Loading...
HomeMy WebLinkAbout5379GARJ<JELD COUN1Y BUILDING, SANJTATION and PLANNING DEPARTMENT I 09 llh Strcc:t Suite 303 Glenwood Springs, Colocado 81601 (303) 94>-8212 1'1o. 5379 JobAdd<CSS ____ o_6_6_l_D_o_l_o_r_e_s_._c_i_r_c_l_e_,_w_e_s_t_b_a_n_k_M_e_s_a_,_L_o_t_2_9_,_G_l_e_n_w_o_o_d_S_p_r_i_n_g_s __ _ NaturcofWork. __ B~1,.1,.i.,l.,.d..,,i"n'"g._P.._e"""r,.m.,i,...t ___________________________ _ Use ofBuildin.._ __ S_i_· n~g_e_l_F_a_m_i_· l_Y,,___Dw_e_l_l_i_· n_g"'-_wc./_D_o_u_b_l_e_G_a_r_a_,ge.e ______________ _ Owner Robert J. Snyd~_r _________________________ _ Conlractor ____ o_wn __ e_r ________________________________ _ Amount of Permit s.~_l-''-"3-'4-"3-' •. ~9-'2'-~----'-­ P errni t: 814.50 Plan : 529.42 Paid $1343. 92 Datc. __ D_e_c_e_rn_b_e_r __ 2~,_1_9_9_4 ________ _ S. Archuleta Clerk GARFIELD COIJNTY APPLICATION FOR BUILDING PERMIT PERMIT 1'UMBER .,53 7 '1 DATE____,_/~',;{~-~~~-~7~i'--~~ Assessor' a Pare.el II please print or type ....1 < "' "' ....1 ftl ~ Galena St:e A ~ 0"' !:! ~ ~ :i ~ 1ew N ALTERATION ADDITION _.o.;'------------lEMOLISH REPAIR MOVE ---fOBILE HOME (make/l!IDdel) >.F. OF BUILDING 4.84.3 S.F. OF WT 1.18 ac. I OF PWORS 2+ basement: HEIGHT 8. ·0" I OF FAMILY UNITS 1 # OP BE-DR_,OO.._N""'s"'--4--- 'NTENDED USE OF BUILDING single family res. :ARAGE: SINGLE DBL X CARPORT: SINGLE DBL 'IREPLACE zero-clearance gas log - DOCUMENTS ATTACHED ~ATER suPPLY West:bank Mesa well IRIVEWAY PERMIT :ITE PLAN 2 se""""t~s-------------- 11/ILDING PLANS 2 sets -=-"-"--'-"---'------------;ANITA RY SEWER CLEARJWCE ----------- IN SITE SEWAGE DISPOSAL PERMIT ~~------~ ITHER DOCUMENTS/ (specify) .Si:tt?f< ~ Cti,/1'7'JP&,nf&;r/ eNtJ-.1-'lfe-,/-e'S PLOT PLAN ShOw easements, property line dimensiOJ all other structures, specify north, and stre1 name. For odd shaped lots, or it· space is too small, provide separate plot plan • # OF BUILDINGS NOW ON PARCEL _.N.,..o...,n .. e..._ ___ _ USE OF BUILDINGS NOW ON PARCEL -~N~/~A----- FRONT PROPERTY LINE STREET· NAME/ROAD NUMBER Delores Circle CHECK IF CORNER LOT Yes DESCRIPTION OF WORK PLAN·--N-ED--=s,iri8~~1~e~f ...... ~---1~1-r- residence I hereby acknowledge that I have read this application and t:hf> above is correct and I agree to cpmplg with all county ordinances and · 1a., 1 uilding constructic FOR OFFICE USE ONLY FLOOD HAZARD -=:---:-==:-=:::-=:-----i..------- CERTIFIED BLDG ELEVATION -====-------SPECIAL CONDITIONS -----------~ PROBLEMS WITH PERMIT ----------==- llDDITIONAL INFORMA'I'JON NEEDED ------- CERTIFIED BY COLORADO REGISTERED LAND SURVEYOF OR ENGINEER . Assessor's Parcel No. _______ _ Date /.;{-d?-7Y /) BUILDING PERMIT CAfW ( /,) . Job Address j!tJ~/ ~~ W~//ZLJ,,_, qgd<t;,_~~ Owner~,i ~.11 '/?.,mlf Address~...>S.~~hone# 9'a~~ Contractor ~ Address Phone # f'?'S--/vS/6 Setbacks· Fr;?Jr~ Rear.d~~ LH_ Zoning s1Z; ~fi 0/_~ 1NsPEcr~2:: Footing _L~-'1'!jl ~ ~1 'Mechanical_ ----·-- FoundaiionJQ ~t~ <l=oy--' _ Electrical Rough (State) IL 23S -~7'1 ____ _ Grout_ Electrical Final (State) 1)-3 ·9c,-L'c-eu2 ___ _ Underground Plumbing Final/;<.-/~-?'.!> /Checklist Completed?,,,_{ __ _ Rough Plu,mbing 1?-1£-•) ,---!~~ Certificate Occupancy# __ __ Framing_2 .. 1§ -'·26' fitl~ Date. ________ _ Insulation _2'. rl I K ~ 7' 5' ~ Sep lie System # ef..3-'l.J---:r----·--- Roofi ng . . . Date ......LA-;/-'7z._ Drywa.11.J/~Z--71··--:.o -<,,'-7 .....,_ • .,~ Final -=--'-~--------- Gas P1p1ng j-23 .. 1/s-kedi Other ___________ _ NOTES 6"1= ...4'.e. 5,.,,)''7~ /?'-<-\~ /f ft7 ~~~/12. /-r:?'t""'t//-VzS ~ ~-r: . (continue on back) @ R~o/ lf?-e/fr~ .5?l!>/"r>.w6 /!?2~/VO c••w~ r-c..v£ V-- /? -(j~_,e,..,,_,-~~~"'""""" oJ._ ~-tJ-= ~"'"" /.r,'/ ,?.~--&P,Qy ~ (§) fl/?4"'6Wt;? /A--_,,,,__ ,4,.,e 6'~ A0E2. ;;d?'