GARFIELD COUNTY
BUILDING, SANITATION and PLANNING DEPARTMENT
109 8th Street Suite 303
Glenwood Springs, Colorado 81601
(303) 945-8212
JobAddress ----=1~7-=0--=E=a=s:.:t:_:T~a=m=a=r=a=c=k=-C=c=c::::l=e~,--=S=a=d=d=l=e=b=a=c=k:_V=i=l=l=a~g=,e='-'-B==a=t=t=l=e=m=e=n=t:_:M=e=s=a:__~------
Nature of Work Bnil 4in~ Permit
Use of Bui I ding _ _,,I,,n,,,s_,,t"'a"'l"'l'-'-Ma"""n'-'u=-'f'-'a'"c"-'t"'u"'r"'e"'d"-'H",o"m=e~s ___ __c ______________ ~-------
Owner ------,----"G~e,,n~e'-"&'-'B~e~t~to.1_'~S~e"-'t"'l~1 __________________ ----~--------
C< 1tractor ~--~B~a~t~t~l~e=m=-e=n=-t~M=e=-s=-a=-J=l=-om=e-=s_,_,----=I-=n:.:c:.:•--------------------~------
An-,ount of Permit: $ -~2~0~7~. 9~0~-~~~--
Permit: 12.6. 00
White -Treas.
Canary -Office
Pink -Applicant
Gold -Duplicate
Plan 81.90
Date: ---=S-=e~p-=t-=e=m~b-=e~r---=-3~0"--~1~9~9~3----------~
S. Archuleta
Clerk
GARFIEJ.)J COUN'l'Y
AI'PLICA'l'ION FOR BUILDING l'EllNlT
PElU!IT NUMBER fq If
please f)rint or type DATE September L 199:931£3
PLOT PLAN Td BE. FILLED OUT BY Al'l'LICANT
---1'DDRESS 170 East Tamarack r.i rclA
....1 SUBDIVISlDN Saddleback Village
2J FI LING II L07' II 14 BLOCK If _l2_
W 7'AX SCHEDULE # ....1
LEGAL (S/','C/TWN/RNG)
NMIE Gene & Betty Seth
MAILING /ID DRESS P .0. Box 6000 -~~---~~---~~~-
CIT l' Battlement Mesa Pl/ONE 285-7331
~ ri::: NA!1E Battlement Mesa Homes, Inc.~
~ ~ ADDRESS P .0. Box 6000 CITY Battlement Me a
NAl'.IE Battlement Homes. Inc.
ADDRESS ..E.....O...__,,_.~-"'"-'-"'"------------
CITY Battlement Mesa
Pl/ONE 285-7331 LICENSE /1
CLASS OF llOPJ{
·1nv xxx
I JENO LISI/
llL7'ERllTION
REPllIR
ADD LT ION ----
MOVE ----
NOBILE 110/IE (make/e1odel) 9817 Skyline "Pawnee"
S.F. OF BUILDING 1207 S.F. OF LOT 6823 -----11 OF FLOORS 1 llELGl/T 15'
-~-------~~------1 ! or FllNILl' UNITS 1 #. OF BEDROOMS 3
-~--
rN7'ENDED USE OF BUILDING Single family residence
GllRllGE: SINGLE DBL..!f_ CllRPORT: SL NG LE DBL
I~ Attached Garage
DOCUMENTS ATTAC!IE!l ·------------'=====--===='---------
hll\1'ER SUPPLY Battlement Mesa Metro DiStrict
DRIVEWAY PERMI7'
SITE PLAN
N File
SANITARY SEWER CLEARllNCEBattlement Mesa Metro Dist
ON SI7'E SEWllGE DISPOSAL PERMIT
FOi\ OFFICE
VAL.Ull 7'ION Io, 0 't''l. :J (
PERMIT FEE f;u """PLAN Cl/ECK FEE $ 'i"t' ea
7'07'AL FEE $ 2CJ7. 'fO SCHOOL L/11'/ICT FEE $ /"' '/
Dll1'E PERMLT ISSUED
ZONLNG DIS1'RICT V/)
-~,,.--,,-------------1 'Y PE OF OCCUPANCY f<.-J, ..t::J_-/
TYPE OF CONS7'RUCTI-O~N~.:z:~='-j\/~_--. _-_~ _-_-_-_-_-_-_-_-_-_-_-_---=-
S. F •. OF BUILDING /("OL S.F. OF L07'
MllX •. llEIGllT f:Z' ROAD CLASS.
