HomeMy WebLinkAboutOWTS System Design 09.14.201733 Four Wheel Drive Rd Carbondale, CO 81623 970.309.5259 ECEV�. SEP 1 9 2017 September 14, 2017 Project No. C1318 Tony Fotopulos afotopulos@hotnnail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 2 -Bedroom Residence 6598 Hwy 82 Garfield County, Colorado Tony, ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Glenwood Springs, in an area where OWTSs and wells are necessary. Legal Description: Section: 1 Township: 7 Range: 89 TR IN LOT 9 Parcel ID: 2395-011-00-020 SITE CONDITIONS The single-family residence was previously developed on the property burned down. A 2 -bedroom, single-family residence is proposed. The existing OWTS that served the previous residence must be removed or properly abandoned. There is a private well located on the property greater than 50 -feet from the proposed septic tank and greater than 100 -feet from the proposed soil treatment area (STA). The water line entering the house may not come within 25 -feet of any OWTS component. The proposed STA will be located in a relatively flat area south of the house that is vegetated with native grasses and sage. The STA must be located at least 20 -feet from the residence and 10 -feet from the property line. There are no potential future land use changes or bedroom additions planned for the property. Page 2 SUBSURFACE The subsurface was investigated on September 8, 2017 by evaluating soils excavated from the foundation of the house on the immediately adjacent property. A visual and tactile soil analysis was completed by Carla Ostberg at the time of site visit.' Prior to construction of the STA, a soil profile test pit (Test Pit) must be excavated to at least 8 -feet below grade to assure no confining layer is encountered and soils are consistent with those analyzed. The soil formed a ball, but did not form a ribbon. Soil structure shape was single -grain and consistence was loose. This sample is typical for soils in this area. STA sizing is based on Soil Type 1, Loamy Sand. A long term acceptance rate (LTAR) of 0.8 gallons per square foot will be used to design the OWTS, in accordance with Table 10-1 Soil Type 1 presented in the Garfield County On -Site Wastewater Treatment System Regulations, adopted April 14, 2014. DESIGN SPECIFICATIONS The existing septic tank must be removed or properly abandoned in place. Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD LTAR = 0.8 GPD/SF 300 GPD / 0.8 GPD/SF x 1.2 (gravity bed) x 0.7 (chambers) = 315 SF The new OWTS design is based on 2 -bedrooms. An average daily wastewater flow of 300 GPD will be used. A double -sweep clean out must be installed on the 4 -inch diameter SDR -35 sewer line exiting the residence. This sewer line must maintain a minimum 2% grade to the septic tank. A new 1000 -gallon, two-compartment concrete septic tank must be installed. An effluent filter must be installed on the outlet tee of the septic tank. The septic tank manhole lids must be brought to grade with risers. The septic tank may not have more than 4 -feet of cover over the lid of the septic tank. The STA will consist of four rows of 7 `Quick 4' Infiltrator® chambers, connected with a level manifold, for a total area of 336 square feet of infiltrative area. The infiltrative area may not exceed 4 -feet below native 1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 3 grade. Inspection ports must be installed in each corner of the bed. We recommend installing a swale around the STA as a path for drainage. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Garfield County On -Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STAs. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. Page 4 INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS o. 5 Rebar .