~ef! ~ tP lse~ u_.,,~ ~ /kn:..,~e.v .:::;~, ~-v'" ';1.-/s ·11: -snu /.UC>l2Jt!r.a "'~ ~ CJfc ----·----·----------- 06/19/95 08:30 011/19186 . 08: lli, ~ ... l'J Ill > ii .. .... -I iii .., c c li: ~ "' 0 " ' .... .... !'; 'if i: I '" q ~ ~ Cl b "' " • 00 "' ill ... "' 0 :;) " .. .... ~ '5'303 945 2445 '8'303 984 3533 BMC WEST GWS Tl!.USFAB INC. ............. \j ~ ~ ~ \ .... I;-.. \" !! • l!U.t1lil! i'. ,.E .-..... !I>-... "' ~ .. .... .. iii~ ~ ill .... ~ 1\~~ "' .... ~~~" m N•• .. a . ~ .. ...... "' M :lllVlllJ " ' "'"' .. ~, " ~ " N"' "" j:J~"' ~ "' .. _.,, "' :I II lol "' •• F;! .. ~ il1 ~~~ .. i m ' ~ I l l ., f ~ ., f ""ti G' t; ~ ~~ ~ 2J... "\ ~ ~ ~ • ~ 70 Q ~ ............ 0 .. ~~ •• " 0 '° • oli '""ii' 'l''ti li!I001 ~002 ,J ~WU (' ~ .. ,. ~ND ..0 ..... "'~ {_,J " ' ~~1 ~ ...... ...... .. "' ' ,,. "' .. ~/ C> i§t j = 1 1 1 LU111!ER SPECIFICATIONS Tap COOrd ~· 6 Jf 2100F-1.BE MSR Sot Chora ~x 4 • 1650F-1.5£ '1SR Web P1e~a 2Jj 4 ii :165DF-l. 5E MSR Left Wedge 2;11-4 12 ar Bvtter~ ! R1ght W&dge 2»4 12 or Better!! llEAR!NG REQUIREMEHTS 0£ARING •n' SIZE Rea. SIZE EJ1 .. 5;50 In. !. 75 JJl_ BL 5.50 Jo. 3.51 In. SPF/ESLF' SPF/ESL.P SPF/ESLP L6S 1005 1765 9RAC.lNEi '1Ef'l9ERS SHOWN 8V :11 W~E: ~OUtRED. !XI CONTINUOUS LATERAL 8RACIN6 ATTACHED I/ITH TWO (2) 9d NAILS, ICBO: THIS TRUSS HAS BEEN DESIGNED IN ACCOROAJCE "ITH Icao RESEARCH REP.ORT !607' ~-eaoo HOLDING \',4.LU€S AAE 203 PSJ IN SOUTHERlll PINE'/OOUGL.4S FIA~LARCH ANO 15:? PSI IN HE/'1-FIA/Sl'RUCE·PINE-FIR .. ~ THIS TRUSS IS llESIGNEO USIMJ THE UBC-91 -CODE. BASIC WIND Sl>EED •BO MPH ~ Thi~ Design has Deen c~ecked far 10 Q.s.t . L'?kLIJ!'!_£1iUI d ltoc lu&d itl dt:i!J; dd: LI! -""1 Wlt;h \JO\... .10-tl-0 ~ ... .... ... ... 0-B-OJ: '""" ... ... 1-a---a Li "' ... c ... IJ "' • "" C> ... "' ..... "' ... ..... ... C> R5000 UBC-91 2•.00• o.~. 4/2B/B2 A TrusPlus Design 7048A/ TAIJSfA6/ Vlll'a!oo 4.25 7o4-S 06 Top Chd BDtto~ l7'1d T 1,,. -.1655 B J• 1158 W-1 ""' T 2 .. -1158 B 2"" i160 M 3 "" T 3-" -15,2 H 3,,. 1156 lleUo ® G:,-c!'ACM I-~.~ f--- 12 ia[7 30-0-0 / .. ,!j; 2445 191 w 2 .. -3 197 /\ / '\. / " 10-0-0 SP.1246 SPECl~L PLAff POSlTJONING CHART JOINT# x:. (inf Y: (inJ ANGLE l 2 3 • 3.34 o.oo -1. 75 -3.34 3.22 -6.21 Z.28 a.22 22.5 2a.s -2.2 '5 -22.5 stendi!l"'d 1"1.'.I form t.oaCSing fPSFJ TCLL -•o.o: TC!ll • lO O; BCOL -IO o: 1ti;:a~~~o 5E~~~lI0Pf 8ASED ON"L/360 ·~+--~~~~~'"'"'o-a-o '\. 6475 ' Ai62!0 12 '\]12 p-s-o 4852 9-6-12 I 10->-a I I 10-1-12 I 30-D·O OVel!ALL SPA• Qty : 6 I TNss name "' x--- 10"d "ltl!Ol D < 10. d 9660PVS 01 1Nl&Gn18: OODf'lN31EI l..,fii:f 61 :12ft S66t-SG-Cld:I GARFIELD COUNTY BUILDING INSPECTION DEPARTMEN'r 109 8th Street Glenwood Springs, Co. 81601 (303) 945-8212 Plan Review Correction List Snyder Residence 0061 Dolores Circle Westbank Mesa, Glenwood Springs, Co. Permit # November 30, 1994 The following comments based on the 1988 edition of the Uniform Building Code shall be resolved prior to the issuance of the building permit. The purpose of this review is to provide for minimum protection of life, limb, health, property, environment and for the safety and welfare of the consumer and general public as regulated by the u'Bc. 1:tf' The required design snow load for Garfield County is 40 psf and the UBC required design load for floors is 30 psf. The.plans specify design loads of 30 psf for the roof and 30 psf for the second floor . The plans also specify the structural specifications should be reviewed by a structural engineer. The plans are also unclear regarding the transfer of the second floor loads to the foundation. The triple 2 x 10 beam in the basement and the standard 2 - 2 x 12 headers over the garage appear to be undersized, the second floor roof appears to bear at mid span of the second floor floor joists, the roof rafter spans should be verified for a 40 psf design load, and there are several point loads that the building department is unable to analyze. Please provide revised plans and engineering by a structural engineer to verify the proposed structurals compliance with the required design loads and clearly indicate how loads will be transferred to the foundation. Sec. 302, 2520, 2517, Table 23-A. 2. Specify the location for the furnace/boiler and hot water heater for approval. Sec. 302. 