SETBllCKS FROM PROPER7'l' LINE: f'RONT
llEAR RIG//T LEF1' ----------
0 f' F STREET PARKING SP!ICES REQUIRED _7' ____ _
NO'l'E: Show easen1e11ts, property line dimension
all other structures, specify north, and stree
name. F'oL· odd shaped lots, oi· if space is
too small, provide separate plot plan .
/I OF BUILDINGS NOW ON PllRCEL --~0 _____ _
USF. Of' BUIL.DINGS NOW ON P!IRCEL n a -=~-----
170 EAST TAMARACK CIRCLE
FRONT PROPERTY LINE
STHEET Nll/IE/ROIID NUMBER East Tamarack Circle
Cl/ECK IF CORNER LOT
DF.SCRIP7'ION OF WORK PLANNED Set modular'
new foundation, site built garage. walks.
drive and landsca e.
L hereby acknrndedge that I have read this
a_qJ?lication and the above is correct and I
agree to comply il"i th all county ordinances
gulating building constructic
FL.OOD llllZ/IR/) ----------------
CERTLFLED BLDG ELEV!ITION
SPECIAL CONDITIONS
PRODIBMS fyH'll PERMIT
llDDITION/lL INFORM!ITION NEEDED --------
CEll7'Il'lBD Bl' COLORllDO llEGISTERED LAND SUllVEYO!
OR ENGINEER
I
owNER B.rJ. f'!J1 1rt'1'"".J _____ LocAnoN /Zo fi"· rq111711-?CN o/f.
CON'r!lACTOR a.o. /10 /'H-'
PERMI'r # ___ _
'.!'Im FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR llAY NOT COMPLY WI'rH
'l'HE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED I'l'EMS
BEFORE BEGINNING CONSTRUCTION, ALL REFERENCES ARE 1988 EDI'l'IONS OF THE CODES·
THESE I'l'EMS ARE REQlJIREMEN'l'S FOR R-3 OCCUPANCIES ONLY (ONE AND TWO FAMILY
DWELLINGS) AND ARE NO'l' ALL INCLUSIVE OF THE CODE REQUIREMENTfl, BUT ARE MEANT AS
A GUIDE 'l'O SOME OF THE 11081' OFTEN ENCOUN1'ERED QUESTIONS RELATED 1'0 CODE
REQUIREMEN1'S, 'rl!E APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT U!E BUII,DING
SI'l'E DURING CONS'rRUCTION. FOR ANY REQUIREMENTS OF 'rHE NATIONAL ELECTRICAL CODE
CONTAC'l' THE COLORADO ELECTRICAL INSPEC'.l'OR.
'.!'HERE SHALL BE A FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES
WHEN COMPLETED AND READY FOR OCCUPANCY AND USE -UHC SEC. 305 (d).
1. Concrete for foundations and load bearing slabs is required to be 3000 psi
in 28 days -UBC Chapter 26. Mortar and grout shall be in accordance with
UHC Chapter 24 & Table 24-A and 24-H.
2. Masonry units, mortar, and grout shall be protected during cold weather in
accordance with UBC Sec. 2404 {c). Concrete shall be protected during cold
or hot weather in accordance with UBC Sec. 2605 (f) and (g).
3. Minimunl concrete and/or masonry foundation reinforcement requirements are
shown on the attachment. (Note: these minimums apply only if a foundation
soils investigation is not performed and the soils are assumed to have an
expansion index of 20 or less and footing loads less than 2000 lbs/linear
foot -UBC Sec. 2904 (a) and (b) and Sec. 2906.
