMBER ..5.q
please print or type DATE S'if- / p 5tAssessorsParcel #
TO BE FILLED OUT PI,C PLOT PLAN
DDRESS P Jof0 NOTE: Show easements, property line dimension:
SUBDIVISION :,Jf". .... t' all other structures, specify north, and street
PILING N LOT N BLACK # _ name. For odd shaped lots, or if space is
7'AX SCHEDULE qa
LEGAL SEC TWN RNG
tuu small, provide separate plot yIen.SE Gt)Or BUILDINGS NOW ON PARCEL
F4 NAME Tao Z USE OF BUILDINGS NOW ON PARCEL
W MAILING ADDRESS .2_. •L 006-.
CITY JI PHONE G,u - S/3' G
a NAME 4'6(C-dc?-2
0 ADDRESS CITY 257.11 -x-ser
7 //
Sin
w
NAME fGlt Fe' ft C 3yr c - i 3nDORESS
S CFcur2s•! FL
p 7agI °NONE _____„_ LICENSE N ^y ( - C
f CLASS or WORK
7
NEW y ALTERATION ADDITION k -eV-1% . 79DEMOLISHREPAIRMOVE _
MOBILE HOME (make/model)my 7 /S
S.F. OF BUILDING 2/01 S.F. OF LOTfi1Igp '7nm.; /.l -OF FLOORS HEIGHT
OF FAMILY UNITS I P OF BEDROOMS I
INTENDED USE OF ,BUILDING
GARAGE: SINGLE DIM CARPORT: SINGLEVDBL FRONT PROPERTY LINEFIREPLACE
DOCUMENTS ATTACHED STREET NAME /ROAD NUMBER
WATER SUPPLY alet CHECK IF CORNER LOT _
T
DRIVEWAY PERMIT ex )ST/ n/ 1-DESCRIPTION OF WORK PLANNED
SITE PLAN
BUILDING PLANS
SANITARY SEWER CLEARANCE I hereby acknowledge that I have read this
ON SITE SEWAGE DISPOSAL PERMIT 0 7:i.+-ii -r application and the above is correct and I
OTHER DOCUMENTS (specify)agree to comply with all county ordinances
and state ia s ating building construction
I•
SiSNATURE
6
VALUATION ` C Sts
FOR OFFICE
FLOOD
ONLY
PERMIT FEE $PLAN CHECK h'L'E $ 7i7 CERTIFIED BLDG ELEVATION
7V7'AL FEE IJ SCHOOL IMPACT FEE $ }[OG> -" SPECIAL CONDITIONS
DATE PERMIT ISSUED
ZONING DISTRICT .PROBLEMS WITH PERMITE
TYPE OF OCCUPANCY _ « e
TYPE OF CONSTRUCTION ADDITIONAL INFORMATION NEEDED
S.F. OF BUILDING 1319 OF LOT ( S
MAX. HEIGHT' 2 {I( to jf .ROAD CLASS. 'r1yt. ta CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
SETBACKS FROM PR PERTY LINE: FRONT GO F.t.OR ENGINEER
REAR =L{J: 3VDf7- RIGHT =4:nat ri LEET'5:z7ttF4.1"
OFF STREET PARKING SPACES REQUIRED
pAPPROVED •I . / V Y APPROVED: Air. 73.44 7
WI iii r T DATE PLANNING DEPARTMENT DATE
r'
INSPECTION WILL NO DE MADE UNLESS
THIS CARD IS PAP 4 ON THE JOB
24 HOURS NOTICE R'..,,D FOR INSPECTIONS
BUILDING PERMIT
FI LD COUNTY, COLORADO
Date Issued .( Zoned Area Permit No
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of the
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction of the above described structure, the permit may then be revoked by notice
from is rjt Sing ?sureitPrad IM / Ep, IAT LY jECO N
ger—
D,
tie
0 r
Address or al Descript'
Owner /d Contractor IV / w+
p e
Setbacks Front Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning Roof Covering
Electric -Final (by STATE inspector)
Footing cf - 9- ' /'f v 3 j Y`1 C,--
Foundation 1/- i - I* 4,-.,,)
Plumbing - Underground 4"->y,-' rr J
Gas Piping Heating Ventilation
Frame 2 8 9 f 49'1 Insulation // _1,2 - 74. fl
Plumbing -Rough 11 -.-23 -`L Wt-"—Drywall i it- I S i/ .
Electric - Rough 9(# v,-a (by STATE inspector)Final 5 --9-oa
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING —
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945 -8212 10 9 8th Street,County Courthouse,Glenwood Springs, Colo.
APP ' V ED DO NOT DESTROY THIS CARD
Date B Li of • i.-
IF PLACED OUTSIDE - rOVER WITH CLEAR PLASTIC
0 ItU0 ,.0 17 up,dUw—ai In '
O 0
yy 8 G v.:
y CI:/N y 0 6 g L OTC
GQ N
Ln
A N v 0
mil O C 8 0 OSri
a .a .
i w ai AO o G
444=1 CIS a.oOwl" 123
CI esS
V b
OCC vtN
g
rn
kt c a
Nos c c 8 uyo
U ai
I j ,,
a w .
e a a 0
oU C °bA u
V o w ..aim a 4 EOoMG. U in p
w.
h 0 0 U N we
ge i E 4 p C m O O
b ti U d O
kr)rte 0• -.a t.0 b 4 es
00 eo sics as e , O 0 O 46 cip-
M a eo o v d 0 R CU u
a c41
6 cn a> o
O
w„
Z Z a e g.5 w CJ FG U Pal 4 o 0