3. Plans specify a foam form foundation system. The applicant should be aware that foam cannot be left exposed in the basement. Please specify an approved thermal barrier to cover the foam. Foam must also be covered in the crawl space unless an approved listing can be provided to the Building Department allowing the foam to be left uncovered in the crawl space. Sec. 1712. 4. Refer to the conditions of permit and redlined plans for other code requirements. * Plr" 1111. S-1JVillf""1.. Plfrr1• "or 111.rr~ t:1A'rll'r ' .rnr ..... ,~ c. p1t tJ ,,,,;,, l'1 c:o""''",-11: nr.1r1I"""' . OF' sr11"e'""'""' ,.,,,,,.,r; f?l['t,J11111,,, f'ltiolf. • • • ro aK~ll'PI'"~ Fn"lrllN'. / Garfield County Building Inspection Department CONDITIONS OF PERMIT Job Address: 0661 Dolores Circle Lot 29, Weslbank Mesa Owner: Robert]. Snyder Contractor: Owner Phone: 925-2450 Date: November 28, 1994 Occupancy: R-3/M-l Type: V-N Floor Area: 4,858 sq. ft. # of Stories: 2 Valuation: $150,002. The following comments based on the 1988 edition of the Uniform Building Code™ shall be resolved. The approval of plans and specifications does not permit the violation of any section of the Uniform Building Code or any federal, state or local regulations. Any and all deviations from the original plans and speculations approved by the Building Department shall be submitted to the Building Department for approval. GENERAL COMMENTS GEN-1 It was assumed that the uses and materials in the building will be compatible with an R-3/M-1 Occupancy. GEN-3 Approved numbers or addresses should be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Section 513. This requirement should be noted on the plans. GEN-9 Obtain separate plumbing, electrical and mechanical permits as required. GEN-19 All electrical work shall be approved by the state electrical inspector and verification of such approval shall be provided to the building inspection department prior to issuance of a Certificate of Occupancy. EIRE-PROTECTION REQUIREMENTS E:l.1 Fire stops should be provided in accordance with Section 2516 CO. E,12 Draft stops should be provided in accordance with Section 2516(0. E:25 Enclosed usable space under interior staitways should be protected on the enclosed side as required for one-hour fire-resistive conslruclion. Section 3306 (m). ~-: c .~ EXIT REQUIREMENTS X:28 Risers on stairways should not be less than 4 inches nor exceed 8 inches, and runs should not be less than 9 inches. Section 3306 (c). x=3.l The top of handrails should be placed not less than 34 inches nor more than 38 inches above the nosing of treads. Section 3306 (j). X::34 Handrails should have their ends returned or should terminate in newel posts or safety terminals. Section 3306 (j). X36 Guardrails for stairs, balconies and landings should conform with Section 1711. Note that maximum clearance between intermediate rails should be 6 inches and guardrail height should be at least 36 inches. Section 1711. X:31 A minimum headroom clearance for staitways of not less than 6 feet 8 inches should be specified on the plans. Section 3306 (p). :&d6 Exits should be illuminated to comply with Section 3313 (a). Xc6B Provide landings at doors per Sec. 3304. GROUP R OCCUPANCIBS RA Basements in dwelling units and every sleeping room below the fourth story should have at least one operable window or exterior door conforming to Section 1204 for emergency escape or rescue which should open directly into a public street, public alley, yard or exit court. Section 1204. Maximum sill height: 44 inches Minimum net clear opening width: 20 inches Minimum net clear opening height: 24 inches Minimum net clear opening: 5. 