4. Foundation frost protection is 30" froin finished grade to top of footing -
UBC 2907 (a).
5. Foundations shall extend a min. of 6" above finished grade -UBC 2907 (d).
6. Provide for the control and drainage of surface water awa:y from the building
-UBC 2907 (f).
7. Foundation walls enclosing a basement below grade shall be damp'-proofed on
the exterior with approved materials -UBC Sec. 1707 (d).
B. Foundation plates or sills shall be redwood or pressure treated wood (UBC -
2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia
bolt~ embedded at least 7" into concrete or masonry, spaced not 1nore than
6 feet apart, min. of 2 bolts per piece and wi·thin 12" of each end of piece
-UBC 2907 (f).
9. Exterior concrete or masonry piers shall extend 8" min. above grade unless
the posts or columns which they support are treated or decay resistant wood.
Columns and posts located in basements shall be supported by concrete piers
or metal pedestals extending 6" min. above earth and 1-" min. above floor
10.
11.
12.
13.
14.
15.
16.
17.
10.
19.
20.
unless treated or decay resistant wood -UBC Sec. 2516 (c) 4.
Manufactured trusses, and manufactured joists and beams (i.e. •rJI/Micro-
Lams, BCI/Versa-Larns, Glu-Lams, etc.), shall be sized and installed in
accordance with the manufacturers requirements.
Wood joists or floor beams located closer than 18" or wood girders closer
than 12" to the ground in crawl spaces shall be treated or decay resistant
wood -UBC Sec. 2516 (c) 2.
Girders supported by masonry or concrete shall have 1/2" air space at top,
sides, and ends unless treated or decay resistant wood -UBC Sec. 2516 (c)
5. Ends of beams and girders shall have min. 3" of bea.ring on inasonry or
concrete -UBC Sec. 2517 (c).
Floor joists under and para,llel to bearing partitions shall be doubled UBC
2517 (d) 5.
Floor joists require full depth solid blocking and must lap a min. of ]"
over bearing supports -UBC 2517 (d) 3.
Beams, roof rafters, and ceiling and floor joists shall be supported
laterally in accordance with UBC 2506 (h).
Columns, posts, beams, and girders shall have positive connections provided
to ensure against both uplift and lateral displacement -UBC Sec. 2516 (m).
Ends of floor joists shall have 1 1/2" min. bearing on wood or metal-and no
less than 3" on concrete or masonry -UBC Sec. 2517 (c) and (d) 2.
Notches on the ends of floor joists -max. 1/4 joist depth. Bored holes not
within 2" of top or bottom of joist and hole diameter no larger than 1/3
depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not
located in middle 1/3 span -UBC Sec. 2517 (d) 3.
Floor joists and/or roof rafters are insufficient for the span -UBC '.['able
25-V-J-1 and UBC Standards.
Roof live load (Snow load) shall be 40 psf below 7,000 feet elevation -UBC
Sec. 2305 (d)-dead loads shall be as required in usc·sec. 2305.
''! ,'.! ·Ir
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
,44_
Floor live load shall be 40 psf -UBC Sec.2304 (a) and Table 23-A~l -dead
loads shall be as required in UBC Sec. 2304.
Basic wind speed shall be 80 mph -UBC Sec. 2311.
Headers over wall openings 4' wide or less shall be doubled 2" framing
lumber on edge. Over 4' wide the header shall be sized for the span -UBC
Sec. 2517 (g) 5.
Bearing walls supporting two floor loads are required to be a min. of 3" x
4"or 2"x 6" studs with a max. spacing of 16" on center-USC Sec. 2517 (g) 1.
Wood studs n1ay be cut or notched to a depth not exceeding 25% of width in
exterior walls and bearing partitions and not exceeding 40% of width in non-
bearing partitions -UBC Sec. 2517 (g) 8.