& uminum Cap S. No. 14060 10' MIN. TO ;OPERTY LINE PROPERTY LINE & Cap r. 15710 fY It Power Pole Retaining Wall M CE 20' MIN. HOUSE°� TO STA 5 MIN. HOUSE TO TANK _ l "ravel Drive No. 5 Rebar & c a L.S. No. 15710 MIN. 100' M°s 50 0 WELL TO TANK Overhead Electric No. 5 Rebar & Aluminum Cap L.S. No. 11204 - DESIGN No. 5 Rebar Illegible Cap No. 5 Rebar & Aluminum Cap L.S. No. 11204 2 -BEDROOM RESIDENCE (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 2 BEDROOMS) WASTEWATER FLOW = 300 GALLONS TANK: USE 1000 -GALLON, TWO-COMPARTMENT CONCRETE SEPTIC TANK SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.8 GAL/ SQ FT CALCULATED STA = Q/LTAR = 300 / 0.8 = 375 SF GRAVITY, BED = 375 SFX 1.2 = 450 SF CHAMBERS = 450 SF X 0.7 = 315 SF / 12 SF / CHAMBER = 27 CHAMBERS •Power Pole INSTALL SWALE ON WEST SIDE OF STA 4" DIA SDR -35 - LEVEL MANIFOLD 4" DIA SDR -35 INSPECTION PORT AT EACH CORNER OF BED 20' MIN. HOUSE °- T9 STA Retaining Wall 10' MIN. TO J PROPERTY LINE PROPERTY LINE 5 Rebar & 4.0 L.S. No. 15710 Edge of—/ Asphalt w� 4 ROWS CjF 7 'QUICK -4' INFILTRATOR CHAMBERS = 28 CHAMBERS = 336 SFS No. 5 Rebar & Cap ' L.S. No. 15710 J 5' MIN. HOUSE T9 TANK N,- 1 I i Gravel Drive 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT SCREEN 4" DIA SDR -35 SEWER LINE WITH DOUBLE -SWEEP CLEANOUT (MIN. 2% FALL TO TANK) overhead Electric No. 5 Rebar & Aluminum Cap L.S. No. 11204 MIN. 35 ENT PIPE % FALL SEPTIC SDR -35 EVEL OLD T TA TO EACH ROW INFILTRATOR END PLATE GRAVELLESS 'QUICK -4' LOW PROFILE CHAMBER (4' x 3') 12' 28 CHAMBERS 28' -PIPES PLACED IN TOP PORT OF CHAMBER END PLATES PLAN VIEW NOT TO SCALE SLOPE FOR DRAINAGE L4" DIA SDR -35 INSPECTION PORT AT EACH CORNER BED COMPACT SOIL BASE TO SUPPORT BOX USE HOLE SAW TO CUT THRU TOP OF END PLATE INFILTRATOR(R) QUICK4(TM) LOW PROFILE CHAMBER, 3'X4' SDE BACKFILL MUST BE MINUS 3 -INCH MATERIAL SCARIFY SURFACE O SECTION VIEW NOT TO SCALE MIN. 1 -FOOT COVER OVER CHAMBERS i 0 CHAMBER DETAILS NOT TO SCALE SLIP-ON PVC CAP DO NOT GLUE INSULATED COPPER TRACER WIRE 4" DIA SDR -35 SEWER LINE BOX OR VALVE I ATTACH CLEANC 4" PVC F FIT TO TANK ® CLEAN OU Item # 1000T-2CP 1000 Gallon Top Seam Two Compartment Top View Section View 60" Flexible Boot 6 3" 5 20" Clear Access ,.l / (Big Hole Lid & Riser) C,' I *Meets ASTM C-1227 spec including C-1644-06 for resilient connectors • 6000 psi concrete • Delivered complete with internal piping • PVC, poly or concrete risers available O Option of pump or siphon installed 106" Digging Specs Invert utyl Rubber Sealant Dimensions 11' Long x T Wide 56" below inlet invert Inlet 56' Outlet 53" Length Width Height 111" 6O I 68" Net Capacity Inlet Side Outlet Side Total 687 gallons 323 gallons 1,010 gallons Net Weight Lid Tank Total 2,620 lbs 9,380 lbs 12,000 lbs Water &(719) 395-0764 2Q6 Co. Rd. 317 Wastewater P.o. Bctx NFIALLEY • PSrndus Fax: (719) 395127 Buena Via, CD a1211 ct RECAST, Inc. • Service Website: www.valleyprecastoom Email: frontdesk@valleyprecastoom Item # BH Lid, BH Lid Lids Small Hole Lid (18" Clear Access) Common on standard two compartment tanks 75 lbs Big Hole Lid (20" Clear Access) Common for pump, one compartment, dosing, cistern and all 500 gallon tanks 105 lbs kill Dump Access Casting in Schedule 40 Pipe *Rebar and Flip Down Handles Available on Big Hole and Small Hole Lids 4- 20" 41M- 17" 23 11 1 20" 4" 4" i Schedule 40 Pipe 4" Water & Wastewater IleVALLEY • Systems . Products I1 PRECAST, Inc. • Service (719) 3954764 28035 Co. Rd. 317 P.Q. Box 925 Fax: (719) 3953727 Buena VW CO 81211 Webslte: www.valleyprecastoom Email: frontdesk@vaileyprecastoxn Residential Biotube® Effluent Falters Applications Our patented* 4 -in. (100 -mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4 -in. (100 -mm) Biotube Effluent Filter 4 -in. (100 -mm) Biotube Jr. (4 -in. Biotube cartridge avail- able separately as Insert Filter) 8 -in. (200 -mm) Base Inlet Filter 4 -in. (100 -mm) Insert Filter -• I Orenco's superior effluent filters resist dogging better than all other brands. Our stan- dard, full-sized 4 -in. (100 -mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4 -in. (100 -mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the All -sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. Covered by parent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS -FT -1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. CO Orenco Systems Incur{orated Changing the Way the tl%+-Id Does W zstewater"a www.orenco.com Nomenc9atures 4 -in. Biotube Filter (standard) FT[] 0 04 EL -11E1 I Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series 8 -in. Biotube Filter (base inlet model) FT[0822-14B 11 Options: A = float bracket FS = 2" outlet orifice ESO = 2" outlet orifice and overflow plate* Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filte diameter (inches) 08 = 8" Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series `Also available with coupling and sleeve as a "kit": FT-OVERFLOWKIT 4 -in. Biotube Jr. (includes cartridge and housing) FT J 04 18 Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Filte diameter (inches) fi s Type 3034 outlet tee fits Schedule 40 outlet tee W= s= Blank = 1/8" filtration P = 1/16" filtration Junior series Biotube effluent filter series 4 -in. Biotube Filter Insert (cartridge only) FT i 04 18 - For customized options (e.g., NC indicates North Carolina regions) W . fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filte diameter (inches) Blank = 1/8" filtration P = 1/16" filtration Insert Biotube effluent filter series 4 -in. Biotube Effluent Filter 4 -in. Biotube Jr. Extendible PVC handle • Stainless steel set screws". Top seal plate rr Air vuets Biotube R filter cartridge — Solid base Filter housing m — Riser wall Distributed By: INFILTRATOR' water technologies Quick4: The Quick4® Plus Standard Chamber Quick4 PlusT'Series The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36 -inch -wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel ConnectionTM which permits turns up to 15 -degrees, right or left. It is also available in four -foot lengths to provide optimal installation flexibility. The Quick4 Plus All -in -One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength Quick4 Plus Standard Chamber Specifications Size 34"W x 53"L x 12"H (864 mm x 1346 mm x 305 mm) Effective Length 48" (1219 mm) Louver Height 8" (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.6" (15 mm), 5.3" (135 mm), 8.0" (203 mm), 12.7" (323 mm) APPROVED in Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four -foot chamber lengths are easy to handle and install • Supports wheel Toads of 16,000 lbs/axle with 12" of cover Quick4 Plus All -in -One 12 Endcap Benefits: • May be used at the end of chamber row for an inlet/outlet or can be installed mid -trench • Mid -trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center -feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All -in -One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 12" raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical Officials (IAPMO) (Aar) Quick4 Pius- Series Quick4 Plus Standard Chamber vickif t" 34- Quick4 Plus All -in -One 12 Endcap F.i %' 4A fl AT 5Ar i ifli rim..m. et ALI raw 48 EFFECTIVE LENGTH PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 13' 33 FRONT VIEW Quick4 Plus All -in -One Periscope QUICK4 PLUS ALL -IN -ONE PERISCOPE (360° SWIVEL) 1.1 T1 1.f �t 12.7" INVERT INFILTRATOR` water technologies 5" 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 860-577-7000 • Fax 860-577-7001 1-800-221-4436 www. i nfiltratorwater.co m SIDE VIEW INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by Infiltrator ("Units"), when installed and operated in a leachfield of an onsite septic system in accordance with Infiltrator's instructions, is warranted to the original purchaser rHolder") against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this Limited Warranty. Infiltrator's liability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and Infiltrator's installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units, U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico. Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra -Rib is a trademark of IPEX Inc. © 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A. PLUS05 0713 Contact Infiltrator Water Technologies' Technical Services Department for assistance at 1-800-221-4436