7 square feet R=6 Mechanical ventilating systems in bathrooms, laund1y rooms and similar rooms should provide five air changes per hour directly to the outside. Section 1205 (c). RJ3 Dwelling units and hotel or lodging house guest rooms that are used for sleeping purposes should be provided with smoke detectors as specified in Section 1210. Iklfi Every dwelling unit and guest room shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees Fahrenheit at a point 3 feet above the floor in all habitable rooms. Sec. 1212. &TI Window wells for required egress windows in basement shall be a minimum of 36" in depth. 2 ROOF CONSTRUCTION AND COVERING REQUIREMENTS ROOF-3 An attic access opening (minimum 22 inches by 30 inches) should be provided with a minimum clear headroom of 30 inches. Section 3205 (a). RQOF-4 Provide attic ventilation per Section 3205. RQQF-10 Shingle application should comply with Table No. 32-13-1. ROOF-13 Enclosed rafter spaces shall have cross ventilation for each rafter space. The net free ventilating area shall be not less than 1/150. Section 3205 (C) Ul3C . ROOF-14 Asphalt shingle roofs 4:12 and over shall have applied one layer No. 40 coated roofing, coated glass base, or bituthane from the eave to a line 12 inches inside the exterior wall line with laps cemented together. Table 32-13-1 Ul3C. MATERIALS AND CONSTRUCTION REQUIREMENTS MAT-1 Building paper or felt should be applied to exterior walls as specified in Section 1707 (a). MAT-2 Foam plastic insulation should comply with Section 1712. MAT-11 Skylights should comply with Chapter 34. Plastic skylights are allowed under the conditions specified in Section 5207. MAT-24 Water-resistant gypsum backing board should not be\1sed in the following lo.cations (Section 4712): 1. Over a vapor retarder. 2. In areas subject to continuous high humidity. 3. On ceilings. MAT-29 Safety glazing should be provided at hazardous locations. Section 5406 (cl). MAT-35 Anchored veneer should be installed per Section 3006. MAT-36 Fireplaces shall be installed per Chapter 37, UMC and manufacturers' specifications. Provide details for approval prior to installation. Sec. 302. STRUCTURAL COMMENTS: STR-42 Lateral bracing should be provided in accordance with Section 2517 (g) 3. STR-64 Cold Weather Requirements. Adequate equipment shall be provided for heating concrete and masonry materials and protecting concrete during freezing or near-freezing weather. All concrete materials and all reinforcement, forms fillers and ground with which concrete or masonry materials or materials containing ice shall not be used. 3 STR-65 The manufacturer of concrete shall furnish to the purchaser a delivery ticket with each batch of concrete before unloading at site providing the information specified in Section 26.1311 UBC Standards . These tickets shall be saved and available for review by the I3uilding Official. -~ STR-67 Lumber beams, rafters, trusses and joists shall be supported laterally over beams and points of bearing with solid blocking. Bridging or solid blocking shall be installed at intervals not exceeding 8 feet when the ratio of depth to thickness exceeds 5 to 1 (e.g. 2 X 10). Sections 2506(h), 2517(d) 3 2517(h) 6. UI3C,. STR-68 Joists cantilevered beyond the supporting