Wood studs may have bored holes no greater in diameter than 40% of stud
width, 60% of widt.h o.E doubled studs (but not inore than 2· successive doubled
studs). No holes shall be bored nearer than 5/B" to edge of stud -UBC Sec.
2517 (g) 9.
Wall bracing required both sides of each corner and every 25 lineal feet -
the braced panel nlust be a min. of 48" in width perpendicular to studs -UBC
Sec. 2517 (g) 3.
Approximate ntin. insulation values are R-19 walls, R-25 roofs, and R-11
floors over unheated space -see plans for more specific requirements -
"Colorado Energy Conservation Standards."
Foam plastic insulation shall be separated from the building interior,
including attics and crawl spaces, in accordance with UBC Sec. 1712. Other
insulation (including duct and plenwn insulation and coverings per UMC
Chapter 10) including facings shall meet the require1nents of UBC Sec. 1713.
Masonry and stone veneer units (5" max. in thickness) shall have min. size
of No. 22 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and
spaced to support not more than 2 sq. ft. of wall area but not more than 24"
on center horizontally. When applied over stud construction, the studs
shall be max. of 16" on center. Approved building paper must be applied
over the sheathing or studs -UBC Sec, 3006 (d).
Ceiling height is required to be 7'6" in all rooms except kitchens, halls,
bathrooms, and storage areas which may be 7'0" min. -UBC Sec. 1207 (a). ---
Min. stairway headroom clearance is 6'8" -UBC Sec. 3306 (p).
Mi~. stairway width is JG" -UBC Sec. 330G (b) and min. landing dimension
in the direction of travel must also be 36" -UBC Sec, 3306 (g).
Stairways m.in~ run 9"; max. rise 8"; max. variation in rise and run 3/8" -
UBC Sec. 3306 (c).
Enclosed usable space under interior and exterior Htairways shall be
protected on the enclosed side as required for one-hour fire-resistive
construction UBC Sec. 3306 (m). Fire stops shall be provided in
accordance with UBC Sec. 2516 (f) 2c.
Stairway handrails: min. height 34"; max. height 38"; handgrip portion shall
be not less than 1 1/2" nor more than 2" in x-section dimension. Min. of
one handrail required on all stairways with more than three risers. Min.
1 1/2" space required between wall and handrail -UBC Sec. 3306 (j).
Guardrails of 36" min. height shall be installed at unenclosed floor
openings and open sides of stairways, landings, ramps, dflcks or porches more
than 30" above grade or floor below. Open guardrails shall have a pattern
such that a sphere 6" in dia. cannot pass through -UBC Sec. 1711.
Under-floor (crawl space) cross ventilation is required equal to 1 sq. ft.
for each 150 sq. ft. of under-floor area -UBC Sec. 2516 (c) 6.
Under-floor areas shall be provided with a min. 18" by 24" access opening -
UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under-floor
area -UMC Sec. 709.
All sleeping roo1ns below the fourth story without a door opening to the
exterior shall have at least one operable window that meets the following
requ.irements: MINIMUM clear open.lug: 5. 7 sq. fto
MAXIMUM sill height: 4 4"
MINIMUM net clear opening height: 24" (x34 1/4" == 5. 7 sq.ft.)
MINIMUM net clear opening width: 20" (x41" == 5.7 sq. ft.)
This also applies to basement sleeping rooms -UBC Sec. 1204.
Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors
and adjacent to doorways, and glazing in windows .located within 18"
vertically of a walking surface) shall be safety glazed or protected.
Glass in sloped glazing (more than 15 from the vertical} and skylights
shall meet the requirements of UBC Chapter 34. Skylights and roof and wall
panels of light-transmitting plastics shall meet the requirements of UBC
Chapter 52.
Provide combustion air for fuel burning equipment per UMC Ch.apter 6.
Pressure relief valves and/or combination pressure/temperature relief valves
shall be provided with a drain line to a floor drain with min. 1" air gap
.....,._.; ..
i:i
or extended to the exterior of the building -UPC Sec. 1007.