structure shall be blocked solid at the point of bearing. Section 2517(cl) 3, UI3C, . STR-70 Verification of the soils condition made by a licensed soils engineer will be required by the Building Inspection Department as specified in the general notes on the submitted plans. Documentation shall be provided prior to pouring concrete. STR-72 Foundation plates or sills shall be bolted to the foundation or foundation wall with not less than 1/2" nominal steel bolts embedded at least 7" into concrete or reinforced masonry or 15 inches unreinforced grouted masonry 6 feet on center, two bolts per piece minimum and one bolt within 12 inches of the encl of each piece. Section 2907 (e.), UBC, . STR-81 Ends of wood girders entering masonry or concrete walls shall be provided with a 1/2 inch air space on tops, sides, and ends unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 5. STR-91 Basement walls below finished grade are required to be damp-proofed. Sec. 1707(cl). STR-92 Provisions shall be made for the control and drainage of surface water around buildings. Sec. 2905(0. ST.&22 Buildings and structures shall be designed and built for at least a 40 psf snow load. Section 2305 D. SIRJ.D.3 Residential floors shall be designed for 40 psf live load. Table 23-A. PLUMBING COMMENTS Eld Plumbing and fuel gas piping must comply with the UPC and should be installed by a plumber licensed in the State of Colorado. MECHANICAL COMMENTS MECH-9 Liquefied petroleum gas-burning appliances should not be installed in a basement [Section 504 (t)]. MECH-11 Fuel-fired appliances located in a garage should be installed 18 inches above floor level as required by Section 508. 4 MECH-76 Location and installation of boiler, hot water heater and furnace shall be in conformance with Section 703 and Chapters 6 and 7 of the Uniform Mechanical Code, and Chapters 12 and 13 of the Plumbing Code, providing for adequate access, clearances, ventilation, and combustion air. The mechanical enclosure shall be a minimum of 12" wider than the furnace with a minimum of 3" clear work space along the sides, back and top and 6 11 along the front or firebox side. The purpose of this review is to provide for minimum protection of life, limb, health, property, environment and for the safety and welfare of the consumer, general public as regulated by the UBC. 5 .,.,,.,.,,."''' November 11, 1994 Art Hougland Robert J. Snyder Realty Services, In--. 305 S. Galena Suite A Aspen, Co. 81611 303-925-2450 303-544-0996 (fax) Garfield Building and Planning Dept. Hand Delivered Dear Art; I finally got a foundation plan from Patillio and Associates. They have not completed the structural framing plan but they indicated that they would have that drawing completed either Tuesday or Wednesday. I will give you two copies of that drawing when they get it completed. We would like to be able to obtain a foundation permit as soon as you can fit that into your schedule so we can get started on the foundation and get that completed before the good weather goes away. I will then see how the winter is shaping up before moving forward with framing so a final complete permit is not as urgent as getting the foundation in place. I just received the November 8 notice concerning the ISDS be designed by a PE. I like everyone else up there had been operating under the assumption that a septic system installed in compliance with the soils test was going to be sufficient. Since that is not the case myself and some of my neighbors are negotiating with an engineer to design all of our systems at one time in hopes of getting a volume discount for that work. Once I get his design I will forward that one as well. I have submitted a check request for $1,343.00 to Pitkin County Bank w.- administering my construction loan and my funds that I have committed • the project. They want to be in the position of writing all of the checks so I anticipate them getting that check to me early next week. Please give me a call if you have any questions. , GER DRIVE 40 29 166.87' _; 198 52' 18.82' $8 • : S07"27'58-"W _ ___, 2 32 02"£ 0 40 - - R = 7.00' L = 11.00' 80 120 ---GRAPHIC SCALE IN FEET 1 INCH = 40 FUT • , GER DRIVE 40 e I~ 1 18 Ac . • 166.87' _j 198 5"'' 18.82' __ ......., · ..:: so7·27· 0 40 R == L - 80 ---120 ----GRAPHIC SCALE IN FEET I INCK .. 40 FEET 1.rf CV GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION ADDITIONS ALTERA TIO NS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. 1bis book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: I 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes _.;{__ No _____ m Not necessary for this project _____ 12> 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes _X_ No ____ 11> Not necessary for this project _____ 12> 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes -X--No _____ u> Not necessary for this project _____ 12> 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform buildiA,g code or per stamped engineered design? Yes -.K.--No _____ 10 Not necessary for this project _____ 12> 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes -X--No _____ 11> Not necessary for this project _____ 12> 6. Do the plans indicate th~ size an location of ventilation openings for the attic, roof joist spaces and soffits? Yes _)(__ No _____ 11> Not necessary for this project _____ 12> 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per squar$-foot in Garfield County) floor loads and wind loads? Yes ..LL__ No----<•> Not necessary for this project _____ 12> 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes ,.X__ No _____ 11> Not necessary for this project ____ 12> 9. Does the building section drawing include size and spacing of floor joists! )'Vall studs, ceiling joists, roof rafters or joists or trusses? Yes _,l(__ No _____ u> Not necessary for this project _____ 12> 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? 2 -,P- 11. 12. 13. 14. 15. 16. 17. 18. 19. Yes_){__ No _____ 111 Not necessary for this project _____ (21 Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span pj!tween the ridge and the eave down to existing grade contours? Yes ..2(.__ No _____ 111 Not necessary for this project _____ (21 Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifi,cp.tions or phase II EPA certification? Yes -A--No _____ (!) Not necessary for this project _____ 121 Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code L Chapter 37? /Vt? c--/ £ Yes ____ No _____ (!) Not necessary for this prpject _,£(21 4-//i?a--'"'-!:?J/ /V()t //,tN''-'ir ~ P1#-:0~ft'cJ-<)2/JZe~L&c/ A/4f?K ~u'/e'N/.ffc)-: t'"~Cle'A"/f?-Vz!fs Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements complY. with the requirements of the Uniform Building Code? Yes _g__ No ____ (11 Not necessary for this project _____ 121 Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes _x__ No _____ 01 Not necessary for this project _____ (21 Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes 1._ No _____ (11 Not necessary for this project -----<21 Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes -x___ No _____ 111 Not necessary for this project -----<21 Have two (2) complete sets of constructions drawings been submitted with ~qe application? Yes _,X__ No _____ (!) Not necessary for this project ____ <21 Have you designed or had this plan designed while considering buildi,9g and other construction code requirements? Yes .,A__ No ____ (3> 3 20. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Department? Yes _){___ No ____ 13> 21. Do you understand that approval for design and/or construction chang,e; are required prior to the application of these changes? Yes _A__ No _____ 13> 22. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permi9 Yes -.A---No _____ 13> 23. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and OCCUPflJlCY of the building? Yes ..,4__ No _____ 13> 24. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the proje<\~complying with ~e Uniform Codes". Yes ..,4_ No-----"> I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. date Phone: W-;2LfS-0 (days); _,_2--"'>.J.--CC-3_-~,J-'-'-9_5c"-:;.L. __ (.evenings) Project Name: Project Address: 4 •···· . . .• Notes: (1) If you have answered "No~ on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays In issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and It is determined by the Building Official that the information ls necessary to review the application and plalls to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits In the review process and not reviewed until required information has been provided and the application rotates agatn to first position for review. B. Delay in issuance of the permit. C. De.lay in proceeding with construction. (3) If you answered "No" to this question the clrcumstances described in the question could result In a "Stop Work Order" being issued or a "Cer!iflcate of Occupancy" not being issued. PerAppOl.94 Effective May l, 1994 5 THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT ~A FIELD COUNTY, COLORADO __ Date Issued'-~/.~ ___ ,_t./zoned Area ________________ . _______________________ Permit No. -~-5___1___9_ _______ ___ AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit m y then be revoked by notice fro o}l'll'Y B ing f!» eJtor a IMM:Ep -ELY B ~tE ~LAND VOIJ>, Use f-~-f W ~ U. . C" CJtl/l't!'! ~ Or~S 5. Setbacks Front Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspeetion. INSPECTION RECORD Zoning Roof Covering Electric-Final (by ST ATE inspector) Footing /;:?,~S'~CJ !jct\ -'"1 '.;o. -g -;t :;-A>--e L J;f . ~23S 379 Foundation/ .2-/ 2 9;:.; <F\ -1~ ~ Plumbing-Underground Gas Piping 'l-7z-"7S: J~ Heating Ventilation Frame l-o -'7-'> ~ Insulation -_ • ~ ~ ~ )?. />('. •<l r I°' Plumbing-Rough '7 --; 3--q_,-) ) -s-.ao..c;_~-v p--sr/P-s ~ ~..,,__.. Drywall '!-?-<?-"' ;-c:. -"·~ Electric-Rough (by ST ATE inspector) Final l,;l--/3 -:tS" J,,,..,,,-- ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 JO 9 8th Street, County Courthouse, Glenwood Springs, Colo. APP ·1 ., Certificate Of Occupancy No. 2692 Building Department Garfield County, Colorado No change in the character of occupancy of a building shall be made without a Certificate of Occupancy -(UBC Sec. 502) This certificate is issued pursuant to the requirements of Section 307 of the Uniform Building Code certifying that at the time of issuance, this structure was in compliance with the various codes adopted by the County regulating building construction or use for the following: Use Classification Single Family Dwelling w/Double Garage --~---~---~------~----Building Permit No. __ 5_3_7_9 ____ _ Group R-3, M-1 Type of Construction __ v_-_N _______ _ Zone District ____ _ Owner of Building Robert J. Snyder Address 305 S. Galena Ste A, Aspen, CO Bui] ding Address __ 0_6_6_l_D_o_l_o_r_e_s_c_i_· r_c_l_e_,_G_l_e_n_w_o_o_d_Sp_r_i_n_g_s_, c_o __ _ Locality Westbank Mesa, Lot 29 Contractor __ Own_e_r _______________ _ Address __ s_a_m_e ______________ _ ' ·~ By~~~±=>c, 71~@11l1-~(~l''.~~~~~~~~ = Chief Bu~g Official December 18, 1995 Date -------------------- Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. (lTBC Sec. 307(a)).