Domestic dishwashing 1nachines shall not be directly connected to a drain or
waste disposer without the use of an approved airgap -UPC Sec. 608 {d).
Fuel burning appliances shall not be located in any room used or designed
to be used as a sleeping room, bathroom, or closet or any enclosed space
opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless
listed for such use).
Appliances (including space heating and water heating equipment) shall be
accessible for repair and removal in accordance with the UMC.
LPG fueled appliances shall not be installed in a pit, under-floor (crawl)
space, or base1nent -UMC Sec. 504 (f).
Appliances located in a garage (or in an enclosure opening into a garage)
shall be located out of the normal path of vehicles or protected from
damage. Any portion of the appliance creating a flame, spark or glow shall
be installed a min. of 18" above the garage floor -UMC Sec. 508.
Each water closet stool shall be located in a clear space not less than 30"
in width and 24 11 in front of stool -UBC Sec. 511 (a).
Toilet rooms without operable windows shall be equipped with an exhaust
system ducted to the exterior -UBC Sec. 1205 (c).
Showers and Tub/Shower enclosures shall have a smooth, hard, nonabsorbent
surface to a height of 70 11 min. above the drain inlet -· UBC Sec. 510 (b).
Water-resistent gypsum board shall not be used over vapor barriers, in
saunas or steam rooms, or on ceilings -UBC Sec. 4712.
Attic access opening of not less than 22" by 30 11 is required -UBC Sec. 3205
(a). 30" by 30" if mechanical equip. in attic space -UMC Sec. 708.
Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150
of the area of the space ventilated. The area may be 1/300 if provided
equally at lower and upper portions of the space with min. 3' vertical
separation of locations -UBC Sec. 3205 (c).
55. Garage side of common wall between living space and garage shall be finished
with materials approved for one-hour fire-resistive construction. 'rhis also
applies to ceilings and bearing walls if living space above the garage.
Self closing n1in. 1 3/8" solid, tlr,ht fitting door ls required between house and
r.arai.;e UBC 503 (d) 3.
56. Electrically wired, interconnected smoke detectors are required in all
sleeping room access area.s, near the top of stairways in upper levels, and
near the bottom of stairways to basements -UBC Sec. 1210 {a).
57. Wood stoves and factory built chimneys, and manufactured fireplace units and
venting systems shall be installed in accordance with the manufacturers
listing requirements and inspected during installation u.M:c Chapter 9 and UBC
Chapter 37.
5 B. Masonry and concrete fireplaces and barbecues shall meet the requirements
of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any
structural load other than its own weight unless designed as a supporting
member -UBC Sec. 3703 (a).
59.
60.
COPIES OF 1'HE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items
above or below are available upon request).
Excavations, fills, foundations, and retaining walls -UBC Chapters 23 and
29.
Retaining walls -UBC Sec. 2308 (b) and 2907 (g) 4.
Roof coverings and drainage UBC Chapter 32 (Roof drains sized in
accordance with UPC Appendix D).
Roof sheathing -UBC Sec. 2516 {i).
Wood combined with (supporting) masonry or concrete -UBC Sec. 2515.
Floor sheathing -UBC Sec. 2516 (h).
Wiring in plenums -UMC Chapter 10 and NEC.
Fire and draft stops -UBC Sec. 2516 (f).
Nailing requirements for connecting wood 111embers -UBC Sec. 2516 (j).
Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish
chutes -UBC Sec. 1706.
Exterior wall coverings and exterior weather protection -UBC Sec. 1707 (d)
and 2516 (g).
interior and exterior
Manufactured wall and
shall be installed in
Interior application of gypswn wallboard and
application of lath and plaster -UBC Chapter 47.
ceiling covering systems (simulated stucco, etc.)
accordance with manufacturers requirements.
Landings and floor level at doors -UBC Sec. 3304 (i).
Cross connection control and back flow prevention -UPC Sec. 1002 and 1003.
Treated Wood Foundation Systems -UBC Standard 29-3.
INSPECTION WILL NOT BE MADE UNLEt~
THIS CARD IS POSTED ON THE JOB
24 IIOUllS NOTICE IWQUIItED FOR INSPECTIONS
BUILDING PERMIT
GA~.~!ELD COUNTY, COLO_RAD8ct I
Dal.c IssueFJ/30/.'J...J.zoned Area ....................................... Per011l No ..................... / ..
AGREEMENT
···-·
ith Jn considcrntion of the issuance of this perniit, the applicant hereby agrees to co1nply w
all laws and regulations related to the zoning, location; construction and erection of t
proposed structure for which this pern1it is granted, and further agrees that if the abo
said regulations nre not fully con1plicd "'ith in the zoning, location, erection a
construction of the above described s1ructure, the per1nit 111ay then be revoked by not
be
ve
ncl
ice
~:'~r:.J'SfAt'tglnm1 and ME I TELYil•COMENULLANDVOI D,
c:2:~~1.1tt: '(d,~ttY s eif-h ff_(.
Sclhacks Front Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
Zoning
Footing
F oundaHon·
Plumbing-Underground
Gas Pi11ing I . ,-/ -.-i 'i
-I ·...-I
Frame @.a--.-) :Z • J, 0° 73
Pluinbing-Rough
Electric-Rough
(by STATE inspector)
INSPECTION RECORD
Roof Covering
Elec!ric-Final (hy STA TE inspector)
Heating Ventilation
Insulation
Drywall
li'inal
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR AilOVE GROlJND.
THIS PERMIT IS NOT TRANSFERA!IU;
Phone 945-8212 10 9 8th Street, County Courthouse, ))U. GleJT\VOO<l Springs, c(
~.~J;/JOVE~m~e;;;;;; THIS CAJW ~LACED OUTSIDE -COVER WITH CLEAR PLASTIC
i i.
'
.
· ....
-~
'
'
'
'. ,. ·1. . .. ..• •"·· ;·;·; .
2195
No change in the character or occupancy of a
building shall be made without a Certificate
of Occupancy -(UBC Sec. 502)'
CERTIFICATE OF OCCUPANCY
BUILDING DEPARTMENT
GARFIELD COUNTY, COLORADO
Issued Without Fee
_ __,,D_,,e,.c,,e,,,m,,,b"'e"'r'-'2,_,2~ ___ 19 __23
Permission is hereby granted to ____ Ge,,',.,,n,.e'--'&"--'B"'e"'-"'t,,tct.y__.S,_,e'-'t'"!"'1 _________________ _
..,Building Permit No. __ 41,......._ _______________ Zone District __ ..cJcJ.ll ________ _
j ~situated at -1""71--'JO-E,...a""s"'t---'T"'a"'n .. ia .. r;.is .. c;.>k-,,,_,B.,a•t~t~l.i.e .. w .. e .. u=t_..,M..,e"'s"'a'-----Lot -14...-BI k. J.5__ Addition _____ _
for the following purpose, __ r1.1u1U1s.tt;.osi..lLl.1.-.1<r.1,. • .,p,,,11.1i:faa..:c'1t.i:JJ11.r=e"'clHli"'·'ao~""'e~---------------------
(Stata Natura of Use)
Contractor _ __.Bwa~t.._..t.lse~m....,..n~t"'-'~~ie.,_.s~a.._.H~ome,,.,,~s,,_._,__,I±n~ccl,.__ ________________________ _
Issuance of a Certificate of Occupancy shall not be construed as an approval
of the. provisions of this code or of other ordinances of the jurisdiction.
Certificates presuming to give authority to violate or cancel the provisions
of this code or of other ordinances of the jurisdiction shall not be valid.
(UBC Sec. 307(a)).
White: Owner Green: Lending Agency Yellow: Building Department Pink: Ass£!sso,~_,· Gold: Contractor